Search NASA⌕ Search

SEARCH · Search NASA

Results for “Directed Molecular Evolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

202 records · Page 12

Probing the Kitaev honeycomb model on a neutral-atom quantum computer

Quantum simulations of many-body systems are among the most promising applications of quantum computers. In particular, models based on strongly correlated fermions are central to our understanding of quantum chemistry and materials problems, and can lead to exotic, topological phases of matter. However, owing to the non-local nature of fermions, such models are challenging to simulate with qubit devices. Here we realize a digital quantum simulation architecture for two-dimensional fermionic systems based on reconfigurable atom arrays. We utilize a fermion-to-qubit mapping based on Kitaev’s model on a honeycomb lattice, in which fermionic statistics are encoded using long-range entangled states. We prepare these states efficiently using measurement and feedforward, realize subsequent fermionic evolution through Floquet engineering with tunable entangling gates interspersed with atom rearrangement, and improve results with built-in error detection. Leveraging this fermion description of the Kitaev spin model, we efficiently prepare topological states across its complex phase diagram and verify the non-Abelian spin-liquid phase by evaluating an odd Chern number. We further explore this two-dimensional fermion system by realizing tunable dynamics and directly probing fermion exchange statistics. Finally, we simulate strong interactions and study the dynamics of the Fermi–Hubbard model on a square lattice. These results pave the way for digital quantum simulations of complex fermionic systems for materials science, chemistry and high-energy physics.

atomic and molecular physics↗

Photoenzymatic Csp 3 –Csp 3 bond formation via enzyme-templated radical–radical coupling

Cross-couplings are essential reactions in modern chemical synthesis, enabling the rapid construction of complex molecules from simple precursors. Transition metal catalysts are prized for these transformations because their reactivity and selectivity can be tuned via judicious selection of the metal and ligand. Although enzymes offer analogous opportunities for tuning via protein engineering, their application to cross-coupling remains limited, as nature relies on alternative paradigms for building molecular complexity. Here, we report the cross-coupling of alkyl halides and benzylic carboxylic acids using an engineered flavin-dependent lactate monooxygenase—a photoenzyme. The enzyme achieves this feat by exploiting the redox versatility of the flavin cofactor. Stoichiometric experiments, ultrafast spectroscopy, and computational studies support a mechanism in which photoexcited flavin quinone initiates the reaction via oxidative decarboxylation to generate a benzylic radical. The resulting flavin semiquinone can reduce the alkyl halide to form a second organic radical within the protein active site, which rapidly engages in C(sp 3 )–C(sp 3 ) bond formation. A variant was engineered to control the stereochemical outcome of this radical–radical coupling event, highlighting the ability of the protein to alter the energetic barrier for a mechanistic step that is traditionally understood to be near barrierless. This work demonstrates that the scope for nonnative reaction mechanisms in biocatalysis far exceeds previously established bounds and has potential to solve a variety of reactivity challenges in cross-coupling chemistry.

biocatalysis↗

Soluble Organic Matter (SOM) analysis of the Hayabusa2 samples: The first results

The Hayabusa2 spacecraft successfully collected the surface and possible sub-surface materials of the asteroid 162173 Ryugu. Ryugu is a C-type asteroid characterized by a low-albedo surface probably consisting of hydrous minerals and carbonaceous materials. [1] The direct optical and spectral analysis of the returned samples indicates that Ryugu material is dominated by hydrous carbonaceous chondrite-like matter (similar to CI chondrites) [2]. Since carbonaceous chondrites have generally yielded various types of organic matter, the collected Ryugu grains are expected to contain diverse types of organic compounds including bio-related molecules. The occurrence of organic compounds in the Ryugu surface will provide clues to the evolution of prebiotic molecules and their preservations associated with aqueous alteration of the primitive asteroid. The initial analysis of soluble organic matter (SOM) of the Hayabusa2-returned samples has been performed by an international team consisting of 32 members. Because the sample amount available for comprehensive SOM analyses is limited, and because the SOM is expected to be present as a complex mixture of various types of organic compounds with very small concentrations of each compound, high-sensitivity and high-resolution analytical techniques have been developed using carbonaceous meteorites [e.g. 3]. Two aggregate samples of the Ryugu grains (A106 and C107) were allocated for the solvent extractions and bulk carbon (C), hydrogen (H), nitrogen (N), sulfur (S) and oxygen (O) measurements. The A106 sample was collected during the 1st sampling in February 2019 and the C107 sample was collected during the 2nd sampling in July 2019 after the Small Carry Impactor (SCI) operation. They consist mainly of particles smaller than 1 mm in diameter, and each sample mass was 38-39 mg. They were firstly investigated spectroscopically in the near infrared wavelength range by the Stone Team prior to the solvent extractions. Other small grains (A0080 and C0057) were also allocated for this study to investigate the spatial distribution of organic compounds on the sample surface. The extraction and analytical measurements implemented by the SOM Team are summarized in Figure 1. Each powder sample was extracted sequentially with non-polar to polar solvents, i.e., hexane, dichloromethane (DCM), methanol (MeOH) and H2O, for non-targeted analysis to reveal the compound composition. Each solvent extract was analyzed by solution state nuclear magnetic resonance (NMR) spectroscopy [4], Fourier transform- ion cyclotron resonance/mass spectrometry (FT-ICR/MS) with ESI and APPI ionization [5] and by high-resolution mass spectroscopy using Orbitrap MS coupled with nano-liquid chromatography (nanoLC/Orbitrap MS) [6], and using two dimensional gas chromatography/mass spectrometry (GC×GC/MS). The extracted residues were passed to the Chemistry Team for further inorganic element analysis. The other powder sample was subjected to the hot water extraction for amino acid analyses including chiral isomer separation, which was performed by three-dimensional (3D) high-performance liquid chromatography (HPLC) with high-sensitivity fluorescence detection (FD) [7] and by HPLC/FD coupled with quadrupole-time of flight/mass spectrometry (QToF/MS) [8]. After the hot water extraction, the residue was split into two halves. One half was further extracted with hydrochloric acid (HCl) to analyze for amino acids in bound-form. The other half was sequentially extracted with DCM/MeOH (1/1) to analyze semi-polar compounds such as polycyclic aromatic hydrocarbons (PAHs) by GC/MS, followed by further extraction with formic acid to analyze polar heterocyclic compounds, and subsequent extraction with HCl to detect bound-form polar compounds. The extracted residues were passed to the IOM Team for the analysis of insoluble organic matter (IOM). Compound-specific stable isotope analyses will be performed using GC/combustion/isotope ratio mass spectrometry (GC/C/IRMS) if the compound concentration is high enough to enable such an isotopic measurement. All extraction procedures were performed on an ISO 6 (Class 100) clean bench inside an ISO 5 (Class 1000) clean room. Baked serpentine powder was also analyzed as a procedural blank. In situ organic compound analysis with the molecular imaging was performed using desorption electrospray ionization (DESI) equipped with Orbitrap MS [9, 10], followed by spatial imaging of organic compounds using ToF/secondary ion mass spectrometry (ToF/SIMS) [11]. The bulk chemical and isotopic compositions of CNS and HO were determined using nano-elemental analysis/isotope ratio mass spectrometry (nanoEA/IRMS) [12] and EA/pyrolysis/IRMS, respectively. We have identified a variety of indigenous organic compounds in the extracts of both A106 and C107 samples. The Ryugu grains host organic molecules under the high-vacuum and cosmic-ray irradiation environment of the asteroid surface. The analysis of extracted molecules is in progress, and the first results will be presented at the symposium.

Hiroshi Naraoka↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗