Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distributed Power Generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Verification and Validation Tests of the Gamma Library of the ARC Software Package (Rev.1)

As part of the verification and validation (V&V) efforts of the Argonne Reactor Code (ARC) software system to support the Versatile Test Reactor (VTR) project of the U.S. Department of Energy (DOE), work has been performed to verify and validate the gamma (or photon) library of the multigroup cross section generation code MC 2 -3 of the ARC system, which is the essential part of the coupled neutron and gamma heating calculations to determine the heat generation rate or power distribution in the core. This V&V study was carried out in three steps: 1) review of the procedures and utility programs for generating the MC 2 -3 gamma library, 2) verification tests of cross sections and KERMA factors by comparing the total heat generation rate of coupled neutron and gamma calculation with that obtained with reaction Q values under the assumption of local gamma energy deposition and by comparing the prompt heat generation rate with that calculated with the MCNP6.2 code, and 3) validation tests of cross sections and KERMA factors by analyzing the ZPPR-15D gamma dose data measured with thermoluminescent dosimeters (TLD).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Architecture, Voltage, and Components for a Turboelectric Distributed Propulsion Electric Grid

The development of a wholly superconducting turboelectric distributed propulsion system presents unique opportunities for the aerospace industry. However, this transition from normally conducting systems to superconducting systems significantly increases the equipment complexity necessary to manage the electrical power systems. Due to the low technology readiness level (TRL) nature of all components and systems, current Turboelectric Distributed Propulsion (TeDP) technology developments are driven by an ambiguous set of system-level electrical integration standards for an airborne microgrid system (Figure 1). While multiple decades' worth of advancements are still required for concept realization, current system-level studies are necessary to focus the technology development, target specific technological shortcomings, and enable accurate prediction of concept feasibility and viability. An understanding of the performance sensitivity to operating voltages and an early definition of advantageous voltage regulation standards for unconventional airborne microgrids will allow for more accurate targeting of technology development. Propulsive power-rated microgrid systems necessitate the introduction of new aircraft distribution system voltage standards. All protection, distribution, control, power conversion, generation, and cryocooling equipment are affected by voltage regulation standards. Information on the desired operating voltage and voltage regulation is required to determine nominal and maximum currents for sizing distribution and fault isolation equipment, developing machine topologies and machine controls, and the physical attributes of all component shielding and insulation. Voltage impacts many components and system performance.

electric faults↗

Grid connection management of distributed generators on the basis of renewable energy sources

The concept of distributed energy of renewable energy sources is becoming increasingly popular. It is not simply supplementary but a real alternative to the conventional power supply from centralized power grids. Distributed electricity generators integrated into the Unified Energy System are a complex system in which the relationship between the observed parameters and the system state is ambivalent and ambiguous. Therefore, the approach to management in automatic control systems based on control of the output parameters is inappropriate in nature. In this case, the elaboration of a control action should be carried out on the basis of data on the current state of the object of control. Issues of the grid connection of distributed generators and control of their process parameters are considered.

14 SOLAR ENERGY↗

Control of energy storage to reduce electric power system off-nominal frequency deviations

A hybrid power generation system is formed by the combination of an energy storage system (ESS) and a rotating synchronous power generator (SPG). Energy is stored in or released from the ESS in response to measurements of the at least one angle parameter, selected from rotor, torque, or power angle of the SPG, to provide active frequency damping of electrical power output. The control of ESS energy exchange increases the stabilizing impact of the SPG inertia on the frequency of electricity in an electrical network or power grid. The hybrid power generation system can have an effective equal area criterion for stability limit that is greater than that of the SPG operating without the ESS. The hybrid power generation system can enable the electrical network to have a greater proportion of variable or distributed energy resource (DER) power generation systems without otherwise exceeding stability limits.

Vartanian, Charles K.↗

Initial Operation of the Nuclear Thermal Rocket Element Environmental Simulator

The Nuclear Thermal Rocket Element Environmental Simulator (NTREES) facility is designed to perform realistic non-nuclear testing of nuclear thermal rocket (NTR) fuel elements and fuel materials. Although the NTREES facility cannot mimic the neutron and gamma environment of an operating NTR, it can simulate the thermal hydraulic environment within an NTR fuel element to provide critical information on material performance and compatibility. The NTREES facility has recently been upgraded such that the power capabilities of the facility have been increased significantly. At its present 1.2 MW power level, more prototypical fuel element temperatures nay now be reached. The new 1.2 MW induction heater consists of three physical units consisting of a transformer, rectifier, and inverter. This multiunit arrangement facilitated increasing the flexibility of the induction heater by more easily allowing variable frequency operation. Frequency ranges between 20 and 60 kHz can accommodated in the new induction heater allowing more representative power distributions to be generated within the test elements. The water cooling system was also upgraded to so as to be capable of removing 100% of the heat generated during testing In this new higher power configuration, NTREES will be capable of testing fuel elements and fuel materials at near-prototypic power densities. As checkout testing progressed and as higher power levels were achieved, several design deficiencies were discovered and fixed. Most of these design deficiencies were related to stray RF energy causing various components to encounter unexpected heating. Copper shielding around these components largely eliminated these problems. Other problems encountered involved unexpected movement in the coil due to electromagnetic forces and electrical arcing between the coil and a dummy test article. The coil movement and arcing which were encountered during the checkout testing effectively destroyed the induction coil in use at the time and resulted in NTREES being out of commission for a couple of months while a new stronger coil was procured. The new coil includes several additional pieces of support structure to prevent coil movement in the future. In addition, new insulating test article support components have been fabricated to prevent unexpected arcing to the test articles. Additional activities are also now underway to address ways in which the radial temperature profiles across test articles may be controlled such that they are more prototypical of what they would encounter in an operating nuclear engine. The causes of the temperature distribution problem are twofold. First, the fuel element test article is isolated in NTREES as opposed to being in the midst of many other mostly identical fuel elements in a nuclear engine. As a result, the fuel element heat flux boundary conditions in NTREES are far from adiabatic as would normally be the case in a reactor. Second, induction heating skews the power distribution such that power is preferentially deposited near the outside of the fuel element. Nuclear heating, conversely, deposits its power much more uniformly throughout the fuel element. Current studies are now looking at various schemes to adjust the amount of thermal radiation emitted from the fuel element surface so as to essentially vary the thermal boundary conditions on the test article. It is hoped that by properly adjusting the thermal boundary conditions on the fuel element test article, it may be possible to substantially correct for the inappropriate radial power distributions resulting from the induction heating so as to yield a more nearly correct temperature distribution throughout the fuel element.

Emrich, William J., Jr.↗

Proposal and Development of a High Voltage Variable Frequency Alternating Current Power System for Hybrid Electric Aircraft

The development of ultra-efficient commercial vehicles and the transition to low-carbon emission propulsion are seen as thrust paths within NASA Aeronautics. A critical enabler to these paths comes in the form of hybrid-electric propulsion systems. For megawatt-class systems, the best power system topology for these hybrid-electric propulsion systems is debatable. Current proposals within NASA and the Aero community suggest using a combination of AC and DC for power transmission. This paper proposes an alternative to the current thought model through the use of a primarily high voltage AC power generation, transmission, and distribution systems, supported by the Convergent Aeronautics Solutions (CAS) Project. This system relies heavily on the use of dual-fed induction machines, which provide high power densities, minimal power conversion, and variable speed operation. The paper presents background on the project along with the system architecture, development status and preliminary results.

Propulsion↗

Power electronic applications for Space Station Freedom

NASA plans to orbit a permanently manned space station in the late 1990s, which requires development and assembly of a photovoltaic (PV) power source system to supply up to 75 kW of electrical power average during the orbital period. The electrical power requirements are to be met by a combination of PV source, storage, and control elements for the sun and eclipse periods. The authors discuss the application of power electronics and controls to manage the generation, storage, and distribution of power to meet the station loads, as well as the computer models used for analysis and simulation of the PV power system. The requirements for power source integrated controls to adjust storage charge power during the insolation period current limiting, breaker interrupt current values, and the electrical fault protection approach are defined. Based on these requirements, operating concepts have been defined which then become drivers for specific system and element design.

Pickrell, Roy L.↗

Considerations for a Medium-Voltage DC Electrolysis Testbed

Here we present the results of a study focused on the feasibility of using Medium Voltage DC (MVDC) power distribution from wind power generation to electrolyzers for hydrogen production. This approach, using hybrid energy generation in a MVDC microgrid, offers many advantages. These include possible improvements in efficiency, reliability and installation cost compared to a more typical state-of-the-art AC distribution configuration. It also eliminates the need for transformers, which have recently been subject to price volatility and availability concerns. This study highlights the practical feasibility of MVDC distribution networks for integrating various energy sources, offering improved efficiency and reduced system complexity compared to conventional AC-based solutions. Future work will focus on enhancing fault protection strategies, scaling the system to larger renewable installations, and conducting hardware implementation at the National Renewable Energy Laboratory's (NREL) Flatirons Campus (FC). In the sections that follow we show that a DC Collection and Distribution System (DC CDS) reduces the losses associated with the electrical conversion / distribution process relative to a state-of-the-art AC approach, improving overall efficiency by 5%. On the qualitative side, reducing the number of conversion stages is likely to improve reliability, reduce capital investment cost, and enable simpler control algorithms to be used, and reduced risk of instabilities and malfunctions.

08 HYDROGEN↗

Storm-DEPART (Damage Estimate Prediction and Recovery Tool)

Storm-DEPART (Damage Estimate Prediction and Restoration Tool): Each year hurricanes and tropical storms in the United States damage critical infrastructure assets, disrupt the services they provide, and cause millions to billions of dollars in economic impacts due to extended recovery times. The Storm-DEPART tool and analytical output enable more impactful data-driven decision-making capabilities and strengthen national-level disaster preparedness, response, and recovery. Storm-DEPART, built through multi-month collaboration between Entergy and INL, combines Entergy’s critical infrastructure inventory data with weather forecasts to predict damages to Electric utility’s assets due to natural disasters and the estimated recovery support needed, including time, materials, and resource allocation. In the event of an approaching hurricane, this innovative solution can assess potential damage to power generation capacity, transmission grids, distribution networks, and communications assets from wind bands, storm surge, and flooding. With more effective predictions, Entergy can more efficiently allocate resources to mitigate impacts and optimize recovery for customers. Storm-DEPART also allows Electric utilities the ability to apply a planning scenario and model expected damage to better inform infrastructure restoration needs leading to enhance system resiliency. The technology is fully transferrable to other electric utilities with the same damage estimating challenges. The INL team is working on the evolution of Storm-DEPART to include ice event damage prediction framework.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power conditioning equipment for a thermoelectric outer planet spacecraft, volume 1, book 1

Equipment was designed to receive power from a radioisotope thermoelectric generator source, condition, distribute, and control this power for the spacecraft loads. The TOPS mission, aimed at a representative tour of the outer planets, would operate for an estimated 12 year period. Unique design characteristics required for the power conditioning equipment results from the long mission time and the need for autonomous on-board operations due to large communications distances and the associated time delays of ground initiated actions. The salient features of the selected power subsystem configuration are: (1) The PCE regulates the power from the radioisotope thermoelectric generator power source at 30 vdc by means of a quad-redundant shunt regulator; (2) 30 vdc power is used by certain loads, but is more generally inverted and distributed as square-wave ac power; (3) a protected bus is used to assure that power is always available to the control computer subsystem to permit corrective action to be initiated in response to fault conditions; and (4) various levels of redundancy are employed to provide high subsystem reliability.

Andrews, R. E.↗

A Three-Phase Microgrid Restoration Model Considering Unbalanced Operation of Distributed Generation

Recent severe outages highlight the urgency of improving grid resiliency in the U.S. Microgrid formation schemes are proposed to restore critical loads after outages occur. Most distribution networks have unbalanced configurations that are not represented in sufficient detail by single-phase models. This study provides a microgrid formation plan that adopts a three-phase network model to represent unbalanced distribution networks. The problem formulation has a quadratic objective function with mixed-integer linear constraints. The three-phase network model enables us to examine the three-phase power outputs of distributed generators (DGs), preventing unbalanced operation that might trip DGs. Because the DG unbalanced operation constraint is non-convex, an iterative process is presented that checks whether the unbalanced operation limits for DGs are satisfied after each iteration of optimization. We also develop a relatively conservative linear approximation on the unbalanced operation constraint to handle larger networks. Compared with the iterative solution process, the conservative linear approximation is able to accelerate the solution process at the cost of sacrificing optimality to a limited extent. Simulation in the IEEE 34 node and IEEE 123 test feeders indicate that the proposed method yields more practical microgrid formations results. In addition, this paper explores the coordinated operation of DGs and energy storage (ES) installations. The unbalanced three-phase outputs of ESs combined with the relatively balanced outputs of DGs could supply unbalanced loads. In conclusion, the case study also validates the DG-ES coordination.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Analysis of a Vortex Type Magnetohydrodynamic Induction Generator

Consideration it is given to the performance to the characteristics of an AC magnetohydrodynamic power generator, A rotating magnetic field is imposed on the vortex flow of an electrically conducting fluid, which is injected tangentially into an annulus formed by two nonconducting concentric cylinders and two nonconducting end plates. A perturbation technique is used to determine the two dimensional velocity and three dimensional electromagnetic field and current distributions. Finally, the generated power, the ohmic losses, the effective power and the electrical efficiency of the converter system are calculated.

MAGNETOHYDRODYNAMIC GENERATOR↗

Network, system, and status software enhancements for the autonomously managed electrical power system breadboard. Volume 1: Project summary

This volume (1 of 4) gives a summary of the original AMPS software system configuration, points out some of the problem areas in the original software design that this project is to address, and in the appendix collects all the bimonthly status reports. The purpose of AMPS is to provide a self reliant system to control the generation and distribution of power in the space station. The software in the AMPS breadboard can be divided into three levels: the operating environment software, the protocol software, and the station specific software. This project deals only with the operating environment software and the protocol software. The present station specific software will not change except as necessary to conform to new data formats.

Mckee, James W.↗

Sequential Service Restoration for Unbalanced Distribution Systems and Microgrids

The resilience and reliability of modern power systems are threatened by increasingly severe weather events and cyber-physical security events. An effective restoration methodology is desired to optimally integrate emerging smart grid technologies and pave the way for developing self-healing smart grids. In this paper, a sequential service restoration (SSR) framework is proposed to generate restoration solutions for distribution systems and microgrids in the event of large-scale power outages. The restoration solution contains a sequence of control actions that properly coordinate switches, distributed generators, and switchable loads to form multiple isolated microgrids. The SSR can be applied for three-phase unbalanced distribution systems and microgrids and can adapt to various operation conditions. Mathematical models are introduced for three-phase unbalanced power flow, voltage regulators, transformers, and loads. Furthermore, the SSR problem is formulated as a mixed-integer linear programming model, and its effectiveness is evaluated via the modified IEEE 123 node test feeder.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Coordination of Energy Storage and Distributed Generation for Voltage Control and Peak-valley Filling

The increasing penetration of distributed energy resources (DERs) in distribution network (DN) poses challenges on voltage control. In addition, the growing integration of DERs also reshapes the traditional load profile. To comprehensively address the voltage control and peak-valley filling in DN, this paper proposes a model predictive control (MPC) based optimization framework. The proposed method can achieve coordinated voltage control and peak-valley filling by adjusting the reactive power output from distributed generations (DGs) and the charging/discharging of energy storage systems (ESS). The performance of the proposed method is demonstrated by simulations on a modified IEEE-123 bus system.

Zhang, Zhengfa [University of Tennessee, Knoxville↗

Distributed Energy Planning for Climate Resilience

At various levels of government across the United States and globally climate resilient solutions are being adopted and implemented. Solutions vary based on predicted hazards, community context, priorities, complexity, and available resources. Lessons are being learned through the implementation process, which can be replicated regardless of level or type of government entity carrying out the resiliency planning. Through a number of analyses and technical support across the world, NREL has learned key lessons related to resilience planning associated with power generation and water distribution. Distributed energy generation is a large factor in building resilience with clean energy technologies and solutions. The technical and policy solutions associated with distributed energy implementation for resilience fall into a few major categories, including spatial diversification, microgrids, water-energy nexus, policy, and redundancy.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Peer-to-Peer Energy Trading under Network Constraints Based on Generalized Fast Dual Ascent

We report the wide deployment of renewable energy resources, combined with a more proactive demand-side management, is inducing a new paradigm in both power system operation and electricity market trading, which especially boosts the emergence of the peer-to-peer (P2P) market. A more flexible local market mechanism is highly desirable in response to fast changes in renewable power generation at the distribution network level. Moreover, large-scale implementation of P2P energy trading inevitably affects the secure and economic operation of the distribution network. This paper presents a new P2P electricity trading framework with distribution network security constraints considered using the generalized fast dual ascent method. First, an event-driven local P2P market framework is presented to facilitate short-term or immediate local energy transactions. Then, the sensitivity analysis of nodal voltage and network loss with respect to nodal power injections is used to evaluate the impacts of P2P transactions on the distribution network, which ensures the secure operation of the distribution system. Thereby, the external operational constraints are internalized, and the cost of P2P energy trading can be appropriately allocated in an endogenous way. Moreover, a generalized fast dual ascent method is employed to implement distributed market-clearing efficiently. Finally, numerical results indicate that the proposed model could guarantee secure operation of the distribution system with P2P energy trading, and the solution method enjoys good convergence performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Virtual Agents-Based Attack-Resilient Distributed Control for Islanded AC Microgrid

Due to its dependence on a communication network, distributed secondary control of microgrids is susceptible to denial-of-service (DoS) attacks in channel shutdown mode, which may negatively impact the network connectivity and thus deteriorate the coordination and power sharing among distributed generators (DGs). Honeypot is a common method for cyber deception by introducing fake targets. However, in the context of microgrid, the misleading information spread by honeypots will also impact the system performance. This paper proposes an attack-resilient distributed control for AC microgrids utilizing virtual agents (VAs) to counteract both DoS edge and node attacks. The VAs are designed to not impact the system’s steady state during normal operation but to share information among neighboring real agents and serve as dummy targets for DoS attacks. The control with VAs is implemented by a primal-dual gradient based distributed algorithm to efficiently obtain a practical solution for voltage/frequency regulation and power sharing. The simulation results on a 4-DG test system and a modified IEEE 34-bus system show that 1) VAs do not impact the normal functionality of the test system, and 2) deploying VAs can enhance the resilience of the microgrid control against DoS edge and node attacks.

24 POWER TRANSMISSION AND DISTRIBUTION↗