Accelerating Cost-Effective Deployment of Solar Generation on the Distribution Grid.
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
An exemplary system, method, and computer-accessible medium for determining a property(ies) regarding an electrical grid(s) can be provided, which can include, for example, receiving a video(s) of the electrical grid(s), determining a flicker(s) in the electrical grid(s) based on the video(s), and determining the property(ies) based on the flicker(s). The flicker(s) can be a 120 Hertz flicker. The flicker(s) can be a flicker in a light(s) recorded in the video(s). A frequency and a phase of the flicker(s) can be determined.
Widespread adoption of Electric Vehicles (EVs) for light, medium, and heavy-duty applications has gained significant interest. Based on ownership and user preferences, light duty and local delivery medium-duty EVs are typically connected to grid distribution networks whereas larger medium duty and heavy-duty EVs are typically connected to distribution or even sub-transmission networks. Challenges with at-scale EVs and charging infrastructure supporting them include interoperability, distribution network upgrades, surge in demand charges, power quality issues, voltage stability, etc. Based on real-world data, steady-state and dynamic assessments of light-duty EV charging with a focus on DC Fast Charging (DCFC) for weak distribution grids is presented. Three main areas of contributions in this paper include - steady state and dynamic power quality measurements and assessments using real world data, transient assessments of light duty EV integration with weak distribution networks (IEEE 13 node feeder system) under grid-connected and microgrid modes, and formulation of an intelligent charging decision algorithm to enable an impact-minimal charging.
Widespread adoption of Electric Vehicles (EVs) for light, medium, and heavy duty (LD, MD, and HD) applications has gained significant interest. Based on ownership and user preferences, LD and local delivery MD EVs are typically connected to grid distribution networks whereas larger MD and HD EVs will be connected to distribution or even sub-transmission networks. Challenges with at-scale EVs and charging infrastructure supporting it include interoperability, distribution network upgrades, demand charges, power quality, voltage stability, etc. Based on real-world data, steady-state and dynamic assessments of LD EV adoption for weak distribution grids is presented.
Electrifying medium- and heavy-duty trucks is critical to decarbonizing the transportation sector. Energy needs of electric trucks will likely require megawatt-scale charging stations, which could significantly stress the electric distribution grid. Distributed energy resources (DER) can alleviate this stress and reduce charging costs with proper management. To that end, this work develops a hierarchical predictive control algorithm for future multi-port megawatt-scale charging stations that can provide real-time energy management for stations, decide charging rates, dispatch energy storage system (ESS), and provide grid voltage support. We integrate three algorithmic components: (i) an energy management optimization (EMO) that provides supervisory control to DER assets and charging loads at minute scale, (ii) a real-time energy management system (RT-EMS) that heuristically compensates for fast disturbances at sub-second scale, and (iii) a model predictive control (MPC)-based battery management system (BMS) that communicates future charging demands to the EMO, to manage the overall megawatt-scale site. Additionally, validation in a controller hardware-in-the-loop (CHIL) environment shows that the hierarchical controller can reduce the total energy consumption from the grid by approximately 28% compared to an uncontrolled case for the station configuration in this paper, without impacting charging time.
The power system landscape is presently undergoing a dramatic change with the rapid integration of numerous distributed energy resources (DERs) at the grid edge. Broadly, we consider grid-edge DERs as any electricity source, storage, and demand response program connected to the medium-to-low-voltage distribution system.
The health of a distribution grid is maintained by a distribution management system (DMS). Before the rise of distributed energy resource (DER), the DMS primarily managed the unidirectional power flow through the distribution grid from external sources (e.g. power brought from a large generating plant to the distribution grid by a transmission grid). Now, a typical DMS will utilize distributed energy resource manage systems (DERMS) to account for DER such as rooftop solar, community solar, and wind turbines. Each DERMS is responsible for an area of the distribution grid, issuing commands to the associated real-time automation controller (RTAC) to regulate power flow and maintain health of that section of the grid.
This paper provides a method to assess the impact of multiple mitigation solutions including distribution grid upgrades and advanced control technologies on increasing distributed PV penetration in distribution feeders, and thus paves the way to estimate the costs needed for reaching certain PV penetration level. Based on three assumptions of creating increasing PV penetration scenarios, this paper first studies the distribution impact of PV power and quantifies the PV hosting capacity in distribution feeders. Then, it studies multiple mitigation solutions to increase PV penetration on distribution feeders. These mitigation solutions are implemented in a sequential manner according to their typical costs. The proposed study is demonstrated on two representative distribution feeders.
This paper presents a method to assess the technical impacts of a series of distribution system mitigations for integrating increasing penetrations of distributed generation from solar photovoltaics (DGPV). Solutions considered include distribution grid upgrades and advanced control technologies. This study helps pave the way to estimate the distribution integration costs needed to reach various PV penetration levels. The approach uses three stream-lined, bounding scenarios for increased PV penetration patterns. It begins by studying the distribution impact of PV power and quantifying the PV hosting capacity. Then, it studies multiple mitigation solutions to increase PV penetration on distribution feeders. These mitigation solutions are implemented in a sequential manner according to their typical costs. The proposed technique is demonstrated on two representative distribution feeders.
A Distribution Management System (DMS) is responsible for monitoring and maintaining the health of a distribution grid. Common DMS applications include fault location isolation and service restoration, on-line power flow (OLPF), volt/VAR optimization (VVO), and switch order management. These systems were developed primarily in the area of top-down, unidirectional power flow, with large centralized generating plants moving electricity through the transmission grid and into the distribution grid from and thence to consumers. The recent and ongoing addition of distributed energy resources (DER) to the grid, including rooftop and community solar and wind, means that power is now flowing into the distribution grid from the edge, which complicates the functioning of the DMS. To ameliorate this problem, DMS use distributed energy resource management systems (DERMS) to control DER such as solar inverters. DERMS comprise software management tools that allow management and near real-time control of an array of DER. DERMS control devices and grid services including smart inverters, capacitor banks, on-load tap changes, voltage regulators, and customer loads.
Escalating deployment of PV and grid-edge devices on the distribution grid has increased the sustainability and efficiency of the electric grid. However, the increasing number of distributed energy resources (DERs) deployed creates a heightened cyber-physical interdependency on the distribution grid and thus creates more vectors for cyber-attacks to exploit through information and communication technology (ICT) systems and networks. For example, control signal packets can be modified, intercepted, or corrupted due to vulnerabilities in communication protocols used by microgrid controllers and grid edge devices for power control. Therefore, to mitigate and prevent cyber-attacks on grid edge devices and the inverter-based resources connected to the distribution grid, the U.S. Department of Solar Energy Technologies Office (SETO) awarded funding to the National Renewable Energy Laboratory and Sandia National Laboratory (SNL) to research, develop, and harmonize cybersecurity standards for Photovoltaic (PV) systems and for other kinds of DERs. To help develop a standard for DER cybersecurity, NREL established certification recommendations and test cases, in consensus with the solar industry and UL, for ensuring intrinsic design security for DERs. These recommendations were developed to bolster the cybersecure functionalities such as TLS, MAC, CRL, session resumption/renegotiation, and password, system, and service security management within the DER devices. The proposed test cases verify authentication, authorization, confidentiality, and data integrity for data and communications of DERs that use Transmission Control Protocol/Internet Protocol (TCP/IP). They were also developed to protect DER communications from eavesdropping, replay, man-in-the-middle, denial of service (DoS), spoofing through security certificates, least-privilege violation, and brute-force credentials. This report, which has been validated and reviewed by UL, expands upon those test cases to provide DER cybersecurity certification recommendations which increase DER resiliency and help to mitigate cyber-attacks. UL's collaboration with NREL and approval of this document will accelerate the adoption of a UL standard for DER cybersecurity.
Distribution management systems (DMSs) are increasingly used by distribution system operators (DSOs) to manage the distribution grid and to monitor the status of both power imported from the transmission grid and power generated locally by a distributed energy resource (DER), to ensure that power flows and voltages along the feeders are maintained within designed limits and that appropriate measures are taken to guarantee service continuity and energy security. When microgrids are deployed and interconnected to the distribution grids, they will have an impact on the operation of the distribution grid. The challenge is to design this interconnection in such a way that it enhances the reliability and security of the distribution grid and the loads embedded in the microgrid, while providing economic benefits to all stakeholders, including the microgrid owner and operator and the distribution system operator.
The precise knowledge regarding the state of the power grid is important in order to ensure optimal and reliable grid operation. Specifically, knowing the state of the distribution grid becomes increasingly important as more renewable energy sources are connected directly into the distribution network, increasing the fluctuations of the injected power. In this paper, we consider the case when the distribution grid becomes partially observable, due to for example cyber attacks, and the state estimation problem is under-determined. We present a new methodology that leverages a deep neural network (DNN) to estimate the grid state. The standard DNN training method is modified to explicitly incorporate the physical information of the grid topology and line/shunt admittance. We show that our method leads to a superior accuracy of the estimation when compared to the case when no physical information is provided. Finally, we compare the performance of our method to the standard state estimation approach, which is based on the weighted least squares with pseudo-measurements, and show that our method performs significantly better with respect to the estimation accuracy.
Despite the rapid growth of solar energy, we still lack a dynamic, high-fidelity database that tracks the spatiotemporal variations of solar PVs and their associated infrastructures across different places at a spatially resolved scale. The absence of such data presents a barrier to various applications such as solar PV growth projection, solar energy integration, solar incentive design, and climate risk assessment. In this project, we aim to bridge this gap by developing AI-based algorithms to extract granular information about solar PV installations and their associated infrastructures (i.e., distribution grids) from widely available unstructured data like remote sensing images and street views. As a result, we have built the Solar Energy Atlas, a fine-grained, large-scale geospatial overlay of distributed solar PVs and distribution grids. On top of it, we have advanced the understanding of solar adoption and distribution grid vulnerability to climate-induced extremes. Our major contributions can be summarized as follow: (1) By developing new AI algorithms, we have built the most comprehensive solar PV spatiotemporal database covering the entire US. This is the first time we obtained the exact GPS locations, size, subtype, and installation year information for rooftop solar PVs across the US. This database can be used for solar PV growth projection, solar energy integration, solar energy policy analysis and design, and spatially-resolved climate risk assessment. (2) Leveraging this database, we have uncovered the socioeconomic driving factors that are correlated with earlier onset of solar adoption and higher saturated adoption levels. We have identified the heterogeneity in the effects of different types of financial incentives on solar adoption and provided implications for tailoring incentive design based on local income levels to promote equitable solar adoption. (3) We have developed a distribution grid GIS mapping algorithm which can obtain granular geospatial and topology information about distribution grids using multi-modal open data, reducing the dependency on hard-to-obtain smart meter data of conventional approaches. It shows effectiveness in both the U.S. and Sub-Saharan Africa. Using this algorithm, we have uncovered the non-uniform vulnerability of distribution grids to wildfires in California in the aspects of undergrounding protection and Distributed Energy Resources (DER) preparedness. This has provided important implications for improving the affordability and equity of grid adaptation approaches. (3) We have made our produced database publicly available and provided user-friendly interface to enable various stakeholders and the general public to interact with the data. We have also integrated the produced data into the Data Commons platform to enable the public to access the data and correlate it with other location-specific characteristics simply using natural language as queries. The impact of our project is three-fold: (1) New algorithms for mapping solar PVs and distribution grids across space and time, which are open source to facilitate researchers and industry; (2) New databases of solar PVs and distribution grids that have been made publicly available for engineering, social, and policy applications; (3) New understandings and actionable insights on the potential approaches to promoting solar adoption and reducing energy infrastructure vulnerabilities. In this report, we start by discussing the project background and motivation (section 5), followed by the overview of project objectives (section 6). Results and discussion for each task are presented in section 7. Significant accomplishments are summarized in section 8. This report will be concluded by discussing the paths forwards (section 9), products (section 10), and team roles (section 11).
The evolution of networks into more distributed, self-reliant nodes has mitigated single-point failures that plagued traditional centralized networks. Applied to power grids, distributed systems can increase the integrity and availability of grid services while also offering a power management solution. However, while distributed networks provide scalability, security, and sustainability compared to centralized networks, their distributed nature makes them harder for anomaly detection and prevention. Incorporating a Distributed Trust Model (DTM) System into an Energy Grid of Things Distributed Energy Resource Management System (EGOT DERMS) allows grid participants to be characterized and their communication to be analyzed for possible attacks. A Trust Model simulator is needed to evaluate and improve the DTM System.Trustworthiness is calculated using a Trust Model. While many trust models exist, most only consider 2-3 matrices to evaluate trust. The TM proposed in this thesis uses a Metric Vector of Trust (MVoT) monitoring 17 parameters when assessing trust. Moreover, unlike standard trust models, the proposed trust model establishes a method to test the trust between various actors within the network and probe the trust model itself. Using a Trust Model Simulator, MVoT calaculations, initial values, and parameters are fine-tuned to achieve high-confidence message classifications and minimize false positives. The DTM System and Trust Mode Simulation Suite allow for distributed trust evaluation with a real-time classification of EGOT DERMS actors, providing additional security for distributed systems.
Greening the Grid provides technical assistance to energy system planners, regulators, and grid operators to overcome challenges associated with integrating variable renewable energy into the grid. This document introduces a brief overview of common technical impacts of PV on distribution systems and operations, as well as emerging strategies for successfully addressing some of the priority issues.
In this report, a scalable, decentralized, sensor-oriented communication blueprint is introduced. The proposed architecture has been specifically designed to support the mass deployment of sensors and also enable data consumers to access the underlying data streams using a distributed systems approach. With the proposed approach, sensors and data clients can be decoupled from the physical communication infrastructure and migrated into a modern, software-defined infrastructure ecosystem that can be configured to suit the end application’s requirements. In its current iteration, this blueprint defines the interactions, processes, and expected outcomes that each individual component within the architecture must support the overall ecosystem’s needs. Within this work, such an assembly of services is called the data bus; it represents the heart of the distributed grid sensing services architecture, a multiyear project that aims to design, implement, and test a reference sensor-data dissemination network that can support the needs of the extended grid state. We expect this blueprint to guide our future implementation efforts