Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dose Rate Calculations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Human exposure to large solar particle events in space

Whenever energetic solar protons produced by solar particle events traverse bulk matter, they undergo various nuclear and atomic collision processes which significantly alter the physical characteristics and biologically important properties of their transported radiation fields. These physical interactions and their effect on the resulting radiation field within matter are described within the context of a recently developed deterministic, coupled neutron-proton space radiation transport computer code (BRYNTRN). Using this computer code, estimates of human exposure in interplanetary space, behind nominal (2 g/sq cm) and storm shelter (20 g/sq cm) thicknesses of aluminum shielding, are made for the large solar proton event of August 1972. Included in these calculations are estimates of cumulative exposures to the skin, ocular lens, and bone marrow as a function of time during the event. Risk assessment in terms of absorbed dose and dose equivalent is discussed for these organs. Also presented are estimates of organ exposures for hypothetical, worst-case flare scenarios. The rate of dose equivalent accumulation places this situation in an interesting region of dose rate between the very low values of usual concern in terrestrial radiation environments and the high-dose-rate values prevalent in radiation therapy.

Townsend, L. W.↗

Defect-specific strength factors and superposition model for predicting strengthening of ion irradiated Fe18Cr alloy

Here, a high-purity binary alloy Fe18Cr was subjected to heavy-ion irradiation in order to provide improved understanding of the irradiation effect on radiation hardening associated with dislocation loop and network formation, α’ precipitation. The specimens were irradiated with 8 MeV Fe ions (~2 μm ion range) to midrange doses of 0.37 and 3.7 dpa at 300, 350 and 450 °C using dose rates of ~10 –5 –10 –3 dpa/s. Nanoindentation testing was performed to extract the bulk equivalent hardness at low depth from these ion irradiated specimens. High-quality transmission electron microscopy (TEM) images were acquired by utilizing a flash electropolishing method on the Focused Ion Beam (FIB) prepared liftouts. An accurate calculation of the strength factor was provided based on detailed TEM characterization of the irradiated microstructures. A newly refined hardening superposition method was applied to combine the strengthening components from each microstructure. The good agreement between microstructure predicted strength and measured strength further demonstrated the fidelity to use hardening model to quantify the mechanical properties of ion irradiated materials.

36 MATERIALS SCIENCE↗

Radiation experiments on Cosmos 2044: K-7-41, parts A, B, C, D, E

The Cosmos 2044 biosatellite mission offered the opportunity for radiation measurements under conditions which are seldom available (an inclination of 82.3 deg and attitude of 294 x 216 km). Measurements were made on the outside of the spacecraft under near-zero shielding conditions. Also, this mission was the first in which active temperature recorders (the ATR-4) were flown to record the temperature profiles of detector stacks. Measurements made on this mission provide a comparison and test for modeling of depth doses and LET spectra for orbital parameters previously unavailable. Tissue absorbed doses from 3480 rad (252 rad/d) down to 0.115 rad (8.33 mrad/d) were measured at different depths (0.0146 and 3.20 g/sq cm, respectively) with averaged TLD readings. The LET spectra yielded maximum and minimum values of integral flux of 27.3 x 10(exp -4) and 3.05 x 10(exp -4)/sq cm/s/sr, of dose rate of 7.01 and 1.20 mrad/d, and of dose equivalent rate of 53.8 and 11.6 mrem/d, for LET(sub infinity)-H2O is greater than or equal to 4 keV/micron. Neutron measurements yielded 0.018 mrem/d in the thermal region, 0.25 mrem/d in the resonance region and 3.3 mrem/d in the high energy region. The TLD depth dose and LET spectra were compared with calculations from the modeling codes. The agreement is good but some further refinements are in order. In comparing measurements on Cosmos 2044 with those from previous Cosmos missions (orbital inclinations of 62.8 deg) there is a greater spread (maximum to minimum) in depth doses and an increased contribution from GCRs, and higher LET particles, in the heavy particle fluxes.

Frank, A. L.↗

Experiment K-7-41: Radiation Experiments on Cosmos 2044

The Cosmos 2044 biosatellite mission offered the opportunity for radiation measurements under conditions which are seldom available (an inclination of 82.3 degrees and altitude of 294 x 216 km). Measurements were made on the outside of the spacecraft under near-zero shielding conditions. Also, this mission was the first in which active temperature recorders (the ATR-4) were flown to record the temperature profiles of detector stacks. Measurements made on this mission provide a comparison and test for modeling of depth doses and LET spectra for orbital parameters previously unavailable. Tissue absorbed doses from 3480 rad (252 rad/d) down to 0.115 rad (8.33 mrad/d) were measured at different depths (0.0146 and 3.20 g/sq. cm, respectively) with averaged TLD readings. The LET spectra yielded maximum and minimum values of integral flux of 27.3 x 10-4 and 3.05 x 10(exp -4) cm(exp -2).s(exp -1).sr(exp -4) of dose rate of 7.01 and 1.20 mrad/d, and of dose equivalent rate of 53.8 and 11.6 mrem/d, for LET(infinity).H2O is greater than or equal to 4 keV/micro-m. Neutron measurements yielded 0.018 mremld in the thermal region, 0.25 mrem/d in the resonance region and 3.3 mrem/d in the high energy region. The TLD depth dose and LET spectra have been compared with calculations from the modeling codes. The agreement is good but some further refinements are in order. In comparing measurements on Cosmos 2044 with those from previous Cosmos missions (orbital inclinations of 62.8 degrees) there is a greater spread (maximum to minimum) in depth doses and an increased contribution from GCR's, and higher LET particles, in the heavy particle fluxes.

Benton, E. V.↗

Development of a MOOSE-based crystal plasticity model with irradiation defect evolution for irradiation creep in 316

Irradiation creep and irradiation swelling are two of the lifetime limiting factors for structural materials in nuclear reactors. These mechanical effects are driven by irradiation defect evolution and the interaction of those defects with dislocations in the microstructure. We present here a coupled cluster dynamics – crystal plasticity approach to model irradiation swelling and creep behavior in 316 SS. The time-dependent evolution of irradiation defects is calculated with a cluster dynamics approach and passed to the crystal plasticity model to compute the dislocation evolution. We show the impact of the irradiation defect evolution on the stress state in the material, which drives inelastic deformation through dislocation motion. The inelastic deformation in the 316 SS is dependent on the dose rate, where the inelastic deformation driven by the early-stage irradiation defect evolution determines the mechanical behavior of the 316 SS.

316 Stainless Steels↗

Dosimetric delivery validation of dynamically collimated pencil beam scanning proton therapy

Pencil beam scanning (PBS) proton therapy target dose conformity can be improved with energy layer-specific collimation. One such collimator is the dynamic collimation system (DCS), which consists of four nickel trimmer blades that intercept the scanning beam as it approaches the lateral extent of the target. While the dosimetric benefits of the DCS have been demonstrated through computational treatment planning studies, there has yet to be experimental verification of these benefits for composite multi-energy layer fields. The objective of this work is to dosimetrically characterize and experimentally validate the delivery of dynamically collimated proton therapy with the DCS equipped to a clinical PBS system. Approach. Optimized single field, uniform dose treatment plans for 3 × 3 × 3 cm 3 target volumes were generated using Monte Carlo dose calculations with depths ranging from 5 to 15 cm, trimmer-to-surface distances ranging from 5 to 18.15 cm, with and without a 4 cm thick polyethylene range shifter. Treatment plans were then delivered to a water phantom using a prototype DCS and an IBA dedicated nozzle system and measured with a Zebra multilayer ionization chamber, a MatriXX PT ionization chamber array, and Gafchromic™ EBT3 film. Main results. For measurements made within the SOBPs, average 2D gamma pass rates exceeded 98.5% for the MatriXX PT and 96.5% for film at the 2%/2 mm criterion across all measured uncollimated and collimated plans, respectively. For verification of the penumbra width reduction with collimation, film agreed with Monte Carlo with differences within 0.3 mm on average compared to 0.9 mm for the MatriXX PT. Significance. We have experimentally verified the delivery of DCS-collimated fields using a clinical PBS system and commonly available dosimeters and have also identified potential weaknesses for dosimeters subject to steep dose gradients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measurements of the linear energy transfer spectra on the Mir orbital station and comparison with radiation transport models

A tissue equivalent proportional counter designed to measure the linear energy transfer spectra (LET) in the range 0.2-1250 keV/micrometer was flown in the Kvant module on the Mir orbital station during September 1994. The spacecraft was in a 51.65 degrees inclination, elliptical (390 x 402 km) orbit. This is nearly the lower limit of its flight altitude. The total absorbed dose rate measured was 411.3 +/- 4.41 microGy/day with an average quality factor of 2.44. The galactic cosmic radiation (GCR) dose rate was 133.6 microGy/day with a quality factor of 3.35. The trapped radiation belt dose rate was 277.7 microGy/day with an average quality factor of 1.94. The peak rate through the South Atlantic Anomaly was approximately 12 microGy/min and nearly constant from one pass to another. A detailed comparison of the measured LET spectra has been made with radiation transport models. The GCR results are in good agreement with model calculations; however, this is not the case for radiation belt particles and again points to the need for improving the AP8 omni-directional trapped proton models.

Mir Project↗

The importance of delayed neutron precursors in gamma dose calculations for activated primary heat exchanger components in the Molten Salt Breeder Reactor

The Molten Salt Reactor (MSR) Multiphysics Applications technical area in the Nuclear Energy Advanced Modeling and Simulation program has supported the development of 3D Monte Carlo models of the Molten Salt Breeder Reactor (MSBR) over the last couple of years. This MSBR model was previously run with the Shift Monte Carlo code to perform radiation shielding calculations in the reactor cell area. The MSBR is a 2250 MWth (1000 MWe) liquid-fueled molten salt reactor design developed at Oak Ridge National Laboratory in the 1970s. Determining the source terms from activated primary heat exchanger (HX) components is important because delayed and prompt neutron fluxes incident on these components affect the dose rate in the primary HX maintenance areas. This information can be used in the development of remote handling procedures required during shutdown for maintenance. A methodology has been developed and is proposed in this paper to quantify the activated source term from the primary HX components as a result of the movement of the delayed neutron precursors in flowing primary fuel salt through the primary HXs in the MSBR. The goal of this research is to evaluate the gamma dose rates in the maintenance hatches above the primary HX using the activated HX source terms. The study showed that the gamma dose rates are approximately two orders of magnitudes higher when accounting for the neutron activation from the movement of delayed neutron precursors through the HXs than when flowing fuel is not considered. Thus, the movement of delayed neutron precursors must be taken into account for accurately predicting the neutron activation of primary loop components.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Morphometrics of cellular damage in mice testis receiving X-ray and high-energy particle irradiation

Murine tests were exposed to single, low doses of either X-ray, helium, or argon radiation. Animals were sacrificed seventy-two hours later. Testes were fixed for transmission electron microscopy (TEM) and sectioned at either 60 nm for TEM observation or at 2 micron for counting using routine light microscope methods. Counts of the total population of surviving spermatogonia, including all type A cells, intermediate, and type B cells, were taken from tubule cross sections identified as Stage 6 and Stage 1 according to spermatogonial configuration. The surviving fraction of spermatogonia as compared to control, S/S sub o, was calculated for each dose. For both ions and X-rays, there was a rapid decline in survival at dose levels of .10 to .15 Gy in Stage 6 tubules. This was followed by a more gradual decrease in population. At higher doses, 0.30 Gy for argon and 0.80 Gy for helium and X-rays, the cell survival rates declined rapidly. Pre-leptotene spermatocytes in Stage 1 tubules exhibited a different survival curve indicating the extreme radio-sensitivity of type B spermatogonia. Data verify that the seminiferous tubules are composed of a heterogeneous population of cells with different radio-sensitivities and that these differences are manifested even at very low doses.

Sapp, Walter J.↗

ECAR-7448 Rev 0 MARVEL Post-Shutdown Dose Analysis in the Upper Confinement

This report documents a bounding post-shutdown dose rates over time in the upper confinement area and above the top of the TREXc Pit Shield at the end of two years of operation of the MARVEL microreactor. The dose rates take into consideration the doses from the core fission products, the sodium-potassium coolant (NaK), the steel components, the Stirling engines, and the gallium eutectic (EGaInSn) secondary coolant. The MCNP model in this analysis is based on the 90% design of the MARVEL reactor from ECAR- 7447. Neutron fluence used as inputs to this analysis were calculated in ECAR-7447.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Comprehensive Analysis of Streaming and Shutdown Dose Rate Experiments at JET with ORNL Fusion Neutronics Workflows

Current experimental fusion systems and conceptual designs of fusion pilot plants (FPPs) are growing in complexity and size. Several radiation metrics are crucial to the safe operation of fusion machines, including neutron flux streaming through openings and the shutdown dose rate (SDDR). Most current designs of advanced experimental fusion systems—and the most probable candidates for FPPs—are based on the tokamak concept, which is prone to neutron streaming through the myriad openings needed for diagnostic and support systems. SDDR is caused by decay gamma rays from radionuclides that become activated by neutrons during the operation of a fusion system that use deuterium-deuterium (DD), tritium-tritium, or deuterium-tritium plasma. Because computational tools have become essential for determining these radiation metrics, they must be validated against reliable and applicable experimental data. Experiments at the Joint European Torus (JET) provide a unique source of experimental data for validating computational tools and nuclear data used to determine SDDR and neutron fluxes in streaming-dominated geometries. Here, this paper presents the comprehensive analysis of the high-performance DD JET SDDR, and streaming experiments performed using Oak Ridge National Laboratory (ORNL) fusion workflows. The computational results were compared with experimental results that consist of online SDDR measurements with ionization chambers and neutron fluence streaming measurements using thermoluminescent detectors. The ratio of calculated-to-experimental SDDR values ranges from 0.6 to 2.5, and the streaming results range from 0.5 to 8.0. Future work will include analyzing the JET 2021 DTE2 campaign alongside the integration of the Shift Monte Carlo transport code into all ORNL fusion neutronics workflows.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of 63 MeV proton irradiation on the performance of MWIR InGaAs/InAsSb nBn photodetectors

An investigation into the effects of 63 MeV proton irradiation on high-sensitivity mid-wave infrared InGaAs/InAsSb nBn devices is performed. Three different structures with various absorber region doping profiles are irradiated and characterized to assess their impact on performance degradation. Minority carrier lifetime is measured using time-resolved photoluminescence and lifetime damage factors are assessed. The majority carrier concentration is determined via capacitance–voltage measurements and dopant introduction rates are calculated. An analysis of dark current density is performed using these material parameters, revealing a reduction in mobility with proton fluence and the emergence of a proton-induced trap energy level. Quantum efficiency is calculated at each proton fluence, and quantum efficiency damage factors show that the graded doping structure exhibits the least reduction of quantum efficiency with dose, attributed to its effective mobility enhancement. Conclusively, detector sensitivity, assessed via shot-noise limited noise-equivalent irradiance, shows that the graded doping structure is the least susceptible to high energy proton irradiation-induced performance degradation.

Physics↗

Modeling Radionuclide Inventories in MSR Off-Gas Systems with Radiochemical Transport Analysis

Molten salt reactors (MSR) contain unique characteristics that may require enhancements to modeling tools to accurately predict phenomena. One characteristic that may be advantageous to leverage during normal operation is on-line processing of the circulating fuel salt, such as an off-gas system (OGS) to remove volatile fission products. Therefore, new modeling tools must be developed to integrate spatial resolution and chemistry effects into fuel depletion tools to be able to account for these non-core sources of radioactivity. Such types of radiochemical transport analysis tools were used to estimate the removal rates for 12 elements within a flow model of the Molten Salt Reactor Experiment (MSRE) by optimizing against legacy experimental data of the gas-borne (GB) percentages of 12 nuclides. The removal rates were used in a depletion model to calculate the FP inventory that enters the MSRE OGS. Calculations are in good agreement with the empirical GB percentages reported for the 12 nuclides, which validates the approach and verifies each tool’s treatment of the radiochemical flow effects. The OGS inventory is discussed in terms of the largest nuclide contributors to activity, dose consequence, decay heat, and elemental composition. Finally, insights from the study allow recommendations to be made for future code development activities.

Shahbazi, Shayan↗

Shielding analysis for a manned Mars rover powered by an SP-100 type reactor

Shield design is one of the most crucial tasks in the integration of a nuclear reactor power system to a manned Mars rover. A multilayered W and LiH shield is found to minimize the shield mass and satisfy the dose rate limit of 30 rem/y to the rover crew. The effect on dose rate of tungsten layers thicknesses and position within the lithium hydride shields is investigated. Due to the large cross section for the W (n,gamma) reaction, secondary gammas become a significant radiation source. The man-rated shield mass for the Mars rover vehicle is correlated to the reactor thermal power. The correlation fits to within 9 percent of the calculated shield mass and results in an uncertainty of below 4 percent in the overall rover mass. The shield mass varied from 8600 kg to 20580 kg for a reactor thermal power of 100 to 1000 kW(t), respectively.

Morley, Nicholas J.↗

Global Mapping of Underwater UV Irradiances and DNA-Weighted Exposures using TOMS and SeaWiFS Data Products

The global stratospheric ozone-layer depletion results In an increase in biologically harmful ultraviolet (UV) radiation reaching the surface and penetrating to ecologically significant depths in natural waters. Such an increase can be estimated on a global scale by combining satellite estimates of UV irradiance at the ocean surface from the Total Ozone Mapping Spectrometer (TOMS) satellite instrument with the SeaWIFS satellite ocean-color measurements in the visible spectral region. In this paper we propose a model of seawater optical properties in the UV spectral region based on the Case I water model in the visible range. The inputs to the model are standard monthly SeaWiFS products: chlorophyll concentration and the diffuse attenuation coefficient at 490nm. Penetration of solar UV radiation to different depths in open ocean waters is calculated using the RT (radiative transfer) quasi-single scattering approximation (QSSA). The accuracy of the QSSA approximation in the water is tested using more accurate codes. The sensitivity study of the underwater UV irradiance to atmospheric and oceanic optical properties have shown that the main environmental parameters controlling the absolute levels of the UVB (280-320nm) and DNA-weighted irradiance underwater are: solar-zenith angle, cloud transmittance, water optical properties, and total ozone. Weekly maps of underwater UV irradiance and DNA-weighted exposure are calculated using monthly-mean SeaWiFS chlorophyll and diffuse attenuation coefficient products, daily SeaWiFS cloud fraction data, and the TOMS-derived surface UV irradiance daily maps. The final products include global maps of weekly-average UVB irradiance and DNA-weighted daily exposures at 3m and 10m, and depths where the UVB irradiance and DNA-weighted dose rate at local noon are equal to 10% of their surface values.

Vasilkov, Alexander↗

Preliminary Criticality and Radiation Shielding Analysis for the Storage and Transfer of MARVEL Reactor Spent Nuclear Fuel

This report documents the results of preliminary nuclear criticality and radiation shielding assessments during transfer and dry storage of irradiated Microreactor Applications Research Validation and Evaluation (MARVEL) reactor fuel at Idaho National Laboratory (INL). The assessments focus on transfer casks and storage canisters that are currently in use at INL, which may be compatible with the irradiated MARVEL reactor fuel. The criticality assessments were performed using the radiation transport code MCNP6 with 37 MARVEL reactor fuel elements in various configurations and scenarios. All transfer and storage configurations under dry conditions were below the assumed criticality safety limit of 0.93. Some storage and transfer configurations under wet conditions exceeded the criticality safety limit. This suggests that the appropriate administrative and engineering controls, in addition to reducing the number of MARVEL reactor fuel elements per transfer cask or storage canister, can be expected to ensure criticality safety under all scenarios. The radiation shielding assessments were performed by generating conservative neutron and photon source terms using the ORIGEN module in the SCALE suite of codes. These source spectra were used to estimate the dose equivalent rates using the radiation transport code MCNP6, both on contact and 1 m away from the fuel and transfer casks. The maximum estimated dose equivalent rate of 37 unshielded MARVEL reactor fuel elements on contact is approximately 42000 R/hr. The maximum estimated dose equivalent rates on contact to the ATR transfer cask, HFEF-5 transfer cask, and high load charger were approximately 233 mR/hr, 171 mR/hr, and 201 mR/hr, respectively. This suggests that with the appropriate administrative and engineering controls, all three transfer casks analyzed can be expected to provide sufficient radiation shielding to workers during transfer of irradiated MARVEL reactor fuel. These calculations are performed to support the planning and strategy for the MARVEL project and will demonstrate the technical viability of the different configurations discussed and help identify where engineered or administrative controls may be necessary. A complete criticality safety analysis and radiation shielding analysis, including validation and contingency and accident analysis must be completed by licensed and authorized personnel before any transfer or storage of MARVEL reactor nuclear fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Application of transport techniques to the analysis of NERVA shadow shields

A radiation shield internal to the NERVA nuclear rocket reactor required to limit the neutron and photon radiation levels at critical components located external to the reactor was evaluated. Two significantly different shield mockups were analyzed: BATH, a composite mixture of boron carbide, aluminum and titanium hydride, and a borated steel-liquid hydrogen system. Based on the comparisons between experimental and calculated neutron and photon radiation levels, the following conclusions were noted: (1) The ability of two-dimensional discrete ordinates code to predict the radiation levels internal to and at the surface of the shield mockups was clearly demonstrated. (2) Internal to the BATH shield mockups, the one-dimensional technique predicted the axial variation of neutron fluxes and photon dose rates; however, the magnitude of the neutron fluxes was about a factor of 1.8 lower than the two-dimensional analysis and the photon dose rate was a factor of 1.3 lower.

Capo, M. A.↗

Full Mission Astronaut Radiation Exposure Assessments for Long Duration Lunar Surface Missions

Risk to astronauts due to ionizing radiation exposure is a primary concern for missions beyond Low Earth Orbit (LEO) and will drive mission architecture requirements, mission timelines, and operational practices. Both galactic cosmic ray (GCR) and solar particle event (SPE) environments pose a risk to astronauts for missions beyond LEO. The GCR environment, which is made up of protons and heavier ions covering a broad energy spectrum, is ever present but varies in intensity with the solar cycle, while SPEs are sporadic events, consisting primarily of protons moving outward through the solar system from the sun. The GCR environment is more penetrating and is more difficult to shield than SPE environments, but lacks the intensity to induce acute effects. Large SPEs are rare, but they could result in a lethal dose, if adequate shielding is not provided. For short missions, radiation risk is dominated by the possibility of a large SPE. Longer missions also require planning for large SPEs; adequate shielding must be provided and operational constraints must allow astronauts to move quickly to shielded locations. The dominant risk for longer missions, however, is GCR exposure, which accumulates over time and can lead to late effects such as cancer. SPE exposure, even low level SPE exposure received in heavily shielded locations, will increase this risk. In addition to GCR and SPE environments, the lunar neutron albedo resulting mainly from the interaction of GCRs with regolith will also contribute to astronaut risk. Full mission exposure assessments were performed for proposed long duration lunar surface mission scenarios. In order to accomplish these assessments, radiation shielding models were developed for a proposed lunar habitat and rover. End-to-End mission exposure assessments were performed by first calculating exposure rates for locations in the habitat, rover, and during extra-vehicular activities (EVA). Subsequently, total mission exposures were evaluated for proposed timelines. A number of computational tools and mathematical models, which have been incorporated into NASA's On-Line Tool for the Assessment of Radiation In Space (OLTARIS), were used for this study. These tools include GCR and SPE environment models, human body models, and the HZETRN space radiation transport code, which is used to calculate the transport of the charged particles and neutrons through shielding materials and human tissue. Mission exposure results, assessed in terms of effective dose, are presented for proposed timelines and recommendations are made for improved astronaut shielding and safer operational practice.

Adamczyk, Anne M.↗