Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTRIC POTENTIAL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Automating the Study of Microbial Adaptation Dynamics on and off the ISS

The International Space Station (ISS) not only serves as a unique environment for humans, but also the microorganisms that join alongside. Many microbes present on the spacecraft arrive via humans, and as they interact with different surfaces they begin to inhabit those locations. Much like how human health has shown to be impacted by these extreme environments, microbial viability and response to stress also changes. Experimental evolution (EE) can aid in studying how microbes’ growth and activity changes within the ISS environments by applying controlled stressors to microbial cultures and monitoring their response over generations. EE studies are commonly done manually in laboratories, but, with multiple environmental variables to measure and adjust, it becomes highly labor-intensive, prone to human error, and challenging to scale. A multipurpose automated EE system named the AADEC has been developed to address these problems. This system integrates multiple sensors into a single fluidic chamber using UV-C flux, temperature, and media composition as stressors. AADEC contains five sensors: oxidation-reduction potential, electrical conductivity, pH, dissolved oxygen, and optical density. On their own, each is able to provide certain information on growth rate or metabolism; together, they show in detail how stressors affect life. AADEC studies can be conducted on Earth and repeated aboard the ISS to see how behavior changes when exposed to space mission stressors such as microgravity and radiation. AADEC’s auxiliary systems include peristaltic pumps for media exchange, magnetic rods for agitation, and a Raspberry Pi microprocessor to monitor, store, and adjust stressor levels real-time. This allows researchers to gather information within rapid generations, data and accuracy which is challenging to achieve through manual studies. With further miniaturization and automation, such as a more robust single-piece fluidics card, AADEC has the potential to be developed as a spacecraft payload. Support: NASA Ames CIF Award

Automating↗

Electron Flow to a Satellite at High Positive Potential

The Tethered Satellite System (TSS) is designed to deploy a 1.6 m diameter spherical satellite a distance of 20 km above the space shuttle orbiter on an insulated conducting tether. Because of the passage of the conducting tether through the earth's magnetic field, an emf is generated producing a positive satellite potential of about 5000 V. Electron flow under the influence of this high positive potential is the focus of the present analysis. The ionospheric parameters at TSS orbit altitude are; thermal velocity of electrons, 1.9 x 10(exp 5) M/S, thermal velocity of the ions, 1.1 x 10(exp 3) m/s, velocity of the satellite 8 x 10(exp 3) m/s. The electrons, with a Debye length, lambda(D) = 0.49 cm, spiral about the earth's magnetic field lines (0.4 Gauss) with a radius of about 3 cm and the ions spiral with a radius of 5 m. Under these conditions, the electron thermal energy, kT is 0.17 eV. The TSS satellite radius, r(p) is 163 Debye lengths. There is an extensive literature on the interaction of satellites with the near-earth ionospheric plasma. The space charge limitation to the electron current collected by a sphere at positive electrical potential was calculated by Langmuir and Blodgett (1924). Parker and Murphy (1967) recognized the importance of the influence of the earth's magnetic field and used the guiding center approximation to calculate the electron current collected by a positive charged satellite. More recently Ma and Schunk (1989) have calculated the time dependent flow of electrons to a spherical satellite at positive potential utilizing numerical methods and Sheldon (1994) used similar methods to solve this problem for the steady state. In order to analyze some of the phenomena that occurred in the ionosphere during the TSS flights, it would be useful to have analytic expressions for these electron flows. The governing equations are very complex and an exact analytical solution is not likely. An approximate analytical solution is feasible however, and the results of one attempt are presented herein.

Sheldon, John W.↗

Density trace made with computer printout

Special drum for a computer-controlled printer improves density trace of scientific data. The drum provides uniformly shaped characters and evenly spaced variations of print density that precisely reflect data magnitude. This device plots temperature profiles, geographic contours, pressure gradients, electric potential gradients, and magnetic field configurations.

Wilson, M.↗

Studies in zirconium oxidation

Study provides insight into the oxidation mechanism of zirconium by combining electrical measurements with oxidation data. The measurement of electrical potential across growing scale on zirconium and the determination of conventional weight-change oxidation data were carried out at 550, 700, and 800 degrees C.

Draley, J. E.↗

Synchronous charge-constrained electroquasistatic generator

Electroquasistatic generator depends on electroquasistatic interactions to provide synchronous operation. The generator employs a moving insulating belt, with an ac electric potential source to establish positively and negatively charged regions on the belt. The field effect of the charges on the belt creates an ac output voltage.

Melcher, J. R.↗

Measurements of plasma parameters in a simulated thermionic converter

Cesium-filled thermionic energy converters are examined as candidate electrical energy sources in spacecraft requiring tens to hundreds of kilowatts of electric power. The high operating temperatures necessary for a large specific power and high efficiency inevitably impose stringent constraints on the converter fabrication to achieve the desired reliability of the power system. The converter physics for reducing operating temperatures and cesium plasma losses are studied to achieve high reliability without sacrificing the power performance of the converters. Various cesium parameters which affect the converter performance are: (1) electron temperatures, (2) plasma ion densities, and (3) electric potential profiles. These were investigated using a Langmuir probe in a simulated converter. The parameters were measured in different cesium discharge modes.

Shimada, K.↗

Probe measurements of a cesium plasma in a simulated thermionic energy converter

Cesium-filled thermionic energy converters are considered as electrical energy sources in future spacecraft requiring tens to hundreds of kilowatts of electric power. The high operating temperatures necessary for a large specific power and high efficiency impose stringent constraints on the converter fabrication. The converter physics for reducing operating temperatures and cesium plasma losses are being studied to achieve high reliability without sacrificing the power performance of the converters. Various cesium parameters which affect the converter performance are: (1) electron temperatures, (2) plasma ion densities, and (3) electric potential profiles. These were investigated using a Langmuir probe in a simulated converter. The parameters were measured in different cesium discharge modes.

Shimada, K.↗

A new dry biomedical electrode

Electronic circuitry contains new operational amplifier which incorporates monolithic super-gain transistors. Electrode does not provide voltage amplification; instead, it acts as current amplifier to make it possible to pick up electrical potentials from surface of highly resistant dry skin.

Luce, R. S.↗

Assistance to NASA in biomedical areas of the technology utilization program

The applications of aerospace technology to biomedical research are reported. The medical institutions participating in the Biomedical Applications Program are listed along with the institutions currently utilizing the services of the Southwest Research Institute Biomedical Applications Team. Significant accomplishments during this period include: ultra-low bandpass amplifier for gastro-intestinal electric potentials; non-encumbering EEG electrode assembly suitable for long term sleep research; accurate cardiac telemetry system for active subjects; warning system for the deaf; tracking cane for the blind; and an improved control mechanism to expand the self-sufficiency of quadriplegics.

Culclasure, D. F.↗

Experimental investigation of a throttlable 15 cm hollow cathode ion thruster

The use of dished high perveance grids on a 15 cm modified SERT 2 thruster is shown to facilitate throttled operation over a beam current range from 60 to 600 mA. Effects of increasing the radial component of the magnetic field in the main discharge chamber and decreasing the dimensions of the cathode discharge region are examined and found to degrade performance to the extent that primary electrons are forced in toward the center-line of the thruster. Studies of the baffle aperture region of two thrusters indicate that the electric potential gradient vector is perpendicular to the local magnetic field lines when the thruster is operating properly. The correlation between the shape of the ion beam current density and that of the ion density at the screen grid within the thruster is shown to be 94%. Additional experimental studies on maximum propellant utilization, plasma ion production cost, neutral density in the cathode discharge region, double ion production in hollow cathode thrusters and thermal flow meter performance are discussed.

Wilbur, P. J.↗

Diffusion of ring current particles by low-frequency long-wavelength electrostatic oscillations.

The diffusion of charged particles by randomly fluctuating low-frequency long-wavelength electrostatic oscillations in the magnetosphere is investigated as a possible mechanism for transporting ring current particles. The diffusion process is assumed to preserve the first adiabatic invariant. The magnetosphere is represented by a simple model with cylindrical geometry. In the model the ionospheres are assumed to be perfectly conducting and the ring current is assumed to have a Maxwellian distribution of velocities. The electrostatic oscillations are treated as natural modes of the magnetospheric cavity which are driven by variations in the electric potential on the magnetopause. It is concluded that diffusion of ring current protons by this process is not important in the magnetosphere.

Maggs, J. E.↗