Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTROMAGNETIC ABSORPTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

200 records · Page 12

Dynamic Self-Locking of an OEO Containing a VCSEL

A method of dynamic self-locking has been demonstrated to be effective as a means of stabilizing the wavelength of light emitted by a vertical-cavity surface-emitting laser (VCSEL) that is an active element in the frequency-control loop of an optoelectronic oscillator (OEO) designed to implement an atomic clock based on an electromagnetically- induced-transparency (EIT) resonance. This scheme can be considered an alternative to the one described in Optical Injection Locking of a VCSEL in an OEO (NPO-43454), NASA Tech Briefs, Vol. 33, No. 7 (July 2009), page 33. Both schemes are expected to enable the development of small, low-power, high-stability atomic clocks that would be suitable for use in applications involving precise navigation and/or communication. To recapitulate from the cited prior article: In one essential aspect of operation of an OEO of the type described above, a microwave modulation signal is coupled into the VCSEL. Heretofore, it has been well known that the wavelength of light emitted by a VCSEL depends on its temperature and drive current, necessitating thorough stabilization of these operational parameters. Recently, it was discovered that the wavelength also depends on the microwave power coupled into the VCSEL. This concludes the background information. From the perspective that led to the conception of the optical injection-locking scheme described in the cited prior article, the variation of the VCSEL wavelength with the microwave power circulating in the frequency-control loop is regarded as a disadvantage and optical injection locking is a solution of the problem of stabilizing the wavelength in the presence of uncontrolled fluctuations in the microwave power. The present scheme for dynamic self-locking emerges from a different perspective, in which the dependence of VCSEL wavelength on microwave power is regarded as an advantageous phenomenon that can be exploited as a means of controlling the wavelength. The figure schematically depicts an atomic-clock OEO of the type in question, wherein (1) the light from the VCSEL is used to excite an EIT resonance in selected atoms in a gas cell (e.g., 87Rb atoms in a low-pressure mixture of Ar and Ne) and (2) the power supplied to the VCSEL is modulated by a microwave signal that includes components at beat frequencies among the VCSEL wavelength and modulation sidebands. As the VCSEL wavelength changes, it moves closer to or farther from a nearby absorption spectral line, and the optical power transmitted through the cell (and thus the loop gain) changes accordingly. A change in the loop gain causes a change in the microwave power and, thus, in the VCSEL wavelength. It is possible to choose a set of design and operational parameters (most importantly, the electronic part of the loop gain) such that the OEO stabilizes itself in the sense that an increase in circulating microwave power causes the VCSEL wavelength to change in a direction that results in an increase in optical absorption and thus a decrease in circulating microwave power. Typically, such an appropriate choice of operational parameters involves setting the nominal VCSEL wavelength to a point on the shorter-wavelength wing of an absorption spectral line.

Strekalov, Dmitry↗

Volcanic CO2 Abundance of Kilauea Plume Retrieved by Meand of AVIRIS Data

Absorbing the electromagnetic radiation in several regions of the solar spectrum, CO2 plays an important role in the Earth radiation budget since it produces the greenhouse effect. Many natural processes in the Earth s system add and remove carbon dioxide. Overall, measurements of atmospheric carbon dioxide at different sites around the world show an increased carbon dioxide concentration in the atmosphere. At Mauna Loa Observatory (Hawaii) the measured carbon dioxide increased from 315 to 365 ppm, in the period 1958 2000 [Keeling et al., 2001]. While at the large scale, the relationship between CO2 increase and global warming is established [IPCC, 1996], at the local scale, many studies are still needed to understand regional and local sources of carbon dioxide, such as volcanoes. The volcanic areas are particularly rich in carbon dioxide; this is due to magma degassing in the summit craters region of active volcanoes, and to the presence of fractures and active faults [Giammanco et al., 1998]. Several studies estimate a global flux of volcanic CO2 (34+/-24)10(exp 6) tons/day from effusive volcanic emissions, such as the tropospheric volcanic plume (Table 1) [McClelland et al., 1989]. Plumes are a turbulent mixture of gases, solid particles and liquid droplets, emitted continuously at high temperature from summit craters, fumarolic fields or during eruptive episodes. Inside the plume, water vapour represents 70 90% of the volcanic gases. The main gaseous components are CO2, SO2, HCl, H2, H2S, HF, CO, N2 and CH4. Other plume components are volcanic ash, aqueous and acid droplets and solid sulphur-derived particles [Sparks et al., 1997]. Volcanic gases and aerosols are evidences of volcanic activity [Spinetti et al., 2003] and they have important climatic and environmental effects [Fiocco et al., 1994]. For example, Etna volcano is one of the world s major volcanic gas sources [Allard et al., 1991]. New studies on volcanic gaseous emissions have pointed out that a variation of the gas ratio CO2/SO2 is related to eruptive episodes [Caltabiano et al., 1994]. However, measurements and monitoring of volcanic carbon dioxide are difficult and often hazardous, due to the high background presence of atmospheric CO2 and the inaccessibility of volcanic sites. Hyperspectral remote sensing is a suitable technique to overcome the difficulties of ground measurement. It permits a rapid, comprehensive view of volcanic plumes and their evolution over time, detection of all gases with absorption molecular lines within the sensor s multispectral range and, in general, measurement of all the volatile components evolving from craters. The molecular and particle plume components scatter and absorb incident solar radiation. The integral of the radiation difference composes the signal measured by the remote spectrometer. The inversion technique consists of retrieving the plume component concentrations, hence decomposing the signal into the different contributions. The accuracy of remote sensing techniques depends primarily on the sensor capability and sensitivity.

Spinetti, C.↗