Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTROMAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Improvements to the characterization of Agfa x-ray film for use on opacity spectroscopy diagnostics

The National Ignition Facility uses a soft x-ray opacity spectrometer for x-ray spectral imaging in high-energy-density experiments. The increased demand for a better spectral resolution prompted the investigation into the Agfa D4 film. Characterization is already under way for the film. A Manson x-ray source using six different anodes was used to expose film to the linear optical density (OD) region. This is a continuation of the previous work, and the updated analysis process is communicated here. The identified uncertainties have been reduced with the updated steps that improve the results of the characterization process. In conclusion, when the Stanford Synchrotron Radiation Lightsource Beamline 16-2 was operational, the film was characterized at that source. Its beam offered a higher fluency with a lower exposure time needed to reach saturation. Results for both sources are compared in this paper.

47 OTHER INSTRUMENTATION↗

IMPLICATIONS OF A HIGH ANGULAR RESOLUTION IMAGE OF THE SUNYAEV-ZEL'DOVICH EFFECT IN RXJ1347-1145

The most X-ray luminous cluster known, RXJ1347-1145 (z = 0.45), has been the object of extensive study across the electromagnetic spectrum. We have imaged the Sunyaev-Zel'dovich effect (SZE) at 90 GHz ({lambda} = 3.3 mm) in RXJ1347-1145 at 10'' resolution with the 64 pixel MUSTANG bolometer array on the Green Bank Telescope, confirming a previously reported strong, localized enhancement of the SZE 20'' to the southeast of the center of X-ray emission. This enhancement of the SZE has been interpreted as shock-heated (>20 keV) gas caused by an ongoing major (low mass ratio) merger event. Our data support this interpretation. We also detect a pronounced asymmetry in the projected cluster pressure profile, with the pressure just east of the cluster core {approx}1.6x higher than just to the west. This is the highest resolution image of the SZE made to date.

79 ASTRONOMY AND ASTROPHYSICS↗

A SOLAR SPECTROSCOPIC ABSOLUTE ABUNDANCE OF ARGON FROM RESIK

Observations of He-like and H-like Ar (Ar XVII and Ar XVIII) lines at 3.949 A and 3.733 A, respectively, with the RESIK X-ray spectrometer on the CORONAS-F spacecraft, together with temperatures and emission measures from the two channels of GOES, have been analyzed to obtain the abundance of Ar in flare plasmas in the solar corona. The line fluxes per unit emission measure show a temperature dependence like that predicted from theory and lead to spectroscopically determined values for the absolute Ar abundance, A(Ar) = 6.44 {+-} 0.07 (Ar XVII) and 6.49 {+-} 0.16 (Ar XVIII), which are in agreement to within uncertainties. The weighted mean is 6.45 {+-} 0.06, which is between two recent compilations of the solar Ar abundance and suggests that the photospheric and coronal abundances of Ar are very similar.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FLARES AND THEIR UNDERLYING MAGNETIC COMPLEXITY

SphinX (Solar PHotometer IN X-rays), a full-disk-integrated spectrometer, observed 137 flare-like/transient events with active region (AR) 11024 being the only AR on disk. The Hinode X-Ray Telescope (XRT) and Solar Optical Telescope observe 67 of these events and identified their location from 12:00 UT on July 3 through 24:00 UT 2009 July 7. We find that the predominant mechanisms for flares observed by XRT are (1) flux cancellation and (2) the shearing of underlying magnetic elements. Point- and cusp-like flare morphologies seen by XRT all occur in a magnetic environment where one polarity is impeded by the opposite polarity and vice versa, forcing the flux cancellation process. The shearing is either caused by flux emergence at the center of the AR and separation of polarities along a neutral line or by individual magnetic elements having a rotational motion. Both mechanisms are observed to contribute to single- and multiple-loop flares. We observe that most loop flares occur along a large portion of a polarity inversion line. Point- and cusp-like flares become more infrequent as the AR becomes organized with separation of the positive and negative polarities. SphinX, which allows us to identify when these flares occur, provides us with a statistically significant temperature and emission scaling law for A and B class flares: EM = 6.1 x 10{sup 33} T{sup 1.9{+-}0.1}.

79 ASTRONOMY AND ASTROPHYSICS↗

EFFECTS OF REFRACTION ON ANGLES AND TIMES OF ARRIVAL OF SOLAR RADIO BURSTS

Solar type III and type II radio bursts suffer severe bending and group delay due to refraction while escaping from the source where the refractive index {mu} can be as low as {approx}0 to the observer where {mu} {approx} 1. These propagation effects can manifest themselves as errors in the observed directions and times of arrival at the telescope. We describe a ray-tracing technique that can be used to estimate these errors. By applying this technique to the spherically symmetric density model derived using the data from the WIND/Waves experiment, we show that (1) the fundamental and harmonic emissions escape the solar atmosphere in narrow cones (at 625 kHz the widths of these escape cones are {approx}1.{sup 0}1 and {approx}8{sup 0}, respectively), (2) the errors in the angles as well as the times of arrival increase monotonically with the angle of arrival (at 625 kHz these errors are 0.{sup 0}26 and {approx}17.2 s for the fundamental and {approx}0.{sup 0}52 and {approx}7.6 s for the harmonic at the maximum possible angles of arrival of {approx}0.{sup 0}55 and {approx}4{sup 0}, respectively), and (3) the lower the frequencies are, the higher the errors in both the angles and times of arrival are. This implies that at 625 kHz the measured arrival angles and arrival times of the fundamental and harmonic are off by {approx}50% and {approx}13%, and {approx}3.4% and {approx}1.5%, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE EFFELSBERG-BONN H I SURVEY: DATA REDUCTION

Starting in winter 2008/2009 an L-band seven-feed-array receiver is used for a 21 cm line survey performed with the 100 m telescope, the Effelsberg-Bonn H I survey (EBHIS). The EBHIS will cover the whole northern hemisphere for decl. > - 5{sup 0} comprising both the galactic and extragalactic sky out to a distance of about 230 Mpc. Using state-of-the-art FPGA-based digital fast Fourier transform spectrometers, superior in dynamic range and temporal resolution to conventional correlators, allows us to apply sophisticated radio frequency interference (RFI) mitigation schemes. In this paper, the EBHIS data reduction package and first results are presented. The reduction software consists of RFI detection schemes, flux and gain-curve calibration, stray-radiation removal, baseline fitting, and finally the gridding to produce data cubes. The whole software chain is successfully tested using multi-feed data toward many smaller test fields (1-100 deg{sup 2}) and recently applied for the first time to data of two large sky areas, each covering about 2000 deg{sup 2}. The first large area is toward the northern galactic pole and the second one toward the northern tip of the Magellanic Leading Arm. Here, we demonstrate the data quality of EBHIS Milky Way data and give a first impression on the first data release in 2011.

79 ASTRONOMY AND ASTROPHYSICS↗

GLOBAL X-RAY PROPERTIES OF THE O AND B STARS IN CARINA

The key empirical property of the X-ray emission from O stars is a strong correlation between the bolometric and X-ray luminosities. In the framework of the Chandra Carina Complex Project, 129 O and B stars have been detected as X-ray sources; 78 of those, all with spectral type earlier than B3, have enough counts for at least a rough X-ray spectral characterization. This leads to an estimate of the L{sub X}-L{sub BOL} ratio for an exceptional number of 60 O stars belonging to the same region and triples the number of Carina massive stars studied spectroscopically in X-rays. The derived log(L{sub X}/L{sub BOL}) is -7.26 for single objects, with a dispersion of only 0.21 dex. Using the properties of hot massive stars listed in the literature, we compare the X-ray luminosities of different types of objects. In the case of O stars, the L{sub X}-L{sub BOL} ratios are similar for bright and faint objects, as well as for stars of different luminosity classes or spectral types. Binaries appear only slightly harder and slightly more luminous in X-rays than single objects; the differences are not formally significant (at the 1% level), except for the L{sub X}-L{sub BOL} ratio in the medium (1.0-2.5 keV) energy band. Weak-wind objects have similar X-ray luminosities but they display slightly softer spectra compared with 'normal' O stars with the same bolometric luminosity. Discarding three overluminous objects, we find a very shallow trend of harder emission in brighter objects. The properties of the few B stars bright enough to yield some spectral information appear to be different overall (constant X-ray luminosities, harder spectra), hinting that another mechanism for producing X-rays, besides wind shocks, might be at work. However, it must be stressed that the earliest and X-ray brightest among these few detected objects are similar to the latest O stars, suggesting a possibly smooth transition between the two processes.

79 ASTRONOMY AND ASTROPHYSICS↗

Relic neutralinos and the two dark matter candidate events of the CDMS II experiment

The CDMS Collaboration has presented its results for the final exposure of the CDMS II experiment and reports that two candidate events for dark matter would survive after application of the various discrimination and subtraction procedures inherent in their analysis. We show that a population of relic neutralinos, which was already proved to fit the DAMA/LIBRA data on the annual-modulation effect, could naturally also explain the two candidate CDMS II events, if these are actually due to a dark matter signal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Ta-based Superconducting Tunnel Junction X-ray Detectors for Fluorescence XAS

We are developing superconducting tunnel junction (STJ) soft X-ray detectors for chemical analysis of dilute samples by fluorescence-detected X-ray absorption spectroscopy (XAS). Our 36-pixel Nb-based STJ spectrometer covers a solid angle {Omega}/4{pi}{approx_equal}10{sup -3}, offers an energy resolution of {approx}10-20 eV FWHM for energies up to {approx}1 keV, and can be operated at total count rates of {approx}10{sup 6} counts/s. For increased quantum efficiency and cleaner response function, we have now started the development of Ta-based STJ detector arrays. Initial devices modeled after our Nb-based STJs have an energy resolution below 10 eV FWHM for X-ray energies below 1 keV, and pulse rise time discrimination can be used to improve their response function for energies up to several keV. We discuss the performance of the Ta-STJs and outline steps towards the next-generation of large STJ detector arrays with higher sensitivity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scintillating crystals for the Neutral Particle Spectrometer in Hall C at JLab

This report discusses the quality and performance of currently available PbWO crystals of relevance to high-resolution electromagnetic calorimetry, e.g. detectors for the Neutral Particle Spectrometer at Jefferson Lab or those planned for the Electron–Ion Collider. Since the construction of the Compact Muon Solenoid (CMS) at the Large Hadron Collider (LHC) and early PANDA (The antiProton ANnihilations at DArmstadt) electromagnetic calorimeter (ECAL) the worldwide availability of high quality PbWO 4 production has changed dramatically. We report on our studies of crystal samples from SICCAS/China and CRYTUR/Czech Republic that were produced between 2014 and 2019.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The dedicated QEXAFS facility at the SLS: Performance and Scientific Opportunities

The SuperXAS beamline at the Swiss Light Source (SLS) features a permanently installed monochromator for quick scanning EXAFS (QEXAFS) spectroscopy in series with a conventional double crystal monochromator (DCM). All installed optical components like collimating and focussing mirrors can be used by both devices. The remote exchange of the monochromators is possible in less than five minutes while maintaining the beam geometry on the sample. The QEXAFS system allows fast absorption scans down to the millisecond range for the investigation of time dependent processes. Using a Si(111) channel cut crystal the energy range from 5-16 keV can be covered, with a Si(311) cut the range 9.5-30 keV. Usually a quick scanning interval of 0.1 deg. - 2 deg. in Bragg angle is selected, thus covering XANES, full EXAFS or multiple edge scans of e.g. all L-edges of a heavy element. Up to about 80 spectra per second can be collected, corresponding to a time resolution of 12.5 ms. The high intensity of the beamline even facilitates fluorescence measurements on dilute samples.

43 PARTICLE ACCELERATORS↗

Radiation Hardened Beam Instrumentations for Multi-mega-watt Beam Facilities

A beam instrumentation is an essential element for the successful operate particle accelerators in which various diagnostics and beam control systems are integrated into beam optics. However, the performance of beam instrumentation is often subject to constraints such as prompt radiation dose, integrated radiation dose, operation (ambient) temperature and humidity, available space, and strength of embedded electromagnetic fields at the monitoring point. These constraints will limit the dynamic range of operational beam parameters, like the maximum achievable beam power. A seamless R\&D effort to develop the radiation hardened beam instrumentation should be made for future multi-MW beam facilities. In this paper, we describes about a radiation hardened beam instrumentation based on the operational experience of the NuMI beam line.

43 PARTICLE ACCELERATORS↗

A method for eliminating Faraday rotation in cryostat windows in longitudinal magneto-optical Kerr effect measurements

A solution to the problem of disturbing effect of the background Faraday rotation in the cryostat windows on longitudinal magneto-optical Kerr effect (LMOKE) measured under vacuum conditions and/or at low temperatures is proposed. The method for eliminating the influence of Faraday rotation in cryostat windows is based on special arrangement of additional mirrors placed on sample holder. In this arrangement, the orientation of the cryostat window is perpendicular to the light beam direction and parallel to an external magnetic field generated by the H-frame electromagnet. The operation of the LMOKE magnetometer with the special sample holder based on polarization modulation technique with a photo-elastic modulator is theoretically analyzed with the use of Jones matrices, and formulas for evaluating of the actual Kerr rotation and ellipticity of the sample are derived. The feasibility of the method and good performance of the magnetometer is experimentally demonstrated for the LMOKE effect measured in Fe/Au multilayer structures. The influence of imperfect alignment of the magnetometer setup on the Kerr angles, as derived theoretically through the analytic model and verified experimentally, is examined and discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Instrumentation and Experimental Developments for the Beamlines at the Synchrotron SOLEIL

This paper presents an overview of the instrumentation and experiments developed for the beamlines at Synchrotron SOLEIL in France. Currently fourteen beamlines are opened to users out of the twenty six scheduled. About half of the beamlines cover the soft x-rays region using spectroscopy and imagery techniques. The second half covers the hard x-rays field studying diffraction of matter. Some sample environments carried out for beamlines, for biology, chemistry and surface sciences are described. For the soft x-rays beamlines, carbon contamination of optics is a crucial issue. Different experiments are currently under study in order to reduce or even avoid this effect. Other studies relate to the improvement of metrological methods for beamline optics, to the reduction of vibrational effects for the microbeams and development of computer control for diffractometers. The various types of instruments and experiments will be presented both with an overview of the status of the beamlines in operation and under construction.

43 PARTICLE ACCELERATORS↗

Electron cyclotron resonance heating by magnetic filter field in a negative hydrogen ion source

The influence of magnetic filter field on plasma properties in the heating region has been investigated in a planar-type inductively coupled radio-frequency (RF) H{sup −} ion source. Besides filtering high energy electrons near the extraction region, the magnetic filter field is clearly observed to increase the electron temperature in the heating region at low pressure discharge. With increasing the operating pressure, enhancement of electron temperature in the heating region is reduced. The possibility of electron cyclotron resonance (ECR) heating in the heating region due to stray magnetic field generated by a filter magnet located at the extraction region is examined. It is found that ECR heating by RF wave field in the discharge region, where the strength of an axial magnetic field is approximately ∼4.8 G, can effectively heat low energy electrons. Depletion of low energy electrons in the electron energy distribution function measured at the heating region supports the occurrence of ECR heating. The present study suggests that addition of axial magnetic field as small as several G by an external electromagnet or permanent magnets can greatly increase the generation of highly ro-vibrationally excited hydrogen molecules in the heating region, thus improving the performance of H{sup −} ion generation in volume-produced negative hydrogen ion sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Versatile Multilayer Polarimeter for the Soft X-Ray Region

As modern undulators can generate light with arbitrary polarization states, experiments exploiting this feature in the range of soft x-rays have become increasingly widespread. For the success of these experiments characterising the polarization at the sample position is vital. Therefore a versatile, multi-purpose, UHV compatible, multilayer polarimeter has been designed and developed for measuring the Stokes vector of a soft x-ray beam. This high-precision, ultra high vacuum compatible instrument is supported by a Hexapod to simplify its alignment. Furthermore, the instrument has its own independent control system and has been designed for portability so that it can be moved with relative ease between different synchrotron facilities. The polarization analysis requires the rotation of a phase retarder and a polarization analyser, both about a common axis of the photon beam. The polarimeter employs reflection / transmission multilayers as phase retarders / analysers. Several sets of multilayers are installed inside the UHV chamber so that they may be exchanged in-situ without breaking the vacuum. The polarimeter doubles-up as a reflectometer / ellipsometer that enable determination of the polarization properties of optical elements including multilayers with very small surface roughness and several hundred bi-layers. The design details of the polarimeter and the results of first experiments to characterise the polarization of a beamline will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

VERY HIGH ENERGY gamma-RAY AFTERGLOW EMISSION OF NEARBY GAMMA-RAY BURSTS

The synchrotron self-Compton (SSC) emission from gamma-ray burst (GRB) forward shock can extend to the very high energy (VHE; E{sub {gamma}} > 100 GeV) range. Such high energy photons are rare and are attenuated by the cosmic infrared background before reaching us. In this work, we discuss the prospect to detect these VHE photons using the current ground-based Cherenkov detectors. Our calculated results are consistent with the upper limits obtained with several Cherenkov detectors for GRB 030329, GRB 050509B, and GRB 060505 during the afterglow phase. For five bursts in our nearby GRB sample (except for GRB 030329), current ground-based Cherenkov detectors would not be expected to detect the modeled VHE signal. Only for those very bright and nearby bursts like GRB 030329, detection of VHE photons is possible under favorable observing conditions and a delayed observation time of {approx}<10 hr.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CHIANTI-AN ATOMIC DATABASE FOR EMISSION LINES. XI. EXTREME-ULTRAVIOLET EMISSION LINES OF Fe VII, Fe VIII, AND Fe IX OBSERVED BY HINODE/EIS

A detailed study of emission lines from Fe VII, Fe VIII, and Fe IX observed by the EUV Imaging Spectrometer on board the Hinode satellite is presented. Spectra in the ranges 170-212 A and 246-292 A show strongly enhanced lines from the upper solar transition region (temperatures 5.4 <= log T <= 5.9) allowing a number of new line identifications to be made. Comparisons of Fe VII lines with predictions from a new atomic model reveal new plasma diagnostics, however there are a number of disagreements between theory and observation for emission line ratios insensitive to density and temperature, suggesting improved atomic data are required. Line ratios for Fe VIII also show discrepancies with theory, with the strong lambda185.21 and lambda186.60 lines underestimated by 60%-80% compared to lines between 192 and 198 A. A newly identified multiplet between 253.9 and 255.8 A offers excellent temperature diagnostic opportunities relative to the lines between 185 and 198 A, however the atomic model underestimates the strength of these lines by factors of 3-6. Two new line identifications are made for Fe IX at wavelengths 176.959 A and 177.594 A, while seven other lines between 186 and 200 A are suggested to be due to Fe IX but for which transition identifications cannot be made. The new atomic data for Fe VII and Fe IX are demonstrated to significantly modify models for the response function of the Transition Region And Coronal Explorer 195 A imaging channel, affecting temperature determinations from this channel. The data will also affect the response functions for other solar EUV imaging instruments such as SOHO/EIT, STEREO/EUVI, and the upcoming AIA instrument on the Solar Dynamics Observatory.

79 ASTRONOMY AND ASTROPHYSICS↗