At least 217 records · Page 12

Charges on strange quark nuggets in space

Since Witten's seminal 1984 paper on the subject, searches for evidence of strange quark nuggets (SQNs) have proven unsuccessful. In the absence of experimental evidence ruling out SQNs, the validity of theories introducing mechanisms that increase their stability should continue to be tested. To stimulate electromagnetic SQN searches, particularly space searches, we estimate the net charge that would develop on a SQN in space exposed to various radiation baths (and showers) capable of liberating the SQN's less strongly bound electrons, taking into account recombination with ambient electrons. We consider, in particular, the cosmic microwave background, radiation from the sun, and diffuse galactic and extragalactic ultraviolet backgrounds. The largest charge, for the settings considered, develops on a solar system SQN exposed to a solar X-ray flare. A possible dramatic signal of SQNs in explosive astrophysical events is noted.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Testing local Lorentz and position invariance and variation of fundamental constants by searching the derivative of the comparison frequency between a cryogenic sapphire oscillator and hydrogen maser

The cryogenic sapphire oscillator at the Paris Observatory has been continuously compared to various hydrogen masers since 2001. The early data sets were used to test local Lorentz invariance in the Robertson-Mansouri-Sexl (RMS) framework by searching for sidereal modulations with respect to the cosmic microwave background, and represent the best Kennedy-Thorndike experiment to date. In this work, we present continuous operation over a period of greater than six years from September 2002 to December 2008 and present a more precise way to analyze the data by searching the time derivative of the comparison frequency. Because of the long-term operation we are able to search both sidereal and annual modulations. The results give P{sub KT}={beta}{sub RMS}-{alpha}{sub RMS}-1=-1.7(4.0)x10{sup -8} for the sidereal and -23(10)x10{sup -8} for the annual term, with a weighted mean of -4.8(3.7)x10{sup -8}, a factor of 8 better than previous. Also, we analyze the data with respect to a change in gravitational potential for both diurnal and annual variations. The result gives {beta}{sub H-Maser}-{beta}{sub CSO}=-2.7(1.4)x10{sup -4} for the annual and -6.9(4.0)x10{sup -4} for the diurnal terms, with a weighted mean of -3.2(1.3)x10{sup -4}. This result is 2 orders of magnitude better than other tests that use electromagnetic resonators. With respect to fundamental constants a limit can be provided on the variation with ambient gravitational potential and boost of a combination of the fine structure constant ({alpha}), the normalized quark mass (m{sub q}), and the electron to proton mass ratio (m{sub e}/m{sub p}), setting the first limit on boost dependence of order 10{sup -10}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Reference Governor for Plasma-Shape Control in Tokamaks

Tokamaks are torus-shaped devices where a high-temperature, ionized gas (i.e. a plasma) is confined by means of helical magnetic fields. The ultimate goal of tokamaks is producing net electrical energy by means of nuclear-fusion reactions within the plasma. The shape of the plasma inside the tokamak is closely related with its confinement characteristics and, therefore, with the produced fusion power. In order to achieve and maintain plasma shapes that maximize the fusion yield, feedback controllers have been successfully developed during the years. However, machine-protection and plasma-stability requirements impose hard constraints on the plasma-shape targets that can be safely achieved by a feedback controller. In this work, a reference governor is proposed to provide, in real time, plasma-shape targets that fulfill the aforementioned safety requirements. The reference governor calculates such plasma-shape targets in response to changes in the state of the closed-loop system, as well as disturbances in the plasma energy and current. Here, the reference-governor design is based on a dynamical model of the plasma electromagnetic response. Simulation tests of the reference governor have been carried out for different plasma scenarios in the DIII-D tokamak to emulate realistic cases where safety may be compromised.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MagicPlate-512: A 2D silicon detector array for quality assurance of stereotactic motion adaptive radiotherapy

Purpose: Spatial and temporal resolutions are two of the most important features for quality assurance instrumentation of motion adaptive radiotherapy modalities. The goal of this work is to characterize the performance of the 2D high spatial resolution monolithic silicon diode array named “MagicPlate-512” for quality assurance of stereotactic body radiation therapy (SBRT) and stereotactic radiosurgery (SRS) combined with a dynamic multileaf collimator (MLC) tracking technique for motion compensation. Methods: MagicPlate-512 is used in combination with the movable platform HexaMotion and a research version of radiofrequency tracking system Calypso driving MLC tracking software. The authors reconstruct 2D dose distributions of small field square beams in three modalities: in static conditions, mimicking the temporal movement pattern of a lung tumor and tracking the moving target while the MLC compensates almost instantaneously for the tumor displacement. Use of Calypso in combination with MagicPlate-512 requires a proper radiofrequency interference shielding. Impact of the shielding on dosimetry has been simulated by GEANT4 and verified experimentally. Temporal and spatial resolutions of the dosimetry system allow also for accurate verification of segments of complex stereotactic radiotherapy plans with identification of the instant and location where a certain dose is delivered. This feature allows for retrospective temporal reconstruction of the delivery process and easy identification of error in the tracking or the multileaf collimator driving systems. A sliding MLC wedge combined with the lung motion pattern has been measured. The ability of the MagicPlate-512 (MP512) in 2D dose mapping in all three modes of operation was benchmarked by EBT3 film. Results: Full width at half maximum and penumbra of the moving and stationary dose profiles measured by EBT3 film and MagicPlate-512 confirm that motion has a significant impact on the dose distribution. Motion, no motion, and motion with MLC tracking profiles agreed within 1 and 0.4 mm, respectively, for all field sizes tested. Use of electromagnetic tracking system generates a fluctuation of the detector baseline up to 10% of the full scale signal requiring a proper shielding strategy. MagicPlate-512 is also able to reconstruct the dose variation pulse-by-pulse in each pixel of the detector. An analysis of the dose transients with motion and motion with tracking shows that the tracking feedback algorithm used for this experiment can compensate effectively only the effect of the slower transient components. The fast changing components of the organ motion can contribute only to discrepancy of the order of 15% in penumbral region while the slower components can change the dose profile up to 75% of the expected dose. Conclusions: MagicPlate-512 is shown to be, potentially, a valid alternative to film or 2D ionizing chambers for quality assurance dosimetry in SRS or SBRT. Its high spatial and temporal resolutions allow for accurate reconstruction of the profile in any conditions with motion and with tracking of the motion. It shows excellent performance to reconstruct the dose deposition in real time or retrospectively as a function of time for detailed analysis of the effect of motion in a specific pixel or area of interest.

60 APPLIED LIFE SCIENCES↗

Hybrid Quantum Vision Transformers for Event Classification in High Energy Physics

Models based on vision transformer architectures are considered state-of-the-art when it comes to image classification tasks. However, they require extensive computational resources both for training and deployment. The problem is exacerbated as the amount and complexity of the data increases. Quantum-based vision transformer models could potentially alleviate this issue by reducing the training and operating time while maintaining the same predictive power. Although current quantum computers are not yet able to perform high-dimensional tasks, they do offer one of the most efficient solutions for the future. In this work, we construct several variations of a quantum hybrid vision transformer for a classification problem in high-energy physics (distinguishing photons and electrons in the electromagnetic calorimeter). We test them against classical vision transformer architectures. Our findings indicate that the hybrid models can achieve comparable performance to their classical analogs with a similar number of parameters.

Unlu, Eyup B. (ORCID:0000000266836463)↗

Simulation of space radiation effects on polyimide film materials for high temperature applications

Space environment effects on candidate materials for the solar sail film are determined. Polymers, including metallized polyimides that might be suitable solar radiation receivers, were exposed to combined proton and solar electromagnetic radiation. Each test sample was weighted, to simulate the tension on the polymer when it is stretched into near-planar shape while receiving solar radiation. Exposure rates up to 16 times that expected in Earth orbit were employed, to simulate near-sun solar sailing conditions. Sample appearance, elongation, and shrinkage were monitored, noted, and documented in situ. Thermosetting polyimides showed less degradation or visual change in appearance than thermoplastics.

Fogdall, L. B.↗

A review of Magnetic Suspension and Balance Systems

This paper traces the development of Magnetic Suspension and Balance Systems (MSBSs) for use in wind tunnels. The expression MSBS implies a system that can both suspend a model and also measure the forces and moments acting on the model. This avoids the need for any mechanical support of the model. An MSBS uses electromagnets located outside the test section walls to create magnetic fields inside the test section. Measurement of the electrical current flowing in each of the electromagnets can be used to determine the forces and moments acting on the suspended model. An MSBS is capable of supporting a model with an internal magnetized core subject to gravity, aerodynamic, and inertial loads. The model must have a core made of either a permanent magnet, magnetized soft iron, or a solenoid. The position of the suspended body is inherently unstable. A closed-loop control system which includes a position sensing system has to control the position of the body by controlling the applied magnetic fields. This paper includes a discussion of all the known MSBSs and the outlook for larger systems.

Boyden, Richmond P.↗

The Space-Time CE/SE Method for Solving Maxwell's Equations in Time-Domain

An innovative finite-volume-type numerical method named as the space-time conservation element and solution element (CE/SE) method is applied to solve time-dependent Maxwell's equations in this paper. Test problems of electromagnetics scattering and antenna radiation are solved for validations. Numerical results are presented and compared with the analytical solutions, showing very good agreements.

Wang, X. Y.↗

Charges on Strange Quark Nuggets in Space

Since Witten's seminal 1984 paper on the subject, searches for evidence of strange quark nuggets (SQNs) have proven unsuccessful. In the absence of experimental evidence ruling out SQNs, the validity of theories introducing mechanisms that increase their stability should continue to be tested. To stimulate electromagnetic SQN searches, particularly space searches, we estimate the net charge that would develop on an SQN in space exposed to various radiation baths (and showers) capable of liberating their less strongly bound electrons, taking into account recombination with ambient electrons. We consider, in particular, the cosmic background radiation, radiation from the sun, and diffuse galactic and extragalactic gamma-ray backgrounds. A possible dramatic signal of SQNs in explosive astrophysical events is noted.

Abers, E. S.↗

Electromagnetic Compatibility Considerations for International Space Station Payload Developers

The International Space Station (ISS) is a laboratory for scientific research, innovative technology development, and global education. The ISS provides a number of facilities and platforms for payload developers and investigators to conduct biological, microgravity, and Earth and space observation science, as well as for performing technology development. Due to the unique nature of the ISS vehicle and its electrical power and data systems, achieving electromagnetic compatibility (EMC) with the vehicle requires special considerations by the payload developer. The ISS electromagnetic interference (EMI) requirements and test methods are based on MIL-STD-461, “Electromagnetic Emissions and Susceptibility Requirements for the Control of Electromagnetic Interference”, Revision C, and MIL-STD-462, “Electromagnetic Interference Characteristics, Measurement of,” respectively. The low source impedance of the test setup requires special considerations when designing or selecting EMI power filters and switched mode power supplies. Many filters, suited for later revisions of MIL-STD-461, will result in non-compliant designs. ISS electrical power system power quality requirements, imposed to protect the stability of the system, can also affect EMI filter design. The selection and use of commercial-off-the-shelf (COTS) equipment for ISS applications requires special considerations to meet both EMC and crew safety requirements. Furthermore, the ISS environment can provide unique immunity challenges; if the payload developer ignores these challenges, the result is a possible loss of science or impact to technology demonstration. The ISS provides a unique opportunity for the science and technology development community. However, in order to be successful, the payload developer must incorporate special EMC considerations, many of which will be presented.

McCollum, Matthew↗

Principles of equivalence, Eotvos experiments, and gravitational red-shift experiments - The free fall of electromagnetic systems to post-post-Coulombian order

Free fall in an external static gravitational field of a composite test body consisting of electromagnetically interacting charged particles is analyzed using the TH-epsilon-mu formalism developed by Lightman and Lee (1973). The Lightman and Lee calculation that was carried out to 'post-Coulombian' order is extended to 'post-post-Coulombian' order, and violations of the weak equivalence principle are found which result from the magnetostatic self-energy of the test body. The current generation of Eotvos experiments is shown to test the cited formalism at first order in the external gravitational potential to an accuracy of 4 by 10 to the -10th power for electrostatic energies and 6 by 10 to the -6th power for magnetostatic energies. It is concluded that although the formalism can be tested to an accuracy of 0.04 for electrostatic energies at second order in the gravitational potential, a significant second-order test for magnetostatic energies would require Eotvos experiments accurate to better than one part in 10 to the 15th power.

Haugan, M. P.↗

Correlation of Noise Signature to Pulsed Power Events at the HERMES III Accelerator.

The HERMES III accelerator, which is located at Sandia National Laboratories' Tech Area IV, is the largest pulsed gamma X-ray source in the world. The accelerator is made up of 20 inductive cavities that are charged to 1 MV each by complex pulsed power circuitry. The firing time of the machine components ranges between the microsecond and nanosecond timescales. This results in a variety of electromagnetic frequencies when the accelerator fires. Testing was done to identify the HERMES electromagnetic noise signal and to map it to the various accelerator trigger events. This report will show the measurement methods used to capture the noise spectrum produced from the machine and correlate this noise signature with machine events.

43 PARTICLE ACCELERATORS↗

A Holistic Approach to Systems Development

Introduces a Holistic and Iterative Design Process. Continuous process but can be loosely divided into four stages. More effort spent early on in the design. Human-centered and Multidisciplinary. Emphasis on Life-Cycle Cost. Extensive use of modeling, simulation, mockups, human subjects, and proven technologies. Human-centered design doesn t mean the human factors discipline is the most important Disciplines should be involved in the design: Subsystem vendors, configuration management, operations research, manufacturing engineering, simulation/modeling, cost engineering, hardware engineering, software engineering, test and evaluation, human factors, electromagnetic compatibility, integrated logistics support, reliability/maintainability/availability, safety engineering, test equipment, training systems, design-to-cost, life cycle cost, application engineering etc. 9

Wong, Douglas T.↗

Relativistic quark model for the Omega- electromagnetic form factors

We compute the Omega- electromagnetic form factors and the decuplet baryon magnetic moments using a quark model application of the Covariant Spectator Theory. Our predictions for the Omega- electromagnetic form factors can be tested in the future by lattice QCD simulations at the physical strange quark mass.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effects of EMP Testing on Residential DC/AC Microinverters

Electromagnetic pulse (EMP) coupling into electronic devices can be destructive to components potentially causing device malfunction or failure. A large electromagnetic field generated from the EMP can induce large voltages and currents in components. As such, the effects of EMP on different devices needs to be understood to elucidate the effect of EMP on potentially vulnerable systems. This report presents test results for small-scale residential DC to AC solar panel microinverters that were subjected to high voltage impulses and currents. The impulses were intended to emulate an EMP coupling event to the AC and DC sides of the microinverter. State-of-health measurements were conducted to characterize device performance before and after each test.

42 ENGINEERING↗