Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTRON DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Integration of the FastIC front-end electronics into the Picosec MicroMegas detector

The Picosec MicroMegas collaboration aims to develop gaseous fast-timing detectors; experimentally, intrinsic time resolutions from around 50 ps to better than 20 ps are obtained, depending on the exact detector configuration. Parts of developments focus on exploring various options of fast-timing multi-channel front-end electronics, to meet the data processing demands of experimental applications. One option is the FastIC, which was developed for reading out positive and negative input polarity sensors with intrinsic amplification. In this paper, the first results from reading out the gaseous Picosec MicroMegas detector with the FastIC are presented. In laboratory studies, a basic description of the data processing chain was performed using a function generator. The results from test beam measurements are used to characterise the timing performance and the charge processing of the combination of FastIC and Picosec MicroMegas, as well as to demonstrate the possibility of a multi-channel detector readout. Although the timing-at-threshold level of the FastIC introduces a time walk of around 1.5 ns, time resolutions of around 50 ps have been achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron bombardment charge-coupled device /CCD/ detectors for the vacuum ultraviolet

Development work is underway at Princeton and NRL on electronic-readout imaging detectors for the VUV which are based on electron-bombardment CCD arrays and opaque alkali-halide photocathodes. These detectors provide single-photoelectron detection capability and wide dynamic range combined with almost the maximum possible quantum efficiency (in excess of 50% in the wavelength range below 1300 A). The Princeton work is based on an oblique-focusing electron optical configuration, while the NRL program is based on a Schmidt optical system with opaque photocathode. Results of preliminary tests at Princeton and overall system concepts for the Princeton and NRL cameras are discussed, and applications to possible space astronomy studies are examined.

Lowrance, J. L.↗

Auroral electron energy spectra.

Auroral electron energy spectra measured from 180 to 250 km using electrostatic analyzer and channeltron detector, discussing electron flux

Ogilvie, K. W.↗

Sensors and detectors in NASA's future missions

Advances in electronics are responsible for major improvements in NASA's sensing and detection capabilities for future space missions. Technologies such as charge-transfer devices, tunable diode lasers, millimeter and submillimeter wave solid-state receiver components, large-scale circuit integration, new electronic materials and processing techniques, and novel detector electronics are contributing to the goal of a tenfold increase in the capacity of data collection from future platforms and will be used for space exploration and utilization.

Rubin, B.↗

Measurements of atmospheric carbonyl sulfide during the NASA Chemical Instrumentation Test and Evaluation Project: Implications for the global COS budget

Atmospheric carbonyl sulfide COS concentrations were measured by three analytical systems during the Chemical Instrumentation Test and Evaluation (CITE 3) project. The three systems all used cryogenic sample preconcentration and gas chromatographic (GC) separation but differed in the method of detection. The FPD system used a flame photometric detector, the MS system used a mass selective detector, and the ECD-S system used a fluorinating catalyst followed by an electron capture detector. With the FPD system, we found a mean COS concentration of 510 ppt over the North Atlantic and 442 ppt over the Tropical Atlantic. With the ECD-S system, we found a mean COS concentration of 489 ppt over the North Atlantic and 419 ppt over the Tropical Atlantic. All three systems registered a latitudinal gradient in atmospheric COS of between 1.6 and 2.0 ppt per degree of latitude, with increasing COS concentrations northward which was similar to the gradient measured by Bingemer et al. (1990). It is difficult to reconcile the measured latitudinal concentration gradient with present theories of the global COS budget since the largest sink of COS is thought to be a flux to land plants, most of which are in the northern hemisphere.

Johnson, James E.↗

Michelson Interferometer (MINT)

MINT is a Michelson interferometer designed to measure the thermal emission from the earth at high spectral resolution (2/cm) over a broad spectral range (250-1700/cm, 6-40 mu m) with contiguous 3-pixel wide (12 mrad, 8 km field of view) along-track sampling. MINT is particularly well suited for monitoring cloud properties (cloud cover, effective temperature, optical thickness, ice/water phase, and effective particle size) both day and night, as well as tropospheric water vapor, ozone, and temperature. The key instrument characteristics that make MINT ideally suited for decadal monitoring purposes are: high wavelength to wavelength precision across the full IR spectrum with high spectral resolution; space-proven long-term durability and calibration stability; and small size, low cost, low risk instrument incorporating the latest detector and electronics technology. MINT also incorporates simplicity in design and operation by utilizing passively cooled DTGS detectors and nadir viewing geometry (with target motion compensation). MINT measurement objectives, instrument characteristics, and key advantages are summarized in this paper.

Lacis, Andrew↗

Novel multiplexing technique for detector and mixer arrays

Future space submillimeter telescopes will require large-format imaging detector arrays to perform state-of-the-art astronomical observations. A crucial issue related to a focal plane array is a readout scheme which is combatible with large numbers of cryogenic detectors elements.

submillimeter↗

Advanced technical developments in support of scientific experiments in space

A technique was developed for preparing solid state, lithium-drifted silicon detectors. Hollow cylindrical detectors were built and tested for possible use as anticoincidence shields to replace conventional plastic scintillators and photomultipliers. A fission cell was developed for the Pioneer F/G instruments and the IMP I subsystem. An electron current detector was developed for Jovian belt measurements of electron flux. A number of circuits and semiconductor devices was also developed.

Lamport, J. E.↗

Advanced combined iodine dispenser and detector

A total weight of 1.23 kg (2.7 lb), a total volume of 1213 cu m (74 cu in), and an average power consumption of 5.5W was achieved in the advanced combined iodine dispenser/detector by integrating the detector with the iodine source, arranging all iodinator components within a compact package and lowering the parasitic power to the detector and electronics circuits. These achievements surpassed the design goals of 1.36 kg (3.0 lb), 1671 cu m (102 cu in) and 8W. The reliability and maintainability were improved by reducing the detector lamp power, using an interchangeable lamp concept, making the electronic circuit boards easily accessible, providing redundant water seals and improving the accessibility to the iodine accumulator for refilling. The system was designed to iodinate (to 5 ppm iodine) the fuel cell water generated during 27 seven-day orbiter missions (equivalent to 18,500 kg (40,700 lb) of water) before the unit must be recharged with iodine crystals.

Lantz, J. B.↗

The C shell, an active detector of UH nuclei

This paper gives a brief description of the current status of the present program to develop a modular array of large electronic particle detectors. These modules were designed to study the UH nuclei in the cosmic radiation with eventual deployment on the Space Station or at a lunar base. This array would determine the abundances of elements from iron to the actinides and directly measure the energies of the lower energy nuclei. If the array was deployed on the Space Station, it would use the geomagnetic threshold to place limits on the higher energy nuclei, thus studying the energy spectrum up to about 10 GeV/n. Deployed at a lunar base, it would detect nuclei with energies down to the instrumental limit. Smaller versions could be flown on balloons to test and refine the modules.

Waddington, C. J.↗

Observations of the 3-D distribution of interplanetary electrons and ions from solar wind plasma to low energy cosmic rays

The 3-D Plasma and Energetic Particle instrument on the GGS Wind spacecraft (launched November 1, 1994) is designed to make measurements of the full three-dimensional distribution of suprathermal electrons and ions from solar wind plasma to low energy cosmic rays, with high sensitivity, wide dynamic range, good energy and angular resolution, and high time resolution. Three pairs of double-ended telescopes, each with two or three closely sandwiched passivated ion implanted silicon detectors measure electrons and ions from approximately 20 keV to greater than or equal to 300 keV. Four top-hat symmetrical spherical section electrostatic analyzers with microchannel plate detectors, a large and a small geometric factor analyzer for electrons and a similar pair for ions, cover from approximately 3 eV to 30 keV. We present preliminary observations of the electron and ion distributions in the absence of obvious solar impulsive events and upstream particles. The quiet time electron energy spectrum shows a smooth approximately power law fall-off extending from the halo population at a few hundred eV to well above approximately 100 keV The quiet time ion energy spectrum also shows significant fluxes over this energy range. Detailed 3-D distributions and their temporal variations will be presented.

Lin, R. P.↗

Exploring the keV-scale physics potential of CUORE

We present the analysis techniques developed to explore the keV-scale energy region of the Cryogenic Underground Observatory for Rare Events (CUORE) experiment, based on more than 2 metric ton yr of data collected over five years. By prioritizing a stricter selection over a larger exposure, we are able to optimize data selection for thresholds at 10 keV and 3 keV with 691 kg yr and 11 kg yr of data, respectively. We study how the performance varies among the 988-detector array with different detector characteristics and data-taking conditions. We achieve an average baseline resolution of 2.54 ±0.14 keV FWHM and 1.18 ±0.02 keV FWHM for the data selection at 10 keV and 3 keV, respectively. The analysis methods employed reduce the overall background by about an order of magnitude, reaching 2.06±0.05 counts/(keV kg days) and 16±2 counts/(keV kg days) at the thresholds of 10 keV and 3 keV. We evaluate for the first time the near-threshold reconstruction efficiencies of the CUORE experiment, and find these to be 50 ±2% and 26 ±4% at 10 keV and 3 keV, respectively. This analysis provides crucial insights into rare decay studies, new physics searches, and keV-scale background modeling with CUORE. We demonstrate that ton-scale cryogenic calorimeters can operate across a wide energy range, from keV to MeV, establishing their scalability as versatile detectors for rare event and dark matter physics. These findings also inform the optimization of future large mass cryogenic calorimeters to enhance the sensitivity to low-energy phenomena.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Active experiments in modifying spacecraft potential: Results from ATS-5 and ATS-6

Instruments on ATS-5 and ATS-6 were operated to study the phenomena of spacecraft charging. The ion engine neutralizers were operated in attempts to modify the spacecraft potentials. The neutralizer on ATS-5 is a hot filament emitting electrons, while the neutralizer on ATS-6 is a low energy plasma bridge. The diagnostics used were particle detectors, counting electrons and protons as a function of energy. Operations were conducted in daylight and eclipse. This report describes the processing data from these and other operations. Only preliminary analysis of some of this data has been carried out, with the following results: (1) electron emission does not perturb the status of a low potential satellite by more than 50 volts, (2) emission of a low energy plasma does not change low potentials by more than a few volts, (3) when ATS-6 enters eclipse in the presence of a high energy plasma, the neutralizer suppresses any rise in (within a few volts resolution), (4) when the electron emitter on ATS-5 is operated, it serves to discharge negative potentials from thousands to hundreds of volts.

Olsen, R.↗

Differential Mobility Spectrometry: Preliminary Findings on Determination of Fundamental Constants

The electron capture detector (ECD) has been used for 40+ years (1) to derive fundamental constants such as a compound's electron affinity. Given this historical perspective, it is not surprising that differential mobility spectrometry (DMS) might be used in a like manner. This paper will present data from a gas chromatography (GC)-DMS instrument that illustrates the potential capability of this device to derive fundamental constants for electron-capturing compounds. Potential energy curves will be used to provide possible explanation of the data.

Limero, Thomas↗

On the quiet-time increases of low energy cosmic ray electrons

With a detector on board the OGO-5 satellite, the flux and energy spectrum of electrons in the 10-30 MeV range has been continuously monitored from 1968 to 1972. Sudden increases by factors of up to 300 percent have been observed during solar quiet periods. These 'Quiet-Time Increases' abruptly die out above 30 MeV and correlate well with identical increases reported at lower energies leading to a flat relative energy spectrum. A large fraction of these electrons is most likely of Jovian origin.

Lheureux, J.↗

Radiation damage effects by electrons, protons, and neutrons in Si/Li/ detectors.

The degradation in performance of lithium-compensated silicon nuclear particle detectors induced by irradiation at room temperature with 0.6-MeV and 1.5-MeV electrons, 1.9-MeV protons, and fast neutrons from a plutonium-beryllium source has been investigated. With increasing fluence, the irradiations produced an increase of detector leakage current, noise, capacitance, and a degradation in the performance of the detector as a charged-particle energy spectrometer. Following the irradiations, annealing effects were observed when the detectors were reverse-biased at their recommended operating voltages. Upon removal of bias, a continuous degradation of detector performance characteristics occurred. Detectors which had been damaged by electrons and protons exhibited a stabilization in their characteristics within two weeks after irradiation, whereas detectors damaged by neutrons had a continuous degradation of performance over a period of several months.

Liu, Y. M.↗