Search NASA⌕ Search

SEARCH · Search NASA

Results for “ERROR CORRECTING DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Pushing the Boundaries of Coherence in Superconducting Quantum Systems at the SQMS Center for Computing, Sensing, and Metrology

This talk will highlight recent advances at the SQMS Center in understanding and mitigating decoherence in superconducting quantum systems, focusing on both transmon qubits and 3D superconducting cavities. I will present results from systematic studies of materials and devices, aimed at identifying key sources of loss: including two-level systems (TLS), quasiparticles, and other noise mechanisms. These studies span microwave loss characterization in materials such as niobium, tantalum, aluminum, and their native oxides, as well as substrate losses in silicon and sapphire. Using both qubits and cavities, we disentangle subsystem contributions to loss and develop a hierarchy of mitigation strategies. Through these efforts, we have achieved transmon coherence times exceeding one millisecond. I will also present investigations into quasiparticle dynamics, including bursts observed in qubits located above ground and in the Gran Sasso underground laboratory. Additional studies explore temperature dependence to distinguish between TLS and quasiparticle losses, and reveal that applying a magnetic field can reduce temporal T1 fluctuations in transmons. Building on these results, we demonstrate a record-coherence two-cell cavity-qudit system with coherence times exceeding 20 milliseconds. By leveraging sideband interactions and error-resilient protocols including measurement-based correction and post-selection, we achieve high-fidelity quantum state control. This includes preparation of Fock states up to N = 20 with fidelities over 95%, and two-mode entanglement with coherence-limited fidelities reaching 99.9% after post-selection. These achievements position the SQMS platform as a powerful foundation for scalable quantum information processing and high-dimensional qudit encodings. Finally, I will discuss how these ultra-coherent systems are being deployed in emerging quantum sensing applications, including dark matter searches and gravitational wave detection.

Roy, Tanay [Fermilab]↗

Correction for Neutral Pressure-Driven Signal in Radiated Power Measurements on Proto-MPEX

A pinhole camera using four-channel resistive bolometers was designed and implemented on the Prototype Material Plasma Exposure eXperiment (Proto-MPEX) to measure the plasma radiated power. Quantification of the radiated power is required for comprehensive power balance assessments but faces unique challenges on linear plasma devices due to weak absolute signal, compared to typical use in toroidal fusion plasmas, and high neutral pressure changes. Around 1 mTorr, the pressure-driven signal contribution was shown to overwhelm the radiated power signal in Proto-MPEX, found to be ~3 μW . Since the pressure-driven signals could not be predicted from first principle arguments, the signals were corrected using empirical models that take two experimental pressure measurements and the raw bolometer signal to reveal the radiated power signals. Four “gas-only” Proto-MPEX shots were taken, without the radio frequency (rf) plasma discharge, to train, optimize, and validate empirical models. The data included two pressure measurements at different locations along with the bolometer signal. Multiple models were tested; partial least-squares regression with a cross correlation method to account for the time offset in the pressure measurements provided the best combination of accuracy and stability. The model was validated to have a modeling error of 0.0036 V, which was lower than 10% of the expected radiated power signal. The model was tested on a different “gas-only” shot with a complete time-series data. For plasma operation shots, the corrected bolometer measurements were compared with an absolute extreme ultraviolet photodiode measurement and similarities and differences are discussed.

Lee, Seungsup↗

Rotation of the Sacrum During Bellyboard Pelvic Radiotherapy

Patients with cervical, uterine, and rectal carcinomas are usually treated in the prone position using the bellyboard positioning device. Specific and uncomfortable prone position gives rise to uncertainties in the daily set-up of patients during the treatment. During investigation of translational movements, rotational movements of the pelvis are observed and investigated. The film portal imaging is used to discover patient positioning errors during treatment. We defined the rotational set-up errors by angle deviations of the sacrum. Thirty-six patients were included in the study; 15 patients were followed during the whole treatment and 21 during the first 5 consecutive treatment days. The image acquisitions were completed in 84%. Systematic and random positioning errors were analyzed in 725 images. Approximately half of the patients had adjusted to the bellyboard in the first few fractions, with sacrum angles remaining the same for the rest of the treatment. The other half had drifts of the sacrum angle during the whole treatment. The rotation of the sacrum during treatment ranged up to 14 deg., causing the usual set-up verification and correction procedure to result in errors up to 15 mm. Rotational movements of the patient pelvis during bellyboard pelvis radiotherapy can introduce considerable patient position error.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-484: A New Method of Aligning Patient Setup Lasers in Radiation Therapy

Purpose: To develop a new method to align the patient setup lasers in radiation therapy and examine its validity and effectiveness. Methods: The new laser alignment method was realized by a device composed of both a metallic base plate and few acrylic transparent plates with a cross hair line on each of them. The holders of radiochromic films were prepared in the device to find a radiation isocenter. The right laser positions could be found optically by matching the shadows of all the cross hairs in the gantry head and the device. The repeatability and reproducibility (R and R) of laser alignments and the dependency of the alignment on the position error of the light source were evaluated by comparing the standard deviations and the means of the measured laser positions. After aligning the lasers optically, a radiation isocenter was found by a collimator spoke shot and the gantry spoke shot, and then the lasers were parallely translated to the isocenter. Results: In the R and R test, the standard deviation was 1.14 mm for the new method whereas it was 1.49 mm or 2.76 mm for the conventional method with either high- or low-precision levels. In the test of the dependency on the position error of the light source, the mean laser position was shifted by 5.3 mm corresponding to the shift of the light source, 4.8 mm for the new method, but for the conventional method the laser position was shifted more than 7 times than that. The positional shift could be corrected by a parallel translation to the isocenter in the new method. Conclusion: A new laser alignment method was devised for radiation therapy and tested successfully. The method enabled us to align the lasers easily and accurately without repetition, and all lasers could be finally aligned to the radiation isocenter.

60 APPLIED LIFE SCIENCES↗

Tore Supra LH transmitter upgrade, a new RF driver for the power spectrum

New real time tools have been developed for testing new 700kW/3.7GHz/CW klystrons and for the operations on very long plasma shots. After the commissioning of the 18 series tubes on the high power test bed facility, the installation of the first 8 klystrons in the Tore Supra transmitter and the adjustment tests on load, this upgrade work has been materialized during the last 2010 campaign by a successful operation on the Full Active Multijunction (FAM) C3 antenna, with new performances: 3.5MW/40s on plasma. The RF output power control in amplitude and phase has been improved for a better control of the wave spectrum launched into the plasma. The new klystrons have no modulating anode and the high cathode voltage must be adjusted with the RF input power in order to optimize the RF output power with a minimization of the thermal power losses in the collector. A new phase correction, depending on the 3 RF output power ranges used, has been introduced. The improvements made in 2009 and 2010 on the generic phase loop and the procedures used during the real time tests of the RF transfer functions in amplitude and phase are detailed below. All RF measurements systems, RF safety systems and the RF calibration procedures have been revised in order to have the best consistency, reproducibility and with a measurement error against the calorimetry measurement lower than 10%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparative Density Functional Theory Study of Magnetic Exchange Couplings in Dinuclear Transition-Metal Complexes

Multicenter transition-metal complexes (MCTMs) with magnetically interacting ions have been proposed as components for information-processing devices and storage units. For any practical application of MCTMs as magnetic units, it is crucial to characterize their magnetic behavior, and in particular, the isotropic magnetic exchange coupling, J, between its magnetic centers. Due to the large size of typical MCTMs, density functional theory is the only practical electronic structure method for evaluating the J coupling. Here, we assess the accuracy of different density functional approximations for predicting the magnetic couplings of eight dinuclear transition-metal complexes, including five dimanganese, two dicopper, and one divanadium with known reliable experimental J couplings spanning from ferromagnetic to strong antiferromagnetic. The density functionals considered include global hybrid functionals which mix semilocal density functional approximations and exact exchange with a fixed admixing parameter, six local hybrid functionals where the admixing parameters are extended to be spatially dependent, the SCAN and r 2 SCAN meta-generalized gradient approximations (GGAs), and two widely used GGAs. We found that global hybrids tested in this work have a tendency to over-correct the error in magnetic coupling parameters from the Perdew–Burke–Ernzerhof (PBE) GGA as seen for manganese complexes. The performance of local hybrid density functionals shows no improvement in terms of bias and is scattered without a clear trend, suggesting that more efforts are needed for the extension from global to local hybrid density functionals for this particular property. The SCAN and r 2 SCAN meta-GGAs are found to perform as well as benchmark global hybrids on most tested complexes. We further analyze the charge density redistribution of meta-GGAs as well as global and local hybrid density functionals with respect to that of PBE, in connection to the self-interaction error or delocalization error.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-T-52: A New Device for Quality Assurance of a Single Isocenter Technique for the Simultaneous Treatment of Multiple Brain Metastases

Purpose: Comprehensive quality assurance (QA) of a single isocenter technique for the simultaneous treatment of multiple brain metastases is presently impractical due to the time consuming nature of measuring each lesion’s dose on film or with a micro-chamber. Three dimensional diode array and full field film measurements are sometimes used to evaluate these plans, but gamma analysis may not reveal local errors that have significant effects on one or a few of several targets. This work aimed to design, build and test a phantom to simplify comprehensive measurement and evaluation. Methods: A phantom was designed with 28 stackable slabs. The top and bottom slabs are 1.5 centimeters (cm) in thickness, and central 26 slabs are 0.5 cm thick. When assembled with radiochromic film in all 27 gaps, the phantom measures 16.5 x 15 x 19 cm. Etchings were designed to aide in identification of specific film planes on computed tomography (CT) images and correlation of individual PTVs with closest bisecting planes. Patient verification plans with a total of 16 PTVs were calculated on the phantom CT, and test deliveries both with and without couch kicks were performed to test the ability to identify correct film placements and subsequent PTV specific dose distributions on the films. Results: Bisecting planes corresponding to PTV locations were easily identified, and PTV specific dose distributions were clear for all 16 targets. For deliveries with couch kicks, the phantom PTV dose distributions closely approximated those calculated on the patient’s CT. For deliveries without couch kicks, PTV specific dosimetry was also possible, although the distributions had ‘ghosts’ equaling the number of couch kicks, with distance between ghosts increasing with distance from the isocenter. Conclusion: A new phantom facilitates fast comprehensive commissioning validation and PTV specific dosimetry for a single isocenter technique for treating multiple brain metastases. This work was partially funded by CIRS, Inc.

60 APPLIED LIFE SCIENCES↗

SU-C-16A-01: In Vivo Source Position Verification in High Dose Rate (HDR) Prostate Brachytherapy Using a Flat Panel Imager: Initial Clinical Experience

Purpose: We report our initial clinical experience with a novel position-sensitive source-tracking system based on a flat panel imager. The system has been trialled with 4 prostate HDR brachytherapy patients (8 treatment fractions) in this initial study. Methods: The flat panel imaging system was mounted under a customised carbon fibre couch top assembly (Figure 1). Three gold fiducial markers were implanted into the prostate of each patient at the time of catheter placement. X-ray dwell position markers were inserted into three catheters and a radiograph acquired to locate the implant relative to the imaging device. During treatment, as the HDR source dwells were delivered, images were acquired and processed to determine the position of the source in the patient. Source positions measured by the imaging device were compared to the treatment plan for verification of treatment delivery. Results: Measured dwell positions provided verification of relative dwell spacing within and between catheters, in the coronal plane. Measurements were typically within 2.0mm (0.2mm – 3.3mm, s.d. 0.8mm) of the planned positions over 60 dwells (Figure 2). Discrimination between larger dwell intervals and catheter differentiation were clear. This confirms important delivery attributes such as correct transfer tube connection, source step size, relative catheter positions and therefore overall correct plan selection and delivery. The fiducial markers, visible on the radiograph, provided verification of treatment delivery to the correct anatomical location. The absolute position of the dwells was determined by comparing the measured dwell positions with the x-ray markers from the radiograph, validating the programmed treatment indexer length. The total impact on procedure time was less than 5 minutes. Conclusion: The novel, noninvasive HDR brachytherapy treatment verification system was used clinically with minor impact on workflow. The system allows verification of correct treatment delivery, free of most potential human related errors identified in ICRP 97. This research is supported by funding from the Australian Government Department of Health through Cancer Australia grant no. 616614.

60 APPLIED LIFE SCIENCES↗

Defects in Na-, K-, and Cd-Doped CuInSe$_2$ : Canonical Thermodynamics Based on Ab Initio Calculations

In this work. we extend a canonical-thermodynamic method for computing intrinsic point defect concentrations as a function of chemical stoichiometry and temperature to include extrinsic defect contributions, while applying this method to study defects in CuInSe 2 . This technique relies on a large set of defect formation energies calculated from first principles, which require corrections for known errors arising from spurious interactions. Guided by recent experimental work exhibiting the complex interplay between Na, K, and Cd incorporation, we examine the behavior of dominant defects as the material composition varies under experimentally relevant conditions. In addition to identifying the regions of composition-parameter space relevant to the incorporation of impurities Na, K, and Cd, and stable against the formation of secondary compounds, we further study defect kinetics susceptible to the presence of these impurities. From this analysis, we propose a simple model for the enhanced diffusion of Cu-vacancies mediated by K, which could lead to the enhanced incorporation of Cd observed experimentally.

42 ENGINEERING↗

Hybrid quantum-classical hierarchy for mitigation of decoherence and determination of excited states

Using quantum devices supported by classical computational resources is a promising approach to quantum-enabled computation. One powerful example of such a hybrid quantum-classical approach optimized for classically intractable eigenvalue problems is the variational quantum eigensolver, built to utilize quantum resources for the solution of eigenvalue problems and optimizations with minimal coherence time requirements by leveraging classical computational resources. These algorithms have been placed as leaders among the candidates for the first to achieve supremacy over classical computation. Here, we provide evidence for the conjecture that variational approaches can automatically suppress even nonsystematic decoherence errors by introducing an exactly solvable channel model of variational state preparation. Moreover, we develop a more general hierarchy of measurement and classical computation that allows one to obtain increasingly accurate solutions by leveraging additional measurements and classical resources. In conclusion, we demonstrate numerically on a sample electronic system that this method both allows for the accurate determination of excited electronic states as well as reduces the impact of decoherence, without using any additional quantum coherence time or formal error-correction codes.

McClean, Jarrod R.↗

Mechanical characterization of the Varian Exact-arm and R-arm support systems for eight aS500 electronic portal imaging devices

Purpose: The aim of this study is to compare the positioning accuracy at different gantry angles of two electronic portal imaging devices (EPIDs) support arm systems by using EPID difference images as a measure for displacement. This work presents a comparison of the mechanical performance of eight Varian aS500 (Varian Medical Systems, Palo Alto, CA) EPIDs, mounted using either the Varian Exact-arm or R-arm. Methods: The mechanical performance of the two arm systems was compared by investigating the variation in sensitivity with gantry angle, both before and after the EPID position was adjusted after gantry rotation. Positional errors were investigated by subtracting images from a reference image taken at gantry 0 deg., and the amplitude of the peaks and troughs at the field edges for longitudinal (radial) and lateral (transverse) profiles across the resulting image was related to the distance of displacement. Calibration curves based on a pixel-by-pixel shift were generated for each EPID and the Varian hand pendant accuracy was compared to the calibration data. Results: The response of the EPIDs was found to change with gantry rotation, with the largest difference at 180 deg. The Exact-arm was found to correct well for any displacement, while the R-arm tended to overcorrect following repositioning using the hand pendant. The calibration curves were consistent within each set of matched linacs, and the hand pendant accuracy was similar for both arm systems, although generally in different directions. With respect to gantry rotation effects, the mechanical performance of the Exact-arm systems was found to be much better than that of the R-arm systems. At gantry positions 90 deg., 270 deg., and 180 deg. the average misalignment in the longitudinal direction was +4.2{+-}0.2, +1.8{+-}1.6, and +7.4{+-}0.5 mm for the R-arms, and +2.9{+-}0.2, +2.1{+-}0.8, and +4.9{+-}0.7 mm for the Exact-arms. In the lateral direction the average positional errors were +2.1{+-}0.4, -4.7{+-}0.4, and -2.5{+-}0.5 mm for the R-arms, and -0.3{+-}0.3, -0.5{+-}0.3, and -0.4{+-}0.2 mm for the Exact-arms. The hand pendant correction had minimal impact in the lateral direction for both arm systems. However in the longitudinal direction the mean errors for the R-arms were +3.4{+-}0.7, +1.5{+-}0.6, and +4.6{+-}0.7 mm at gantry angles 90 deg., 270 deg., and 180 deg., and the equivalent Exact-arm errors were +0.9{+-}0.3, +1.2{+-}0.3, and +1.9{+-}0.9 mm, respectively. Conclusions: The performance of the EPIDs demonstrate that the Exact-arm system provides a more reproducible position and better agreement with the EPID position as indicated on the EPID pendant at all gantry angles than the R-arm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental evaluation of an online gamma-camera imaging of permanent seed implantation (OGIPSI) prototype for partial breast irradiation

Previously, our team used Monte Carlo simulation to demonstrate that a gamma camera could potentially be used as an online image guidance device to visualize seeds during permanent breast seed implant procedures. This could allow for intraoperative correction if seeds have been misplaced. The objective of this study is to describe an experimental evaluation of an online gamma-camera imaging of permanent seed implantation (OGIPSI) prototype. The OGIPSI device is intended to be able to detect a seed misplacement of 5 mm or more within an imaging time of 2 min or less. The device was constructed by fitting a custom built brass collimator (16 mm height, 0.65 mm hole pitch, 0.15 mm septal thickness) on a 64 pixel linear array CZT detector (eValuator-2000, eV Products, Saxonburg, PA). Two-dimensional projection images of seed distributions were acquired by the use of a digitally controlled translation stage. Spatial resolution and noise characteristics of the detector were measured. The ability and time needed for the OGIPSI device to image the seeds and to detect cold spots was tested using an anthropomorphic breast phantom. Mimicking a real treatment plan, a total of 52 {sup 103}Pd seeds of 65.8 MBq each were placed on three different layers at appropriate depths within the phantom. The seeds were reliably detected within 30 s with a median error in localization of 1 mm. In conclusion, an OGIPSI device can potentially be used for image guidance of permanent brachytherapy applications in the breast and, possibly, other sites.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

PMU Data Integrity Evaluation through Analytics on a Virtual Test-Bed

Power systems are rapidly becoming populated by phasor measurement units (PMUs) in ever increasing numbers. PMUs are critical components of today s energy management systems, designed to enable near real-time wide area monitoring and control of the electric power system. They are able to measure highly accurate bus voltage phasors as well as branch current phasors incident to the buses at which PMUs are equipped. Synchrophasor data is used for applications varying from state estimation, islanding control, identifying outages, voltage stability detection and correction, disturbance recording, and others. However, PMU-measured readings may suffer from errors due to meter biases or drifts, incorrect configurations, or even cyber-attacks. Furthermore, the testing of early PMUs showed a large disparity between the reported values from PMUs provided by different manufacturers, particularly when frequency was off-nominal, during dynamic events, and when harmonic/inter-harmonic content was present. Detection and identification of PMU gross measurement errors are thus crucial in maintaining highly accurate phasor readings throughout the system. In this paper, we present our work in conducting analytics to determine the trustworthiness and worth of the PMU readings collected across an electric network system. By implementing the IEEE 118 bus test case on a virtual test bed (VTB) , we are able to emulate PMU readings (bus voltage and branch current phasors in addition to bus frequencies) under normal and abnormal conditions using (virtual) PMU sensors deployed across major substations in the network. We emulate a variety of failures such as bus, line, transformer, generator, and/or load failures. Data analytics on the voltage phase angles and frequencies collected from the PMUs show that specious (or compromised) PMU device(s) can be identified through abnormal behaviour by comparing the trend of its frequency and phase angle reading with the ensemble of all other PMU readings in the network. If the reading trend of a particular PMU deviates from the weighted average of the reading trends of other PMUs at nearby substations, then it is likely that the PMU is malfunctioning. We assign a weight to each PMU denoting how electric-topology-wise close it is from where the PMU under consideration is located. The closer a PMU is, the higher the weight it has. To compute the closeness between two nodes in the power network, we employ a form of the resistance distance metric. It computes the electrical distance by taking into consideration the underlying topology as well as the physical laws that govern the electrical connections or flows between the network components. The detection accuracy of erroneous PMUs should be improved by employing this metric. We present results to validate the proposed approach. We also discuss the effectiveness of using an end-to-end VTB approach that allows us to investigate different types of failures and their responses as seen by the ensemble of PMUs. The collected data on certain types of events may be amenable to certain types of analysis (e.g., alerting for sudden changes can be done on a small window of data) and hence determine the data analytics architectures is required to evaluate the streaming PMU data.

and data analytics architecture.↗

Discrimination of correlated and entangling quantum channels with selective process tomography

The accurate and reliable characterization of quantum dynamical processes underlies efforts to validate quantum technologies, where discrimination between competing models of observed behaviors inform efforts to fabricate and operate qubit devices. We present a protocol for quantum channel discrimination that leverages advances in direct characterization of quantum dynamics (DCQD) codes. We demonstrate that DCQD codes enable selective process tomography to improve discrimination between entangling and correlated quantum dynamics. Numerical simulations show selective process tomography requires only a few measurement configurations to achieve a low false alarm rate and that the DCQD encoding improves the resilience of the protocol to hidden sources of noise. Lastly, our results show that selective process tomography with DCQD codes is useful for efficiently distinguishing sources of correlated crosstalk from uncorrelated noise in current and future experimental platforms.

97 MATHEMATICS AND COMPUTING↗

Control of Edge Transport Barrier relaxations using Resonant Magnetic Perturbations

In divertor tokamak plasmas, an Edge Transport Barrier forms during the L-H transition. A poloidal shear flow has been shown to play a crucial role in the barrier sustainement. The H regime, obtained for a critical value of the heating power, is promising for the next generation of tokamak experiments such as ITER. However, an instability known as Edge Localized Mode (ELM) develops as the power is increased further. ELMs are characterized by intermittent bursts in the radial heat flux, therefore causing the transport barrier to relax quasi-periodically. Over the last decade, the possibility of controlling ELMs has become more and more plausible, as recent experiments were carried out on DIII-D using I-coils, on JET using error field correction coils, and on TEXTOR using an ergodic divertor. These experimental studies demonstrate a qualitative control over the ELMs by imposing a magnetostatic perturbation at the plasma edge. However, in order to get any quantitative result, much work has to be done in the understanding of ELM dynamics. In this work, we present results from numerical simulations of Resistive Ballooning Mode (RBM) turbulence reproducing the stabilization of barrier relaxations by a static magnetic perturbation. We focus our study on the edge region around the resonant surface q = 3. We use the TEXTOR tokamak geometry, and plasma parameters close to those used in typical experiments on this machine.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Correction of the axial asymmetry of the poloidal magnetic field in the Globus-M spherical tokamak

The toroidal inhomogeneity of the poloidal magnetic field-the so-called error fields that arise due to imperfections in manufacturing and assembling of the electromagnetic system-was measured in the Globus-M spherical tokamak. A substantial inhomogeneity corresponding to the n = 1 mode, which gave rise to a locked mode and led to discharge disruption, was revealed. After compensation of this inhomogeneity with the help of special correction coils, the discharge duration increased and the global plasma parameters improved substantially. A technique for determining and compensating the n = 1 mode inhomogeneity is described, the measured dependences of the penetration threshold of the m = 2/n = 1 mode on the plasma parameters are given, and results of experiments in which record parameters for the Globus-M tokamak were achieved after correction of the poloidal magnetic field are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-J-258: Inter- and Intra-Fraction Setup Stability and Couch Change Tolerance for Image Guided Radiation Therapy

Purpose: Immobilization devices combine rigid patient fixation as well as comfort and play a key role providing the stability required for accurate radiation delivery. In the setup step, couch re-positioning needed to align the patient is derived via registration of acquired versus reference image. For subsequent fractions, replicating the initial setup should yield identical alignment errors when compared to the reference. This is not always the case and further couch re-positioning can be needed. An important quality assurance measure is to set couch tolerances beyond which additional investigations are needed. The purpose of this work was to study the inter-fraction couch changes needed to re-align the patient and the intra-fraction stability of the alignment as a guide to establish the couch tolerances. Methods: Data from twelve patients treated on the Accuray CyberKnife (CK) system for fractionated intracranial radiotherapy and immobilized with Aquaplast RT, U-frame, F-Head-Support (Qfix, PA, USA) was used. Each fraction involved image acquisitions and registration with the reference to re-align the patient. The absolute couch position corresponding to the approved setup alignment was recorded per fraction. Intra-fraction set-up corrections were recorded throughout the treatment. Results: The average approved setup alignment was 0.03±0.28mm, 0.15±0.22mm, 0.06±0.31mm in the L/R, A/P, S/I directions respectively and 0.00±0.35degrees, 0.03±0.32degrees, 0.08±0.45degrees for roll, pitch and yaw respectively. The inter-fraction reproducibility of the couch position was 6.65mm, 10.55mm, and 4.77mm in the L/R, A/P and S/I directions respectively and 0.82degrees, 0.71degrees for roll and pitch respectively. Intra-fraction monitoring showed small average errors of 0.21±0.21mm, 0.00±0.08mm, 0.23±0.22mm in the L/R, A/P, S/I directions respectively and 0.03±0.12degrees, 0.04±0.25degrees, and 0.13±0.15degrees in the roll, pitch and yaw respectively. Conclusion: The inter-fraction reproducibility should serve as a guide to couch tolerances, specific to a site and immobilization. More patients need to be included to make general conclusions.

60 APPLIED LIFE SCIENCES↗

An Extreme-precision Radial-velocity Pipeline: First Radial Velocities from EXPRES

The EXtreme-PREcision Spectrograph (EXPRES) is an environmentally stabilized, fiber-fed, R = 137,500, optical spectrograph. It was recently commissioned at the 4.3 m Lowell Discovery Telescope near Flagstaff, Arizona. The spectrograph was designed with a target radial-velocity (RV) precision of 30 cm s{sup −1}. In addition to instrumental innovations, the EXPRES pipeline, presented here, is the first on-sky, optical, fiber-fed spectrograph to employ many novel techniques—including an “extended flat” fiber used for wavelength-dependent quantum efficiency characterization of the CCD, a flat-relative optimal extraction algorithm, chromatic barycentric corrections, chromatic calibration offsets, and an ultra-precise laser frequency comb for wavelength calibration. We describe the reduction, calibration, and RV analysis pipeline used for EXPRES and present an example of our current sub-meter-per-second RV measurement precision, which reaches a formal, single-measurement error of 0.3 m s{sup −1} for an observation with a per-pixel signal-to-noise ratio of 250. These velocities yield an orbital solution on the known exoplanet host 51 Peg that matches literature values with a residual rms of 0.895 m s{sup −1}.

79 ASTRONOMY AND ASTROPHYSICS↗