Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electron Accelerators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Conceptual Design of an Electron Accelerator for Bio-Solid Waste Treatment.

Several studies have identified electron beam (EB) irradiation of municipal wastewater and bio-solids as an effective and promising approach to the environmental remediation of the enormous quantities of human waste created by a growing world-wide population and increased urbanization. However, despite the technical success of experimental and pilot programs over the last several decades, the technique is still not in commercial use anywhere in the world. In addition, the report also identifies the need for “Financial and infrastructure participation from a utility for demonstration project” and “Education and awareness of safety of utilizing electron beam technology” as two additional roadblocks preventing technology adoption of EB treatment for bio-solids. In this concept design, we begin to address these barriers by working with Metropolitan Water Reclamation District of Greater Chicago (MWRD) and by the applying the latest accelerator technologies developed at Fermilab and within the DOE Office of Science laboratory complex.

43 PARTICLE ACCELERATORS↗

Laser-heated capillary discharge plasma waveguides for electron acceleration to 8 GeV

A plasma channel created by the combination of a capillary discharge and inverse Bremsstrahlung laser heating enabled the generation of electron bunches with energy up to 7.8 GeV in a laser-driven plasma accelerator. The capillary discharge created an initial plasma channel and was used to tune the plasma temperature, which optimized laser heating. Although optimized colder initial plasma temperatures reduced the ionization degree, subsequent ionization from the heater pulse created a fully ionized plasma on-axis. The heater pulse duration was chosen to be longer than the hydrodynamic timescale of ≈ 1 ns, such that later temporal slices were more efficiently guided by the channel created by the front of the pulse. Here, simulations are presented which show that this thermal self-guiding of the heater pulse enabled channel formation over 20 cm. The post-heated channel had lower on-axis density and increased focusing strength compared to relying on the discharge alone, which allowed for guiding of relativistically intense laser pulses with a peak power of 0.85 PW and wakefield acceleration over 15 diffraction lengths. Electrons were injected into the wake in multiple buckets and times, leading to several electron bunches with different peak energies. To create single electron bunches with low energy spread, experiments using localized ionization injection inside a capillary discharge waveguide were performed. A single injected bunch with energy 1.6 GeV, charge 38 pC, divergence 1 mrad, and relative energy spread below 2% full-width half-maximum was produced in a 3.3 cm-long capillary discharge waveguide. This development shows promise for mitigation of energy spread and future high efficiency staged acceleration experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

TeraChem: A graphical processing unit-accelerated electronic structure package for large-scale ab initio molecular dynamics

TeraChem was born in 2008 with the goal of providing fast on-the-fly electronic structure calculations to facilitate ab initio molecular dynamics studies of large biochemical systems such as photoswitchable proteins and multichromophoric antenna complexes. Originally developed for videogaming applications, graphics processing units (GPUs) offered a low-cost parallel computer architecture that became more accessible for general-purpose GPU computing with the release of CUDA in 2007. The evaluation of the electron repulsion integrals (ERIs) is a major bottleneck in electronic structure codes and provides an attractive target for acceleration on GPUs. Thus, highly efficient routines for evaluation of and contractions between the ERIs and density matrices were implemented in TeraChem. Here, electronic structure methods were developed and implemented to leverage these integral contraction routines, resulting in the first quantum chemistry package designed from the ground up for GPUs. This GPU acceleration makes TeraChem capable of performing large-scale ground and excited state calculations in the gas and condensed phase. Today, TeraChem's speed forms the basis for a suite of quantum chemistry applications, including optimization and dynamics of proteins, automated and interactive chemical discovery tools, and large-scale nonadiabatic dynamics simulations.

74 ATOMIC AND MOLECULAR PHYSICS↗

Submillimeter-Resolution Radiography of Shielded Structures with Laser-Accelerated Electron Beams

We investigate the use of energetic electron beams for high-resolution radiography of flaws embedded in thick solid objects. A bright, monoenergetic electron beam (with energy >100 MeV) was generated by the process of laser-wakefield acceleration through the interaction of 50-TW, 30-fs laser pulses with a supersonic helium jet. The high energy, low divergence, and small source size of these beams make them ideal for high-resolution radiographic studies of cracks or voids embedded in dense materials that are placed at a large distance from the source. We report radiographic imaging of steel with submillimeter resolution.

36 MATERIALS SCIENCE↗

UNDULATOR-BASED LASER WAKEFIELD ACCELERATOR ELECTRON BEAM DIAGNOSTIC

to couple the THUNDER undulator to the LOASIS Lawrence Berkeley National Laboratory (LBNL) laser wakefield accelerator (LWFA). Currently the LWFA has achieved quasi-monoenergetic electron beams with energies up to 1 GeV. These ultra-short, high-peak-current, electron beams are ideal for driving a compact XUV free electron laser (FEL). Understanding the electron beam properties such as the energy spread and emittance is critical for achieving high quality light sources with high brightness. By using an insertion device such as an undulator and observing changes in the spontaneous emission spectrum, the electron beam energy spread and emittance can be measured with high precision. The initial experiments will use spontaneous emission from 1.5 m of undulator. Later experiments will use up to 5 m of undulator with a goal of a high gain, XUV FEL.

43 PARTICLE ACCELERATORS↗

Radioactivity and electron acceleration in supernova remnants

We argue that the decays of radioactive nuclei related to {sup 44}Ti and {sup 56}Ni ejected during supernova explosions can provide a vast pool of mildly relativistic positrons and electrons which are further accelerated to ultrarelativistic energies by reverse and forward shocks. This interesting link between two independent processes - the radioactivity and the particle acceleration - can be a clue for solution of the well known theoretical problem of electron injection in supernova remnants. In the case of the brightest radio source Cas A, we demonstrate that the radioactivity can supply adequate number of energetic electrons and positrons for interpretation of observational data provided that they are stochastically preaccelerated in the upstream regions of the forward and reverse shocks.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A study on leakage radiation dose at ELV-4 electron accelerator bunker

Shielding is an important aspect in the safety of an accelerator and the most important aspects of a bunker shielding is the door. The bunker’s door should be designed properly to minimize the leakage radiation and shall not exceed the permitted limit of 2.5μSv/hr. In determining the leakage radiation dose that passed through the door and gaps between the door and the wall, 2-dimensional manual calculations are often used. This method is hard to perform because visual 2-dimensional is limited and is also very difficult in the real situation. Therefore estimation values are normally performed. In doing so, the construction cost would be higher because of overestimate or underestimate which require costly modification to the bunker. Therefore in this study, two methods are introduced to overcome the problem such as simulation using MCNPX Version 2.6.0 software and manual calculation using 3-dimensional model from Autodesk Inventor 2010 software. The values from the two methods were eventually compared to the real values from direct measurements using Ludlum Model 3 with Model 44-9 probe survey meter.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Attosecond Thomson-scattering x-ray source driven by laser-based electron acceleration

The possibility of producing attosecond x-rays through Thomson scattering of laser light off laser-driven relativistic electron beams is investigated. For a ≤200-as, tens-MeV electron bunch produced with laser ponderomotive-force acceleration in a plasma wire, exceeding 10{sup 6} photons/s in the form of ∼160 as pulses in the range of 3–300 keV are predicted, with a peak brightness of ≥5 × 10{sup 20} photons/(s mm{sup 2} mrad{sup 2} 0.1% bandwidth). Our study suggests that the physical scheme discussed in this work can be used for an ultrafast (attosecond) x-ray source, which is the most beneficial for time-resolved atomic physics, dubbed “attosecond physics.”.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Tunable High Spatio-Spectral Purity Undulator Radiation from a Transported Laser Plasma Accelerated Electron Beam

Undulator based synchrotron light sources and Free Electron Lasers (FELs) are valuable modern probes of matter with high temporal and spatial resolution. Laser Plasma Accelerators (LPAs), delivering GeV electron beams in few centimeters, are good candidates for future compact light sources. However the barriers set by the large energy spread, divergence and shot-to-shot fluctuations require a specific transport line, to shape the electron beam phase space for achieving ultrashort undulator synchrotron radiation suitable for users and even for achieving FEL amplification. Proof-of-principle LPA based undulator emission, with strong electron focusing or transport, does not yet exhibit the full specific radiation properties. We report on the generation of undulator radiation with an LPA beam based manipulation in a dedicated transport line with versatile properties. After evidencing the specific spatio-spectral signature, we tune the resonant wavelength within 200–300 nm by modification of the electron beam energy and the undulator field. We achieve a wavelength stability of 2.6%. We demonstrate that we can control the spatio-spectral purity and spectral brightness by reducing the energy range inside the chicane. We have also observed the second harmonic emission of the undulator.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental Evidence of Radiation Reaction in the Collision of a High-Intensity Laser Pulse with a Laser-Wakefield Accelerated Electron Beam

The dynamics of energetic particles in strong electromagnetic fields can be heavily influenced by the energy loss arising from the emission of radiation during acceleration, known as radiation reaction. When interacting with a high-energy electron beam, today’s lasers are sufficiently intense to explore the transition between the classical and quantum radiation reaction regimes. We present evidence of radiation reaction in the collision of an ultrarelativistic electron beam generated by laser-wakefield acceleration ( ϵ > 500 MeV ) with an intense laser pulse (a 0 > 10). We measure an energy loss in the postcollision electron spectrum that is correlated with the detected signal of hard photons (γ rays), consistent with a quantum description of radiation reaction. The generated γ rays have the highest energies yet reported from an all-optical inverse Compton scattering scheme, with critical energy ϵ crit > 30 MeV.

43 PARTICLE ACCELERATORS↗

Electron acceleration in a warm magnetized plasma-filled cylindrical waveguide

The effect of plasma-electron collision and their thermal motion is investigated on the externally injected electron in a warm magnetized plasma-filled cylindrical waveguide of cross section of 13.68 cm{sup 2}. The numerical results are presented for the external electron-energy gain and its trajectory in a nonrelativistic {gamma}{sub e}=1 and stationary v{sub 0}=0 warm magnetized plasma-filled waveguide. Results shows that for an electron-cyclotron frequency {omega}{sub c} greater than the electron-plasma frequency {omega}{sub p}, a 100 keV electron acquires a 1.74 MeV energy in a 2.5 cm distance for plasma density n{sub 0}=1.08x10{sup 17}/m{sup 3}, magnetic field B{sub 0}=0.193 T, microwave frequency f=7.64 GHz, plasma-electron thermal velocity v{sub th}=0.2c, and plasma-electron collision frequency {nu}=4 GHz, which is lower than the 7 MeV electron energy in a cold magnetized plasma-waveguide case. Space-charge effects and other nonlinear effects are assumed to be negligible in this model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Enhanced electron acceleration by high-intensity lasers in extended (confined) preplasma in cone targets

Here we report on experimental results from a high-intensity laser interaction with cone targets that increase the number (×3) and temperature (×3) of the measured hot electrons over a traditional planar target. This increase is caused by a substantial increase in the plasma density within the cone target geometry, which was induced by 17 ± 9 mJ prepulse that arrived 1.5 ns prior to the main high intensity (>10 19 W/cm 2 ). Three-dimensional hydrodynamic simulations are conducted using hydra which show that the cone targets create substantially longer and denser plasma than planar targets due to the geometric confinement of the expanding plasma. The density within the cone is a several hundred-micron plasma “shelf” with a density of approximately 10 20 n e /cc. The HYDRA simulated plasma densities are used as the initial conditions for two-dimensional particle-in-cell simulations using EPOCH. These simulations show that the main acceleration mechanism is direct-laser-acceleration, with close agreement between experimentally measured and simulated electron temperatures. Further analysis is conducted to investigate the acceleration of the electrons within the long plasma generated within a compound parabolic concentrator by the prepulse.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

All-Optical Steering of Laser-Wakefield-Accelerated Electron Beams

We investigate the influence of a tilted laser-pulse-intensity front on laser-wakefield acceleration. Such asymmetric light pulses may be exploited to obtain control over the electron-bunch-pointing direction and in our case allowed for reproducible electron-beam steering in an all-optical way within an 8 mrad opening window with respect to the initial laser axis. We also discovered evidence of collective electron-betatron oscillations due to off-axis electron injection into the wakefield induced by a pulse-front tilt. These findings are supported by 3D particle-in-cell simulations.

43 PARTICLE ACCELERATORS↗

SU-E-J-200: Operation of An Electron Accelerator On An Integrated MR-Linac System

Purpose: An integrated MRI guided radiotherapy system poses a challenge of operating a linear accelerator in the presence of a magnetic field as the magnetic force acting on the electrons could Result in radiation source displacement and subsequent reduction of dose output. It was the purpose of this work to test the performance of a linac in the presence of a 1.5T MRI system. Methods: The first experimental MRI guided radiotherapy system at UMC-Utrecht consisting of an Elekta linac rotating around a 1.5T Magnex magnet was examined. A passive magnetic shield was simulated, designed and installed to reduce the influence of the MRI magnet stray field on the electron beamline. The B field inside the shield was measured as a function of gantry angle and measurements of dose rate constancy upon gantry rotation were performed. Results: The magnitude of the magnetic field on the electron beam path without the shield was as high as 70G. It varied by up to 15G with gantry rotation due to the presence of metal beams in the bunker floor which resulted in dose output drop of up to 70% at certain gantry angles. With the prototype shield, field magnitude was reduced to well below 0.5G everywhere along the electron beam path. Field variation with gantry rotation was decreased to below 0.2G and enabled dose output of the linac to be recovered at all gantry angles. The homogeneity of the field inside the MRI magnet has not been compromised. Conclusion: It was demonstrated that the influence of the 1.5T magnet and the bunker design on the linac operation has been minimised. The performance will be further improved on the Elekta Atlantic system which incorporates a newly developed and optimised Philips magnet design and bunker construction. J Harasimowicz, D Roberts, I Shinton and S Sund are employed by Elekta Limited Crawley, H Wang and M Zhong are employed by Elekta Beijing Medical Systems Co. Ltd., J Overweg is employed by Philips Technologie GmbH Forschungslaboratorien.

60 APPLIED LIFE SCIENCES↗

Laser-driven ion and electron acceleration from near-critical density gas targets: Towards high-repetition rate operation in the 1 PW, sub-100 fs laser interaction regime

Ion acceleration from gaseous targets driven by relativistic-intensity lasers was demonstrated as early as the late 1990s, yet most of the experiments conducted to date have involved picosecond-duration, Nd:glass lasers operating at low repetition rate. Here, we present measurements on the interaction of ultraintense ( ≈ 10 20 W cm − 2 , 1 PW ) , ultrashort ( ≈ 70 fs ) Ti:Sa laser pulses with near-critical ( ≈ 10 20 cm − 3 ) helium gas jets, a debris-free targetry with the potential for future compatibility with high ( ≈ 1 Hz ) repetition rate operation. We provide evidence of α particles being forward accelerated up to ≈ 2.7 − MeV energy with a total flux of ≈ 10 11 sr − 1 as integrated over > 0.1 − MeV energies and detected within a 0.5 − mrad solid angle. We also report on on-axis emission of relativistic electrons with an exponentially decaying spectrum characterized by a ≈ 10 − MeV slope, i.e., five times larger than the standard ponderomotive scaling. The total charge of these electrons with energy above 2 MeV is estimated to be of ≈ 1 nC , corresponding to ≈ 0.1 % of the laser drive energy. In addition, we observe the formation of a plasma channel, extending longitudinally across the gas density maximum and expanding radially with time. These results are well captured by large-scale particle-in-cell simulations, which reveal that the detected fast ions most likely originate from reflection off the rapidly expanding channel walls. The latter process is predicted to yield ion energies in the MeV range, which compare well with the measurements. Finally, direct laser acceleration is shown to be the dominant mechanism behind the observed electron energization. Published by the American Physical Society 2024

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Infrastructure-scale additive manufacturing using mobile electron accelerators

A method and system for in situ cross-linking of polymers, Bitumen, and other materials to produce arbitrary functional or ornamental three-dimensional features using electron beams provided by mobile accelerators comprises defining a desired pattern for imparting on a target area, mapping the target area, defining at least one discrete voxel in the target area according to the desired pattern to be imparted on the target area, assigning an irradiation value to each of the at least one discrete voxels, and delivering a dose of irradiation to each of the at least one discrete voxels according to the assigned irradiation value.

Sauers, Aaron↗