Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electron Beam Collimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Gantry and isocenter displacements of a linear accelerator caused by an add-on micromultileaf collimator

Purpose: The delivery of high quality stereotactic radiosurgery (SRS) and stereotactic radiotherapy (SRT) treatments to the patient requires knowledge of the position of the isocenter to submillimeter accuracy. To meet the requirements the deviation between the radiation and mechanical isocenters must be less than 1 mm. The use of add-on micromultileaf collimators ({mu}MLCs) in SRS and SRT is an additional challenge to the anticipated high-level geometric and dosimetric accuracy of the treatment. The aim of this work was to quantify the gantry excursions during rotation with and without an add-on {mu}MLC attached to the gantry head. In addition, the shift in the position of the isocenter and its correlation to the kV beam center of the cone-beam CT system was included in the study. Methods: The quantification of the gantry rotational performance was done using a pointer supported by an in-house made rigid holder attached to the gantry head of the accelerator. The pointer positions were measured using a digital theodolite. To quantify the effect of an {mu}MLC of 50 kg, the measurements were repeated with the {mu}MLC attached to the gantry head. The displacement of the isocenter due to an add-on {mu}MLC of 50 kg was also investigated. In case of the pointer measurement the {mu}MLC was simulated by weights attached to the gantry head. A method of least squares was applied to determine the position and displacement of the mechanical isocenter. Additionally, the displacement of the radiation isocenter was measured using a ball-bearing phantom and the electronic portal image device system. These measurements were based on 8 MV photon beams irradiated onto the ball from the four cardinal angles and two opposed collimator angles. The measurements and analysis of the data were carried out automatically using software delivered by the manufacturer. Results: The displacement of the mechanical isocenter caused by a 50 kg heavy {mu}MLC was found to be (-0.01 {+-} 0.05, -0.10 {+-} 0.03, -0.26 {+-} 0.05) mm in lateral, longitudinal, and vertical direction, respectively. Similarly, the displacement of the radiation isocenter was found to be (0.00 {+-} 0.03, -0.08 {+-} 0.06, -0.32 {+-} 0.02) mm. Good agreement was found between the displacement of the two isocenters. A displacement of the kV cone-beam CT beam center due to the attached weight of 50 kg could not be detected. Conclusions: General characteristics of the gantry arm excursions and displacements caused by an add-on {mu}MLC have been reported. A 50 kg heavy add-on {mu}MLC results in a isocenter displacement downward of 0.26-0.32 mm. The authors recommend that the beam center of the kV cone-beam CT image system should be matched to the isocenter related to the weight of the {mu}MLC. Consequently, the imperfections in isocenter localizations are transferred to the conventional radiotherapy where the clinical consequences of uncertainties in the submillimeter regime are negligible.

60 APPLIED LIFE SCIENCES↗

Progress with Long-Range Beam-Beam Compensation Studies for High Luminosity LHC

Long-range beam-beam (LRBB) interactions can be a source of emittance growth and beam losses in the LHC during physics and will become even more relevant with the smaller '* and higher bunch intensities foreseen for the High Luminosity LHC upgrade (HL-LHC), in particular if operated without crab cavities. Both beam losses and emittance growth could be mitigated by compensat-ing the non-linear LRBB kick with a correctly placed current carrying wire. Such a compensation scheme is currently being studied in the LHC through a demonstration test using current-bearing wires embedded into col-limator jaws, installed either side of the high luminosity interaction regions. For HL-LHC two options are considered, a current-bearing wire as for the demonstrator, or electron lenses, as the ideal distance between the particle beam and compensating current may be too small to allow the use of solid materials. This paper reports on the ongoing activities for both options, covering the progress of the wire-in-jaw collimators, the foreseen LRBB experiments at the LHC, and first considerations for the design of the electron lenses to ultimately replace material wires for HL-LHC.

43 PARTICLE ACCELERATORS↗

Lidar instruments proposed for Eos

Lidar, an acronym for light detection and ranging, represents a class of instruments that utilize lasers to send probe beams into the atmosphere or onto the surface of the Earth and detect the backscattered return in order to measure properties of the atmosphere or surface. The associated technology has matured to the point where two lidar facilities, Geodynamics Laser Ranging System (GLRS), and Laser Atmospheric Wind Sensor (LAWS) were accepted for Phase 2 studies for Eos. A third lidar facility Laser Atmospheric Sounder and Altimeter (LASA), with the lidar experiment EAGLE (Eos Atmospheric Global Lidar Experiment) was proposed for Eos. The generic lidar system has a number of components. They include controlling electronics, laser transmitters, collimating optics, a receiving telescope, spectral filters, detectors, signal chain electronics, and a data system. Lidar systems that measure atmospheric constituents or meteorological parameters record the signal versus time as the beam propagates through the atmosphere. The backscatter arises from molecular (Rayleigh) and aerosol (Mie) scattering, while attenuation arises from molecular and aerosol scattering and absorption. Lidar systems that measure distance to the Earth's surface or retroreflectors in a ranging mode record signals with high temporal resolution over a short time period. The overall characteristics and measurements objectives of the three lidar systems proposed for Eos are given.

Grant, William B.↗

Comparison and uncertainty evaluation of different calibration protocols and ionization chambers for low-energy surface brachytherapy dosimetry

Purpose: A surface electronic brachytherapy (EBT) device is in fact an x-ray source collimated with specific applicators. Low-energy (<100 kVp) x-ray beam dosimetry faces several challenges that need to be addressed. A number of calibration protocols have been published for x-ray beam dosimetry. The media in which measurements are performed are the fundamental difference between them. The aim of this study was to evaluate the surface dose rate of a low-energy x-ray source with small field applicators using different calibration standards and different small-volume ionization chambers, comparing the values and uncertainties of each methodology. Methods: The surface dose rate of the EBT unit Esteya (Elekta Brachytherapy, The Netherlands), a 69.5 kVp x-ray source with applicators of 10, 15, 20, 25, and 30 mm diameter, was evaluated using the AAPM TG-61 (based on air kerma) and International Atomic Energy Agency (IAEA) TRS-398 (based on absorbed dose to water) dosimetry protocols for low-energy photon beams. A plane parallel T34013 ionization chamber (PTW Freiburg, Germany) calibrated in terms of both absorbed dose to water and air kerma was used to compare the two dosimetry protocols. Another PTW chamber of the same model was used to evaluate the reproducibility between these chambers. Measurements were also performed with two different Exradin A20 (Standard Imaging, Inc., Middleton, WI) chambers calibrated in terms of air kerma. Results: Differences between surface dose rates measured in air and in water using the T34013 chamber range from 1.6% to 3.3%. No field size dependence has been observed. Differences are below 3.7% when measurements with the A20 and the T34013 chambers calibrated in air are compared. Estimated uncertainty (with coverage factor k = 1) for the T34013 chamber calibrated in water is 2.2%–2.4%, whereas it increases to 2.5% and 2.7% for the A20 and T34013 chambers calibrated in air, respectively. The output factors, measured with the PTW chambers, differ by less than 1.1% for any applicator size when compared to the output factors that were measured with the A20 chamber. Conclusions: Measurements using both dosimetric protocols are consistent, once the overall uncertainties are considered. There is also consistency between measurements performed with both chambers calibrated in air. Both the T34013 and A20 chambers have negligible stem effect. Any x-ray surface brachytherapy system, including Esteya, can be characterized using either one of these calibration protocols and ionization chambers. Having less correction factors, lower uncertainty, and based on measurements, performed in closer to clinical conditions, the TRS-398 protocol seems to be the preferred option.

60 APPLIED LIFE SCIENCES↗

Phase I (Final Report)

The focus of this proposal was the development of a new instrument capable of in-situ, spatially resolved, measurement of the energy spectra of ions in the edge of a tokamak plasma. The energy spectra of the ions determines the rates of sputtering and erosion of the plasma facing surfaces. The ion spectra in the edge is not easily determined spectroscopically and must be measured in situ since the ions are confined by the strong magnetic fields of the tokamak. Conventional energy analyzers are too large and expensive to install in multiple locations around the tokamak torus. The probes to be developed in this project are compact, low cost, and small enough to be placed inside of specially prepared wall tiles – essentially creating a “smart” plasma facing surface in a tokamak. Phase 1 of this project successfully demonstrated that two key elements of the instrument, the collimator and the energy analyzer, could be fabricated on a single silicon wafer and the combination functioned as designed when tested with an electron beam.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

TWO-STREAM-LIKE INSTABILITY IN DILUTE HOT RELATIVISTIC BEAMS AND ASTROPHYSICAL RELATIVISTIC SHOCKS

Relativistic collisionless shocks are believed to be efficient particle accelerators. Nonlinear outcome of the interaction of accelerated particles that run ahead of the shock, the so-called precursor, with the unperturbed plasma of the shock upstream, is thought to facilitate additional acceleration of these particles and to possibly modify the hydrodynamic structure of the shock. We explore here the linear growth of kinetic modes appearing in the precursor-upstream interaction in relativistic shocks propagating in non- and weakly magnetized plasmas: electrostatic two-stream parallel mode and electrostatic oblique modes. The physics of the parallel and oblique modes is similar, and thus, we refer to the entire spectrum of electrostatic modes as 'two-stream-like'. These modes are of particular interest because they are the fastest growing modes known in this type of system. Using a simplified distribution function for a dilute ultrarelativistic beam that is relativistically hot in its own rest frame, yet has momenta that are narrowly collimated in the frame of the cold upstream plasma into which it propagates, we identify the fastest growing mode in the full k-space and calculate its growth rate. We consider all types of plasma (pairs and ions-electrons) and beam (charged and charge-neutral). We find that unstable electrostatic modes are present in any type of plasma and for any shock parameters. We further find that two modes, one parallel (k{sub perpendicular} = 0) and the other one oblique (k{sub perpendicular} {approx} k{sub ||}), are competing for dominance and that either one may dominate the growth rate in different regions of the phase space. The dominant mode is determined mostly by the perpendicular spread of the accelerated particle momenta in the upstream frame, which reflects the shock Lorentz factor. The parallel mode becomes more dominant in shocks with lower Lorentz factors (i.e., with larger momentum spreads). We briefly discuss possible implications of our results for external shocks in gamma-ray burst sources.

79 ASTRONOMY AND ASTROPHYSICS↗

Machine Protection Studies of Fast Instability-Driven Beam Losses in the EIC Electron Storage Ring

Fast transverse beam instabilities represent one of the most challenging protection scenarios for the Electron-Ion Collider (EIC) electron storage ring (ESR). Coherent betatron oscillations driven by collective effects can grow rapidly and lead to substantial beam losses within only a few tens of turns, posing a threat to collimators, superconducting (SC) magnets, cryogenic systems, and detector components. A dedicated simulation framework based on distributed transverse excitations was developed to evaluate instability-driven beam losses in the ESR. A conservative instability rise time on the order of 10 turns was used to define a bounding protection scenario. Simulations show that the original two-collimator configuration is insufficient to localize losses under all operating conditions, whereas an optimized four-collimator configuration reduces loss leakage into protected regions by more than two orders of magnitude. Nevertheless, the most severe instability scenarios produce catastrophic beam impacts, with nearly half of the stored beam being intercepted by the collimators within a single turn, exceeding the preliminary estimated survivability limits of the baseline collimator design. The results demonstrate that collimation alone is insufficient to guarantee safe ESR operation and must be complemented by a fast machine-protection system. Dedicated turn-by-turn beam-position monitors and fast beam-loss monitors provide sufficient advance warning to detect instability growth and initiate a beam abort before equipment-damaging loss levels are reached. These findings establish quantitative requirements for the ESR machine-protection architecture and support the implementation of a multilayer protection strategy for both accelerator and detector systems.

43 PARTICLE ACCELERATORS↗

Beamlet based direct aperture optimization for MERT using a photon MLC

Purpose: A beamlet based direct aperture optimization (DAO) for modulated electron radiotherapy (MERT) using photon multileaf collimator (pMLC) shaped electron fields is developed and investigated. Methods: The Swiss Monte Carlo Plan (SMCP) allows the calculation of dose distributions for pMLC shaped electron beams. SMCP is interfaced with the Eclipse TPS (Varian Medical Systems, Palo Alto, CA) which can thus be included into the inverse treatment planning process for MERT. This process starts with the import of a CT-scan into Eclipse, the contouring of the target and the organs at risk (OARs), and the choice of the initial electron beam directions. For each electron beam, the number of apertures, their energy, and initial shape are defined. Furthermore, the DAO requires dose–volume constraints for the structures contoured. In order to carry out the DAO efficiently, the initial electron beams are divided into a grid of beamlets. For each of those, the dose distribution is precalculated using a modified electron beam model, resulting in a dose list for each beamlet and energy. Then the DAO is carried out, leading to a set of optimal apertures and corresponding weights. These optimal apertures are now converted into pMLC shaped segments and the dose calculation for each segment is performed. For these dose distributions, a weight optimization process is launched in order to minimize the differences between the dose distribution using the optimal apertures and the pMLC segments. Finally, a deliverable dose distribution for the MERT plan is obtained and loaded back into Eclipse for evaluation. For an idealized water phantom geometry, a MERT treatment plan is created and compared to the plan obtained using a previously developed forward planning strategy. Further, MERT treatment plans for three clinical situations (breast, chest wall, and parotid metastasis of a squamous cell skin carcinoma) are created using the developed inverse planning strategy. The MERT plans are compared to clinical standard treatment plans using photon beams and the differences between the optimal and the deliverable dose distributions are determined. Results: For the idealized water phantom geometry, the inversely optimized MERT plan is able to obtain the same PTV coverage, but with an improved OAR sparing compared to the forwardly optimized plan. Regarding the right-sided breast case, the MERT plan is able to reduce the lung volume receiving more than 30% of the prescribed dose and the mean lung dose compared to the standard plan. However, the standard plan leads to a better homogeneity within the CTV. The results for the left-sided thorax wall are similar but also the dose to the heart is reduced comparing MERT to the standard treatment plan. For the parotid case, MERT leads to lower doses for almost all OARs but to a less homogeneous dose distribution for the PTV when compared to a standard plan. For all cases, the weight optimization successfully minimized the differences between the optimal and the deliverable dose distribution. Conclusions: A beamlet based DAO using multiple beam angles is implemented and successfully tested for an idealized water phantom geometry and clinical situations.

60 APPLIED LIFE SCIENCES↗

SU-E-T-59: Calculations of Collimator Scatter Factors (Sc) with and Without Custom-Made Build-Up Caps for CyberKnife

Purpose: To investigate the impact of custom-made build-up caps for a diode detector in robotic radiosurgery radiation fields with variable collimator (IRIS) for collimator scatter factor (Sc) calculation. Methods: An acrylic cap was custom-made to fit our SFD (IBA Dosimetry, Germany) diode detector. The cap has thickness of 5 cm, corresponding to a depth beyond electron contamination. IAEA phase space data was used for beam modeling and DOSRZnrc code was used to model the detector. The detector was positioned at 80 cm source-to-detector distance. Calculations were performed with the SFD, with and without the build-up cap, for clinical IRIS settings ranging from 7.5 to 60 mm. Results: The collimator scatter factors were calculated with and without 5 cm build-up cap. They were agreed within 3% difference except 15 mm cone. The Sc factor for 15 mm cone without buildup was 13.2% lower than that with buildup. Conclusion: Sc data is a critical component in advanced algorithms for treatment planning in order to calculate the dose accurately. After incorporating build-up cap, we discovered differences of up to 13.2 % in Sc factors in the SFD detector, when compared against in-air measurements without build-up caps.

07 ISOTOPE AND RADIATION SOURCES↗

An empirical model of collective electrostatic effects for laser-beam channeling in long-scale-length relativistic plasmas

This work investigates the capability of ultraintense lasers with irradiance from 10{sup 18} to 10{sup 21} W cm{sup -2} to produce highly energetic electron beams from a Gaussian focus in a low-density plasma. A simple particle simulation code including a physical model of collective electrostatic effects in relativistic plasmas has been developed. Without electrostatic fields, free electrons escape from the Gaussian focal region of a 10-ps petawatt laser pulse very quickly, well before the laser field reaches its maximum amplitude. However, it has been demonstrated that the electrostatic field generated by the electron flow is able to strongly modify the range and direction of the laser-generated MeV electrons by allowing trapped electrons to experience much higher laser-intensity peaks along their trajectories. This modeling predicts some collimation but not enough to meet the requirements of fast ignition.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser-driven proton acceleration using a conical nanobrush target

A conical nanobrush target is proposed to improve the total proton energy-conversion efficiency in proton beam acceleration and investigated by two-dimensional particle-in-cell (2D-PIC) simulations. Results indicate a significant enhancement of the number and energies of hot electrons through the target rear side of the conical nanobrush target. Compared with the plain target, the field increases several times. We observe enhancements of the average proton energy and total laser-proton energy conversion efficiency of 105%. This enhancement is attributed to both nanobrush and conical configurations. The proton beam is well collimated with a divergence angle less than 28{sup Degree-Sign }. The proposed target may serve as a new method for increasing laser to proton energy-conversion efficiency.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A treatment planning approach to spatially fractionated megavoltage grid therapy for bulky lung cancer

The purpose of this study was to explore the treatment planning methods of spatially fractionated megavoltage grid therapy for treating bulky lung tumors using multileaf collimator (MLC). A total of 5 patients with lung cancer who had gross tumor volumes ranging from 277 to 635 cm{sup 3} were retrospectively chosen for this study. The tumors were from 6.5 to 9.6 cm at shortest dimension. Several techniques using either electronic compensation or intensity-modulated radiation therapy (IMRT) were used to create a variety of grid therapy plans on the Eclipse treatment planning system. The dose prescription point was calculated to the volume, and a dose of 20 Gy with 6-MV/15-MV beams was used in each plan. The dose-volume histogram (DVH) curves were obtained to evaluate dosimetric characteristics. In addition, DVH curves from a commercially available cerrobend grid collimator were also used for comparison. The linear-quadratic radiobiological response model was used to assess therapeutic ratios (TRs) and equivalent uniform doses (EUD) for all generated plans. A total of 6 different grid therapy plans were created for each patient. Overall, 4 plans had different electronic compensation techniques: Ecomps-Tubes, Ecomps-Circles, Ecomps-Squares, and Ecomps-Weave; the other 2 plans used IMRT and IMRT-Weave techniques. The DVH curves and TRs demonstrated that these MLC-based grid therapy plans can achieve dosimetric properties very similar to those of the cerrobend grid collimator. However, the MLC-based plans have larger EUDs than those with the cerrobend grid collimator. In addition, the field shaping can be performed for targets of any shape in MLC-based plans. Thus, they can deliver a more conformal dose to the targets and spare normal structures better than the cerrobend grid collimator can. The plans generated by the MLC technique demonstrated the advantage over the standard cerrobend grid collimator on accommodating targets and sparing normal structures. Overall, 6 different plans showed 6 different dosimetric parameters. However, an optimal grid therapy plan selection from among these 6 types requires more information from clinical trials and radiobiological studies.

61 RADIATION PROTECTION AND DOSIMETRY↗

High transformer ratio drive beams for wakefield accelerator studies

For wakefield based acceleration schemes, use of an asymmetric (or linearly ramped) drive bunch current profile has been predicted to enhance the transformer ratio and generate large accelerating wakes. We discuss plans and initial results for producing such bunches using the 20 to 23 GeV electron beam at the FACET facility at SLAC National Accelerator Laboratory and sending them through plasmas and dielectric tubes to generate transformer ratios greater than 2 (the limit for symmetric bunches). The scheme proposed utilizes the final FACET chicane compressor and transverse collimation to shape the longitudinal phase space of the beam.

43 PARTICLE ACCELERATORS↗

Technical Report: Evaluation of peripheral dose for flattening filter free photon beams

Purpose: To develop a comprehensive peripheral dose (PD) dataset for the two unflattened beams of nominal energy 6 and 10 MV for use in clinical care. Methods: Measurements were made in a 40 × 120 × 20 cm{sup 3} (width × length × depth) stack of solid water using an ionization chamber at varying depths (dmax, 5, and 10 cm), field sizes (3 × 3 to 30 × 30 cm{sup 2}), and distances from the field edge (5–40 cm). The effects of the multileaf collimator (MLC) and collimator rotation were also evaluated for a 10 × 10 cm{sup 2} field. Using the same phantom geometry, the accuracy of the analytic anisotropic algorithm (AAA) and Acuros dose calculation algorithm was assessed and compared to the measured values. Results: The PDs for both the 6 flattening filter free (FFF) and 10 FFF photon beams were found to decrease with increasing distance from the radiation field edge and the decreasing field size. The measured PD was observed to be higher for the 6 FFF than for the 10 FFF for all field sizes and depths. The impact of collimator rotation was not found to be clinically significant when used in conjunction with MLCs. AAA and Acuros algorithms both underestimated the PD with average errors of −13.6% and −7.8%, respectively, for all field sizes and depths at distances of 5 and 10 cm from the field edge, but the average error was found to increase to nearly −69% at greater distances. Conclusions: Given the known inaccuracies of peripheral dose calculations, this comprehensive dataset can be used to estimate the out-of-field dose to regions of interest such as organs at risk, electronic implantable devices, and a fetus. While the impact of collimator rotation was not found to significantly decrease PD when used in conjunction with MLCs, results are expected to be machine model and beam energy dependent. It is not recommended to use a treatment planning system to estimate PD due to the underestimation of the out-of-field dose and the inability to calculate dose at extended distances due to the limits of the dose calculation matrix.

60 APPLIED LIFE SCIENCES↗

FLArE up dark sectors with EM form factors at the LHC forward physics facility

Despite being mostly secluded, dark sector particles may feebly interact with photons via a small mass-dimension 4 millicharge, a mass-dimension 5 magnetic and electric dipole moment, or a mass-dimension 6 anapole moment and charge radius. If sufficiently light, the LHC may produce an intense and collimated beam of these particles in the far forward direction. We study the prospects of searching for such dark sector particles with electromagnetic form factors via their electron scattering signature in the Forward Liquid Argon Experiment (FLArE) at the Forward Physics Facility (FPF). We find that FLArE can provide new probes of sub-GeV dark particles with dipole moments and strong sensitivities for millicharged particles in the 100 MeV to 100 GeV region. This complements other search strategies using scintillation signatures or dark matter direct detection and allows for probing strongly interacting dark matter motivated by the EDGES anomaly. Along with the FORMOSA detector, this leads to a very versatile and leading experimental program in the search for millicharged particles in the FPF.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Enhanced proton acceleration in an applied longitudinal magnetic field

Using two-dimensional particle-in-cell simulations, we examine how an externally applied strong magnetic field impacts proton acceleration in laser-irradiated solid-density targets. We find that a kT-level external magnetic field can sufficiently inhibit transverse transport of hot electrons in a flat laser-irradiated target. While the electron heating by the laser remains mostly unaffected, the reduced electron transport during proton acceleration leads to an enhancement of maximum proton energies and the overall number of energetic protons. The resulting proton beam is much better collimated compared to a beam generated without applying a kT-level magnetic field. A factor of three enhancement of the laser energy conversion efficiency into multi-MeV protons is another effect of the magnetic field. The required kT-level magnetic fields are becoming feasible due to a significant progress that has been made in generating magnetic fields with laser-driven coils using ns-long laser pulses. The possibility of improving characteristics of laser-driven proton beams using such fields is a strong motivation for further development of laser-driven magnetic field capabilities.

43 PARTICLE ACCELERATORS↗

Optimal Spatial Separation of High-Order Harmonics from Infrared Driving Lasers with an Annular Beam in the Overdriven Regime

We study high-order harmonic generation (HHG) with an annularly shaped high-power, high-repetition-rate laser. In this work we investigate how the spatial separation (or divergence) of the incident laser and the generated high-order harmonics depends on the gas pressure when the laser intensity is in the overdriven regime. It is shown that, when the cone size of the incident annular beam is relatively large, the resulting harmonics are highly collimated along the propagation axis and are spatially separated from the incident beam. Under the overdriven condition, dynamic phase matching favors HHG emissions from short-trajectory electrons that are efficiently built up in the second half of the gas medium. We verify that using an annular beam is a simple and effective method for separating the intense incident infrared laser from the generated high harmonics. Such high-flux and low-divergence light pulses are expected to be powerful sources in the laboratory for ultrafast probing of electron dynamics.

47 OTHER INSTRUMENTATION↗

Measurements of transverse beam halo diffusion rates in the LHC with collimator scans

Measurements of beam halo dynamics were conducted in the LHC on 22 June 2012 at 4 TeV using collimator scans. Four scans were performed: on proton beam 1 with a vertical collimator and on beam 2 with a horizontal collimator, first with squeezed separated beams and subsequently in collision. The time evolution of losses following collimator steps provides experimental estimates of halo diffusion, halo population, impact parameter distributions, and beam jitter. Besides its general interest for beam dynamics and machine performance characterization, this information forms an essential input for the general design of collimation systems, including new methods such as crystal collimators and hollow electron lenses. In this note, the results of an analysis of the data is presented.

43 PARTICLE ACCELERATORS↗