Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electron emission”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Electromagnetic Analysis of ITER Electron Cyclotron Emission Model

The ITER electron cyclotron emission (ECE) diagnostic system is located at diagnostics shielding module 2 (DSM2), equatorial port 9 (EP9), to measure electron temperature profile and electron temperature fluctuations, and also assess nonthermal electron distributions via the oblique view. Therefore, ECE has both radial and oblique views with two hot sources for calibration and two couples of mirrors for two different optical views. It shall receive that the large electromagnetic (EM) loads up to 100-MN/m3 force density due to the eddy currents on the copper mirrors generated by the short transient plasma disruption. The simplified EM analysis model using magnetic field ( B ) data and flux variations (dB/dt) method based on the worst case of plasma disruption, MD_DW_EXP16MS_CATIII, has been developed to calculate the force and moments for each ECE component and support structure for EP9 DSM2 Bay2 and Bay3. The B and dB/dt methods use the constant B and dB/dt assumed for each local bay space, but the real B and dB/dt are basically varied along the radial direction of each bay. The complex global model with the local ECE components and support structure using Maxwell transient has been developed to do EM analysis to compare the results of the B and dB/dt models. The volumetric EM force density of the whole ECE components and support structure can be used for the subsequent structural analysis. In conclusion, combined with the thermal and nuclear loads and seismic and initial loads, the ECE integration analysis can be finalized for the operation case.

Fang, J. [Princeton Plasma Physics Laboratory (PPP↗

Development of intelligent control module for the J-TEXT electron cyclotron emission imaging system

An Electron Cyclotron Emission Imaging (ECEI) system has been developed on the J-TEXT tokamak and employed for the multi-dimensional electron temperature fluctuation imaging measurement in 2019 campaign. The intelligent control module has been developed and been used to flexibly setup the 256-channel ECEI system configurations for different plasma scenarios. The adjustments of key parameters are merged in this module including size and position of the geometric observation window, and the dynamic range of the signal and image resolution. The user-friendly interface is also developed for the tokamak operator to set the ECEI system focusing on physics interested region. Furthermore, this module is installed close to the diagnostic system around the J-TEXT tokamak, which can be remotely controlled by authorized operators in the control room. It significantly improves ECEI flexibility and stability, and also keeps the operation technician away from the harsh radiation environment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optical design and synthetic analysis of the electron cyclotron emission imaging diagnostic of HL-2M tokamak

The electron cyclotron emission imaging (ECEI) diagnostic is a powerful tool to study the MHD and turbulent transport in magnetically confined fusion plasmas. In this work, the optical system including the local oscillator (LO) coupling and radio frequency (RF) receiving optics, has been designed and analyzed for the HL-2M ECEI diagnostic. The LO optics can illuminate the antenna array and drive the mixer diode to work efficiently, with more than 36% of the beam intensity for the channels which probe the plasma edge relative to those of channels which probe the plasma core. The RF optics aims at guiding the plasma emission signal to the antenna array. To meet different physical requirements, three types of field of view have been achieved for the plasma imaging, with zoom factors of around 1, 1.5 and 2, respectively. The focal surfaces are almost flat, with a maximum off-mapping (defined as the radial distance between the beam waists of the lower-/uppermost antennas and electron cyclotron emission layer) less than 2.5 cm, which can match the electron cyclotron emission layer quite well and suppress the image distortion in the plasma edge region. Furthermore, the impact of possible vibrations and installation error on the focal plane has been evaluated. In addition, the predefined MHD and turbulence perturbations are well reproduced by combining the optical simulation results and synthetic ECEI modeling, which further verifies the good performance of the RF optics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Method of synthesizing small-diameter carbon nanotubes with electron field emission properties

Carbon nanotube material having an outer diameter less than 10 nm and a number of walls less than ten are disclosed. Also disclosed are an electron field emission device including a substrate, an optionally layer of adhesion-promoting layer, and a layer of electron field emission material. The electron field emission material includes a carbon nanotube having a number of concentric graphene shells per tube of from two to ten, an outer diameter from 2 to 8 nm, and a nanotube length greater than 0.1 microns. One method to fabricate carbon nanotubes includes the steps of (a) producing a catalyst containing Fe and Mo supported on MgO powder, (b) using a mixture of hydrogen and carbon containing gas as precursors, and (c) heating the catalyst to a temperature above 950.degree. C. to produce a carbon nanotube. Another method of fabricating an electron field emission cathode includes the steps of (a) synthesizing electron field emission materials containing carbon nanotubes with a number of concentric graphene shells per tube from two to ten, an outer diameter of from 2 to 8 nm, and a length greater than 0.1 microns, (b) dispersing the electron field emission material in a suitable solvent, (c) depositing the electron field emission materials onto a substrate, and (d) annealing the substrate.

Liu, Jie↗

Electrostatic emissions between electron gyroharmonics in the outer magnetosphere

Electrostatic emissions are often observed by spacecraft in the outer magnetosphere at frequencies between low electron gyroharmonics. The emissions include the well-known odd half-harmonic emissions as well as weaker emissions which occur near the electron plasma frequency. A scheme is constructed for classifying the emissions, and it is shown that a theoretical model which has been previously used to explain '3/2' emissions can be extended to the other classes of emissions. All of the emissions therefore appear to be generated by the same basic mechanism: an unstable electron plasma distribution consisting of cold electrons (below 100 eV) and hot loss cone electrons (about 1 keV). Each emission class is associated with a particular range of model parameters; the wide-band electric field data can thus be used to infer the density and temperature of the cold plasma component. The model predicts that gyroharmonic emissions near the plasma frequency require large cold plasma densities.

Hubbard, R. F.↗

Electron Activity (Secondary Electron & Field Emission ) Suppression by Magnetic Field Placed on the Surface of Metals And Dielectric [Slides]

Secondary electron emission happens when the surface is exposed to an oscillating electromagnetic field. It has extremely dangerous effect when resonance condition of this oscillating field and higher SEY conditions are met. The dependence of the secondary electron on primary electron energy is shown in the figure. This multiplication effect on the number of electrons in oscillating electromagnetic field is called multipacting. The problem with multipacting exist in many scientific fields like LHC, ISS, ITER involving particle accelerator, space science and fusion research. In high intensity proton rings this multiplies electron get trapped inside the potential created by proton beam called electron cloud. In High power microwave sources, rf couplers and rf window to couple the power also hugely affected by multipacting.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ni 3 Si 2 nanowires for efficient electron field emission and limitations of the Fowler–Nordheim model

This article reports on top-down nanofabricated Ni 3 Si 2 nanowires and tests of their electron field emission capabilities. Here, the results include low turn-on electric field, E ON , moderate work function, Φ, and the field enhancement factor, β, customizable through nanofabrication. The article also reports on the issues ahead in the field of nanowires-based electron mission, as there are quantitative limitations of the applicability of the Fowler–Nordheim model, which will become increasingly apparent as we continue to optimize the field emission of electrons. To this end, we suggest adding the studies of surface-to-volume ratio effects of the nanowires as another standard for comparison in order to lead to the input form of the density of states as quantum effects becoming more prominent.

42 ENGINEERING↗

Electron cyclotron emission measurements and modeling in optically semi-transparent plasma on the HSX stellarator

On the Helically Symmetric Experiment (HSX), electron cyclotron emission (ECE) at the second harmonic of the electron gyrofrequency is measured with a 16-channel heterodyne receiver. An ECE radiometer diagnostic has been calibrated with a broadband frequency source, allowing independent measurements of the electron temperature. The antenna pattern has a significant impact on the measurements, and modeling its effect is necessary to produce an ECE radiation temperature spectrum. Measurements, calibration results, and modeling of the ECE data are presented in this paper. At a relatively high plasma density, HSX plasmas are thermal, and the radiation temperature measured by the radiometer is in good agreement with the electron temperature measured by a Thomson scattering diagnostic. At a relatively low plasma density, the deviation from a Maxwellian distribution is large, and asymmetry in the radiation temperature profile is measured. These measurements are supported by single-pass and multi-pass ray tracing calculations of the electron cyclotron emission using the TRAVIS ray tracing code. Thermal and nonthermal electron populations exist in HSX, and the effect of these populations on the asymmetry in the measured emission is presented.

Cyclotron radiation↗

Electromagnetic Analysis of ITER Electron Cyclotron Emission Components and Support Structures for the Preliminary Design Review

The ITER electron cyclotron emission (ECE) diagnostic system is located at Design Shield Module (DSM) 2, Equatorial Port (EP) 9 to measure electron temperature profile and electron temperature fluctuations and also to assess nonthermal electron distributions via the oblique view. Therefore, ECE has both radial and oblique views with two couples of mirrors for two different optical views. This ECE diagnostic system shall be exposed to significant power due to unabsorbed electron cyclotron heating power in the plasma. It shall also receive large electromagnetic (EM) loads up to 100 MN/m 3 force density due to the eddy currents generated by the short 16-ms transient plasma disruption. The global EM models of EP12 and EP11 with the worst case of plasma disruption Major Disruption Downward Exponential 16 ms Category III (MD_DW_EXP16MS_CATIII) have been provided by ITER. However, the support structure for these critical components, including four mirrors, is still under the design and development phase, especially during the period of preliminary design reviews (PDRs). For those small in-vessel components that are not modeled explicitly for the PDRs, we can extract the magnetic field (B) data and flux variations (dB/dt) at those locations from the global model and then use the B and dB/dt method to calculate the eddy currents, EM forces, and torques on those components in the local submodels. In conclusion, this paper will present the detailed PDR EM analysis results of the ECE components and support structures.

Electromagnetic↗

Electron Cyclotron Emission–Based Separatrix Identification in ITER with OMFIT Synthetic Modeling

Accurate determination of the separatrix location is essential for understanding edge plasma behavior and optimizing confinement in tokamaks, especially in next-generation devices such as ITER. In this study, a synthetic microwave diagnostics module was developed and implemented in the OMFIT framework to assess the feasibility of an electron cyclotron emission–based separatrix detection method in ITER plasmas. Simulations were carried out using ITER H-mode equilibrium scenarios with different plasma density profiles and different pedestal widths. Here, the results show that the electron emission temperature profiles consistently exhibit an inversion pattern near the edge, with a well-defined minimum point that could serve as a proxy for the separatrix location. However, unlike in the DIII-D, the minimum point in ITER is systematically offset by approximately 2 cm into the scrape-off layer, independent of density or pedestal width, which is within the radial resolution range (2 to 5 cm) determined by the 500-MHz channel spacing. While the method does not provide the exact separatrix location, it offers a reliable indicator of the boundary region and has potential applications for real-time boundary monitoring in ITER and other future fusion devices.

Electron cyclotron emission↗

Secondary Electron Suppression with Carbonized Aerogels

The goal addressed by this project is reduced DC power for high data rate RF communications by increasing the efficiency of traveling Wave Tubes (TWT) for RF communication, which are used by most space missions for communication and radio science at microwave frequencies. The capability needed is a robust electron collector surface with a secondary electron emission lower than ordinary graphite, which is the state of the art. While it is known that replacing a smooth surface with a textured one will reduce secondary electron emission, no robust textured surface is known. Carbonized polyimide aerogels promise the necessary robustness along with reduced secondary electron emission, allowing further improvement of TWT efficiency, achieving a very good return on the low investment made. Aerogels are known to be robust materials, and carbon aerogels are expected to have low secondary electron emission because of their open surface structure. The objective of this proposal is to demonstrate the low secondary electron emission of carbon aerogels and their robustness.

Secondary electron sippression↗

Fast modulating electron cyclotron emission (FMECE) diagnostic for tokamaks

Utilizing variable-frequency channels, e.g., yttrium iron garnet (YIG) bandpass filters, in the intermediate frequency (IF) section of an electron cyclotron emission (ECE) radiometer facilitates flexibility in the volume viewed by the ECE channels as well as high resolution electron temperature and temperature fluctuation measurements in tokamaks. Fast modulating electron cyclotron emission (FMECE), a stand-alone IF section with eight channels, is a novel application of YIG filters for real-time electron temperature gradient and gradient scale length measurements. Key to FMECE is a simultaneous input/output data acquisition unit, as well as a modified type of YIG filters, which is capable of fast switching of their center (set) frequencies with a frequency slew rate of 600 μs/GHz. A new FMECE has been implemented and tested on the DIII-D tokamak, demonstrating its capability in real-time gradient measurements. Here, the data presented here shows that FMECE can identify flattening in the electron temperature profile; the latter can be used as a sensor for real time monitoring and control of plasma instabilities. Implementation and application are planned for the EAST tokamak.

47 OTHER INSTRUMENTATION↗

Integrated package of electron cyclotron emission imaging data processing and forward modeling in OMFIT

An Electron Cyclotron Emission Imaging (ECEI) data analysis module has been developed for the OMFIT platform to accommodate the needs of users at the DIII-D tokamak for physics applications. The user can easily access the ECEI spatial observation windows in the plasma that are calculated based on the automatically retrieved hardware setup and available DIII-D equilibria, perform spectral analysis, and make 2D electron temperature fluctuation images. The module provides a powerful data post processing package for extracting important physics parameters from the 2D measurements, including the radial structure and poloidal mode number of Alfven Eigenmodes, as well as the frequency-vs-wavenumber dispersion relationship of broadband MHD. Lastly, the module propagates characterized synthetic fluctuations for the user, so one can perform forward modeling tasks with simple analytical fluctuations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reconstruction of magnetic island electron temperature in mixed second and third harmonic electron cyclotron emission conditions

Here we develop a method to use the mixed third and second harmonic electron cyclotron emission (ECE) signal in the DIII-D tokamak to reconstruct the electron temperature profile of a rotating magnetic island. The third harmonic ECE is removed by extracting the rotating-island-associated fluctuations in the mixed signal, and the extracted fluctuation is combined with the equilibrium temperature obtained from other diagnostics after correcting for the third harmonic reabsorption. The accuracy of the reconstruction is studied by considering a DIII-D shot where an unmixed signal from an island is available on the low field side of the plasma and a mixed signal from the same island is available from the high field side. It is found that the reconstruction method successfully reproduces the island shape and temperature perturbation magnitude without the distortion caused by third harmonic ECE mixing. However, the radial location of the reconstructed island is somewhat displaced relative to the location of the q = 2 surface in the axisymmetric equilibrium reconstruction, resulting in a corresponding inaccuracy in the absolute temperature of the island. It is conjectured that this may arise from an inaccuracy of the reconstructed axisymmetric equilibrium in this region.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling the Low-Pressure High-Voltage Branch of the Paschen Curve for Hydrogen and Deuterium

A physical and numerical model of the Townsend discharge in molecular hydrogen and deuterium has been developed to meet the needs of designing a plasma-based switching device for power grid applications. Here, the model allows to predict the low-pressure branch of the Paschen curve for applied voltage in the range of several hundred kilovolts. In the regime of interest, electrons are in a runaway state and ionization by ions and fast neutrals sustains the discharge. It was essential to correctly account for both gas-phase and surface interactions (electron emission and electron backscattering), especially in terms of their dependence on particle energy. The model yields results consistent with prior data obtained for lower voltage. The three-species (electrons, ions, and fast neutrals) model successfully captures the essential physics of the process.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗