Search NASA⌕ Search

SEARCH · Search NASA

Results for “Energy Modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Demand Response in Residential Energy Code: Technical Brief

As buildings account for over 75% of U.S. electricity use, effectively managing their loads can greatly facilitate the transition towards a clean, reliable grid. Grid-interactive efficient buildings (GEBs) combine efficiency and demand flexibility with smart technologies and communication to provide occupant comfort and productivity while serving the grid as a distributed energy resource (DER). In turn, GEBs can play a key role in ensuring access to an affordable, reliable, sustainable, and modern U.S. electric power system. Their national adoption could provide $\$$100-200 billion in U.S. electric power system cost savings over the next two decades. The associated reduction in CO 2 emissions is estimated at 6% per year by 2030 (DOE 2021). Building codes represent standard design practice in the construction industry and continually evolve to include advanced technologies and innovative practices. Historically, national model energy codes establish minimum efficiency requirements for new construction (ICC 2020). Expanding codes to support GEB capabilities is a pivotal step towards realizing demand flexibility in support of a clean grid by addressing capabilities to improve interoperability between smart building systems, the grid, and renewable energy resources. Realizing GEBs requires buildings with automated demand response (DR) capabilities that enable standardized communication with or control of, subject to explicit consumer consent, energy smart appliances or home energy management systems. This is achieved through direct or indirect (i.e., via an aggregator) communication between appliances and the electric grid. Energy codes can also support DR communication standardization and advance the deployment of building-integrated DERs such as energy storage, generation, and electric vehicles (EVs). Incorporating automated DR capabilities in energy codes provides many benefits to the consumers. Specifically, it aligns building electric load demand with intermittent renewable energy source availability, decreases peak load on the electric grid, allows buildings to respond to utility price signals, supports electrical network reliability and market growth of products and processes aligned with clean economic growth. The incorporation of DR into the model residential energy codes was considered for both the 2021 and 2024 International Energy Conservation Code (IECC) code development cycles. The approved DR measures in the 2021 cycle were removed in response to appeals (ICC 2020). Updated language was presented for consideration again for the 2024 IECC, where it was negotiated and again approved, and again removed in response to appeals (ICC 2024). This resulted in many sections, including sections on demand responsive controls, being moved to the credits options or an appendix as a voluntary application. This technical brief updates the proposed DR components such that they can be considered by states and local governments for direct incorporation into their codes, as well as for future IECC energy code development. The proposal refinements are intended to support consistency in approach and provide a degree of certainty for building owners, designers, contractors, manufacturers, and building and fire safety professionals. The scope of this technical brief includes three strategies for DR in residential buildings: 1) smart thermostats with demand-responsive control, 2) electric water heating incorporating demand-responsive controls and communication and 3) grid Integrated solar and energy storage systems.

2021 IECC↗

PolyA Single Strand DNA Translocation Through an Alpha-Hemolysin Pore Stem

A new model for the polymer-pore interaction energy is introduced, based on an atomic-scale description of coulombic polymer-pore interaction. The enhanced drift velocity, experimentally observed for short polymers, is successfully accounted for, using this interaction energy model. For R/R(sub 0)>4 (R(sub 0)=7 angstroms) the translocation velocity approaches the free space drift velocity v(sub 0). This motivates the need to appropriately derivatize artificial nanopores, where R>R(sub 0).

OKeeffe, James↗

A new database of building-space-specific internal loads and load schedules for performance based code compliance modeling of commercial buildings

Building-level loads and load profiles prescribed by current modeling rules save modelers time and avoid gaming during whole building performance modeling. However, recent studies show that they sometimes insufficiently capture the entire building performance due to the varied loads and load profiles for different space types. As a solution to this issue, this paper develops a database of building-space-specific loads and load profiles used in code compliance modeling. The existing sets of loads and load profiles are reviewed and the challenges behind using them for specific research topics are discussed. Then, the proposed method to develop the building-space-specific loads and load profiles is introduced. After that, the database for these building-space-specific loads and load profiles is presented. In addition, one case is studied to demonstrate the applications of these loads and load profiles. In this case study, three methods are used to develop building energy models: space-specific (using knowledge of the distribution and location of space types and applying the space-specific data in the developed database), building-level (assuming a lack of knowledge of the space types and using the building-level data in the developed database), and calculated-ratio (assuming knowledge of the distribution of space types but not their locations and calculating weighted average values based on the space-specific data in the developed database). Finally, the energy results simulated by using these three methods are compared, which show building-level methods can produce energy results up to 20% different than the space-specific methods. Finally, this paper discusses the application scope and maintenance of this new database.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Steady-state solutions of a diffusive energy-balance climate model and their stability

A diffusive energy-balance climate model, governed by a nonlinear parabolic partial differential equation, was studied. Three positive steady-state solutions of this equation are found; they correspond to three possible climates of our planet: an interglacial (nearly identical to the present climate), a glacial, and a completely ice-covered earth. Models similar to the main one are considered, and the number of their steady states was determined. All the models have albedo continuously varying with latitude and temperature, and entirely diffusive horizontal heat transfer. The stability under small perturbations of the main model's climates was investigated. A stability criterion is derived, and its application shows that the present climate and the deep freeze are stable, whereas the model's glacial is unstable. The dependence was examined of the number of steady states and of their stability on the average solar radiation.

Ghil, M.↗

Energy-balance climate models

An introductory survey of the global energy balance climate models is presented with an emphasis on analytical results. A sequence of increasingly complicated models involving ice cap and radiative feedback processes are solved and the solutions and parameter sensitivities are studied. The model parameterizations are examined critically in light of many current uncertainties. A simple seasonal model is used to study the effects of changes in orbital elements on the temperature field. A linear stability theorem and a complete nonlinear stability analysis for the models are developed. Analytical solutions are also obtained for the linearized models driven by stochastic forcing elements. In this context the relation between natural fluctuation statistics and climate sensitivity is stressed.

North, G. R.↗

Energy balance climate models

An introductory survey of the global energy balance climate models is presented with an emphasis on analytical results. A sequence of increasingly complicated models involving ice cap and radiative feedback processes are solved, and the solutions and parameter sensitivities are studied. The model parameterizations are examined critically in light of many current uncertainties. A simple seasonal model is used to study the effects of changes in orbital elements on the temperature field. A linear stability theorem and a complete nonlinear stability analysis for the models are developed. Analytical solutions are also obtained for the linearized models driven by stochastic forcing elements. In this context the relation between natural fluctuation statistics and climate sensitivity is stressed.

North, G. R.↗

22” ADP Fan Rig Liners Design Report

A liner design study was conducted as part of a cooperative effort between five (5) government/industry teams that together seek to demonstrate the technology for designing and manufacturing acoustic liners that are twenty five percent (25%) more efficient than 1992 technology liners. The study emphasized teaming collaboration. The improved liners were designed by Pratt & Whitney and Boeing Airplane Company and built by Rohr Inc, and will be tested in the NASA/P& W 22-inch ADP fan rig at NASA Lewis Research Center's 9' x 15' wind tunnel. Design guidelines and decisions were made collectively during monthly design review telecons and at the formal final design review. The tools that were used to design the new improved liners were not new, but the process that was developed as part of this study that led into the evaluation and selection of the final and best liner designs is new. Until now, the liner design process as practiced by different industry teams varied greatly. Some procedures were based on empirical liner attenuation databases which could not adequately account for engine-to-engine hardwall fan noise spectral differences, while others were entirely theoretical. And regardless of which method one chose, the major difficulty was still the lack of understanding and knowledge of the actual hardwall fan source noise modal structure and farfield SPL spectra. The NASA-led effort to attempt actual measurements of the fan source noise modal structure by means of the rotating microphone array is expected to contribute significantly to the understanding of the nature of the fan tone noise modes, but the application to broadband noise is still a long way off. The new design process included consideration of the measured fan tone modes, but for the majority of the spectra a separate, systematic process was used. It is a common practice in the engine/nacelle industry that acoustic liners for new products are designed before actual measured hardwall engine far-field noise spectra are available. Target noise spectra are normally derived from existing engine noise databases with some adjustments to absolute SPLs and frequencies. This practice has been acceptable as long as the new engine was a derivative of the base engine. However, in the case of the ADP, the transition from a current engine base is too - great, and the adjustments could not adequately account for the quantum changes in SPL spectral differences. Examples were the 1992 single degree of freedom (SDOF) inlet and aft liners (designed by P&W) that would be used as the baseline liners against which the new improved liners' efficien¬cies would -be measured. As will be shown, these baseline liners have been found to be deeper than the desire optimum depths. The new liner design process begins with the selection of the target hard wall fan noise spectra. These spectra were obtained by scaling up (5.91 scale factor) the measured hardwall fan spectral data from the 22” ADP fan rig. Next, the modal energy contents for each 1/3-octave band center frequency of these hardwall fan noise spectra are estimated. (Within each 1/3-octave band center frequency, the model energy distribution approximation is for both tone and broadband noise). For the inlet noise, P&W uses a derivative of the NASA Lewis (Ed Rice's) method of classifying; and grouping propagating modes by their cutoff ratios. The next step is to assign energy level to each group of modes having the same cutoff ratio. In Ed Rice's model, the modes were grouped according to ten (10) cutoff ratio intervals with center values located at 1.026, 1.085, 1.155, 1.24, 1.35, 1.49, 1.69, 2.0, and 4.47 (with equal number of modes in each interval). The modes were assumed to have equal energy. P&W’s model expands the cutoff ratio-mode grouping into two hundred (200) smaller cutoff ratio intervals with center values located f1".'m 1.003 to 11.5 in 199 increasing incremental intervals. Next, P&W's model uses a "2-parameter" normal distribution as a template to assign energy levels to these 200 pre-determined cutoff ratio values (for each 1/3-octave band center frequency). In the past, P&W had conducted an extensive study to determine what "2-parameter" values are appropriate for fullscale inlet liners, and had developed a set of twenty-four (24) "2-pararneter" values (i.e. one for each 1/3-octave frequency band) that when used in Ed Rice's Inlet Attenuation Prediction Method produced predicted liner attenuations that closely matched measured liner attenuations from several P&W's engines. In the absence of actual measured tone and broadband modal data from the 22" ADP rig, the process will use P&W's proprietary set of "2-parameter" values for this liner design study. For the aft noise, Boeing uses a modal energy approximation that the "transport energy" of each propagating mode is equal. This approximation is almost the same as the equal energy per mode approximation, except for modes that are near cutoff. Boeing's model forces these modes to have lower energy levels. Both P&W and Boeing agreed that the "transport energy" approximation should work well for the ADP aft fan noise which appears to be dominated by broadband noise. The design process then proceeds to calculate the optimum liner impedances for each frequency in both the inlet and the aft. These optimum impedances represent the target impedances that the designed liners should have. Liners with impedances matching the optimum impedances at all frequencies are "ideal" liners. These ideal liners are theoretically the best liners. Unfortunately, it has been showed that it is impossible to design and build such ideal liners. The next best liners are ones that have impedances matching the optimum impedances over some frequency range (not all frequencies as for the ideal). This is accomplished by the use of "frequency weightings". Several of P&W's and Boeing's existing computer decks were used for optimizing and matching the designed liner impedances to the target optimum values (with the various frequency weightings specified). The optimization produces liner candidates with predicted liner impedances and descriptions of their physical liner characteristics. These candidate liner impedances are then used to predict their spectral attenuation characteristics which are then used together with the target hardwall fan noise spectra to determine the resulting treated noise spectra and PNLT values. Further optimization around the selected candidate designs yield final designs that are best in PNLT attenuations. Use of the optimization decks allowed a large number of liner candidates to be screened in a relatively short period of time. This design process is systematic and is efficient. The new inlet SDOF liner design obtained from the improved process was predicted to be 34% more effective (per unit area) than the 1992 baseline inlet liner. This inlet liner design is a 112 rayl wovenwiremesh facesheet over a 0.312-inch deep honeycomb core. The new aft SDOF liner design was predicted to be 52% more efficient than the aft baseline liner. The new aft SDOF liner is "segmented" with a shallower liner on the core cowl (inner duct wall) and a deeper liner on the fan cowl (outer duct wall). The shallower liner is a 70.6 rayl woven-wiremesh facesheet over a 0.141-inch deep honeycomb core. The deeper liner is a 68 rayl woven-wiremesh facesheet over a 0.309-inch deep honeycomb core. All liner dimensions are for the 22-inch model-scale ADP fan rig liners. The selected advanced liners are "segmented" double-layer (DDOF) liners for the inlet and aft locations. Also, for the inlet, a bulk liner with ceramic foam for wider broadband noise absorption was also selected. Triple-layer liner designs were not considered since the model scaled liners ( 1/5. 91) were dimensionally too small to be built correctly, and irrin earlier concept study, Boeing found a triple-layer to have only very small benefits over a double-layer. The inlet DDOF liner was predicted to be 83% more effective than the baseline. The inlet DDOF design is a 78 rayl facesheet over a 0.080 top cavity depth, a 68 rayl septum and a 0.227-inch bottom cavity depth. The inlet bulk liner is a 60 rayl facesheet over a 0.33-inch deep honeycomb filled with high temperature (HTP) ceramic foam with a density of 4.8 lb/cu.ft and a flow resistivity of 167 rayl/cm. The inlet bulk liner was predicted to be 83% more effective than the baseline liner. The aft DDOF liners are segmented with a shallower liner on the core cowl and a deeper liner on the fan cowl. The shallow DDOF liner is a 49.8 rayl facesheet over a 0.093-inch top cavity depth, a septum of 88.2 rayls over a 0.181-inch bottom cavity depth. The deep DDOF liner is a 12.9 rayl facesheet over a 0.140-inch top cavity depth, a septum of 53.1 ray ls over a 0.258-inch botom cavity depth. The segmented aft DDOF liners were predicted to be 86% more efficient than the baseline liner.

turbofan acoustic treatment↗

EnergyPlus Model Context Protocol Server (EnergyPlus-MCP) v0.1

EnergyPlus-MCP is the first open-source Model Context Protocol server specifically designed for EnergyPlus building energy simulation. This innovative software enables AI assistants and other applications to interact programmatically with EnergyPlus through a standardized, secure interface, eliminating traditional technical barriers in building energy modeling. The software provides specialized tools across five functional domains: server management, model configuration and loading, comprehensive building component inspection, systematic model modification, and simulation execution with results visualization. Key features include automated HVAC system discovery and topology mapping, advanced schedule analysis, intelligent model validation, and interactive visualization capabilities. EnergyPlus-MCP's layered architecture ensures robust separation between protocol communication and domain expertise, enabling scalable deployment across organizations, educational institutions, and research teams. Unlike direct LLM approaches that suffer from inconsistent results and security gaps, EnergyPlus-MCP provides validated, reliable interactions while maintaining scientific rigor. This democratizes sophisticated building energy analysis, making EnergyPlus accessible to broader audiences through conversational interfaces and streamlined workflows.

Li, Han [Lawrence Berkeley National Laboratory (LB↗

Nonequilibrium radiation and chemistry models for aerocapture vehicle flowfields

The primary accomplishments of the project were as follows: (1) From an overall standpoint, the primary accomplishment of this research was the development of a complete gasdynamic-radiatively coupled nonequilibrium viscous shock layer solution method for axisymmetric blunt bodies. This method can be used for rapid engineering modeling of nonequilibrium re-entry flowfields over a wide range of conditions. (2) Another significant accomplishment was the development of an air radiation model that included local thermodynamic nonequilibrium (LTNE) phenomena. (3) As part of this research, three electron-electronic energy models were developed. The first was a quasi-equilibrium electron (QEE) model which determined an effective free electron temperature and assumed that the electronic states were in equilibrium with the free electrons. The second was a quasi-equilibrium electron-electronic (QEEE) model which computed an effective electron-electronic temperature. The third model was a full electron-electronic (FEE) differential equation model which included convective, collisional, viscous, conductive, vibrational coupling, and chemical effects on electron-electronic energy. (4) Since vibration-dissociation coupling phenomena as well as vibrational thermal nonequilibrium phenomena are important in the nonequilibrium zone behind a shock front, a vibrational energy and vibration-dissociation coupling model was developed and included in the flowfield model. This model was a modified coupled vibrational dissociation vibrational (MCVDV) model and also included electron-vibrational coupling. (5) Another accomplishment of the project was the usage of the developed models to investigate radiative heating. (6) A multi-component diffusion model which properly models the multi-component nature of diffusion in complex gas mixtures such as air, was developed and incorporated into the blunt body model. (7) A model was developed to predict the magnitude and characteristics of the shock wave precursor ahead of vehicles entering the Earth's atmosphere. (8) Since considerable data exists for radiating nonequilibrium flow behind normal shock waves, a normal shock wave version of the blunt body code was developed. (9) By comparing predictions from the models and codes with available normal shock data and the flight data of Fire II, it is believed that the developed flowfield and nonequilibrium radiation models have been essentially validated for engineering applications.

Carlson, Leland A.↗

OCHRE

OCHRE™ uses a variety of input data sources to run time-series simulations. Building models can be taken from the ResStock™ database or generated using the Building Energy Optimization Tool (BEopt™) or other OpenStudio-HPXML workflows. EV charging profiles can be taken from datasets used in NLR's 2030 National Charging Network project. Weather data can be taken from the National Solar Radiation Database or EnergyPlus® weather files. There are no public datasets with OCHRE outputs at this time. However, a recent project dataset on water heater and EV demand flexibility can be requested. OCHRE is a Python-based energy modeling tool designed to model flexible loads in residential buildings. OCHRE includes detailed models and controls for flexible devices including HVAC equipment, water heaters, EVs, solar PV, and batteries. It is designed to run in co-simulation with custom controllers, aggregators, and grid models.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Flexible Integration of Diverse HVAC Technologies in EnergyPlus via Python-Enabled Workflows

Analysis of advanced controls and novel system types is often not directly feasible in building energy simulation tools. Various techniques extend building energy simulation tool capabilities to allow the use of user-defined scripts and programs, but these approaches have limitations. The EnergyPlus Python plugin offers users new flexibility to use EnergyPlus to call an external Python module at specific points in the simulation, as well as to use Python to call EnergyPlus functionality through an application programming interface (API). This paper presents four case studies leveraging the EnergyPlus Python plugin to facilitate analysis of advanced controls and system types. The use of the Python plugin offers greater modularity and flexibility relative to previous approaches, is less error prone, and is simpler for users to adopt. The Python plugin allows EnergyPlus to be used in a more flexible manner and to accommodate the expanding realm of energy modeling applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building Performance Standards and Energy Code Alignment - Technical Brief

Building energy codes focus on building design, construction and renovation and have significantly increased building efficiency since the first national energy code was published in 1975. Most jurisdictions have energy codes based on ANSI/ASHRAE/IES Standard 90.1 (hereto referred to as Standard 90.1) and the International Energy Conservation Code (IECC). Compliance options available in these model energy codes include a prescriptive path, whole building performance paths – including IECC Total Building Performance (TBP), Standard 90.1 Energy Cost Budget (ECB) method and Performance Rating Method (PRM) – and system performance paths for envelope and heating, ventilation, and air-conditioning systems. Building performance standard (BPS) policies are an emerging policy tool used by jurisdictions to reduce the operational energy use or greenhouse gas (GHG) emissions of the existing commercial building stock. BPS policies vary widely between jurisdictions and are tailored to each location’s climate and energy goals. Intuitively, projects that met a recent edition of the energy code should comply with the BPS targets. However, some new buildings may struggle with meeting the BPS for the following reasons: 1. Energy codes focus on the design of the building and its projected ability to perform efficiently, while BPS compliance is dependent on the actual ongoing performance of the building, considering variables like occupancy, operation, and maintenance. 2. There are significant differences in the methodologies used to determine BPS compliance versus code compliance, including how each handles compliance metrics, handling of building amenities, and renewable energy generation. 3. The prescriptive compliance path in the energy code is based on performance of individual building components, as opposed to the performance compliance path which accounts for holistic building design strategies and interdependent building systems. This can result in a significant variability in post-occupancy performance for buildings built using the prescriptive path. Designs on the lower end of the permitted efficiency range may struggle with meeting the BPS.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Workshop Report: Rural Electric Cooperative Distributed Energy Resource Business Model Development Workshops

The United States' energy future is being shaped by decades of technology innovation, rapidly changing consumer requirements, and governmental focus on securing reliable, low-cost energy sources. With expanded electrification and increased emphasis on grid reliability coupled with the heightened complexity and risks associated with transmission infrastructure, the use of distributed energy resources (DERs) is more commonly being considered a safe, efficient, and cost-effective way to maintain grid resilience and reliability. Amidst improvements in performance, decreasing costs, and unprecedented federal policy support for DERs, electric cooperatives are considering new opportunities to use these assets to ensure secure and reliable operations for millions of customers. In light of these developments, a series of workshops were held to collaborate on the development of business models for DERs in rural electric cooperative ecosystems. The first workshop was held July 11, 2024, at the Tri-State Generation and Transmission Association Inc. headquarters in Westminster, Colorado (hereafter referred to as the "Tri-State Workshop"). The second workshop was hosted by PNGC Power on Oct. 9, 2024, in Portland, Oregon (hereafter referred to as the "PNGC Power Workshop"). These workshops convened representatives from G&Ts, distribution cooperatives,2 the energy industry, the financial community, the U.S. government, national and regional organizations, and national laboratories to share perspectives on the unique needs, challenges, and opportunities that they face as DERs are further integrated into the grid. The workshops were designed to address the following objectives: (1) develop the enabling attributes of electric cooperative DER business models, (2) explore pathways for generating community benefits from these assets, and (3) identify technical challenges and market risks for DERs in rural electric cooperative service territories. This report outlines key findings and major themes identified by workshop participants that federal agencies, G&Ts, distribution cooperatives, and other entities can consider to advance electric cooperative DER business models.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An expanded system simulation model for solar energy storage (technical report), volume 1

The simulation model for wind energy storage (SIMWEST) program now includes wind and/or photovoltaic systems utilizing any combination of five types of storage (pumped hydro, battery, thermal, flywheel and pneumatic) and is available for the UNIVAC 1100 series and the CDC 6000 series computers. The level of detail is consistent with a role of evaluating the economic feasibility as well as the general performance of wind and/or photovoltaic energy systems. The software package consists of two basic programs and a library of system, environmental, and load components. The first program is a precompiler which generates computer models (in FORTRAN) of complex wind and/or photovoltaic source/storage/application systems, from user specifications using the respective library components. The second program provides the techno-economic system analysis with the respective I/0, the integration of system dynamics, and the iteration for conveyance of variables.

Warren, A. W.↗

Electrification Analysis: Container Ports' Cargo Handling Equipment

This one-page highlight details the key takeaways from a project that utilized NREL's Fleet Research, Energy Data, and Insights (FleetREDI) data analysis pipeline, the Electrification Analysis of Container Ports' Cargo Handling Equipment project. This project created a scalable solution to model energy demand per shipping container moved (kWh/TEU) for an all-electric cargo handling equipment fleet located at a maritime port. The model allows stakeholders to understand energy demand at each electric vehicle (EV) equipment level and is easily scalable to container demand and EV adoption rate projections.

ADVANCED PROPULSION SYSTEMS↗