Search NASA⌕ Search

SEARCH · Search NASA

Results for “Equipment Assessment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Cybersecurity Platform and Certification Framework Development for Extreme Fast Charging (XFC)-Integrated Charging Ecosystem (Final Project Report)

This report summarizes a pioneering effort in Electric Vehicle charging infrastructure ecosystem cybersecurity requirements, assessment methodologies, functional verification, as well as embodiment of the key technologies in the form of hardware and software tools being made available to the public. EPRI led a team of experts, as well as a stakeholder coalition encompassing all key actors in the EV charging infrastructure ecosystem that includes eXtreme Fast Charging (XFC) equipment (defined as 200kW or above). EV charging infrastructure in the United States is a patchwork of networks that have continued to grow organically and have been designed to serve the charging needs of the EV owners, who are their customers. In doing so, each network provider, as well as their connected entities such as the cloud Electric Vehicle Service Providers or EVSPs, utility back office, utility AMI networks, payment networks, as well as Original Equipment Manufacturer (EV manufacturer) telematics networks, have designed systems that may work well individually, but no single entity is responsible for the entire ecosystem to be secure in terms of data exchange. Furthermore, there is no uniformity in how each actor has implemented the cybersecurity requirements since no system-wide cybersecurity requirements existed prior to this project. The final project report describes the technical approach guided by the EV charging infrastructure cybersecurity working group, convened specifically for this project. The technical approach included definition of requirements at the ecosystem level, treated as a ‘system of systems’, and then passed down to individual systems (EVSE, EV, cloud EVSP, utility, and the payment networks), followed by developing the cybersecurity risk and vulnerability assessment methods, that were later applied to real-world cyber-physical systems at EPRI, ANL, and NREL laboratories, to validate both the process and the results. Finally, in a spotlight over the most vulnerable equipment, which is the EV charge station (AC or DC), the team developed a multi-layer cybersecurity implementation in the embedded domain embodied by the open-source Secure Network Interface Card (SNIC) demonstrating the various ways in which the infrastructure can be secured protecting against the identified attack surfaces. Finally, the entire process of EV infrastructure cybersecurity assessment was encapsulated in the Electric Vehicle Charging Cybersecurity Management (EVC2M) online GUI-based tool, that is expected to be released to the public. The report presents the objectives, the technical approach, the key results, and recommendations for future work.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrating Carbon Capture, Utilization, & Sequestration into Chemical Pulp Mills

The U.S. pulp and paper industry presents a unique and largely untapped opportunity for large- scale carbon dioxide removal (CDR). Unlike most industrial sectors, pulp mills rely heavily on biomass, meaning that much of their carbon emissions originate from atmospheric CO₂ that was recently captured by plants. If this biogenic CO₂ can be captured and permanently stored, pulp mills can be transformed from carbon emitters into net carbon removal facilities. This project was motivated by that opportunity and aimed to develop and evaluate integrated, low-cost strategies for capturing, utilizing, and sequestering CO₂ within existing chemical pulping operations. The scope of this work focused on four complementary innovations designed to integrate seamlessly into kraft pulp mill infrastructure: (1) in situ CO₂ capture within the recovery cycle, (2) oxy-fuel retrofitting of the rotary lime kiln to produce a high-purity CO₂ stream, (3) ex situ CO₂ capture and mineralization using pulp mill residues (dregs, grits, and lime mud), and (4) beneficial reuse of these residues as mineral carbonate fertilizers. The project combined process modeling, laboratory experimentation, life cycle assessment (LCA), and field trials to evaluate the technical feasibility, economic viability, and environmental impact of these approaches. The results demonstrate that pulp mills can serve as effective platforms for carbon removal when equipped with integrated carbon capture systems. Process modeling showed that combining sodium spiking with oxy-fuel calcination significantly enhances CO₂ capture efficiency while reducing costs by up to 31% compared to conventional configurations. Experimental work further revealed that calcination behavior in high-CO₂ environments differs substantially from traditional systems, leading to the development of a new kinetic model that predicts reaction rates under these conditions. This model provides essential design guidance for next-generation decarbonized lime kilns. In parallel, the project demonstrated that alkaline mineral residues generated during pulping operations can be repurposed as a sustainable alternative to agricultural lime. Across a wide range of soils in the southeastern United States, these materials performed equivalently to commercial lime in adjusting soil pH while offering lower greenhouse gas emissions and reduced cost. Field and greenhouse studies confirmed that crop and tree growth responses were comparable, supporting their viability as a drop-in replacement. This co-product pathway provides a practical utilization strategy that offsets costs and improves overall system economics. A major contribution of this project is the first comprehensive life cycle assessment of carbon removal in pulp and paper systems across multiple system boundaries. Results show that retrofitted mills can achieve carbon removal efficiencies ranging from 12% to 92%, depending on how the system is defined. This finding highlights a critical issue in carbon accounting: reported performance is highly sensitive to methodological choices. By explicitly quantifying these differences, this work provides valuable guidance for policymakers, carbon registries, and project developers working to standardize carbon removal metrics. From a commercialization perspective, the technologies investigated in this project are well- aligned with existing industrial infrastructure, minimizing the need for entirely new facilities. 3 DE-EE0009413 Industry engagement throughout the project—including collaboration with pulp and paper companies, equipment manufacturers, and carbon removal developers—has accelerated the transition from research to deployment. Notably, a commercial developer is actively pursuing carbon capture projects at pulp mills in the southeastern United States and has cited this research as a contributing foundation. The emergence of voluntary carbon markets and long-term offtake agreements further strengthens the business case for implementation. The broader public benefits of this work are significant. By enabling large-scale carbon removal using existing industrial systems, this approach offers a near-term pathway to reduce atmospheric CO₂ concentrations while supporting domestic manufacturing and rural economies. The reuse of industrial residues as fertilizers reduces reliance on mined materials, lowers costs for farmers, and decreases environmental impacts associated with conventional lime production. In addition, the project has supported workforce development by training graduate students and researchers in carbon capture technologies, helping to build capacity in a critical area of national interest. In conclusion, this project demonstrates that integrated carbon capture, utilization, and sequestration in pulp mills is both technically feasible and economically promising. By combining process innovation, experimental validation, and systems-level analysis, the work advances the understanding of how biomass-based industries can contribute to climate mitigation. The findings provide a strong foundation for commercial deployment and offer a scalable solution for transforming a major U.S. industry into a source of durable carbon removal.

09 BIOMASS FUELS↗

Session 3: Agrivoltaics Pathways [Slides]

This presentation was developed for a webinar series for the USAID's South Asia Group for Energy (SAGE) and South Asia Regional Energy Partnership (SAREP). The presentation includes insights into agrivoltaic site assessment planning, including what is needed for a farm assessment, solar panel system design from the agricultural perspective, variables that go into crop selection, and environmental impact, sustainability, and agritourism, technical parameters for developing an agrivoltaics project, including what makes up a PV feasibility study, understanding variables that go into technology and equipment selection, agrivoltaic installation and agricultural integration, and monitoring and maintenance throughout the life of the project, and agrivoltaic financial planning, risk mitigation, and debt equity issues.

14 SOLAR ENERGY↗

Connecting the Dots: An Assessment of Cyber-risks in Networked Building and Municipal Infrastructure Systems

The buildings and city streets we walk down are changing. Driven by various data-driven use cases, there is increased interest in networking and integrating lighting and other building systems (e.g., heating, ventilation, and air conditioning (HVAC), security, scheduling) that were previously not internet-facing, and equipping them with sensors that collect information about their environment and the people that inhabit it. These data-enabled systems can potentially deliver improved occupant and resident experiences and help meet the U.S. Department of Energy (DOE) national energy and carbon reduction goals. Deploying connected devices new to being networked, however, is not without its challenges. This paper explores tools available to system designers and integrators that facilitate a cybersecurity landscape assessment – or more specifically the identification of threats, vulnerabilities, and adversarial behaviors that could be used against these networked systems. These assessments can help stakeholders shift security prioritization proactively toward the beginning of the development process.

cyber-risk assesment, adversarial behavior, MITRE ↗

An Assessment of the Usability of Machine Learning Based Tools for the Security Operations Center

Gartner, a large research and advisory company, anticipates that by 2024 80% of security operation centers (SOCs) will use machine learning (ML) based solutions to enhance their operations. 1 1 https://www.ciodive.com/news/how-data-science-tools-can-lighten-the-load-for-cybersecurity-teams/572209/ In light of such widespread adoption, it is vital for the research community to identify and address usability concerns. This work presents the results of the first in situ usability assessment of ML-based tools. With the support of the US Navy, we leveraged the national cyber range-a large, air-gapped cyber testbed equipped with state-of-the-art network and user emulation capabilities-to study six US Naval SOC analysts' usage of two tools. Our analysis identified several serious usability issues, including multiple violations of established usability heuristics for user interface design. We also discovered that analysts lacked a clear mental model of how these tools generate scores, resulting in mistrust a and/or misuse of the tools themselves. Surprisingly, we found no correlation between analysts' level of education or years of experience and their performance with either tool, suggesting that other factors such as prior background knowledge or personality play a significant role in ML-based tool usage. Our findings demonstrate that ML-based security tool vendors must put a renewed focus on working with analysts, both experienced and inexperienced, to ensure that their systems are usable and useful in real-world security operations settings.

Oesch, T↗

Specifying Calibration of Energy-Measuring Equipment

Instruments and standards need to be calibrated periodically to ensure that their use yields accurate measurements. Calibration needs, however, vary in sophistication, based on user expectations. This white paper reviews calibration terminology and standards, and describes best practices that have been developed for a) calibrating measurement equipment to ensure some known level of accuracy, and b) accrediting calibration service providers. Calibration is discussed in the context of metrological traceability, and excerpts from laboratory scopes of accreditation are shared to reveal the diversity of terminology and format among them. In an effort to aid those who currently calibrate measuring equipment or who have new or changing needs for calibrating measuring equipment, rationale is provided for why a specification might be used to request calibration services that meet specific test needs. Given the growing interest in using data to manage the energy consumption of systems, and the increasing number and variety of systems (e.g., building, computing) that can report such information, use cases requiring energy data are used to facilitate further discussion and provide examples. Commercially available service providers who are accredited for energy-measuring equipment calibration are compared and contrasted, and a specification template that might be used for requesting this calibration is presented. The specification template should be tailored to meet each user’s needs. To illustrate, an example set of energy-measuring-equipment test conditions (reflecting the planned usage of the device to be calibrated) is used to develop a customized calibration specification, and commercially available service providers are assessed in terms of their qualifications for calibration to that particular implementation of the specification template.

47 OTHER INSTRUMENTATION↗

Computed Tomography Scanning and Geophysical Measurements of the Wabash No.1 Core

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia were used to characterize Mt. Simon core from the Wabash CarbonSAFE project, Wabash No. 1 well. The primary impetus of the work in this report is a collaboration between NETL Research and Innovation Center and the Illinois State Geological Survey at the Prairie Research Institute, University of Illinois Urbana-Champaign in Champaign, Illinois. The resultant datasets are presented in this report and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/wabash-no-1-well. The Wabash No. 1 well was drilled as part of a U.S. Department of Energy (DOE) funded Carbon Storage Assurance Facility Enterprise field project to assess the feasibility of developing a commercial-scale geological storage complex at the Wabash Valley Resources Integrated Gasification Combined Cycle plant near Terre Haute, Indiana. All equipment and techniques used were non-destructive, enabling future examinations and analyses to be performed on these cores. None of the equipment used was suitable for direct visualization of the pore space in fine-grained structures; fractures, discontinuities, and millimeter scale features were readily detectable with the methods tested. Imaging with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for more detailed analysis. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provides a multi-scale analysis of the core; the resulting macro and micro descriptions are relevant to many subsurface energy-related examinations traditionally performed at NETL.

54 ENVIRONMENTAL SCIENCES↗

Estimating the Breakeven Cost of Delivered Electricity to Charge Class 8 Electric Tractors

As vehicle electrification expands from the light-duty sector to include larger commercial medium- and heavy-duty vehicles, businesses need to decide if electrification is appropriate for their fleets. A key factor in this decision will be the total cost of ownership for on-road electric Class 8 tractors compared to their combustion counterparts. This report examines the breakeven price of electricity for electric Class 8 tractor charging to address its importance in the total cost of ownership for the operation of an electrified fleet and to account for the inherent differences of higher-power charging. To understand the likely cost of delivered energy--in this report the breakeven price--to charge electric tractors, this study followed an analysis framework that considers a wide range of factors to estimate the breakeven price to charge at various station types. This requires an estimation of electric vehicle adoption trajectories and analysis of real-world fleet data to assess energy needs of heavy-duty electric tractors and to determine expected charging station demand over time. Station demand informs the level of electric vehicle supply equipment (EVSE) deployment that is necessary at each station type, as well as the site utilization and anticipated load profiles. Then, by accounting for a wide range of capital investments, operating costs, and other expenses, a breakeven price of energy is determined.

33 ADVANCED PROPULSION SYSTEMS↗

Pilot Testing of a Highly Efficient Pre-combustion Sorbent-based Carbon Capture System

TDA developed and demonstrated a highly efficient pre-combustion carbon capture system. The overall objective of this work was to develop a new sorbent-based pre-combustion carbon capture technology for Integrated Gasification Combined Cycle (IGCC) power plants. In this project our goal was to demonstrate the techno-economic viability of the new technology by 1) demonstrating it in large-scale slipstream tests, and 2) carrying out a high fidelity engineering and cost analysis. TDA’s process used an advanced physical adsorbent that selectively removes CO 2 from coal-derived synthesis gas above the dew point of the gas at temperatures as high as 300°C. The sorbent consists of a mesoporous carbon whose surface was grafted with functional groups that remove CO 2 via a well-known acid-base interaction. As documented in bench-scale experiments and field tests with actual coal gas, the sorbent achieved a very high capacity for CO 2 at temperatures as high as 300°C. The sorbent bound CO 2 more strongly than common physical adsorbents, providing the chemical potential needed for the high temperature operation. However, because CO 2 does not form a true covalent bond with the surface sites (as is the case with chemical absorbents), the sorbent regeneration could be carried out with only a very small energy input. The heat input to regenerate our sorbent was only 4.9 kcal per mol of CO 2 , which is much lower than that for chemical absorbents (e.g., 29.9 kcal/mol CO 2 for sodium carbonate) and was similar to the requirements of physical solvents (e.g., 4 kcal/mol CO 2 for Selexol TM ). Because the sorbent operates above the dew point of the synthesis gas (unlike the Selexol TM process), a higher power cycle efficiency can be achieved. With previous DOE/NETL funding (Contract No. DE-FE-0000469), we demonstrated the techno-economic viability of the technology in bench-scale tests and slipstream demonstrations at the National Carbon Capture Center (NCCC), Wilsonville, Alabama and Wabash River IGCC plant in Terra Haute, Indiana. We demonstrated a stable working CO 2 capacity for over 11,650 cycles with simulated synthesis gas. We also evaluated its performance with actual synthesis gas in two test campaigns at the Wabash River IGCC Plant, Terre Haute, IN and the National Carbon Capture Center (NCCC), Wilsonville, AL. The slipstream tests clearly showed that the actual coal gas constituents and potential contaminants (e.g. trace metals, halides, tars) had no effect on the sorbent’s ability to remove CO 2 (the same sorbent beds were used in both field tests with no sign of deactivation for 2,000 cycles with over 26,750 SCF of gas treated). As expected, due to the high temperature CO 2 removal capability and low energy needed to regenerate the sorbent, the power cycle efficiency with our process was greater than 34% on a higher heating value (HHV) basis; in comparison, the same IGCC plant equipped with the Selexol TM solvent for carbon capture can only achieve 31.4% HHV efficiency. The capital cost for an IGCC system with TDA’s process is estimated as $2,417/kW e , which is 12% lower than that of the IGCC/ Selexol TM process. The levelized cost for electricity including the transport, storage and monitoring (TS&M) cost for CO 2 was calculated as $\$ $92.9/MWh (lowest reported to our knowledge), which is much better than the $105.2/MWh estimated for the IGCC/ Selexol TM process. In this project (DE-FE0013105), TDA Research, in collaboration with our partners Gas Technology Institute (GTI), Illinois Clean Coal Institute (ICCI), University of California, Irvine (UCI), University of Alberta (UOA), Siemens, NCCC and Sinopec advanced the technical maturity of the technology; scaling it up by a factor of 100. We optimized the reactor design using computational fluid dynamics (CFD); using adsorption modeling we improved the pressure swing adsorption (PSA) cycle sequence. We carried out two field test campaigns with a fully-equipped 0.1 MW e prototype unit (for a total of 844 hours) using actual synthesis gas to prove the viability of the new technology. A successful 30 day (707 hrs) evaluation was completed at NCCC under air blown gasification conditions. We demonstrated 97.3% carbon capture at 1,500 SLPM, 93% carbon capture at 1,800 SLPM, and 90% carbon capture at 2,100 SLPM in the NCCC tests. We also demonstrated the system for 137 hours at a Sinopec petrochemical plant under oxygen blown gasification, demonstrating 86% carbon capture at 2,660 SLPM. In collaboration with University of California, Irvine (UCI), we completed a techno-economic analysis (TEA) for TDA’s warm gas cleanup technology integrated to IGCC power plant. The net plant efficiencies (on a coal HHV basis) for the warm gas cleanup cases were estimated to be 34.0% for E-GasTM gasifier, 34.4% for GE gasifier, 33.4 for the Shell gasifier and 34.2 for the TRIG TM gasifier (Cases 2, 4, 6 and 8 in this study) with a catalytic combustor for CO 2 purification, which are significantly higher than those for the Cold Gas Case, or an increase of as much as 12% in the heat rate for Case 2, 6% for Case 4, 9% for Case 6, and 9% for Case 8. The 1st year cost of electricity with the transport, storage and monitoring (TS&M) costs for the CO 2 included was $\$ $129.2/MWh for the E-GasTM gasifier Warm Gas Cleanup Case, $\$ $131.9/MWh for the GE gasifier Warm Gas Cleanup Case, $\$ $146.8/MWh for the Shell Gasifier Warm Gas Cleanup Case, and $\$ $129.9/MWh for the TRIG TM gasifier Warm Gas Cleanup Case. For comparison, the costs for the baseline Cold Gas CO 2 removal with Selexol for the different gasifiers were: $\$ $146.6/MWh for the E-Gas TM gasifier, $\$ $142.2/MWh for the GE gasifier, $\$ $159.0/MWh for the Shell gasifier and $\$ $144.3/MWh for the TRIG TM gasifier. In summary, the costs for our system were 7 to 12% lower than the corresponding Cold Gas Cleanup cases. The results of this techno-economic analysis suggested that TDA’s high temperature PSA-based Warm Gas Clean-up Technology can make a substantial improvement in the IGCC plant thermal performance for achieving near zero CO 2 emissions for E-Gas TM , GE, Shell and TRIG TM gasifier based IGCC power plants. The capital expenses were estimated to be lower than that of Selexol’s™. Taken together, the higher net plant efficiency and lower capital and operating costs resulted in substantial reduction in the cost of carbon capture for the IGCC plant equipped with TDA’s high temperature PSA-based carbon capture system. Finally, in collaboration with Gas Technology Institute (GTI) we completed the environmental health and safety assessment for TDA’s warm gas carbon capture technology.

01 COAL, LIGNITE, AND PEAT↗

Clean energy technology pathways from research to commercialization: Policy and practice case studies

Clean energy research and development (R and D) leading to commercial technologies is vital to economic development, technology competitiveness, and reduced environmental impact. Over the past 30 years, such efforts have advanced technology performance and reduced cost by leveraging network effects and economies of scale. After demonstrating promise in applied R and D, successful clean energy and energy efficiency technologies are incorporated into an initial product sold by the private sector. Despite its importance, processes by which first commercialization occurs are difficult to generalize while capturing specific insights from practitioners in markets and technologies. This paper presents a policy-focused qualitative assessment of the first commercialization of four diverse energy technologies: thin film photovoltaics, wind turbine blades, dual-stage refrigeration evaporators, and fuel cells for material handling equipment. Each technology presents distinct value propositions, markets, and regulatory drivers. The case studies indicate three common characteristics of successful first commercialization for new energy technologies: 1) good fit between the technology, R&D infrastructure, and public-private partnership models; 2) high degree of alignment of government regulations and R&D priorities with market forces; and 3) compatibility between time scales required for R&D, product development, and opportunities. These findings may inform energy investment decision-making, maximize benefits from R&D, and advance the transition to a low-emission future.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Designing Unmanned Aerial Survey Monitoring Program to Assess Floating Litter Contamination

Monitoring marine contamination by floating litter can be particularly challenging since debris are continuously moving over a large spatial extent pushed by currents, waves, and winds. Floating litter contamination have mostly relied on opportunistic surveys from vessels, modeling and, more recently, remote sensing with spectral analysis. This study explores how a low-cost commercial unmanned aircraft system equipped with a high-resolution RGB camera can be used as an alternative to conduct floating litter surveys in coastal waters or from vessels. The study compares different processing and analytical strategies and discusses operational constraints. Collected UAS images were analyzed using three different approaches: (i) manual counting (MC), using visual inspection and image annotation with object counts as a baseline; (ii) pixel-based detection, an automated color analysis process to assess overall contamination; and (iii) machine learning (ML), automated object detection and identification using state-of-the-art convolutional neural network (CNNs). Our findings illustrate that MC still remains the most precise method for classifying different floating objects. ML still has a heterogeneous performance in correctly identifying different classes of floating litter; however, it demonstrates promising results in detecting floating items, which can be leveraged to scale up monitoring efforts and be used in automated analysis of large sets of imagery to assess relative floating litter contamination.

Almeida, Sílvia (ORCID:0000000320636826)↗

EVI-LOCATE User Manual

One of the longest stages in the deployment of electric vehicle supply equipment (EVSE) is the initial planning of the infrastructure itself. Engineers and fleet experts from the National Renewable Energy Laboratory (NREL) have supported dozens of charging infrastructure site plans over the past couple decades, including the generation of site schematics, determinations of electric capacity, and estimates for likely costs. As the market for electric vehicles (EVs) has matured, this approach should no longer require a time and personnel intensive process. In order to shorten the time taken to develop site plans and cost estimates, NREL developed a tool that fleet managers, facility managers, electricians, EVSE installers, and members of the public can use to develop initial schematics and ballpark pricing for charging station installations. The Electric Vehicle Infrastructure - Locally Optimized Charger Assessment Tool and Estimator (EVI-LOCATE) provides a structured and consistent way for users to enter information about their planned EVSE project in a relatively simple web-based format. EVI-LOCATE then calculates electrical equipment capacity, wiring runs, and project costs. It produces a site diagram optimized around surface characteristics with differential trenching costs for softscape such as grass compared to hardscape such as asphalt that can be adjusted by users in the tool. It also stores the resulting site plans and costs in a dashboard for access at a later date, including plan revisions if necessary. This document guides users through the EVI-LOCATE screens and associated questions. It contains tip text boxes throughout on how best to interface with the tool and find additional information or context. The appendices contain the assumptions and calculations underpinning the tool. Much of the information for EVI-LOCATE was gathered through industry engagements with EVSE installers, invoices from completed EVSE installations, Gordian's RS Means construction data, and the General Services Administration blanket purchase agreement for EVSE. For a visual tutorial of the tool, users can watch EVI-LOCATE Step-by-Step Video. The tool itself is available at https://evi-locate.nrel.gov.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Extending the Brick schema to represent metadata of occupants

Here, energy-related behaviors of occupants constitute a key factor influencing building performance; accordingly, the measured occupant data can support the objective assessment of the indoor environment and energy performance of buildings, which can inform building design and operational decisions. Existing data schemas focus on metadata of sensors, meters, physical equipment, and IoT devices in buildings; however, they are limited in representing the metadata of occupant data, including occupants' presence in spaces, movement between spaces, interactions with building systems or IoT devices, and preference of indoor environmental needs. To address this gap, an extension to the widely adopted metadata schema, Brick, is proposed to represent the contextual, behavioral, and demographic information of occupants. The proposed extension includes four parts: (1) a new “Occupant” class to represent occupants' demography and energy related behavioral patterns, (2) new subclasses under the Equipment class to represent envelope system and personal thermal comfort devices, (3) new subclasses under the Point class to represent occupant sensing and status, and (4) new auxiliary properties for occupant interactable equipment to represent the level of controllability for each piece of equipment by occupants. The extension is implemented in the Brick schema and has been tested using multiple occupant datasets from the ASHRAE Global Occupant Database. The extension enables Brick schema to capture diverse types of occupant sensing data and their metadata for FAIR data research and applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing DER Network Cybersecurity Defences in a Power-Communication Co-Simulation Environment

Increasing penetrations of interoperable distributed energy resources (DER) in the electric power system are expanding the power system attack surface. Maloperation or malicious control of DER equipment can now cause substantial disturbances to grid operations. Fortunately, many options exist to defend and limit adversary impact on these newly-created DER communication networks, which typically traverse the public internet. However, implementing these security features will increase communication latency, thereby adversely impacting real-time DER grid support service effectiveness. In this work, a collection of software tools called SCEPTRE were used to create a co-simulation environment where SunSpec-compliant PV inverters were deployed as virtual machines and interconnected to simulated communication network equipment. Network segmentation, encryption, and moving target defence security features were deployed on the control network to evaluate their influence on cybersecurity metrics and power system performance. The results indicated that adding these security features did not impact DER-based grid control systems but improved the cybersecurity posture of the network when implemented appropriately.

97 MATHEMATICS AND COMPUTING↗

Characterizing Ocean Acidification and Atmospheric Emission caused by Methane Released from Gas Hydrate Systems along the US Atlantic Margin (Final Report)

To assess the environmental impact of decomposing gas hydrates, this project characterized the atmospheric emission and ocean acidification associated with seafloor-released methane along the U.S. Atlantic Margin. This project leveraged the newly discovered seafloor seeps in this region, many of which are located near the landward limit of gas hydrate stability, to investigate the fate and environmental impact of methane once released from the seafloor. Several research directions were pursued during these investigations. First, high-spatial resolution surface surveys were conducted to characterize the degree to which sea-to-air emission of methane is correlated with acoustically detected seafloor bubble emissions. Second, the natural isotopic signatures of both radiocarbon and δ 13 C were measured throughout the water column to observe if seafloor-released methane was detected in surface waters or if it was replaced by a different source. Third, the extent of methane oxidation in the water column was constrained to assess the ability of this process to mitigate atmospheric methane emissions. Fourth, since aerobic methane oxidation ultimately converts methane to carbon dioxide, the extent of ocean acidification relating to this process was assessed. Ultimately, this project was conducted in four stages. Stage one involved preparations for the research expedition along the U.S. Atlantic Margin. This involved calibrating, modifying, and validating equipment needed for sample and data collection in this unique environment. Stage two involved executing the at-sea science. This research was conducted from 25 August to 5 September 2017 on the R/V Hugh R. Sharp. This expedition left from Lewes, Delaware and investigated the continental slope from approximately this latitude down to Cape Hatteras, North Carolina. Third, any samples unanalyzed on the research vessel were returned to the laboratory and measured. Fourth, the data were interpreted, and publications and presentations were prepared.

03 NATURAL GAS↗

MSTL Re-Start Phase 1.5 Project Final Report

This document provides an overview of re-start efforts at Sandia National Laboratories (SNL), National Solar Thermal Test Facility (NSTTF), for the SNL Molten Salt Test Loop (MSTL). MSTL is one of the world’s only industrial-scale molten salt test systems, capable of testing commercial-scale thermal hydraulic equipment at an industrial scale, required for confident bankability of products. This work was facilitated as part of the Phase 1 re-start effort for facilitating forensics assessments to inform final refurbishments and upgrades costs and schedule information for revitalizing MSTL for use during a separate Phase 2 effort. This work was facilitated to further de-risk a Phase 2 effort pertaining to the tank and the pump, which were considered during Phase 1 to be high-risk items for a successful re-start. Impact from a successful re-start will allow SNL and other industrial molten salt systems companies, such as those in the Market Utilization Report provided in the Phase 1 submission package. An objective of this document is to also ensure longevity of utilization of MSTL after re start.

14 SOLAR ENERGY↗

Rapid Detection of Anomalies in Battery Energy Storage System Data

Data analytics is pivotal in assessing the technical characteristics and performance of Battery Energy Storage Systems (BESS), underpinning BESS modeling, optimization, and control. However, raw datasets frequently harbor anomalies from measurement errors and equipment malfunctions, impacting BESS reliability and analysis accuracy To address the challenge, this paper presents a novel methodology for the rapid detection of anomalous charge or discharge cycles within BESS operational data, expediting the cleaning process while ensuring data integrity. We’ve collected diverse and comprehensive real-world BESS operational datasets in collaboration with the Electric Power Research Institute and multiple Washington State utilities. These datasets serve dual roles: enabling comprehensive data exploration and analysis for understanding underlying challenges and method development, while also acting as a vital validation resource, demonstrating practical effectiveness. The proposed method detects anomalies and aids in their resolution, improving system performance characterization precision. It also reveals recurring data anomaly sources, offering insights for data collection and handling enhancement. Practitioners can gain valuable insights from the identified anomalous cycles in the real-world datasets along with the investigative process for root cause analyses and essential data cleaning steps.

Crawford, Aladsair J.↗

Application Experiences on a GPU-Accelerated Arm-based HPC Testbed

This paper assesses and reports the experience of ten teams working to port, validate, and benchmark several High Performance Computing applications on a novel GPU-accelerated Arm testbed system. The testbed consists of eight NVIDIA Arm HPC Developer Kit systems, each one equipped with a server-class Arm CPU from Ampere Computing and two data center GPUs from NVIDIA Corp. The systems are connected together using InfiniBand interconnect. The selected applications and mini-apps are written using several programming languages and use multiple accelerator-based programming models for GPUs such as CUDA, OpenACC, and OpenMP offloading. Working on application porting requires a robust and easy-to-access programming environment, including a variety of compilers and optimized scientific libraries. The goal of this work is to evaluate platform readiness and assess the effort required from developers to deploy well-established scientific workloads on current and future generation Arm-based GPU-accelerated HPC systems. The reported case studies demonstrate that the current level of maturity and diversity of software and tools is already adequate for large-scale production deployments.

Elwasif, Wael↗