Search NASA⌕ Search

SEARCH · Search NASA

Results for “Error Mitigation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Limitations and Feasibility of Mini X-Ray Devices in Space Environments

LIMITATIONS AND FEASIBILITY OF MINI X-RAY DEVICES IN SPACE ENVIRONMENTS As space exploration advances toward long-duration missions, reliable medical diagnostic tools become increasingly critical. The miniature x-ray (XR) technology demonstrations by the Exploration Medical Capability (ExMC) and the Exploration Medical Integrated Product Team (XMIPT) aim to assess the feasibility and utility of miniature XR devices in spaceflight. This abstract explores the limitations of current miniature XR systems, the challenges of training crew members, the potential role of clinical decision support systems (CDSS), and the feasibility of ground-based image interpretation. We also propose the integration of miniature XR into other ExMC efforts aimed at identifying the capabilities and resources needed for future exploration class missions. One of the primary challenges with miniature XR devices is the ability to achieve specific anatomical views, particularly in the confined and weightless conditions of a spacecraft. Operators may struggle to acquire diagnostic-quality images when space is limited for proper patient positioning and the volume of the imaging device. Since space radiation and detector limitations may further impact image quality, the flexibility of the operating procedures of these devices will be critical for their success in space applications. CHALLENGES IN TRAINING CREW TO OPERATE IMAGING DEVICES Training in the skills necessary to acquire diagnostic-quality scans may be a barrier for non-clinician crewmembers. The curriculum developed for crew medical officers (CMOs) will require simplification and adaptation to fit into the highly truncated pre-flight training period. Therefore, hands-on familiarization and simulation, both pre-flight and just-in-time training during missions, will be crucial to ensuring the crew can operate the devices in real-life situations. The ability to adjust acquisition parameters must be simplified or made automatic through exam selections on equipment user interfaces, and subject and operator positioning should be assisted with laser guidance and pictorial guides. POTENTIAL FOR CDSS OR ARTIFICIAL INTELLIGENCE (AI)-ASSISTED CDSS CDSS and AI-assisted CDSS offer significant promise in assisting crew members with limited medical training. These systems could provide real-time feedback on image quality and interpretation, helping to mitigate the risks of human error during space missions. Integrating procedural guidance tools, such as virtual and augmented reality, will support crewmembers in accurately positioning patients and obtaining high-quality images. However, the success of such systems will depend on the development of robust training datasets, integration with spaceflight-rated hardware, and the medical decision-making capabilities of operators. FEASIBILITY OF GROUND INTERPRETATION AND DATA TRANSMISSION Reliance on ground-based interpretation may prove difficult for acute care during exploration class-missions due to delays in transmission with increasing distance from Earth or complete communication blackout periods. In such instances where immediate interpretation for clinical intervention is required, crew must be able to interpret the images independently or utilize AI-based assistance to do so. File sizes for XR exams can also be large if numerous images are acquired and bandwidth constraints may limit data transmissions for both radiography and ultrasound exams. FUTURE WORK AND INTEGRATION INTO THE EVIDENCE LIBRARY Future work proposes integrating miniature XR devices into NASA’s Evidence Library to address medical conditions identified as significant contributors to crew morbidity and mortality. The possibility of combining miniature XR with other imaging modalities, such as ultrasound devices, is also under investigation. In conclusion, while miniature XR technology holds potential for extraterrestrial medical systems, there are significant challenges to overcome. Training, integration of AI tools, dedicated exam protocols for microgravity, and improved data transmission systems will be key to realizing the full benefits of miniature XR technology in space.

A M Nelson↗

Fast Plasma Investigation for MMS: Simulation of the Burst Triggering System

The Magnetospheric Multiscale (MMS) mission will study small-scale reconnection structures and their rapid motions from closely spaced platforms using instruments capable of high angular, energy, and time resolution measurements. To meet these requirements, the Fast Plasma Instrument (FPI) consists of eight (8) identical half top-hat electron sensors and eight (8) identical ion sensors and an Instrument Data Processing Unit (IDPU). The sensors (electron or ion) are grouped into pairs whose 6 degree x 180 degree fields-of-view (FOV) are set 90 degrees apart. Each sensor is equipped with electrostatic aperture steering to allow the sensor to scan a 45 degree x 180 degree fan about the its nominal viewing (0 deflection) direction. Each pair of sensors, known as the Dual Electron Spectrometer (DES) and the Dual Ion Spectrometer (DIS), occupies a quadrant on the MMS spacecraft and the combination of the eight electron/ion sensors, employing aperture steering, image the full-sky every 30-ms (electrons) and 150-ms (ions), respectively. To probe the diffusion regions of reconnection, the highest temporal/spatial resolution mode of FPI results in the DES complement of a given spacecraft generating 6.5-Mb (raised dot) per second of electron data while the DIS generates 1.1-Mb (raised dot) per second of ion data yielding an FPI total data rate of 6.6-Mb (raised dot) per second. The FPI electron/ion data is collected by the IDPU then transmitted to the Central Data Instrument Processor (CIDP) on the spacecraft for science interest ranking. Only data sequences that contain the greatest amount of temporal/spatial structure will be intelligently down-linked by the spacecraft. This requires a data ranking process known as the burst trigger system. The burst trigger system uses pseudo physical quantities to approximate the local plasma environments. As each pseudo quantity will have a different value, a set of two scaling factors is employed for each pseudo term. These pseudo quantities are then combined at the instrument, spacecraft, and observatory level leading to a final ranking of data based on expected scientific interest. Here, we present simulations of the fixed point burst trigger system for the FPI. A variety of data sets based on previous mission data as well as analytical formulations are tested. Comparisons of floating point calculations versus the fixed point hardware simulation are shown. Analysis of the potential sources of error from overflows, quantization, etc. are examined and mitigation methods are presented. Finally a series of calibration curves are presented, showing the expected error in pseudo quantities based solely on the scale parameters chosen and the expected data range. We conclude with a presentation of the current base-lined FPI burst trigger approach.

Barrie, A. C.↗

Factors affecting the accuracy of near-infrared spectroscopy concentration calculations for focal changes in oxygenation parameters

Near-infrared spectroscopy (NIRS) can be used to noninvasively measure changes in the concentrations of oxy- and deoxyhemoglobin in tissue. We have previously shown that while global changes can be reliably measured, focal changes can produce erroneous estimates of concentration changes (NeuroImage 13 (2001), 76). Here, we describe four separate sources for systematic error in the calculation of focal hemoglobin changes from NIRS data and use experimental methods and Monte Carlo simulations to examine the importance and mitigation methods of each. The sources of error are: (1). the absolute magnitudes and relative differences in pathlength factors as a function of wavelength, (2). the location and spatial extent of the absorption change with respect to the optical probe, (3). possible differences in the spatial distribution of hemoglobin species, and (4). the potential for simultaneous monitoring of multiple regions of activation. We found wavelength selection and optode placement to be important variables in minimizing such errors, and our findings indicate that appropriate experimental procedures could reduce each of these errors to a small fraction (<10%) of the observed concentration changes.

Non-NASA Center↗

Detailed Characterization of CZT Detector Response for Improved Coded-Aperture Imaging Performance

Gamma-ray imaging is a powerful method for locating and quantifying sources of radiation. The coded-aperture technique demonstrates superior angular resolution in comparison to other methods (e.g., Compton reconstruction). In this method, a mask constructed of highly attenuating material encodes the scene as a shadow pattern on a position-sensitive detector; this pattern can then be used to recreate the origin(s) of incident radiation. This is typically done through convolution of the mask and shadow patterns. Iterative methods which attempt to reconstruct the observed shadow pattern using a weighted combination of simulated patterns may also be employed. In either case, errors in event position reconstruction due to detector imperfections alter the shadow pattern and will therefore degrade system performance and may introduce imaging artifacts. These effects can be mitigated with a detailed understanding of such errors – allowing for the generation of representative simulations that include the errors and/or correction of raw imager data to remove the errors. We present a calibration process for a commercially available cadmium zinc telluride (CZT) gamma imager which provides a comprehensive characterization of the spatial and energy dependence of event reconstruction. By illuminating a mask featuring a regular grid of pinholes with a calibration source, the localized response of the detector can be measured with fine granularity. These local responses are combined to generate a full detector response map which can be used to distort simulations in a manner that is representative of the observed detector data. Details of the calibration procedure and an assessment of the impact of its end products on the performance of iterative imaging methods will be presented.

Ziock, Klaus-Peter↗

Understanding and Estimating Error Propagation in Neural Networks for Scientific Data Analysis

Neural networks are increasingly integrated into scientific discovery, where input data reduction and model quantization play a key role in accelerating inference. However, understanding and mitigating the impact of these techniques on output error is critical for ensuring reliable results, particularly in tasks demanding high numerical precision. This paper introduces a comprehensive framework for optimizing neural network inference in scientific computing by combining data reduction and weight quantization while maintaining error-controlled outcomes. We develop theoretical analyses to bound error propagation under these reductions and propose a framework that balances computational performance with error constraints. Evaluation on real-world learning-based combustion simulations and satellite image classification demonstrates that our derived error bounds accurately predict observed errors while enabling significant computational speedup under our framework. This work highlights the potential for further leveraging advancements in modern lossy compression algorithms and hardware accelerators that support lower-precision formats.

He, Weiming [New Jersey Institute of Technology]↗

PIP-II LLRF Master Oscillator and Precision Reference Line - Station Level Design and Testing

The PIP-II superconducting linac at Fermilab requires a highly stable RF Reference Line to maintain phase syn- chronization throughout the accelerator. Temperature- induced changes in the electrical length of long coaxial cables can introduce phase drift and measurement errors. The reference-line architecture mitigates these effects by phase averaging the forward and reflected RF signals, while a phase-locked loop anchors the system to the mas- ter oscillator. This work focuses on the characterization, validation, and mechanical integration of station-level RF assemblies using CAD modeling, vector network analyzer measurements, and spectrum analyzer testing. PID-controlled thermal plates will stabilize critical RF components and further reduce temperature-dependent phase and amplitude variations. These methods sup- port repeatable, standardized designs that can be reliably integrated across the different reference-line stations.

Mosher, Alexander [U. Illinois, Chicago]↗

Mitigation of High Altitude and Low Earth Orbit Radiation Effects on Microelectronics via Shielding or Error Detection and Correction Systems

The NASA Cooperative Agreement NAG4-210 was granted under the FY2000 Faculty Awards for Research (FAR) Program. The project was proposed to examine the effects of charged particles and neutrons on selected random access memory (RAM) technologies. The concept of the project was to add to the current knowledge of Single Event Effects (SEE) concerning RAM and explore the impact of selected forms of radiation on Error Detection and Correction Systems. The project was established as an extension of a previous FAR awarded to Prairie View A&M University (PVAMU), under the direction of Dr. Richard Wilkins as principal investigator. The NASA sponsored Center for Applied Radiation Research (CARR) at PVAMU developed an electronic test-bed to explore and quantify SEE on RAM from charged particles and neutrons. The test-bed was developed using 486DX microprocessor technology (PC-104) and a custom test board to mount RAM integrated circuits or other electronic devices. The test-bed had two configurations - a bench test version for laboratory experiments and a 400 Hz powered rack version for flight experiments. The objectives of this project were to: 1) Upgrade the Electronic Test-bed (ETB) to a Pentium configuration; 2) Accommodate more than only 8 Mbytes of RAM; 3) Explore Error Detection and Correction Systems for radiation effects; 4) Test modern RAM technologies in radiation environments.

Gupta, Kajal↗

Modeling of Deadbanding DV for the Stardust Earth Return: Calibration, Analysis, Prediction and Performance

On January 15th, 2006, 0556 UTC, the Stardust spacecraft released a 42-kg Sample Return Canister (SRC) along a trajectory intended to impact a target on the Air Force Utah Test and Training Range (UTTR), near Dugway, Utah. Assurances of a successful SRC delivery to UTTR depended on identifying (and mitigating, if possible) a myriad of error sources. These sources included atmospheric effects, maneuver execution, Orbit Determination (OD) uncertainties and (Delta)V induced by the firing of the unbalanced Reaction Control System (RCS) thrusters needed for deadband attitude control. Every mm/s in prediction error at the TCM-19 epoch would amount to missing the target by approximately one kilometer. This paper will describe the work performed in analyzing and predicting the levels of (Delta)V caused by the attitude deadbanding, as well as prediction performance.

Stardust↗

Using Thin-Film Thermometers as Heaters in Thermal Control Applications

A cryogenic sensor maintains calibration at approximately equal to 4.2 K to better than 2 mK (< 0.5 percent resistance repeatability) after being heated to approximately equal 40 K with approximately equal 0.5 W power. The sensor withstands 4 W power dissipation when immersed in liquid nitrogen with verified resistance reproducibility of, at worst, 1 percent. The sensor maintains calibration to 0.1 percent after being heated with 1-W power at approximately equal 77 K for a period of 48 hours. When operated with a readout scheme that is capable of mitigating the self-heating calibration errors, this and similar sensors can be used for precision (mK stability) temperature control without the need of separate heaters and associated wiring/cabling.

Cho, Hyung J.↗

Post-Coronagraph Wavefront Sensor for Gemini Planet Imager

The calibration wavefront system for the Gemini Planet Imager (GPI) will measure the complex wavefront at the apodized pupil and provide slow phase errors to the AO system to mitigate against image plane speckles that would cause a loss in contrast. This talk describes both the low-order and high-order sensors in the calibration wavefront sensor and how the information is combined to form the wavefront estimate before the coronagraph. We will show laboratory results from our calibration testbed that demonstrate the subsystem performance at levels commensurate with those required on the final instrument.

interferometry↗

Trajectory Design Enhancements to Mitigate Risk for the Transiting Exoplanet Survey Satellite (TESS)

The Transiting Exoplanet Survey Satellite (TESS) will employ a highly eccentric Earth orbit, in 2:1 lunar resonance, which will be reached with a lunar flyby preceded by 3.5 phasing loops. The TESS mission has limited propellant and several constraints on the science orbit and on the phasing loops. Based on analysis and simulation, we have designed the phasing loops to reduce delta-V (DV) and to mitigate risk due to maneuver execution errors. We have automated the trajectory design process and use distributed processing to generate and optimal nominal trajectories; to check constraint satisfaction; and finally to model the effects of maneuver errors to identify trajectories that best meet the mission requirements.

satellite↗

Trajectory Design to Mitigate Risk on the Transiting Exoplanet Survey Satellite (TESS) Mission

The Transiting Exoplanet Survey Satellite (TESS) will employ a highly eccentric Earth orbit, in 2:1 lunar resonance, reached with a lunar flyby preceded by 3.5 phasing loops. The TESS mission has limited propellant and several orbit constraints. Based on analysis and simulation, we have designed the phasing loops to reduce delta-V and to mitigate risk due to maneuver execution errors. We have automated the trajectory design process and use distributed processing to generate and to optimize nominal trajectories, check constraint satisfaction, and finally model the effects of maneuver errors to identify trajectories that best meet the mission requirements.

design↗

A Quantum Volume Metric for Qudit Quantum Computers

Qudit-based quantum computers, such as the high-Q superconducting radio frequency resonator cavities being pursued by the SQMS Center hosted at Fermilab, may provide computational advantages relative to qubit-based machines for some problems. However, the novel system’s hardware and software will present different errors that must be understood and mitigated, along with other unforeseen inefficiencies across the entire stack. It is essential to benchmark these qudit platforms against existing systems. We propose such a benchmark by generalizing the qubit-based quantum volume metric to qudit devices. In particular, we show that the performance depends on the available gateset used to compile unitary operations, as well as realistic noise sources.

Quantum Computing↗

PIP-II LLRF Master Oscillator and Precision Reference Line- Station Level Design and Testing

The PIP-II superconducting linac at Fermilab requires a highly stable RF Reference Line to maintain phase synchronization throughout the accelerator. Temperature-induced changes in the electrical length of long coaxial cables can introduce phase drift and measurement errors. The reference-line architecture mitigates these effects by phase averaging the forward and reflected RF signals, while a phase-locked loop anchors the system to the master oscillator. This work focuses on the characterization, validation, and mechanical integration of station-level RF assemblies using CAD modeling, vector network analyzer measurements, and spectrum analyzer testing. PID-controlled thermal plates will stabilize critical RF components and further reduce temperature-dependent phase and amplitude variations. These methods support repeatable, standardized designs that can be reliably integrated across the different reference-line stations.

Mosher, Alexander [U. Illinois, Chicago; Fermilab]↗

New Developments in FPGA: SEUs and Fail-Safe Strategies from the NASA Goddard Perspective

It has been shown that, when exposed to radiation environments, each Field Programmable Gate Array (FPGA) device has unique error signatures. Subsequently, fail-safe and mitigation strategies will differ per FPGA type. In this session several design approaches for safe systems will be presented. It will also explore the benefits and limitations of several mitigation techniques. The intention of the presentation is to provide information regarding FPGA types, their susceptibilities, and proven fail-safe strategies; so that users can select appropriate mitigation and perform the required trade for system insertion. The presentation will describe three types of FPGA devices and their susceptibilities in radiation environments.

Error Correction and Detection (EDAC)↗

New Developments in FPGA: SEUs and Fail-Safe Strategies from the NASA Goddard Perspective

It has been shown that, when exposed to radiation environments, each Field Programmable Gate Array (FPGA) device has unique error signatures. Subsequently, fail-safe and mitigation strategies will differ per FPGA type. In this session several design approaches for safe systems will be presented. It will also explore the benefits and limitations of several mitigation techniques. The intention of the presentation is to provide information regarding FPGA types, their susceptibilities, and proven fail-safe strategies; so that users can select appropriate mitigation and perform the required trade for system insertion. The presentation will describe three types of FPGA devices and their susceptibilities in radiation environments.

hardware description language (HDL)↗

New Developments in FPGA Devices: SEUs and Fail-Safe Strategies from the NASA Goddard Perspective

It has been shown that, when exposed to radiation environments, each Field Programmable Gate Array (FPGA) device has unique error signatures. Subsequently, fail-safe and mitigation strategies will differ per FPGA type. In this session several design approaches for safe systems will be presented. It will also explore the benefits and limitations of several mitigation techniques. The intention of the presentation is to provide information regarding FPGA types, their susceptibilities, and proven fail-safe strategies; so that users can select appropriate mitigation and perform the required trade for system insertion. The presentation will describe three types of FPGA devices and their susceptibilities in radiation environments.

Field Programmable Gate Array (FPGA)↗