Search NASA⌕ Search

SEARCH · Search NASA

Results for “FAR ULTRAVIOLET RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Laser Desorption Postionization Mass Spectrometry of Antibiotic-Treated Bacterial Biofilms using Tunable Vacuum Ultraviolet Radiation

Laser desorption postionization mass spectrometry (LDPI-MS) with 8.0 ? 12.5 eV vacuum ultraviolet synchrotron radiation is used to single photon ionize antibiotics andextracellular neutrals that are laser desorbed both neat and from intact bacterial biofilms. Neat antibiotics are optimally detected using 10.5 eV LDPI-MS, but can be ionized using 8.0 eV radiation, in agreement with prior work using 7.87 eV LDPI-MS. Tunable vacuum ultraviolet radiation also postionizes laser desorbed neutrals of antibiotics and extracellular material from within intact bacterial biofilms. Different extracellular material is observed by LDPI-MS in response to rifampicin or trimethoprim antibiotic treatment. Once again, 10.5 eV LDPI-MS displays the optimum trade-off between improved sensitivity and minimum fragmentation. Higher energy photons at 12.5 eV produce significant parent ion signal, but fragment intensity and other low mass ions are also enhanced. No matrix is added to enhance desorption, which is performed at peak power densities insufficient to directly produce ions, thus allowing observation of true VUV postionization mass spectra of antibiotic treated biofilms.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Space-resolved vacuum ultraviolet spectrometer system for edge impurity and temperature profile measurement in HL-2A

A 1 m normal incidence vacuum ultraviolet (VUV) spectrometer has been developed for spatial distribution measurement of edge impurity line emission in the wavelength range of 300-3200 A on HL-2A tokamak. A vertical profile of the impurity line emission is measured with a space-resolved slit placed between an entrance slit and a grating of the spectrometer. Two concave 1200 grooves/mm gratings blazed at 800 and 1500 A are set on a rotatable holder in the spectrometer, which gives wavelength dispersion of 0.12 mm/A. A back-illuminated charge-coupled device is used as a detector with an image size of 6.7x26.6 mm{sup 2} (26x26 {mu}m{sup 2}/pixel). An excellent spatial resolution of 2 mm is obtained with good spectral resolution of 0.15 A when the space-resolved slit of 50 {mu}m in width is used. The space-resolved spectra thus provide three radial profiles of emission line intensity, ion temperature, and poloidal rotation. The electron temperature can be measured by the intensity ratio, e.g., CIII 2s{sup 2}-2s3p (386 A)/2s{sup 2}-2s2p (977 A). The sensitivity of the spectrometer is calibrated in situ by using the VUV bremsstrahlung continuum radiation emitted from the tokamak plasma. A good performance of the spectrometer system for the edge impurity and temperature profile measurements is presented with results on Ohmic and H-mode discharges.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of surface vacuum ultraviolet emissions with resonance level number densities. II. Rare-gas plasmas and Ar-molecular gas mixtures

Vacuum ultraviolet (VUV) emissions from excited plasma species can play a variety of roles in processing plasmas, including damaging the surface properties of materials used in semiconductor processing. Depending on their wavelength, VUV photons can easily transmit thin upper dielectric layers and affect the electrical characteristics of the devices. Despite their importance, measuring VUV fluxes is complicated by the fact that few materials transmit at VUV wavelengths, and both detectors and windows are easily damaged by plasma exposure. The authors have previously reported on measuring VUV fluxes in pure argon plasmas by monitoring the concentrations of Ar(3p{sup 5}4s) resonance atoms that produce the VUV emissions using noninvasive optical emission spectroscopy in the visible/near-infrared wavelength range [Boffard et al., J. Vac. Sci. Technol., A 32, 021304 (2014)]. Here, the authors extend this technique to other rare-gases (Ne, Kr, and Xe) and argon-molecular gas plasmas (Ar/H{sub 2}, Ar/O{sub 2}, and Ar/N{sub 2}). Results of a model for VUV emissions that couples radiation trapping and the measured rare-gas resonance level densities are compared to measurements made with both a calibrated VUV photodiode and a sodium salicylate fluorescence detection scheme. In these more complicated gas mixtures, VUV emissions from a variety of sources beyond the principal resonance levels of the rare gases are found to contribute to the total VUV flux.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

UV + V UV double-resonance studies of autoionizing Rydberg states of the hydroxyl radical

The hydroxyl radical (OH) is a key oxidant in atmospheric and combustion chemistry. Recently, a sensitive and state-selective ionization method has been developed for detection of the OH radical that utilizes UV excitation on the A{sup 2}Σ{sup +}–X{sup 2}Π transition followed by fixed 118 nm vacuum ultraviolet (VUV) radiation to access autoionizing Rydberg states [J. M. Beames et al., J. Chem. Phys. 134, 241102 (2011)]. The present study uses tunable VUV radiation generated by four-wave mixing to examine the origin of the enhanced ionization efficiency observed for OH radicals prepared in specific A{sup 2}Σ{sup +} intermediate levels. The enhancement is shown to arise from resonant excitation to distinct rotational and fine structure levels of two newly identified {sup 2}Π Rydberg states with an A{sup 3}Π cationic core and a 3d electron followed by ionization. Spectroscopic constants are derived and effects due to uncoupling of the Rydberg electron are revealed for the OH {sup 2}Π Rydberg states. The linewidths indicate a Rydberg state lifetime due to autoionization on the order of a picosecond.

74 ATOMIC AND MOLECULAR PHYSICS↗

Identification of combustion intermediates in a low-pressure premixed laminar 2,5-dimethylfuran/oxygen/argon flame with tunable synchrotron photoionization

Low-pressure (4.0 kPa) premixed laminar 2,5-dimethylfuran (DMF)/oxygen/argon flame with an equivalence ratio of 2.0 was studied with tunable vacuum ultraviolet (VUV) synchrotron radiation photoionization and molecular-beam mass spectrometry. Photoionization mass spectra of DMF/O{sub 2}/Ar flame were recorded and the photoionization efficiency curves of the combustion intermediates were measured. Flame species, including isomeric intermediates, are identified by comparing the measured ionization energies with those reported in literatures or those calculated with Gaussian-3 procedure. More than 70 species have been detected, including furan and its derivatives, aromatics, and free radicals. Possible reaction pathways of DMF, 2-methylfuran, and furan are proposed based on the intermediates identified. DMF can be consumed by H-abstraction and pyrolysis reactions. 2-Methylfuran and furan can be consumed by H-abstraction, H-addition and pyrolysis reactions. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Photoelectron Spectroscopy of Anions at 118.2 nm. Observation of High Electron Binding Energies in Superhalogens MCI 4 - (M=Sc, Y, La)

High energy photon is needed for photoelectron spectroscopy (PES) of anions with high electron binding energies, such as superhalogens and O-rich metal oxide clusters. The highest energy photon used for anion PES in the laboratory has been 157 nm (7.866 eV) from F2 eximer lasers. Here, we report an anion PES experiment using coherent vacuum ultraviolet radiation at 118.2 nm (10.488 eV) by tripling the third harmonic output (355 nm) of a Nd:YAG laser in a Xe/Ar cell. Our study focuses on a set of superhalogen species, MCI 4 - (M=Sc, Y, La), which were expected to possess very high electron binding energies. While the 157 nm photon can only access the ground state detachment features for these species, more transitions to the excited states at binding energies higher than 8 eV are observed at 118.2 nm. The adiabatic detachment energies are shown to be, 6.84, 7.02, and 7.03 eV for ScCl 4 - , YCl 4 - , and LaCl 4 - eV, respectively, whereas their corresponding vertical detachment energies are measured to be 7.14, 7.31, and 7.38 eV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Core-ion temperature measurement of the ADITYA tokamak using passive charge exchange neutral particle energy analyzer

Core-ion temperature measurements have been carried out by the energy analysis of passive charge exchange (CX) neutrals escaping out of the ADITYA tokamak plasma (minor radius, a= 25 cm and major radius, R= 75 cm) using a 45 Degree-Sign parallel plate electrostatic energy analyzer. The neutral particle analyzer (NPA) uses a gas cell configuration for re-ionizing the CX-neutrals and channel electron multipliers (CEMs) as detectors. Energy calibration of the NPA has been carried out using ion-source and {Delta}E/E of high-energy channel has been found to be {approx}10%. Low signal to noise ratio (SNR) due to VUV reflections on the CEMs was identified during the operation of the NPA with ADITYA plasma discharges. This problem was rectified by upgrading the system by incorporating the additional components and arrangements to suppress VUV radiations and improve its VUV rejection capabilities. The noise rejection capability of the NPA was experimentally confirmed using a standard UV-source and also during the plasma discharges to get an adequate SNR (>30) at the energy channels. Core-ion temperature T{sub i}(0) during flattop of the plasma current has been measured to be up to 150 eV during ohmically heated plasma discharges which is nearly 40% of the average core-electron temperature (typically T{sub e}(0) {approx} 400 eV). The present paper describes the principle of tokamak ion temperature measurement, NPA's design, development, and calibration along with the modifications carried out for minimizing the interference of plasma radiations in the CX-spectrum. Performance of the NPA during plasma discharges and experimental results on the measurement of ion-temperature have also been reported here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simultaneous measurement of nitrogen and hydrogen dissociation from vacuum ultraviolet self-absorption spectroscopy in a developing low temperature plasma at atmospheric pressure

We demonstrate a method for determining the dissociation density of N and H atoms present in a developing low temperature plasma, based on the emission and self-absorption of vacuum ultraviolet radiation produced from the plasma. Spark plasmas are produced via pulsed discharge in N{sub 2}/H{sub 2} mixtures at atmospheric pressure, where information on the dissociated densities of the constituent gas molecules is desired without employing invasive diagnostic techniques. By analyzing the self-absorption line profile of 121.5 nm Lyman-{alpha} H radiation emitted within the first {approx}1.0 mm of plasma near the anode tip, a peak dissociated H atom concentration of 5.6 Multiplication-Sign 10{sup 17} cm{sup -3} was observed {approx}100 ns into spark formation, with an estimated electron density of 2.65 Multiplication-Sign 10{sup 18} cm{sup -3} determined from Stark broadening. Similarly, simultaneous line fitting of the N 120.0/124.3 nm emission profiles revealed a peak dissociated N atom concentration of 3.8 Multiplication-Sign 10{sup 17} cm{sup -3} during the same discharge period.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Femtosecond time-resolved photoelectron spectroscopy with a vacuum-ultraviolet photon source based on laser high-order harmonic generation

A laser-based tabletop approach to femtosecond time-resolved photoelectron spectroscopy with photons in the vacuum-ultraviolet (VUV) energy range is described. The femtosecond VUV pulses are produced by high-order harmonic generation (HHG) of an amplified femtosecond Ti:sapphire laser system. Two generations of the same setup and results from photoelectron spectroscopy in the gas phase are discussed. In both generations, a toroidal grating monochromator was used to select one harmonic in the photon energy range of 20-30 eV. The first generation of the setup was used to perform photoelectron spectroscopy in the gas phase to determine the bandwidth of the source. We find that our HHG source has a bandwidth of 140 {+-} 40 meV. The second and current generation is optimized for femtosecond pump-probe photoelectron spectroscopy with high flux and a small spot size at the sample of the femtosecond probe pulses. The VUV radiation is focused into the interaction region with a toroidal mirror to a spot smaller than 100 x 100 {mu}m{sup 2} and the flux amounts to 10{sup 10} photons/s at the sample at a repetition rate of 1 kHz. The duration of the monochromatized VUV pulses is determined to be 120 fs resulting in an overall pump-probe time resolution of 135 {+-} 5 fs. We show how this setup can be used to map the transient valence electronic structure in molecular dissociation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impurity Radiation for Detecting Arcs during High Lower Hybrid Power Transmission at JET

During high power commissioning of the JET LH launcher, the radiation and impurity release has been analyzed from various diagnostics: VUV and visible spectroscopy, bolometry. These two last diagnostics have lines-of-sight viewing the launcher and can provide information about the electron and/or impurity source localisation. Using a database of 800 plasmas, it is concluded that the iron contamination (FeXV and FeXXIII) is very low for 94% of the pulses and increases linearly with LH power. During arcs, a strong and fast increase of the radiation along the line-of-sight viewing the launcher is observed. This diagnostic could provide a tool for arc detection complementary to the RF measurements aiming at reducing the metal contamination in the plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Two-photon resonant second harmonic generation in atomic xeon

Vacuum ultraviolet (VUV) radiation at 124.8 nm (9.93 eV) was produced from two-photon resonant second harmonic generation (SHG) in a xeon gaseous medium and used to probe molecular samples of acetone, furan, thiophene, ammonia, and methane. The mass spectra recorded from the species with ionization energies below 9.93 eV were dominated by the parent ions. The parent ions were only observed when the incident UV radiation was tuned to resonate with the two-photon transition 5p{sup 5}({sup 2}P{sub 3/2}{sup 0})6p[1/2]{sub 0}(leftarrow)5p{sup 6} {sup 1}S{sub 0} of Xe at 80 119.474 cm{sup -1}. The pressure dependence and the resonant nature of the parent ions observed support the mechanism for SHG as the ionization-initiated electric field induced SHG via the third-order nonlinear susceptibility {chi}{sup (3)}, which is enhanced by the coupling between the 5p{sup 5}({sup 2}P{sub 3/2}{sup 0})6p[1/2]{sub 0} and the nearby 5p{sup 5}({sup 2}P{sub 3/2}{sup 0})5d[1/2]{sub 1} states of Xe atoms.

74 ATOMIC AND MOLECULAR PHYSICS↗

Experimental investigation of the shock wave in a fast discharge with cylindrical geometry

The work is devoted to the registration and the study of the properties of cylindrical shock waves generated in the fast discharge (dI/dt ∼ 10{sup 12} A/s) inside the ceramic tube (Al{sub 2}O{sub 3}) filled by argon at pressures of 100 and 300 Pa. The shock wave appears at the inner wall of the insulator and moves to the discharge axis with a velocity of about (3−4) × 10{sup 6} cm/s with subsequent cumulation. The plasma behind the front is heated enough to produce radiation in the vacuum ultraviolet (VUV) region, which makes it possible to study its structure by means of a pinhole camera with a microchannel plate detector. The time resolution of the registration system was 10 ns. The analysis of VUV spectra of the plasma shows that the electron temperature behind the shock wave front is about several eV; after the moment of cumulation, its temperature increases to 20–30 eV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Imaging photoelectron photoion coincidence spectroscopy with velocity focusing electron optics

An imaging photoelectron photoion coincidence spectrometer at the vacuum ultraviolet (VUV) beamline of the Swiss Light Source is presented and a few initial measurements are reported. Monochromatic synchrotron VUV radiation ionizes the cooled or thermal gas-phase sample. Photoelectrons are velocity focused, with better than 1 meV resolution for threshold electrons, and also act as start signal for the ion time-of-flight analysis. The ions are accelerated in a relatively low, 40-80 V cm{sup -1} field, which enables the direct measurement of rate constants in the 10{sup 3}-10{sup 7} s{sup -1} range. All electron and ion events are recorded in a triggerless multiple-start/multiple-stop setup, which makes it possible to carry out coincidence experiments at >100 kHz event frequencies. As examples, the threshold photoelectron spectrum of the argon dimer and the breakdown diagrams for hydrogen atom loss in room temperature methane and the chlorine atom loss in cold chlorobenzene are shown and discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Vacuum-ultraviolet-induced charge depletion in plasma-charged patterned-dielectric wafers

Plasma-induced charging of patterned-dielectric structures during device fabrication can cause structural and electrical damage to devices. In this work, we report on vacuum-ultraviolet (VUV) radiation-induced charge depletion in plasma-charged patterned-silicon-oxide dielectric wafers. Charge depletion is studied as a function of photon energy and the aspect ratio of hole structures. The wafers were charged in a plasma and subsequently exposed to monochromatic-synchrotron-VUV. Surface-potential measurements after VUV exposure showed that photon energies less than 11 eV were beneficial in depleting the plasma-induced charge from the patterned-dielectric wafers. In addition, for a given photon-flux density and for photon energies less than 11 eV, VUV-induced charge depletion decreases with increasing hole aspect ratio. The results are explained with a physically plausible equivalent-circuit model, which suggests that both electron photoinjection from Si into the oxide and oxide surface conductivity play an important role in the charge-depletion process.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A new double imaging velocity focusing coincidence experiment: i{sup 2}PEPICO

The vacuum ultraviolet (VUV) beamline of the Swiss Light Source has been upgraded after two years of operation. A new, turntable-type monochromator was constructed at the Paul Scherrer Institut, which allows for fast yaw-alignment as well as quick grating change and exchange. In addition to the original imaging photoelectron photoion coincidence endstation (iPEPICO), a second, complementary double imaging setup (i{sup 2}PEPICO) has been built. Volatile samples can be introduced at room temperature or in a molecular beam, a pyrolysis source allows for radical production, and non-volatile solids can be evaporated in a heated cell. Monochromatic VUV radiation ionizes the sample and both photoelectrons and photoions are velocity map imaged onto two fast position sensitive detectors and detected in delayed coincidence. High intensity synchrotron radiation leads to ionization rates above 10{sup 5} s{sup -1}. New data acquisition and processing approaches are discussed for recording coincidence processes at high rates. The setup is capable of resolving pulsed molecular beam profiles and the synchrotron time structure temporally. The latter is shown by photoelectron autocorrelation, which displays both the 1.04 MHz ring clock frequency as well as resolving the micro-pulses with a separation of 2 ns. Kinetic energy release analysis on the dissociative photoionization of CF{sub 4} indicates a dissociation mechanism change in the Franck-Condon allowed energy range of the first ion state.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A straightforward method for Vacuum-Ultraviolet flux measurements: The case of the hydrogen discharge lamp and implications for solid-phase actinometry

Vacuum-Ultraviolet (VUV) radiation is responsible for the photo-processing of simple and complex molecules in several terrestrial and extraterrestrial environments. In the laboratory such radiation is commonly simulated by inexpensive and easy-to-use microwave-powered hydrogen discharge lamps. However, VUV flux measurements are not trivial and the methods/devices typically used for this purpose, mainly actinometry and calibrated VUV silicon photodiodes, are not very accurate or expensive and lack of general suitability to experimental setups. Here, we present a straightforward method for measuring the VUV photon flux based on the photoelectric effect and using a gold photodetector. This method is easily applicable to most experimental setups, bypasses the major problems of the other methods, and provides reliable flux measurements. As a case study, the method is applied to a microwave-powered hydrogen discharge lamp. In addition, the comparison of these flux measurements to those obtained by O{sub 2} actinometry experiments allow us to estimate the quantum yield (QY) values QY{sub 122} = 0.44 ± 0.16 and QY{sub 160} = 0.87 ± 0.30 for solid-phase O{sub 2} actinometry.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A passive measurement of dissociated atom densities in atmospheric pressure air discharge plasmas using vacuum ultraviolet self-absorption spectroscopy

We demonstrate a method for determining the dissociation degree of atmospheric pressure air discharges by measuring the self-absorption characteristics of vacuum ultraviolet radiation from O and N atoms in the plasma. The atom densities are determined by modeling the amount of radiation trapping present in the discharge, without the use of typical optical absorption diagnostic techniques which require external sources of probing radiation into the experiment. For an 8.0 mm spark discharge between needle electrodes at atmospheric pressure, typical peak O atom densities of 8.5 × 10{sup 17} cm{sup −3} and peak N atom densities of 9.9 × 10{sup 17} cm{sup −3} are observed within the first ∼1.0 mm of plasma near the anode tip by analyzing the OI and NI transitions in the 130.0–132.0 nm band of the vacuum ultraviolet spectrum.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

AlGaN/InGaN Photocathode Development

An increase in quantum efficiency in photodetectors could result in a proportional reduction in the area of atmospheric Cherenkov telescopes and an even larger reduction in cost. We report on the development of high quantum efficiency, high gain, UV/blue photon-counting detectors based on AlGaN/InGaN photocathode heterostructures grown by molecular beam epitaxy. This research could eventually result in nearly ideal light detectors with a number of distinct advantages over existing technologies for numerous applications in high-energy physics and particle astrophysics. Potential advantages include much lower noise detection, better stability and radiation resistance than other cathode structures, high VUV sensitivity and very low radioactive background levels for deep underground experiments, and high detection efficiency for the detection of individual VUV-visible photons. We are also developing photocathodes with intrinsic gain, initially improving the detection efficiency of hybrid semiconductor-vacuum tube devices and eventually leading to a new type of all-solid-state photomultiplier device.

79 ASTRONOMY AND ASTROPHYSICS↗