Search NASA⌕ Search

SEARCH · Search NASA

Results for “FARADAY EFFECT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

A graphene-based magnetoplasmonic metasurface for actively tunable transmission and polarization rotation at terahertz frequencies

The rise of terahertz (THz)-based technologies has prompted intense interest in methods for manipulating the properties of THz radiation. In this Letter, we experimentally demonstrate a graphene micro-ribbon-based metasurface that allows us to tailor and dynamically tune the transmission and polarization rotation spectra of impinging THz pulses. This is achieved by controlling the geometry of the ribbon pattern and the applied DC magnetic field, both of which strongly influence the magnetoplasmonic response of the metasurface. The properties of the metasurface can be accurately modeled using an effective medium approach that considers the capacitive interaction of the ribbons resulting from the THz electric field. Furthermore, our results highlight the promise of graphene-based THz devices that leverage the strongly enhanced light–matter interactions resulting from patterning.

36 MATERIALS SCIENCE↗

Effects of off-stoichiometry and density on the magnetic and magneto-optical properties of yttrium iron garnet films by magnetron sputtering method

Yttrium iron garnet films were deposited on Si and Si/CeO{sub 2} substrates by magnetron sputtering method followed by postannealing. By varying the fabrication parameters such as sputtering atmosphere, sputtering power, and annealing atmosphere, single phase garnet films were obtained with different off-stoichiometry and film density. The dependence of cation ratio, magnetic and magneto-optical characteristics, and absorption coefficient were systemically investigated. The results reveal that a proper oxygen pressure in both sputtering and annealing process give rise to a small cation ratio of (Fe{sup 2+} or Fe{sup 4+})/Fe{sup 3+}, thus is beneficial to obtain large saturation magnetization, large Faraday rotation, and small optical absorption. The sputtering power can also affect the properties of the film through changing the film density. Our results indicate that the properties of sputtering deposited yttrium iron garnet (YIG) film can be easily tuned and optimized by modifying the off-stoichiometry and density of the film, thus provides flexibility to fabricate YIG film for extensive applications.

36 MATERIALS SCIENCE↗

Study of magneto-optic effect on Mn{sub 1-x}Zn{sub x}Fe{sub 2}O{sub 4} nanoferrofluids

Mn{sub 1-x}Zn{sub x}Fe{sub 2}O{sub 4} nanoparticles (with x varying as 0.1, 0.3, 0.5, 0.7 and 0.9) have been synthesized by co- precipitation method using polyvinyl alcohol as surfactant. Structural analysis and surface morphology of the samples were analysed using X-ray diffraction and scanning electron microscope respectively. The Scherer approximation was used to obtain crystallite sizes and found to decrease from 8.9 nm to 4.3 nm with increase in zinc substitution. The chemical composition of samples obtained through EDAX was comparable with the initial substitutions. Saturation magnetization (M{sub s}), Remanence (M{sub r}) and Coercivity (H{sub c}) were measured using VSM at room temperature and found to decrease with increase in zinc substitution. Verdet constant of the samples are obtained from Faraday rotation for various magnetic fields and it varies from 18 × 10{sup −4} to 3 × 10{sup −4}deg/Gcm with zinc substitution.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Compact Polarimetry in a Low Frequency Spaceborne Context

Compact polarimetry has been shown to be an interesting alternative mode to full polarimetry when global coverage and revisit time are key issues. It consists on transmitting a single polarization, while receiving on two. Several critical points have been identified, one being the Faraday rotation (FR) correction and the other the calibration. When a low frequency electromagnetic wave travels through the ionosphere, it undergoes a rotation of the polarization plane about the radar line of sight for a linearly polarized wave, and a simple phase shift for a circularly polarized wave. In a low frequency radar, the only possible choice of the transmit polarization is the circular one, in order to guaranty that the scattering element on the ground is illuminated with a constant polarization independently of the ionosphere state. This will allow meaningful time series analysis, interferometry as long as the Faraday rotation effect is corrected for the return path. In full-polarimetric (FP) mode, two techniques allow to estimate the FR: Freeman method using linearly polarized data, and Bickel and Bates theory based on the transformation of the measured scattering matrix to a circular basis. In CP mode, an alternate procedure is presented which relies on the bare surface scattering properties. These bare surfaces are selected by the conformity coefficient, invariant with FR. This coefficient is compared to other published classifications to show its potential in distinguishing three different scattering types: surface, doublebounce and volume. The performances of the bare surfaces selection and FR estimation are evaluated on PALSAR and airborne data. Once the bare surfaces are selected and Faraday angle estimated over them, the correction can be applied over the whole scene. The algorithm is compared with both FP techniques. In the last part of the paper, the calibration of a CP system from the point of view of classical matrix transformation methods in polarimetry is proposed.

radar polarization diversity↗

Multi-nuclide AMS system at the University of Tsukuba

A multi-nuclide AMS system on the 12UD Pelletron tandem accelerator at the University of Tsukuba (Tsukuba AMS system) can measure environmental levels of long-lived radioisotopes of {sup 14}C, {sup 26}Al, {sup 36}Cl and {sup 129}I by employing a molecular pilot beam. AMS is an ultrasensitive technique for the study of long-lived radioisotopes, and stable isotopes at very low abundances. The high terminal voltage has an advantage in the detection of heavy radioisotopes. Much progress has been made in the development of new AMS techniques. For example, a standard deviation of the fluctuation for the {sup 36}Cl/Cl ratio is +- 2%, and the effective detection limit is better than 1x10{sup -15}. In recent years, the main research field of the 12UD Pelletron tandem accelerator has shifted to accelerator mass spectrometry (AMS) research from nuclear physics. This report presents an overview of the Tsukuba AMS system.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Laser-driven relativistic electron beam interaction with solid dielectric

The multi-frames shadowgraphy, interferometry and polarimetry diagnostics with sub-ps time resolution were used for an investigation of ionization wave dynamics inside a glass target induced by laser-driven relativistic electron beam. Experiments were done using the 50 TW Leopard laser at the UNR. For a laser flux of {approx}2 Multiplication-Sign 10{sup 18}W/cm{sup 2} a hemispherical ionization wave propagates at c/3. The maximum of the electron density inside the glass target is {approx}2 Multiplication-Sign 10{sup 19}cm{sup -3}. Magnetic and electric fields are less than {approx}15 kG and {approx}1 MV/cm, respectively. The electron temperature has a maximum of {approx}0.5 eV. 2D interference phase shift shows the 'fountain effect' of electron beam. The very low ionization inside glass target {approx}0.1% suggests a fast recombination at the sub-ps time scale. 2D PIC-simulations demonstrate radial spreading of fast electrons by self-consistent electrostatic fields.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

EVOLUTION AND DISTRIBUTION OF MAGNETIC FIELDS FROM ACTIVE GALACTIC NUCLEI IN GALAXY CLUSTERS. I. THE EFFECT OF INJECTION ENERGY AND REDSHIFT

We present a series of cosmological magnetohydrodynamic simulations that simultaneously follow the formation of a galaxy cluster and evolution of magnetic fields ejected by an active galactic nucleus (AGN). Specifically, we investigate the influence of both the epoch of the AGN (z {approx} 3-0.5) and the AGN energy ({approx}3 x 10{sup 57}- 2 x 10{sup 60} erg) on the final magnetic field distribution in a relatively massive cluster (M{sub vir} {approx} 10{sup 15} M{sub sun}). We find that as long as the AGN magnetic fields are ejected before the major mergers in the cluster formation history, magnetic fields can be transported throughout the cluster and can be further amplified by the intracluster medium (ICM) turbulence caused by hierarchical mergers during the cluster formation process. The total magnetic energy in the cluster can reach {approx}10{sup 61} erg, with micro Gauss fields distributed over the {approx}Mpc scale. The amplification of the total magnetic energy by the ICM turbulence can be significant, up to {approx}1000 times in some cases. Therefore even weak magnetic fields from AGNs can be used to magnetize the cluster to the observed level. The final magnetic energy in the ICM is determined by the ICM turbulent energy, with a weak dependence on the AGN injection energy. We discuss the properties of magnetic fields throughout the cluster and the synthetic Faraday rotation measure maps they produce. We also show that high spatial resolution over most of the magnetic regions of the cluster is very important to capture the small-scale dynamo process and maintain the magnetic field structure in our simulations.

79 ASTRONOMY AND ASTROPHYSICS↗

An assessment of generating quasi-static magnetic fields using laser-driven “capacitor” coils

Over the previous decade, numerous experiments have been performed using a laser to drive a strong, quasi-static magnetic field. Field strength and energy density measurements of these experiments have varied by many orders of magnitude, painting a confusing picture of the effectiveness of these laser-driven coils (LDCs) as tools for generating consistent fields. At the higher end of the field energy spectrum, kilotesla field measurements have been used to justify future experimental platforms, theoretical work, and inertial confinement fusion concepts. In this paper, we present the results from our own experiments designed to measure magnetic fields from LDCs as well as a review of the body of experiments that have been undertaken in this field. Here, we demonstrate how problems with prior diagnostic analyses have led to overestimations of the magnetic fields generated from LDCs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Status of NIO1 construction

The NIO1 (Negative Ion Optimization phase 1) project consists of a multiaperture negative ion source mounted on a 60 kV accelerating column; up to 9 beamlets (15 mA H{sup -} each one) arranged in 3x3 matrix with 14 mm spacing can be extracted. The moderate size and the modular concept make some relative rotation of the source magnetic filter and the electrodes possible, so that the effect of crossed and aligned field can be easily compared. Other goals of source experimental program are emittance (and beam profile) measurement at several distances (for simulation code validation), testing of diagnostic components and of radiofrequency coupling. A full set of construction drawing was completed; also the Fast Emittance Scanner (FES) and its vacuum chambers were built (four mounting positions are reserved to FES). Some low power rf matching boxes were developed for a test plasma, approximately half the source size. A cesium oven compatible with NIO1 is being also developed; by using some industrial standard 100 W heaters (with a proper driver) a careful control of temperature is planned.

43 PARTICLE ACCELERATORS↗

Study of magneto-optical characteristics of cerium incorporated yttrium iron garnet films

Highlights: • Ce:YIG films deposited by sol–gel method. • XRD results shows crystallite size of films decreases by Ce concentrations. • Morphological studies indicate of smooth and connected surface for all films. • Ce ions increased Faraday rotation of YIG films. - Abstract: In the current study, yttrium iron garnet films incorporated with cerium with the general formula of Ce{sub x}Y{sub 3-x}Fe{sub 5}O{sub 12} and values of (x = 0, 0.1, 0.3, 0.5, 0.7) were prepared through sol–gel method using spin coating technique and heating treatment on quartz substrates. Prepared samples were studied to check physical characteristics. X-ray diffraction analysis (XRD), scanning electron microscope (SEM), atomic force microscope (AFM) and vibrating sample magnetometer (VSM) were applied to study the impact of Ce impurities on the structural characteristic, surface morphology of films and magnetic properties, respectively. Faraday rotation values of samples were measured at the wavelength of 632 nm. The image of the atomic force microscope (AFM) of the prepared samples shows that the films have a continuous and smooth surface.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Rotating Alfvén waves in rotating plasmas

Angular momentum coupling between a rotating magnetized plasma and torsional Alfvén waves carrying orbital angular momentum (OAM) is examined. It is demonstrated not only that rotation is the source of Fresnel–Faraday rotation – or orbital Faraday rotation effects – for OAM-carrying Alfvén waves, but also that angular momentum from an OAM-carrying Alfvén wave can be transferred to a rotating plasma through the inverse process. For the direct process, the transverse structure angular rotation frequency is derived by considering the dispersion relation for modes with opposite OAM content. For the inverse process, the torque exerted on the plasma is derived as a function of wave and plasma parameters.

Physics↗

Continuous Simultaneous Detection in Mass Spectrometry

In mass spectrometry, several advantages can be derived when multiple mass-to-charge values are detected simultaneously. One such advantage is an improved duty cycle, which leads to superior limits of detection, better precision, shorter analysis times, and reduced sample sizes. A second advantage is the ability to reduce correlated noise by taking the ratio of two or more simultaneously collected signals, enabling greatly enhanced isotope ratio data. A final advantage is the elimination of spectral skew, leading to more accurate transient signal analysis. Here, these advantages are demonstrated by means of a novel Faraday-strip array detector coupled to a Mattauch-Herzog mass spectrograph. The same system is used to monitor elemental fractionation phenomena in laser ablation inductively coupled plasma mass spectrometry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Very Long Baseline polarimetry and the γ -ray connection in Markarian 421 during the broadband campaign in 2011

Context. This is the third paper in a series devoted to the analysis of the multiwavelength data from a campaign on the nearby (z = 0.03) TeV blazar Mrk 421 during 2011. Aims. In this study, we investigate the structure of the high angular resolution polarization, the magnetic topology, the total intensity light curve, the γ-ray flux, and the photon index. We describe how they evolve and how they are connected. Methods. We analyzed data in polarized intensity obtained with the Very Long Baseline Array (VLBA) at twelve epochs (one observation per month from January to December 2011) at 15, 24, and 43 GHz. For the absolute orientation of the electric vector position angles (EVPA) we used the D-terms method; we also confirm its accuracy. We also used γ-ray data from the Fermi Large Area Telescope on weekly time bins throughout 2011. Results. The source shows polarized emission, and its properties vary with time, frequency, and location along the jet. The core mean polarization fraction is generally between 1% and 2%, with a 4% peak at 43 GHz in March; the polarization angle is variable, mainly at 15 GHz, where it changes frequently, and less so at 43 GHz, where it oscillates in the range 114°-173°. The jet polarization properties are more stable, with a fractional polarization of around 16% and a polarization angle nearly perpendicular to the jet axis. The average flux and photon index at γ-ray energies are (17.4 ± 0.5) × 10 -8 ph cm -2 s -1 and Γ = 1.77 ± 0.02. The γ-ray light curve shows variability, with a main peak of (38 ± 11) × 10 -8 ph cm -2 s -1 at the beginning of March and two later peaks centered on September 8 and November 13. The first γ-ray peak appears to be associated with the peak in the core polarized emission at 43 GHz, as well as with the total intensity light curve. A discrete correlation function analysis yields a correlation coefficient of 0.54 at zero delay, with a significance level >99.7%. Conclusions. With this multifrequency study, we accurately determine the polarization properties of Mrk 421, both in the core and in the jet region. The radio and γ-ray light curves are correlated. The observed EVPA variability at 15 GHz is partly due to opacity and partly to a variable Faraday rotation effect. Finally, to explain the residual variability of the intrinsic polarization angle and the low degree of polarization in the core region, we invoke a blend of variable cross-polarized subcomponents with different polarization properties within the beam.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of gas pulsing system for electron cyclotron resonance ion source

A gas-pulsing system for an electron cyclotron resonance ion source with all permanent magnets (Kei2 source) at NIRS has been developed and tested. The system consists of a small vessel (30 ml) to reserve CH{sub 4} gas and two fast solenoid valves that are installed at both sides of the vessel. They are connected to each other and to the Kei2 source by using a stainless-steel pipe (4 mm inner diameter), where the length of the pipe from the valve to the source is 60 cm and the conductance is 1.2 l/s. From the results of the test, almost 300 e {mu}A for a pulsed {sup 12}C{sup 4+} beam was obtained at a Faraday cup in an extraction-beam channel with a pressure range of 4000 Pa in the vessel. At this time, the valve has an open time of 10 ms and the delay time between the valve open time and the application of microwave power is 100 ms. In experiments, the conversion efficiency for input CH{sub 4} molecules to the quantity of extracted {sup 12}C{sup 4+} ions in one beam pulse was found to be around 3% and the ratio of the total amount of the gas requirement was only 10% compared with the case of continuous gas provided in 3.3 s of repetition in HIMAC.

43 PARTICLE ACCELERATORS↗

Development of laser-aided plasma diagnostics and related technology

Laser-aided plasma diagnostics, aiming for establishment of reliable density measurement in next step magnetically confined fusion devices, are under development at the National Institute for Fusion Science. A new type of two color laser (57.2/47.6-{mu}m CH{sub 3}OD) interferometer has been developed and its original function, vibration subtraction, was confirmed in a test stand. The line integrated density measurements by the polarimeter were demonstrated at Compact Helical System by the Cotton-Mouton polarimeter and at the LHD by the Faraday rotation polarimeter.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetic Field Measurements in Wire-Array Z-Pinches using Magneto-Optically Active Waveguides

Understanding the magnetic field topology in wire-array Z-pinches as a function of time is of great significance to understanding these high-energy density plasmas especially for their ultimate application to stockpile stewardship and inertial confinement fusion. We are developing techniques to measure magnetic fields as a function of space and time using Faraday rotation of a single longitudinal mode (SLM) laser through a magneto-optically active bulk waveguide (multicomponent terbium borate glass) placed adjacent to, or within, the wire array in 1 MA experiments. We have measured fields >10 T with 100 ns rise times outside of a wire-array for the entire duration of the current pulse and as much as {approx}2 T inside a wire-array for {approx}40 ns from the start of current. This is the first time that such rapidly varying and large fields have been measured using these materials. In a dense Z-pinch, these sensing devices may not survive for long but may provide the magnetic field at the position of the sensor that can be used to corroborate magnetic probes, with which we compare our results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sputtering yields of Ru, Mo, and Si under low energy Ar{sup +} bombardment

Ion sputtering yields for Ru, Mo, and Si under Ar{sup +} ion bombardment in the near-threshold energy range have been studied using an in situ weight-loss method with a Kaufman ion source, Faraday cup, and quartz crystal microbalance. The results are compared to theoretical models. The accuracy of the in situ weight-loss method was verified by thickness-decrease measurements using grazing incidence x-ray reflectometry, and results from both methods are in good agreement. These results provide accurate data sets for theoretical modeling in the near-threshold sputter regime and are of relevance for (optical) surfaces exposed to plasmas, as, for instance, in extreme ultraviolet photolithography.

36 MATERIALS SCIENCE↗

High-sensitive scanning laser magneto-optical imaging system

A high-sensitive scanning laser magneto-optical (MO) imaging system has been developed. The system is mainly composed of a laser source, galvano meters, and a high-sensitive differential optical-detector. Preliminary evaluation of system performance by using a Faraday indicator with a Faraday rotation coefficient of 3.47x10{sup -5} rad/{mu}m Oe shows a magnetic sensitivity of about 5 {mu}T, without any need for accumulation or averaging processing. Using the developed MO system we have succeeded in the fast and quantitative imaging of a rotationally symmetric magnetic field distribution around an YBa{sub 2}Cu{sub 3}O{sub 7-{delta}} (YBCO) strip line applied with dc-biased current, and also succeeded in the detection of quantized fine signals corresponding to magnetic flux quantum generation in a superconducting loop of an YBCO Josephson vortex flow transistor. Thus, the developed system enables us not only to do fast imaging and local signal detection but also to directly evaluate both the strength and direction of a magnetic signal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗