Orbiter integrated active thermal control subsystem test

Integrated subsystem level testing of the systems within the orbiter active thermal chamber capable of simulating ground, orbital, and entry temperature and pressure profiles. The test article was in a closed loop configuration that included flight type and functionally simulated protions of all ATCS components for collecting, transporting, and rejecting orbiter waste heat. Specially designed independently operating equipment simulated the transient thermal input from the cabin, payload, fuel cells, freon cold plates, hydraulic system, and space environment. Test team members using data, controls, and procedures available to a flight crew controlled the operation of the ATCS. The ATCS performance met or exceeded all thermal and operational requirements for planned and contingency mission support.

Jaax, J. R.↗

Thermal vacuum performance testing of the Space Shuttle Orbiter radiator system

A space shuttle orbiter system thermal vacuum performance test was conducted at NASA-Johnson Space Center in Chamber A of the space environment simulation laboratory. The test of objective was to verify the radiator system heat rejection performance capability utilizing two development and two flight radiator panels comprising one of the two Orbiter Freon-21 coolant loops. Radiator performance over the range of expected flight conditions was as predicted, and there was no degradation of performance after extended vacuum exposure.

Behrend, A. F., Jr.↗

Ice/frost detection using millimeter wave radiometry

A series of ice detection tests was performed on the shuttle external tank (ET) and on ET target samples using a 35/95 GHz instrumentation radiometer. Ice was formed using liquid nitrogen and water spray inside a test enclosure containing ET spray on foam insulation samples. During cryogenic fueling operations prior to the shuttle orbiter engine firing tests, ice was formed with freon and water over a one meter square section of the ET LOX tank. Data analysis was performed on the ice signatures, collected by the radiometer, using Georgia Tech computing facilities. Data analysis technique developed include: ice signature images of scanned ET target; pixel temperature contour plots; time correlation of target data with ice present versus no ice formation; and ice signature radiometric temperature statistical data, i.e., mean, variance, and standard deviation.

Gagliano, J. A.↗

A system for model access in tunnels with an unbreathable test medium

In many specialty wind tunnels, test gases other than ambient air are used to meet special testing requirements. A typical example is the use of freon as the test gas to achieve a realistic density ratio between gas and model for exploring flutter stability boundaries. Another example is the use of pressurized air to elevate the stream density and enhance Reynolds number or dynamic pressure simulation. Such specialty tunnels require a system of access o the model which will allow services and changes to the model without exposing personnel to the unnatural and perhaps hostile environment or requiring the venting and purging of the entire tunnel circuit. This paper will describe the plenum and model access systems for the forthcoming U.S. National Transonic facility where gaseous nitrogen (N2) at temperatures between 338 and 78 K and at pressures to 9 bars is used as the test medium. The operation at cold temperatures imposes some additional requirements which make the access systems more difficult to design and time consuming to operate than for conventional wind tunnels.

Howell, R. R.↗

A measurement of the relativistic rise in xenon-filled ionisation chambers for cosmic ray iron

The relativistic rise of ionization in a pair of xenon-filled pulse ion chambers was measured for primary iron nuclei during a recent balloon flight. Energy calibration over the range 21.5-60 GeV/n was made with a Freon-12 gas Cerenkov detector. This allowed a comparison with recent calculations of the relativistic rise in xenon counters and an estimate of the ion chamber resolution above 21.5 GeV/n to be made.

Gregory, J. C.↗

Two-phase flow and heat transfer under low gravity

Spacelab experiment to investigate two-phase flow patterns under gravity uses a water-air mixture experiment. Air and water are circulated through the system. The quality or the mixture or air-water is controlled. Photographs of the test section are made and at the same time pressure drop across the test section is measured. The data establishes a flow regime map under reduced gravity conditions with corresponding pressure drop correlations. The test section is also equipped with an electrical resistance heater in order to allow a flow boiling experiment to be carried out using Freon II. High-speed photographs of the test section are used to determine flow patterns. The temperature gradient and pressure drop along the duct can be measured. Thus, quality change can be measured, and heat transfer calculated.

Walter Frost↗

The mechanical design of a vapor compressor for a heat pump to be used in space

A heat pump developed for use in Spacelab as a stand-alone refrigeration unit as well as within a fluid loop system is discussed. It will provide an active thermal control for payloads. Specifications for the heat pump were established: (1) heat removal rates at the source; (2) heat source temperatures from room temperature; (3) heat-sink fluid temperatures at condenser inlet; and (4) minimum power consumption. A reversed Carnot cycle heat pump using Freon 12 as working fluid incorporating a one-cylinder reciprocating compressor was selected. The maximum crankshaft speed was fixed relatively high at 100 rpm. The specified cooling rates then made it necessary to select a cylinder volume of 10 cu cm, which was obtained with a bore of 40 mm and a stroke of 8 mm.

Berner, F.↗

Investigation of spray characteristics for flashing injection of fuels containing dissolved air and superheated fuels

The flow, atomization and spreading of flashing injector flowing liquids containing dissolved gases (jet/air) as well as superheated liquids (Freon II) were considered. The use of a two stage expansion process separated by an expansion chamber, ws found to be beneficial for flashing injection particularly for dissolved gas systems. Both locally homogeneous and separated flow models provided good predictions of injector flow properties. Conventional correlations for drop sizes from pressure atomized and airblast injectors were successfully modified, using the separated flow model to prescribe injector exit conditions, to correlate drop size measurements. Additional experimental results are provided for spray angle and combustion properties of sprays from flashing injectors.

Solomon, A. S. P.↗

Aeroelasticity matters - Some reflections on two decades of testing in the NASA Langley Transonic Dynamics Tunnel

In 1955, work was started on the conversion of a subsonic wind tunnel to a 16-foot transonic tunnel with Freon-12 or air as the test medium. The new facility, designated the Transonic Dynamics Tunnel (TDT), became fully operational in 1960. A description is presented of aeroelastic testing and research performed in the TDT since 1960. It is pointed out that wind-tunnel tests of aeroelastic models require specialized experimental techniques seldom found in other types of wind-tunnel studies. Attention is given to model mount systems, launch vehicle models, aircraft models, aircraft buffet, gust response, stability derivative measurements, and subcritical testing techniques. Aspects of vehicle development testing are considered along with aeroelastic 'fixes', aeroelastic 'surprises', approaches for controlling aeroelastic effects, and unsteady pressure measurements.

Reed, W. H., III↗

Atomization and combustion properties of flashing injectors

Flashing injection involves expanding a fluid through an injector until a supersaturated state is reached, causing a portion of the fluid to flash to a vapor. This investigation considered the flow, atomization and spreading properties of flashing injectors flowing liquids containing dissolved gases (Jet A/air) as well as superheated liquids (Freon 11). The use of a two stage expansion process, separated by an expansion chamber, was found to be beneficial for good atomization properties of flashing injection - particularly for dissolved gas systems. Both locally homogeneous and separated flow models provided good predictions of injector flow properties. Conventional correlations for drop sizes from pressure atomized and airblast injectors were successfully modified, using the separated flow model to prescribe injector exit conditions, to correlate drop size measurements. Additional experimental results are provided for spray angle and combustion properties of sprays from flashing injectors.

Solomon, A. S. P.↗

Cosmic ray detector for high energy iron nuclei

An experiment to directly measure the differential energy spectra of nuclei with charge between 15-28 inclusive with a balloon borne instrument is presented. A High Energy Gas Cerenkov Spectrometer (HEGCS) is described, and consists of a 3 m diam drum 4.5 m tall containing three light diffusion chambers. A hodoscopic array of scintillators emit light into the top and bottom light chambers which serve for track recordings of the trajectory and charge of incident cosmic rays. A center chamber pressure vessel, the HEGCS, has a 4.0 m sr and a threshold of 50 GeV/amu. The hexagonal array scintillators have 24 elements/array feeding photomultiplier tubes at the vertices between the scintillators, with other PMTs located around the top and bottom chambers to capture escaped scintillator light. The HEGCS is filled with freon-12, with reflective paint on the inner surface to convert UV Cerenkov photons into visible photons near 425 nm.

Streitmatter, R. E.↗

Static and unsteady pressure measurements on a 50 degree clipped delta wing at M = 0.9

Static and unsteady pressures were measured on a 50.45 degree clipped delta wing in the Langley Transonic Dynamics Tunnel with Freon as the test medium. Data taken at M = 0.9 is presented for static and oscillatory deflections of the trailing edge control surface and for the wing in pitch. Comparisons of the static measured data are made with results computed using the Bailey-Ballhaus small disturbance code.

Hess, R. W.↗

General Maneuver Program

General Maneuver Program, GMAN, computes both orbital and spin-axis reorientation maneuver parameters for various spacecraft. Specifically, GMAN computes detailed maneuver scenarios necessary to achieve desired orbit and attitude maneuvers. Program supports both spinning and inertially-fixed despun spacecraft and includes modeling for either hydrazine or Freon propulsion system.

Erickson, J. A.↗

A high-Reynolds-number seal test facility: Facility description and preliminary test data

A facility has been developed for testing the leakage and rotordynamic characteristics of interstage-seal configurations for the HPFTP (High Pressure Fuel Turbopump) of the SSME (Space Shuttle Main Engine). Axial Reynolds numbers on the order of 400,000 are realized in the test facility by using a Dupont freon fluid called Halon (CBrF3). The kinematic viscosity of Halon is of the same order as the liquid hydrogen used in the HPFTP. Initial testing has focused on the current flight configurations (a three-segment, stepped unit) and a convergent-taper candidate.

Childs, D. W.↗

Second order closure for variable density free shear layer

A full second order closure turbulence model for the prediction of free shear flows with variable density is developed. The importance of density fluctuations due to inhomogeneities in fluid composition is emphasized. Some simplicity is achieved by using density weighted averaging to account implicitly for density fluctuation effects. Transport equations for various second order correlations - such as Reynolds stress, turbulent mass fluxes or density velocity correlations - are derived, modelled and solved, together with the mean equations for momentum and species conservation. Solutions of these equations are compared with the two different sets of experimental data for low speed free mixing layers (helium into nitrogen and freon 12 into air).

Vandromme, D.↗

Design and development of Shuttle Get-Away-Special experiment G-0074

An experiment to investigate more versatile, lower cost surface tension propellant acquisition approaches for future satellite and spacecraft propellant tanks is designed to demonstrate a propellant off-load capability for a full-tank gallery surface tension device, such as that employed in the shuttle reaction control subsystem, and demonstrate a low-cost refillable trap concept that could be used in future orbit maneuver propulsion systems for multiple engine restarts. A Plexiglas test tank, movie camera and lights, auxiliary liquid accumulator, control electronics, battery pack, and associated valving and plumbing are used. The test liquid is Freon 113, dyed blue for color movie coverage. The fully loaded experiments weighs 106 pounds and is to be installed in a NASA five-cubic-foot flight canister. Vibration tests, acoustic tests, and high and low temperature tests were performed to quality the experiment for flight.

Orton, G. F.↗

Analytic modeling of a spray diffusion flame

A detailed model for a spray diffusion flame is described. The model is based on the boundary layer form of the equations of motion, with droplet transport accounted for using a discretized droplet size distribution function. Interphase transport of mass and energy are accounted for, with a flame-sheet model used to describe the combustion process on a droplet scale. Near dynamic equilibrium is assumed for the description of droplet transport; droplets can diffuse relative to the gas phase. Gas-phase mixing is accounted for using a two-equation turbulence model; buoyancy effects are included, with a temperature fluctuation equation used to account for buoyancy effects on turbulence structure. Thermal radiation from gas-phase CO2 and H2O is included. Gas-phase chemical kinetics are modeled using a 20-reaction, 10-species version of the advanced quasi-global chemical kinetics formulation. Results are compared with data for a vaporizing Freon spray and a pentane spray flame. It is shown that the computational approach provides a reasonably valid picture of the overall development of a spray diffusion flame, and, furthermore, provides a useful tool for the parametric examination of the spray combustion process.

Harsha, P. T.↗