Search NASA⌕ Search

SEARCH · Search NASA

Results for “FREQUENCY STANDARD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Gravitational Wave Search With the Clock Mission

Doppler tracking of distant spacecraft is the only method currently available to search for gravitational waves in the low-frequency (~0.0001-0.1 Hz) band. Suppose that the Clock Mission spacecraft is transferred into a suitable interplanetary orbit, I discuss here how the on-board frequency standard could be employeed with an all-Ka-band radio system using the very high stability Deep Space Network station DSS 25 being instrumented for Cassini. With this configuration, the Clock Mission could search for gravitational waves at a sensitivity limited by the frequency standards, rather than plasma or tropospheric scintillation effects, whenever the sun-earth-spacecraft angle is greater than 90 degrees.

Clock↗

The future of time and frequency dissemination

I will try to extrapolate the changes in the dissemination of time and frequency information that have taken place during the last 25 years to predict the future developments both in the methods of disseminating time and frequency and in the kinds of customers we will be asked to serve. Two important developments are likely to play pivotal roles in driving the evolution of dissemination. The first is the commercial availability of very high quality clocks -- devices whose performance may eventually rival that of the current generation of primary frequency standards. The widespread use of these devices may blur the traditional distinction between client and server, and may replace it with a more symmetrical interchange of data among peers. The second is the increasing demand for digital time and frequency information driven by the increasing sophistication of everything from traffic lights to electric power meters. The needs of these individual users may not tax the state of the art of primary frequency standards in principle, but their large numbers and wide geographical distribution present a technological challenge that is difficult to meet at a reasonable price using existing methods. Some of these problems may be solved (or at least addressed) using developments in communications and consumer electronics such as the increasing use of fiber-optic telephone circuits and the increasing bandwidth and sophistication of the cable network used to transmit television pictures. To be useful, these advances in hardware must stimulate parallel advances in software algorithms and methods. These advances are more difficult to predict with great confidence, but the developments of the last few years will be examined to provide some indications of the future.

Levine, Judah↗

Stabilized Fiber-Optic Distribution of Reference Frequency

An optoelectronic system distributes a reference signal of low noise and highly stabilized phase and frequency (100 MHz) from an atomic frequency standard to a remote facility at a distance up to tens of kilometers. The reference signal is transmitted to the remote station as amplitude modulation of an optical carrier signal propagating in an optical fiber. The stabilization scheme implemented in this system is intended particularly to suppress phase and frequency fluctuations caused by vibrations and by expansion and contraction of the optical fiber and other components in diurnal and seasonal heating and cooling cycles. The system (see figure) comprises several subsystems, the main one being (1) a hydrogen-maser or linear-ion-trap frequency standard in an environmentally controlled room in a signal-processing center (SPC), (2) a stabilized fiber-optic distribution assembly (SFODA), (3) a compensated sapphire oscillator (CSO) in an environmentally controlled room in the remote facility, (4) thermally stabilized distribution amplifiers and cabling from the environmentally controlled room to end users, and (5) performance- measuring equipment.

Calhoun, Malcolm↗

SVN 9 End-Of-Life testing

SVN 9 was a GPS Block I research and development satellite. When it was launched in Jun. 1984, questions regarding the future performance of atomic frequency standards in orbit remained to be answered. In Mar. 1994, after performing for twice its designed life span, SVN 9 was deactivated as a member of the operational GPS satellite constellation. During the next two months, U.S. Air Force and Rockwell personnel performed various tests to determine just how well the atomic frequency standards had withstood ten years in the space environment. The results of these tests are encouraging. With a full constellation of Block II/IIA satellites on orbit, as well as the anticipated launch of the Block IIR satellites, results from the end of life testing will be helpful in assuring the continued success of the GPS program.

Hatten, Gregory E.↗

Integrity Monitoring of Mercury Discharge Lamps

Mercury discharge lamps are critical in many trapped ion frequency standard applications. An integrity monitoring system can be implemented using end-of-life signatures observed in operational mercury discharge lamps, making it possible to forecast imminent failure and to take action to mitigate the consequences (such as switching to a redundant system). Mercury lamps are used as a source of 194-nm ultraviolet radiation for optical pumping and state selection of mercury trapped ion frequency standards. Lamps are typically fabricated using 202Hg distilled into high-purity quartz, or other 194-nm transmitting material (e.g., sapphire). A buffer gas is also placed into the bulb, typically a noble gas such as argon, neon, or krypton. The bulbs are driven by strong RF fields oscillating at .200 MHz. The lamp output may age over time by two internal mechanisms: (1) the darkening of the bulb that attenuates light transmission and (2) the loss of mercury due to migration or chemical interactions with the bulb surface. During fabrication, excess mercury is placed into a bulb, so that the loss rate is compensated with new mercury emanating from a cool tip or adjacent reservoir. The light output is nearly constant or varies slightly at a constant rate for many months/years until the mercury source is depleted. At this point, the vapor pressure abruptly falls and the total light output and atomic clock SNR (signal-to-noise ratio) decrease. After several days to weeks, the light levels decrease to a point where the atomic clock SNR is no longer sufficient to stay in lock, or the lamp self-extinguishes. This signature has been observed in four separate end-of-life lamp failures while operating in the Deep Space Network (DSN). A simple integrator circuit can observe and document steady-state lamp behavior. When the light levels drop over a predetermined time interval by a specified amount (e.g., 20 percent), an alarm is set. For critical operational applications, such as the DSN or in space flight, this warning provides notice that a failure may be imminent, and for operators or control algorithm to take action.

Tjoelker, Robert L.↗

Stabilized fiber-optic frequency distribution system

A technique for stabilizing reference frequencies transmitted over fiber-optic cable in a frequency distribution system is discussed. The distribution system utilizes fiber-optic cable as the transmission medium to distribute precise reference signals from a frequency standard to remote users. The stability goal of the distribution system is to transmit a 100-MHz signal over a 22-km fiber-optic cable and maintain a stability of 1 part in 10(17) for 1000-second averaging times. Active stabilization of the link is required to reduce phase variations produced by environmental effects, and is achieved by transmitting the reference signal from the frequency standard to the remote unit and then reflecting back to the reference unit over the same optical fiber. By comparing the phase of the transmitted and reflected signals at the reference unit, phase variations of the remote signal can be measured. An error voltage derived from the phase difference between the two signals is used to add correction phase.

Primas, L. E.↗

An improved linear ion trap physics package

This article describes an improvement in the architecture of the physics package used in the Linear Ion Trap (LIT)-based frequency standard recently developed at JPL. This new design is based on the observation that ions can be moved along the axis of an LIT by applied dc voltages. The state selection and interrogation region can be separated from the more critical microwave resonance region where the multiplied local oscillator signal is compared with the stable atomic transition. This separation relaxes many of the design constraints of the present units. Improvements include increased frequency stability and a substantial reduction in size, mass, and cost of the final frequency standard.

Prestage, J. D.↗

A rubidium clock for SEEK-TALK

The development of a tactical rubidium frequency standard (TRFS) for the SEEK-TALK program is discussed. This effort, which is entering the prototype stage, is directed toward the establishment of a production capability for miniature rubidium clocks of medium stability capable of fast warmup and extreme ruggedness for military avionics applications. The overall unit consists of an ultraminiature physics package and four plug-in circuit boards inside a 2 1/2-inch square by 4-inch box. This size is achieved without the extensive use of hybrid microcircuitry, yet is believed to be the smallest atomic frequency standard yet developed.

Riley, W. J.↗

Light shift measurements in a Cesium Fountain without the use of mechanical shutters

We present measurements confirming operation of a cesium fountain frequency standard with light shift below 10^-15 (and with evidence suggesting it is several orders of magnitude below this level) but without the use of mechanical shutters. Suppression of the light shift is realized using a master-slave laser configuration by reducing the overall optical power delivered to the physics package as well as spoiling the injection of the slave, causing it to lase far off resonance (1-2 nm) as proposed by the authors several years ago [l]. In the absence of any mitigation, this (AC Stark) shift, due to near-resonant laser light reaching the atoms during their microwave interrogation period, is the largest shift in such frequency standards (2x10^-11 for Our fountain). Mechanical shutters provided adequate light attenuation but have been prone to failure.

light shift measurements↗

Reduction of quantization error in measurement of frequency

Method reduces quantization errors using new digital circuit. Circuit provides very high resolution (10 to the minus 2nd power to 10 to the minus 3rd power Hz) without high-speed counters. It lends itself to microminaturization and is simple to construct. Unknown frequency is compared to standard frequency by means of zero-crossing coincidence-detecting circuit.

Nossen, E. J.↗

Precision timekeeping using a small passive hydrogen maser

The timekeeping ability of a prototype passive hydrogen maser which is a factor of 5 smaller in size, weight, and cost than any previously designed, was compared to UTC (NBS) based on 10 cesium frequency standards including a large primary standard, NBS-4. The frequency of the prototype was monitored as a function of source pressure, cavity temperature, microwave power, modulation width, and magnetic field. Based on these measurements, a frequency stability of better than 6 x 10 to the -15 power was expected, implying a timekeeping ability of order 0.5 ns/day. Measurements vs UTC(NBS) indicate a joint timekeeping a stability of order 1.2 ns/day. Simultaneous measurements made between NBS-4, UTC(6600), and the small passive me maser show peak to peak time variations of the small maser vs UTC(6600) was 10 ns for the full 32 days if the average rate and drift are considered. Frequency stability of the small prototype vs UTC (NBS) was to 1.1 x 10 to the -14th power for tau = 1 to 8 days.

Walls, F. L.↗

Far infrared laser frequencies of CH3OD and N2H4

The frequencies of 26 laser lines with wavelengths between 57 and 534 microns are measured in the optically pumped laser gases CH3OD and N2H4. A pair of 12CO2 lasers are employed as a frequency standard for the heterodyne frequency measurements. As the measurements are oriented toward spectroscopic applications of FIR lasers where dense, broad, frequency coverage is essential, every strong pump absorption of the two molecules for new lines that might be made to lase by varying the laser gas pressure and the tuning of the pump laser are investigated.

Radford, H. E.↗

Cesium standard for satellite application

A Cesium frequency standard that was developed for satellite applications is discussed. It weighs 23 lbs. and uses 23.5 watts of power, achieves a stability of 1 x ten to the minus 13th power/100,000 seconds, and is radiation hardened. To achieve the weight and reliability requirements, both thick and thin film hybrid circuits were utilized. A crystal oscillator is used to improve short-term stability and performance on a moving platform.

Bloch, M. B.↗

Innovation and reliability of atomic standards for PTTI applications

Innovation and reliability in hyperfine frequency standards and clock systems are discussed. Hyperfine standards are defined as those precision frequency sources and clocks which use a hyperfine atomic transition for frequency control and which have realized significant commercial production and acceptance (cesium, hydrogen, and rubidium atoms). References to other systems such as thallium and ammonia are excluded since these atomic standards have not been commercially exploited in this country.

Kern, R.↗

Metafitting: Weight optimization for least-squares fitting of PTTI data

For precise time intercomparisons between a master frequency standard and a slave time scale, we have found it useful to quantitatively compare different fitting strategies by examining the standard uncertainty in time or average frequency. It is particularly useful when designing procedures which use intermittent intercomparisons, with some parameterized fit used to interpolate or extrapolate from the calibrating intercomparisons. We use the term 'metafitting' for the choices that are made before a fitting procedure is operationally adopted. We present methods for calculating the standard uncertainty for general, weighted least-squares fits and a method for optimizing these weights for a general noise model suitable for many PTTI applications. We present the results of the metafitting of procedures for the use of a regular schedule of (hypothetical) high-accuracy frequency calibration of a maser time scale. We have identified a cumulative series of improvements that give a significant reduction of the expected standard uncertainty, compared to the simplest procedure of resetting the maser synthesizer after each calibration. The metafitting improvements presented include the optimum choice of weights for the calibration runs, optimized over a period of a week or 10 days.

Douglas, Rob J.↗

The frequency and time standard and activities at the Beijing Institute of Radio Metrology and Measurements

Three kinds of frequency measuring systems are described: frequency comparison, phase comparison, and time comparison. With the help of the portable cesium clock in determining the time delay between two stations, a time synchronization, experiment was conducted using the Symphonie satellite. A result with an accuracy of 30 ns and an uncertainty of about 10 ns was obtained. Another experiment, applying the television pulse technique for time synchronization, yielded a result with an error of about 0.5 mu s in 24 hours. In order to measure the short term frequency stability of crystal oscillators or other frequency sources, a rubidium maser atomic frequency standard was developed as well as a short term stability measuring system.

Wang, H. T.↗

Historical Cost Curves for Hydrogen Masers and Cesium Beam Frequency and Timing Standards

Historical cost curves were developed for hydrogen masers and cesium beam standards used for frequency and timing calibration in the Deep Space Network. These curves may be used to calculate the cost of future hydrogen masers or cesium beam standards in either future or current dollars. The cesium beam standards are decreasing in cost by about 2.3% per year since 1966, and hydrogen masers are decreasing by about 0.8% per year since 1978 relative to the National Aeronautics and Space Administration inflation index.

Remer, D. S.↗