Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fire”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Space-Cabin Atmospheres: Part II - Fire and Blast Hazards. A Literature Review

The rapid evolution of aircraft and, lately, space vehicles has brought with it the ever-increasing difficulty of designing for prevention of fires and explosions. The present-day sealed cabin with its limited work space, unusual atmospheric constituents, and lack of flexibility in emergency situations has brought new and ill-defined hazards into the picture. In the past, numerous data have been compiled on the fire and explosion characteristics of all things combustible. Unfortunately, much of the material is not pertinent to the actual operational problems in space. The confusion and controversy arising from attempts to evaluate the space-cabin fire problem appear to stem from past failure to compile the scattered data and to expose it to critical review and selection. In the compilation that follows, an attempt has been made to review the best available data that was deemed actually pertinent to the present problem. The effects of unusual atmospheres have been emphasized, but, as will soon be evident, other physical parameters also play a major role in determining the nature of the problem. Chapter 1 contains a discussion of pertinent definitions and theory. This is detailed only to the point of anticipating some of the problems of interpretation that may arise in other chapters of the report. Included in this chapter is speculation on the impact of unusual environmental conditions such as aerodynamic heating, reduced gravitational acceleration, and low ambient pressures. Chapter 2 covers flammable fabrics and carbonaceous solids; Chapter 3, specific fire hazards involving flammable liquids, vapors, and gases; and Chapter 4, electrical fires. Chapter 5 covers the fire, blast, and flash hazards from meteoroid penetration; and Chapter 6, the problems of fire prevention and extinguishment in space cabins. Chapter 7 reviews the factors of fire and blast hazards in selection of a space-cabin atmosphere.

Roth, Emanuel M.↗

Full-scale aircraft cabin flammability tests of improved fire-resistant materials

Full-scale aircraft cabin flammability tests to evaluate the effectiveness of new fire-resistant materials by comparing their burning characteristics with those of older aircraft materials are described. Three tests were conducted and are detailed. Test 1, using pre-1968 materials, was run to correlate the procedures and to compare the results with previous tests by other organizations. Test 2 included newer, improved fire-resistant materials. Test 3 was essentially a duplicate of test 2, but a smokeless fuel was used. Test objectives, methods, materials, and results are presented and discussed. Results indicate that the pre-1968 materials ignited easily, allowed the fire to spread, produced large amounts of smoke and toxic combustion products, and resulted in a flash fire and major fire damage. The newer fire-resistant materials did not allow the fire to spread. Furthermore, they produced less, lower concentrations of toxic combustion products, and lower temperatures. The newer materials did not produce a flash fire.

Stuckey, R. N.↗

Fire behavior and risk analysis in spacecraft

Practical risk management for present and future spacecraft, including space stations, involves the optimization of residual risks balanced by the spacecraft operational, technological, and economic limitations. Spacecraft fire safety is approached through three strategies, in order of risk: (1) control of fire-causing elements, through exclusion of flammable materials for example; (2) response to incipient fires through detection and alarm; and (3) recovery of normal conditions through extinguishment and cleanup. Present understanding of combustion in low gravity is that, compared to normal gravity behavior, fire hazards may be reduced by the absence of buoyant gas flows yet at the same time increased by ventilation flows and hot particle expulsion. This paper discusses the application of low-gravity combustion knowledge and appropriate aircraft analogies to fire detection, fire fighting, and fire-safety decisions for eventual fire-risk management and optimization in spacecraft.

Friedman, Robert↗

Satellite Investigations of Fire, Smoke, and Carbon Monoxide during April 1994 MAPS Mission: Case Studies over Tropical Asia

During April 9-19, 1994, the Measurement of Air Pollution from Satellites (MAPS) measured free tropospheric carbon monoxide (CO) concentrations on a near-global basis. For these eleven days the global lkm advanced very high resolution radiometer (AVHRR) Pathfinder data are used to detect fires and smoke over the Indo-Burma region (85 degrees E - 110 degrees E; 10 degrees N -30 degrees N). The fire activities are categorized for four major ecosystems that include (1) cropland/natural vegetation mosaic (CNVM), (2) evergreen broadleaf forest (EBF), (3) mixed forest (MFD), and (4) grassland (GL). Using published emission rates between particulate matter and carbon monoxide concentrations from temperate areas, the fire counts along with other information are used to obtain estimates of CO concentrations from the AVERR data. More than 7000 fires are detected during the study period with 23%, 43%, 24%, and 10% fires in the CNVM, EBF, MFD, and GL ecosystems, respectively. The enhanced CO concentrations over the area of study are either over or downwind of the fires detected by the AVHRR. The preliminary AVHRR estimates of CO concentrations are smaller than the MAPS-measured values by a factor of 4 to 5 for fire counts areater than 200. The differences are attributed to the lack of transport mechanisms and other assumptions in the current model. However, these results show a good potential for usino the AVHRR measurements to detect fires and smoke and also to estimate CO concentrations.

Christopher, Sundar A.↗

Detecting the Onset of Fire in an Aircraft by Employing Correlation Spectroscopy

The cause of aircraft fire and locations of the fires are numerous. Worldwide, numerous in-flight fires have been passenger initiated, the prime location being the lavatory areas. Most in-flight fires in commercial carriers are of electrical origin and cigarettes. A cargo bay fire can be caused by a variety of reasons. The sheer number of different types of cargo makes it difficult to identify the origin, especially when the fire reaches the catastrophic level. The damage can be minimized, and fire can be suppressed effectively if a warning system for the onset of fire is available for onboard monitoring.

Goswami, Kisholoy↗

Further Discussion: Parametric Study of Wind Generated Supermicron Particle Effects in Large Fires

In their reply (Porch et al., 1987) to our comments (Turco et al., 1987) on their smoke-scavenging-by-dust paper, Porch et al. attempt to justify a number of parameter assumptions in their original article, again revealing the extreme nature of those assumptions, particularly in the situation where all are taken simultaneously. In critiquing Porch et al.'s calculations, have not applied "opinion", but rather physical reality and common sense expressed through basic experimental results and logical physical bounds. A few examples of the unrealistic conditions required by the Porch et al. scavenging scheme, as described in their paper and comments, should suffice here. ) Porch et al. have fabricated a "fetch" region for dust particles in large fire plumes that logically must extend over an area up to 50 times greater than the fire area itself. Alternatively, they have invoked significant "necking down' of the fire plume, so that its cross-sectional area is at most a few percent of the fire area. Such severe constriction is seen only in very small fires with strong, organized vorticity, and then only over a limited plume rise region. No "fetch" has ever been noted in any large-scale fires we have observed, or for which accounts are available. Indeed, as we deduced in our original comments, complete dust scavenging even within the fire zone would probably occur less than 10% of the time for large urban fires.

Toon, O. B.↗

Physical and Chemical Aspects of Fire Suppression in Extraterrestrial Environments

A fire, whether in a spacecraft or in occupied spaces on extraterrestrial bases, can lead to mission termination or loss of life. While the fire-safety record of US space missions has been excellent, the advent of longer duration missions to Mars, the moon, or aboard the International Space Station (ISS) increases the likelihood of fire events, with more limited mission termination options. The fire safety program of NASA's manned space flight program is based largely upon the principles of controlling the flammability of on-board materials and greatly eliminating sources of ignition. As a result, very little research has been conducted on fire suppression in the microgravity or reduced-gravity environment. The objectives of this study are: to obtain fundamental knowledge of physical and chemical processes of fire suppression, using gravity and oxygen concentration as independent variables to simulate various extraterrestrial environments, including spacecraft and surface bases in Mars and moon missions; to provide rigorous testing of analytical models, which include comprehensive descriptions of combustion and suppression chemistry; and to provide basic research results useful for technological advances in fire safety, including the development of new fire-extinguishing agents and approaches, in the microgravity environment associated with ISS and in the partial-gravity Martian and lunar environments.

Takahashi, F.↗

Fires and Smoke Observed from the Earth Observing System MODIS Instrument: Products, Validation, and Operational Use

The MODIS sensor, launched on NASA's Terra satellite at the end of 1999, was designed with 36 spectral channels for a wide array of land, ocean, and atmospheric investigations. MODIS has a unique ability to observe fires, smoke, and burn scars globally. Its main fire detection channels saturate at high brightness temperatures: 500 K at 4 microns and 400 K at 11 microns, which can only be attained in rare circumstances at the I kin fire detection spatial resolution. Thus, unlike other polar orbiting satellite sensors with similar thermal and spatial resolutions, but much lower saturation temperatures (e.g. AVHRR and ATSR), MODIS can distinguish between low intensity ground surface fires and high intensity crown forest fires. Smoke column concentration over land is for the first time being derived from the MOMS solar channels, extending from 0.41 microns to 2.1 microns. The smoke product has been provisionally validated both globally and regionally over southern Africa and central and south America. Burn scars are observed from MODIS even in the presence of smoke, using the 1.2 to 2.1 micron channels. MODIS burned area information is used to estimate pyrogenic emissions. A wide range of these fire and related products and validation are demonstrated for the wild fires that occurred in northwestern United States in the summer of 2000. The MODIS rapid response system and direct broadcast capability is being developed to enable users to obtain and generate data in near real time. It is expected that health and land management organizations will use these systems for monitoring the occurrence of fires and the dispersion of smoke within two to six hours after data acquisition.

Kaufman, Y. J.↗

Forest Understory Fire in the Brazilian Amazon in ENSO and Non-ENSO Years: Area Burned and Committed Carbon Emissions

"Understory fires" that burn the floor of standing forests are one of the most important types of forest impoverishment in the Amazon, especially during the severe droughts of El Nino Southern Oscillation (ENSO) episodes. However, we are aware of no estimates of the areal extent of these fires for the Brazilian Amazon and, hence, of their contribution to Amazon carbon fluxes to the atmosphere. We calculated the area of forest understory fires for the Brazilian Amazon region during an El Nino (1998) and a non El Nino (1995) year based on forest fire scars mapped with satellite images for three locations in eastern and southern Amazon, where deforestation is concentrated. The three study sites represented a gradient of both forest types and dry season severity. The burning scar maps were used to determine how the percentage of forest that burned varied with distance from agricultural clearings. These spatial functions were then applied to similar forest/climate combinations outside of the study sites to derive an initial estimate for the Brazilian Amazon. Ninety-one percent of the forest area that burned in the study sites was within the first kilometer of a clearing for the non ENSO year and within the first four kilometers for the ENSO year. The area of forest burned by understory forest fire during the severe drought (ENSO) year (3.9 millions of hectares) was 13 times greater than the area burned during the average rainfall year (0.2 million hectares), and twice the area of annual deforestation rate. Dense forest was, proportionally, the forest area most affected by understory fires during the El Nino year, while understory fires were concentrated in transitional forests during the year of average rainfall. Our estimate of aboveground tree biomass killed by fire ranged from 0.06 Pg to 0.38 Pg during the ENSO and from 0,004 Pg to 0,024 Pg during the non ENSO.

Alencar, A.↗

NASA 2007 Western States Fire Missions (WSFM)

This viewgraph presentation describes the Western states Fire Missions (WSFM) that occurred in 2007. The objectives of this mission are: (1) Demonstrate capabilities of UAS to overfly and collect sensor data on widespread fires throughout Western US. (1) Demonstrate long-endurance mission capabilities (20-hours+). (2) Image multiple fires (greater than 4 fires per mission), to showcase extendable mission configuration and ability to either linger over key fires or station over disparate regional fires. (3) Demonstrate new UAV-compatible, autonomous sensor for improved thermal characterization of fires. (4) Provide automated, on-board, terrain and geo-rectified sensor imagery over OTH satcom links to national fire personnel and Incident commanders. (5) Deliver real-time imagery to (within 10-minutes of acquisition). (6) Demonstrate capabilities of OTS technologies (GoogleEarth) to serve and display mission-critical sensor data, coincident with other pertinent data elements to facilitate information processing (WX data, ground asset data, other satellite data, R/T video, flight track info, etc).

Buoni, Greg↗

Development of a Test Protocol for Spacecraft Post-Fire Atmospheric Cleanup and Monitoring

Detecting and extinguishing fires, along with post-fire atmospheric cleaning and monitoring, are vital components of a spacecraft fire response system. Preliminary efforts focused on the technology evaluation of these systems under realistic conditions are described in this paper. While the primary objective of testing is to determine a smoke mitigation filter s performance, supplemental evaluations measuring the smoke-filled chamber handheld commercial off-the-shelf (COTS) atmospheric monitoring devices (combustion product monitors) are also conducted. The test chamber consists of a 1.4 cubic meter (50 cu. ft.) volume containing a smoke generator. The fuel used to generate the smoke is a mixture of polymers in quantities representative of materials involved in a circuit board fire as a typical spacecraft fire. Two fire conditions were examined: no flame and flame. No flame events are produced by pyrolyzing the fuel mixture in a quartz tube furnace with forced ventilation to produce a white, lingering-type smoke. Flame events ignite the smoke at the outlet of the tube furnace producing combustion characterized by a less opaque smoke with black soot. Electrochemical sensor measurements showed carbon monoxide is a major indicator of each fire. Acid gas measurements were recorded, but cross interferents are currently uncharacterized. Electrochemical sensor measurements and sample acquisition techniques from photoacoustic sensors are being improved. Overall, this research shows fire characterization using traditional analytical chemistry techniques is required to verify measurements recorded using COTS atmospheric monitoring devices.

Zuniga, David↗

Fine-Water-Mist Multiple-Orientation-Discharge Fire Extinguisher

A fine-water-mist fire-suppression device has been designed so that it can be discharged uniformly in any orientation via a high-pressure gas propellant. Standard fire extinguishers used while slightly tilted or on their side will not discharge all of their contents. Thanks to the new design, this extinguisher can be used in multiple environments such as aboard low-gravity spacecraft, airplanes, and aboard vehicles that may become overturned prior to or during a fire emergency. Research in recent years has shown that fine water mist can be an effective alternative to Halons now banned from manufacture. Currently, NASA uses carbon dioxide for fire suppression on the International Space Station (ISS) and Halon chemical extinguishers on the space shuttle. While each of these agents is effective, they have drawbacks. The toxicity of carbon dioxide requires that the crew don breathing apparatus when the extinguishers are deployed on the ISS, and Halon use in future spacecraft has been eliminated because of international protocols on substances that destroy atmospheric ozone. A major advantage to the new system on occupied spacecraft is that the discharged system is locally rechargeable. Since the only fluids used are water and nitrogen, the system can be recharged from stores of both carried aboard the ISS or spacecraft. The only support requirement would be a pump to fill the water and a compressor to pressurize the nitrogen propellant gas. This system uses a gaseous agent to pressurize the storage container as well as to assist in the generation of the fine water mist. The portable fire extinguisher hardware works like a standard fire extinguisher with a single storage container for the agents (water and nitrogen), a control valve assembly for manual actuation, and a discharge nozzle. The design implemented in the proof-of-concept experiment successfully extinguished both open fires and fires in baffled enclosures.

Butz, James R.↗

Environmentally Safer, Less Toxic Fire-Extinguishing Agents

Fire-extinguishing agents comprising microscopic drops of water microencapsulated in flame-retardant polymers have been proposed as effective, less toxic, non-ozone-depleting, non-globalwarming alternatives to prior fire-extinguishing agents. Among the prior fire-extinguishing agents are halons (various halocarbon fluids), which are toxic and contribute both to depletion of upperatmospheric ozone and to global warming. Other prior fire-extinguishing agents are less toxic and less environmentally harmful but, in comparison with halons, are significantly less effective in extinguishing fires. The proposal to formulate new waterbased agents is based on recent success in the use of water mist as a fire-suppression agent. Water suppresses a flame by reducing the flame temperature and the concentration of oxygen available for the combustion process. The temperature is reduced because the water droplets in the mist absorb latent heat of vaporization as they evaporate. The concentration of oxygen is reduced because the newly generated water vapor displaces air. Unfortunately, water mists are difficult to produce in confined spaces and can evaporate before they reach the bases of flames. The proposal addresses both of these issues: The proposed fire-extinguishing agents would be manufactured in microencapsulated form in advance, eliminating the problem of generating mists in confined spaces. Because of the microencapsulation, the droplets would not evaporate until exposed directly to the heat of flames. In addition, the proposal calls for the introduction of free radicals that would inhibit the propagation of the chemical reactions of the combustion reactions. Manufacturing of a fire-extinguishing agent according to the proposal would begin with the formulation of a suitable polymer (e.g., a polybromostyrene) that would contribute free radicals to the combustion process. The polymer would be dissolved in a suitable hydrocarbon liquid (e.g., toluene). Water would be dispersed in the polymer/toluene solution, then another hydrocarbon liquid (e.g., hexane) that is not a solvent for the polymer would be added to the mixture to make the dissolved polymer precipitate onto the water droplets. The resulting polymer-coated droplets would be removed from the coating mixture by filtration, dried, and stored for use.

Parrish, Clyde F.↗

A Pan-Tropical Cascade of Fire Driven by El Nino/Southern Oscillation

The El Nino/Southern Oscillation (ENSO) has a pronounced influence on year-to-year variations in climate. The response of fires to this forcing is complex and has not been evaluated systematically across different continents. Here we use satellite data to create a climatology of burned-area and fire emissions responses, drawing on six El Nino and six La Nina events during 1997-2016. On average, reductions in precipitation and terrestrial water storage increased fire emissions in pan-tropical forests by 133% during and following El Nino as compared with La Nina. Fires peaked in equatorial Asia early in the ENSO cycle when El Nino was strengthening (Aug-Oct), before moving to southeast Asia and northern South America (Jan-Apr), Central America (Mar-May) and the southern Amazon (Jul-Oct) during the following year. Large decreases in fire occurred across northern Australia during Sep-Oct of the second year from a reduced fuel availability. Satellite observations of aerosols and carbon monoxide provided independent confirmation of the spatiotemporal evolution of fire anomalies. The predictable cascade of fire across different tropical continents described here highlights an important time delay in the Earth system's response to precipitation redistribution. These observations help to explain why the growth rate of atmospheric CO2 increases during El Nino and may contribute to improved seasonal fire forecasts.

Chen, Yang↗

Chemical Challenge Tests on ISS Fire Cartridges

Following a confirmed combustion event onboard the International Space Station (ISS), crew members will don Emergency Masks, each fitted with 2 ISS fire cartridge filters. As the crew member breathes through the filters, combustion products in the cabin air are either filtered or catalyzed by the fire cartridge media to minimize crew exposure to harmful levels of contaminants. Rigorous certification, acceptance, and surveillance programs for the fire cartridges ensure that each lot meets stringent performance requirements throughout the service life of the cartridges. In accordance with the Quality/Acceptance Test Plan, multiple fire cartridges from each lot undergo chemical challenge tests involving one or more chemicals at specified concentrations. These tests are conducted at specific temperatures, humidity levels, and gas flow rates intended to mimic the worst-case conditions for fire cartridge performance. These challenge tests are conducted by the Environmental Chemistry- Laboratory at the NASA Lyndon B. Johnson Space Center. Many of the challenge tests focus on carbon monoxide (CO), but other gases include hydrogen cyanide (HCN), hydrogen chloride (HCl), cyclohexane, acrolein, ammonia (NH3), and acetaldehyde. A fire cartridge is exposed to the test gas in a chamber at the specified conditions, and the outlet is monitored for breakthrough during the 2.5-hour test. This paper will briefly introduce fire cartridges and how they work and will then discuss details of the challenge gas delivery and exposure system, breakthrough monitoring methods, and discussion of issues that have arisen during the course of the test program. Although the focus of this paper will be on the challenge tests, a general summary of the performance of the fire cartridges will also be provided.

Cristina M. Muko↗

Speciation and Aqueous Dissolution of Macronutrients in Fire Ash: Variation across Ecosystems and the Effects on Nutrient Cycling

This study investigated the speciation and aqueous dissolution of macronutrients in fire ash from diverse ecosystems and speciation of ash and smoke from laboratory burning, exploring the variations and their causes. The speciation of phosphorus (P), calcium (Ca), and potassium (K) in fire ash from five globally distributed ecosystems was characterized by using X-ray absorption spectroscopy and sequential fractionation. Aqueous dissolution of the macronutrients was measured by batch experiments at acidic and alkaline pHs. The results showed that P existed mainly as Ca phosphates, Ca as double carbonates, calcite, and sulfates, and most K was associated with Ca carbonates. Mineralogy and the relative abundance of the species were primarily controlled by elemental stoichiometry and fire temperature. Differences in Ca and P speciation existed between ash and smoke from laboratory burning, possibly caused by the temperature difference and/or mass fractionation during burning. The rates, extents, and pH dependencies of macronutrient dissolution differed among macronutrients and depended on their speciation, with K being highly soluble and the P and Ca regulated by solution pH. The variability in ash macronutrient chemistry and ecosystemspecific fire ash loads resulted in varying loads and availability of individual macronutrient from fire among ecosystems. This study provides a mechanistic understanding of how fires transform the chemistry of macronutrients and affect macronutrient returns to soils across different ecosystems, which is essential for evaluating the disturbance to ecosystem nutrient cycling by fires.

54 ENVIRONMENTAL SCIENCES↗

Evaluating crown scorch predictions from a computational fluid dynamics wildland fire simulator

Abstract Background Crown scorch—the heating of live leaves, needles, and buds in the vegetative canopy to lethal temperatures without widespread combustion—is one of the most common fire effects shaping post-fire canopies. Despite the ability of computational fluid dynamic models to finely resolve fire activity and buoyant plume dynamics including heterogenous 3D distributions of forest canopy heating, these models have had only limited use in simulating fire effects and have not been used to evaluate crown scorch. Here, we demonstrate a method of evaluating crown scorch using a computational fluid dynamics model, FIRETEC, and validate this approach by simulating the experiments that were used to develop Van Wagner’s 1973 crown scorch model. Results The average scorch height prediction from FIRETEC compares well with the empirical model derived by Van Wagner, which is the most widely used empirical model for crown scorch. We further find that the 3D buoyant plume dynamics from a steady and homogeneous idealized heat source on the ground results in a spatially heterogenous crown scorch pattern reflecting complex heating dynamics that are best represented by percent scorch rather than height of scorch. Conclusions The ability of the computational fluid dynamics model to capture variation in crown scorch due to 3D buoyant plume dynamics provides direct links between forest structure, fire behavior, and fire effects that can be used by forest managers and researchers to better understand how fires result in crown damage under various environmental and management scenarios.

54 ENVIRONMENTAL SCIENCES↗

Automated Fire Detection for Industrial Settings with Pretrained Convolutional Networks

Early fire detection in industrial environments is critical to preventing equipment damage, personal injury, and operational disruptions. Traditional smoke detectors, while effective, often experience delays due to the time required for smoke to reach sensors, allowing fires to spread. Manual fire watch operations and human surveillance of camera feeds are resource-intensive and prone to human error. To address these challenges, this paper explores the application of convolutional neural networks for automated fire detection, specifically in industrial settings. By leveraging 11 different pre-trained machine vision models from TensorFlow and enhancing them with transfer learning on a custom-built industrial fire dataset, we optimized fire detection performance. Here, we analyzed each machine vision model architecture in terms of its depth, width, and input image resolution, considering both resource requirements and detection accuracy. We further explored the option of combining multiple models into an ensemble classifier to evaluate whether the performance improvements could justify the much greater computational complexity and other practical impacts. A cost-benefit analysis is presented to evaluate the trade-offs between performance and computational expense. Our findings identify that EfficientNetV2L, specifically tailored for industrial applications, provides the optimal balance between costs involved in training and using the model versus the overall fire detection performance. Additionally, we present a qualitative analysis of model performance using the technique of gradient-based class activation mapping to provide explainability by visualizing model decisions.

artificial intelligence↗