Search NASA⌕ Search

SEARCH · Search NASA

Results for “Flight data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Low energy neutron light output characterization of EJ301D and deuterated stilbene with a comparison of light output characterization methods

The neutron-induced light yield of a 2.54 cm diameter by 2.54 cm long right circular cylinder of EJ301D and a (5.08 cm)3 custom made cube of deuterated trans-stilbene-d12 (d-stilbene) were measured over incident neutron energies from 300 keV to 2.2 MeV and 200 keV to 2.4 MeV, respectively. The measurements were performed using a time-of-flight experiment with a Cf-252 source and an approximately 1.5 m flight path. We compare three light output spectrum full energy deposition edge estimation methods: (1) simulating the neutron energy spectrum edge and fitting it to the light output spectrum, (2) using the inflection point of the light output spectrum edge (derivative method, a.k.a. Kornilov’s method), and (3) using an empirical model fit to the edge of the light output spectrum. Both the derivative and equation fit methods do not account for physical processes such as multiple neutron scattering in the detectors. They instead rely on assumptions about the linear shape continuum shape of the light output spectrum and the direct correlation between the location of the spectrum’s inflection point and maximum energy deposition. These assumptions were found to introduce bias into those methods when tested against simulated spectra with known edge locations. When tested against measured spectra the derivative method was found to differ from the simulation fit by greater than 30% at low energies with large discontinuities for adjacent data points above 800 keV incident neutron energy. The empirical equation fitting method was found to also exhibit bias of a similar magnitude, but with significantly more continuous behavior, especially with the lower count data of the smaller volumed EJ301D scintillator. Experimental light output yield for this neutron energy range is reported using the simulated spectrum fitting method because it includes physics neglected by the other methods, and did not exhibit the bias observed in the other methods

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Psyche Gamma-Ray and Neutron Spectrometer

A Gamma-Ray and Neutron Spectrometer (GRNS) instrument has been developed as part of the science payload for NASA’s Discovery Program Psyche mission to the M-class asteroid (16) Psyche. The GRNS instrument is designed to measure the elemental composition of Psyche with the goal to understand the origin of this mysterious, potentially metal-rich planetary body. The GRNS will measure the near-surface abundances for the elements Ni, Fe, Si, K, S, Al, and Ca, as well as the spatial distribution of Psyche’s metal-to-silicate fraction (or metal fraction). These measurements address three of the five Psyche mission science objectives: determine if Psyche is a core; determine whether small metal bodies incorporate light elements into the metal phase; and determine whether Psyche was formed under reducing conditions. The Gamma-Ray Spectrometer (GRS) uses a cryocooled, high-purity Ge (HPGe) sensor to detect cosmic-ray generated gamma rays in the 60 to 9000-keV energy range. The HPGe sensor is surrounded by a borated plastic anticoincidence shield that provides three functions: active background rejection from charged particle interactions in the HPGe sensor; fast neutron measurements; and direct measurements of the incident galactic cosmic ray flux. The Neutron Spectrometer (NS) uses three 3 He gas proportional sensors, each with different material wraps to measure thermal (<0.4 eV), low-energy epithermal (0.4 eV to 1 keV), and high-energy epithermal (up to 100 keV) neutrons. This paper provides an overview of the Psyche GRNS, including: its science and measurement objectives; the design of the instrument hardware, software, and operation; pre-launch performance measurements and its initial performance in space; and an overview of its data products and expected operation for different Psyche mission phases.

Engineering - Instrumentation related to nuclear s↗

Application of a Chemical Index to Aerosol Mass Spectrometry: Delta Plots and Functional Group Distributions

A better understanding of the chemical properties of organic aerosol (OA) particles will improve our ability to characterize their sources and predict their lifetime. The high-resolution time-of-flight aerosol mass spectrometer (HR-ToF-AMS) is widely used to measure OA in real time using thermal vaporization followed by electron ionization (EI). EI creates fragment ions that can be assigned to functional groups using delta analysis, a method of classifying mass spectra according to the presence of different chemically related ion series. In this study, we demonstrate the application of delta analysis to characterize molecular structures using a new visualization method. We also use delta analysis to quantify the functional group distribution with an average absolute error of ∼5–6% for individual standard molecules, comparable to the error observed for OA mixtures from biomass and coal combustion fit with Fourier transform infrared spectroscopy. Finally, we apply delta functional group analysis to AMS positive matrix factorization (PMF) factors across seven different field campaigns and find a similar composition across the more oxidized factors with about 55% acid and 26% alcohol groups. The analysis method described here can be applied to any HR-ToF-AMS data set to provide quantitative relative functional group distributions for OA mixtures.

aerosol↗

Nonlinear light-output calibration of the oxygenated xylene scintillators used in OMEGA neutron time-of-flight spectrometers

Neutron time-of-flight (nTOF) spectrometers are essential instruments for measuring and evaluating the performance of inertial confinement fusion implosions. The neutron spectrometers utilized for the OMEGA laser include two liquid-based scintillators, each consisting of a large volume filled with xylene that is coupled to four photomultiplier tubes. Analysis of the signal from these detectors requires detailed knowledge of the scintillator’s light output, which is needed to fit the nTOF spectrum, from which the neutron energy spectrum is informed. The light output is nonlinearly proportional to the neutron energy, which, in turn, affects the interpretation of the neutron energy spectrum from a TOF signal. A recent campaign on OMEGA was performed to calibrate the xylene detectors and infer the shape of the light-output curve. The campaign utilized materials with increasing Z placed in the OMEGA target chamber to initiate scattering events with the 14 MeV fusion neutrons. This process leads to the production of backscatter neutrons of varying energies that appear as peaks in the nTOF data. Simulations using a neutron transport code were combined with the measured deuterium–tritium neutron yields to calculate the expected backscattered neutron yields from the well-known scattering cross sections of each material. Furthermore, the neutron-energy dependent light output of the scintillator inferred from the experiment is compared to the light-output curve simulated with a neutron transport code for the following neutron energies: 1.5, 2.5, 6, and 14 MeV.

47 OTHER INSTRUMENTATION↗

Anomalous resistivity and electron heating by lower hybrid drift waves inside reconnecting current sheets

Inside an electron diffusion region of laboratory reconnection experiments, the quasi-electrostatic lower hybrid drift wave (ES-LHDW) is observed when a significant guide field component is present. Through direct measurement of the anomalous drag term and quasilinear analysis, it is shown that ES-LHDW can account for approximately 20% of the mean reconnection electric field in a case with moderate guide field. This value exceeds the contribution from classical resistivity, which is around 10%. The effects of the Lorentz force term, often neglected for electrostatic waves, are crucial for the observed correlation between electric field and density fluctuations. Anomalous electron heating by the perturbed current and resistivity (2.6 MW/m 3 ) also surpasses the classical Ohmic heating, which is about 2.0 MW/m 3 . For the case with a high guide field, significantly higher local electron temperatures were observed during periods of strong ES-LHDW activity. A statistical analysis further supports electron heating by LHDW, showing a larger increase in electron temperature with a high guide field. Finally, data from the Magnetospheric Multiscale mission provide evidence of Landau damping of ES-LHDW, suggesting that ES-LHDW may contribute to the generation of nonthermal electrons along the direction parallel to the magnetic field.

Magnetic reconnection↗

Optimization of X-ray event screening using ground and in-orbit data for the Resolve instrument onboard the XRISM satellite

The X-Ray Imaging and Spectroscopy Mission (XRISM) satellite was successfully launched and put into a low-Earth orbit on September 6, 2023 (UT). The Resolve instrument onboard XRISM hosts an X-ray microcalorimeter detector, which was designed to achieve a high-resolution ( ≤ 7 eV FWHM at 6 keV), high-throughput, and non-dispersive spectroscopy over a wide energy range. It also excels in a low background with a requirement of < 2 × 10 -3 s -1 keV -1 (0.3 to 12.0 keV), which is equivalent to only one background event per spectral bin per 100-ks exposure. Event screening to discriminate X-ray events from background is a key to meeting the requirement. We present the result of the Resolve event screening using data sets recorded on the ground and in orbit based on the heritage of the preceding X-ray microcalorimeter missions, in particular, the Soft X-ray Spectrometer onboard ASTRO-H. We optimize and evaluate 19 screening items of three types based on (1) the event pulse shape, (2) relative arrival times among multiple events, and (3) good time intervals. We show that the initial screening, which is applied for science data products in the performance verification phase, reduces the background rate to 1.8 × 10 -3 s -1 keV -1 meeting the requirement. We further evaluate the additional screening utilizing the correlation among some pulse shape properties of X-ray events and show that it further reduces the background rate, particularly in the < 2 keV band. Over 0.3 to 12 keV, the background rate becomes 1.0 × 10 -3 s -1 keV -1 .

47 OTHER INSTRUMENTATION↗

Solidification cracking of refractory alloys: a computational and machine learning study to investigate composition-dependence for improved weldability and additive manufacturability

Large-batch numerical, CALculation of PHAse Diagrams (CALPHAD)-based solidification cracking calculations are performed and then analyzed with machine learning methods to generate models that relate chemistry of refractory alloys to cracking susceptibility. Kou’s solidification cracking index is used to study the refractory alloys including O, N, C binary mixtures with Mo, Ta, Nb, and W, the molybdenum-based TZM, Niobium-based C103, and Tantalum-based T111 and Ta-10 W, as well as hypothetical refractory ternary alloys. Findings strongly validate Kou’s Crack Susceptibility Index (CSI) against Varestraint test data for Nb- and Ta-based alloys, establishing CSI thresholds where refractory alloys with CSI < 15,000 K are likely weldable, CSI > 15,000 K are prone to cracking, and CSI > 25,000 K are likely unweldable (or unprintable). Furthermore, interstitial elements C, N, and O significantly increase crack susceptibility, with some existing material specifications coinciding with peak cracking susceptibility concentrations. Finally, machine learning-derived elemental potency factors enable rapid prediction of CSI from alloy chemistry for C103, TZM, Ta-10 W, and T-111 alloys. These results provide practical guidance for feedstock selection, powder reuse limits, and alloy specification amendments for welding and additive manufacturing applications.

36 MATERIALS SCIENCE↗

NASA’s Pandora SmallSat Mission: Simulated Modeling and Retrieval of Near-infrared Exoplanet Transmission Spectra

Pandora is a SmallSat mission dedicated to understanding exoplanets and their host stars by disentangling the impact of stellar heterogeneity on exoplanet transmission spectra. Selected as a NASA Astrophysics Pioneers mission in 2021, Pandora will provide simultaneous long-term visible photometric monitoring (0.4–0.7 μm) and low-resolution near-infrared (NIR) spectroscopy (0.9–1.6 μm) of transiting systems for the purposes of monitoring host star variability and characterizing exoplanetary atmospheres. Pandora’s year-long prime mission from 2026 to 2027 coincides with the middle of a decade defined by targeted efforts for atmospheric characterization of exoplanets, offering a key opportunity to leverage this new resource to maximize science with JWST and other observatories. Here we investigate Pandora’s anticipated performance for the general exoplanet population accessible to transit spectroscopy, from hot Jupiters to temperate sub-Neptunes. By modeling the atmospheres of five test cases broadly consistent with the bulk properties of HD 209458b, HD 189733b, WASP-80 b, HAT-P-18 b, and K2-18 b, we find that Pandora may provide abundance constraints as precise as ∼1.0 dex for main atmospheric absorbers such as H 2 O and CH 4 . Then, we explore the synergies between Pandora and JWST. Our results suggest that targets with JWST data in the NIR can benefit from the addition of Pandora observations and result in more reliable abundance estimates than with JWST data alone. Moreover, Pandora can serve the community by providing precursory observations of targets of interest for JWST atmospheric characterization. We conclude by outlining strategies for the use of Pandora as a standalone observatory and in synergy with JWST.

79 ASTRONOMY AND ASTROPHYSICS↗

Absolute timing calibration of the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission

The Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission (XRISM) is designed to have a good timing capability with the mission-level requirement of 1 ms as the absolute time tagging accuracy to suffice the needs for observatory science. In the ground calibration campaign, the absolute and relative timing offsets were measured using pulsed X-rays from the modulated X-ray sources. These offsets were used to determine calibration parameters, the Resolve timing coefficients, which are used in the offline correction of event times. In the orbit, reevaluation of the timing coefficients was carried out using the Crab pulsar, which was observed in two periods, one in the performance verification phase and the other in the guest observation phase. We report the absolute timing calibration of XRISM/Resolve using the ground and in-orbit data. Although the requirement is likely satisfied with the ground parameters, the timing coefficients have been refined using the in-orbit calibration to improve the timing accuracy. In addition, for the first time, we present the interpretation of the absolute timing offset originating from the analog and digital processing of X-ray events unique to a microcalorimeter spectrometer and present a complete view of the timing error of the Resolve instrument.

Astronomy and AstroPhysics↗

Aerosol Microphysics and Chemical Measurements at Mt. Soledad and Scripps Pier during the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE) from February 2023 to February 2024 UCSD Library Collection

This dataset includes guest instrument measurements and other PI products for aerosol microphysics and chemical measurements collected at Mt. Soledad and Scripps Pier during the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE) from February 2023 to February 2024. The measurements include the following instruments at Mt. Soledad: High-Resolution Time-of-Flight Aerosol Mass Spectrometer (HR-ToF-AMS, Aerodyne), Scanning Electrical Mobility Spectrometer (SEMS, Brechtel Manufacturing Inc.), Aerodynamic Particle Sizer (APS, Droplet Measurements Technologies), Single Particle Soot Photometer (SP2, Drople Measurements Technologies), Meteorological Station (WXT520, Vaisala), Ozone (Teco), and trace gas proxies (Teledyne). In addition, the analyses of particle filters collected at Mt. Soledad for three dry-diameter size cuts (<1 micron, <0.5 micron, <0.18 micron) and at Scripps Pier for one dry-diameter size cut (<1 micron) by Fourier Transform Infrared (FTIR) and X-ray Fluorescence (XRF) are reported. A differential mobility analyzer operated as a scanning mobility particle sizer (SMPS, TSI Inc.), a printed particle optical spectrometer (POPS, Grimm), and a continuous flow diffusion cloud condensation nuclei (CCN, DMT) counter provide the mobility aerosol size distribution (30-360 nm), optical size distribution (150 - 6000 nm), size-resolved CCN distribution (30-360 nm) at 0.2, 0.4, 0.6, 0.8, and 1.0% supersaturation. Measurements are reported for both sampling from an isokinetic aerosol inlet and from a Counterflow Virtual Impactor (CVI, Brechtel Manufacturing Inc.). The data are available at the following link: https://library.ucsd.edu/dc/collection/bb0898306q

54 ENVIRONMENTAL SCIENCES↗

Resonant scattering at the center of the galaxy cluster PKS 0745-191 with XRISM

We report evidence of the resonant scattering effect at the center of the galaxy cluster PKS 0745-191 with XRISM. We analyzed XRISM/Resolve commissioning-phase observations of the distant cluster PKS 0745-191 ($z = 0.103$) with a $54$ ks exposure. The gain drift was corrected using the onboard modulated X-ray source (MXS), and spectra were extracted from all the pixels that were well illuminated by MXS, the core region (four central pixels, $\sim$100 kpc), and the surrounding region. A single-temperature collisional ionization equilibrium (CIE) model fits the full field-of-view spectrum with $kT \approx 6$ keV and a turbulent velocity of ${\approx}120$ km s$^{-1}$. From the core ($r < 50$ kpc) spectrum, we detected a ${\approx}22\%$ suppression of the Fe xxv He$\alpha$ resonance (w) line relative to the CIE prediction. We performed a Monte Carlo simulation to calculate the resonant scattering (RS) effect using radial profiles from Chandra data. The RS-inferred turbulence agrees with that by Resolve line-broadening, demonstrating that RS provides an independent and consistent constraint on ICM turbulence. These results highlight XRISM/Resolve’s potential for turbulence studies in galaxy clusters.

Astronomy and AstroPhysics↗

A New Measurement of the Extragalactic Background Light Using 15 yr of Fermi-large Area Telescope Data

The extragalactic background light (EBL) from ultraviolet to infrared comprises the emission from all stars, galaxies, and actively accreting black holes in the observable Universe. A precise measurement of the EBL is critically important to probe models of star formation and galaxy evolution. The EBL can be measured via the absorption imprint left on the spectra of γ-ray blazars. In this work, we rely on 15 yr of Fermi-LAT data and 1576 blazars to measure the EBL optical depth in the 0 < z < 4.3 range. We detect the EBL attenuation with ≅23σ significance and measure the optical depth in 19 redshift bins, extending the coverage and improving on our previous results. This allows us to reconstruct the evolution of the EBL and find general consistency with recent EBL models. These results represent the most precise determination of the EBL with GeV γ rays to date.

79 ASTRONOMY AND ASTROPHYSICS↗

Particle signal considerations for isotope ratio analysis with single particle multi-collector inductively coupled plasma mass spectrometry

Particle analysis has benefitted from the advent of single particle inductively coupled plasma-mass spectrometry (spICP-MS) due to its robustness, sensitivity, and high-throughput nature. Previous methods of spICP-MS have typically utilized quadrupole or time-of-flight mass analyzers and therefore employ electron multiplier-based detectors (such as secondary electron multipliers or microchannel plates). However, to obtain precise measurements on elemental or isotopic ratios within individual particles, multi-collector ICP-MS (MC-ICP-MS) can be used. Here, we investigate Ce isotope ratios, specifically 142 Ce/ 140 Ce, by spMC-ICP-MS using an all-Faraday cup collector array. Using 1 μm (diameter) cerium dioxide particles, integration times of the Faraday cup detectors were varied from 50–500 ms. The signal from the cerium isotopes in the particles was used to determine isotope ratios, which closely matched the expected natural isotopic abundances. Due to the signal decay response from the Faraday cups, the signal from particles lasts much longer than the expected 1–2 ms (up to 100 s of ms). To explore this effect on isotope ratio analysis, multiple ratio analysis methods were used to determine how to obtain optimal precision and accuracy. Relative differences were around 2% for methods that calculated isotope ratios from summing the total signal of an individual particle before calculating the ratio (rather than using every data point individually). It was found that summing all data points per particle, or integrating under the signal peak, yielded both accurate and precise isotope ratios within the particle population. Particles were also sampled off a solid substrate via microextraction, and isotope ratios were determined with relative differences of 0.13% to 9%. This demonstrates the ability to use spMC-ICP-MS to obtain isotope ratios on particles, with little to no relative difference in comparison to the expected ratio, even when operating Faraday detectors at fast 50 ms integration times.

Szakas, Sarah E. [Oak Ridge National Laboratory (O↗

Lead Isotope Fingerprinting of Nanoscale Mineral Particles via Single Particle Inductively Coupled Plasma Mass Spectrometry

Determining lead (Pb) isotopic ratios is of broad interest across chemical disciplines for source tracing and age determinations, but the technique is inherently limited when multiple sources of Pb are present in a single sample. Single particle methods offer a solution to directly resolve multiple distinct isotopic ratios within individual samples. In this study, single particle inductively coupled plasma-mass spectrometry (spICP-MS) was performed using time-of-flight (TOF) and multicollector (MC)-based platforms to measure the Pb isotopic composition of individual nanoscale particles. Distinct Pb isotope ratios were measured in particles from four powdered galena samples of different origins (average single-particle 206Pb/207Pb ratios ranging from 0.91 to 1.28) using both the TOF and the MC-based platforms. Differentiation of galena particles in a mixture (liberated grains and those hosted in a silicate matrix) was possible due to detecting their unique multielemental fingerprints. The differing behavior of the two galena samples during digestion was investigated; undigested galena particles trapped within silicate minerals were detected using spICP-MS, which has implications for Pb recovery in bulk-scale isotopic analysis. The multinuclide detection capability of the ICP-TOF-MS instrument allowed for the simultaneous detection of secondary constituent elements within the nanoparticles and the identification of multiple populations of isotopically distinct Pb-bearing particles in a copper ore sample, whereas the increased sensitivity of the MC instrument enabled quantification of 204Pb, allowing differentiation using multiple isotopic ratios. A single particle isotope ratio analysis module was developed within an open-source spICP-TOF-MS data processing platform, enabling its adoption across chemical disciplines.

Goodman, Aaron J. [University of Montreal, Quebec,↗

Charge Trap Layer Supercharging for Improved Bit Reliability in 3-D NAND Flash Under Proton Irradiation

Single-event upset (SEU) cross sections are reduced in 176-layer charge trap (CT) 3-D nand devices under proton irradiation when multiple write operations are applied sequentially without the typical erase-before-write. Here, this effect is observed for multiple data patterns and in both single-level cell (SLC) and triple-level cell (TLC) operating modes. SEU cross section calculation methodologies are discussed for highly scaled 3-D devices both with and without the application of rewrites, and potential implications for long-term endurance effects are proposed.

Breeding, Matthew Luel [Sandia National Laboratori↗

The Global Spectra-Trait Initiative: A database of paired leaf spectroscopy and functional traits associated with leaf photosynthetic capacity (v1.0.0)

The Global Spectra-Trait Initiative (GSTI) aims to generate generalizable spectra trait models using reflectance data to predict leaf traits associated with the photosynthesis capacity of leaves. It comprises a synthesized dataset of leaf trait data, input datasets and code. Leaf traits include the maximum carboxylation rate of rubisco (Vcmax), the maximum electron transport rate (Jmax), the dark respiration, as well as the prediction of leaf nitrogen, leaf mass per area (LMA), and leaf water content (LWC). The dataset comprises >7500 paired observations from around 400 species from a broad range of biomes. This dataset comprises a zip file of the GSTI GitHub repository (https://github.com/plantphys/gsti), the synthesized database (.csv) and database metadata files. This dataset was updated on 2025-12-12 with minor edits to mirror the accepted manuscript version and GitHub release (Version 1.0.0 (ESSD accepted version)). Edits included minor changes to the project documentation on GitHub and removal of 12 duplicate entries from the database.

54 ENVIRONMENTAL SCIENCES↗

Absolute photoionization cross sections of brominated organics and determination of an effective C—Br bond cross section

For this work, absolute photoionization cross sections for five brominated species were measured using multiplexed synchrotron photoionization mass spectrometry at the Advanced Light Source (Lawrence Berkeley National Laboratory). These data enable reliable detection of bromine-containing compounds and estimation of C—Br bond photoionization cross sections. Complementary electronic-structure calculations provided adiabatic ionization energies in good agreement with experiment, while thermochemical appearance energies were measured directly. Bond dissociation energies for key fragmentation pathways of the neutral parent molecules were also analyzed. At 11 eV, cross sections were 53.8 ± 7.50 Mb (sp 2 C—Br) and 48.8 ± 7.70 Mb (sp 3 C—Br).

Brominated compounds↗

Investigating intermolecular interactions among CO 2 , water and PEEK-ionene membrane using cryo ToF-SIMS and isotopic labeling

Cryogenic time-of-flight secondary ion mass spectrometry (cryo ToF-SIMS) has emerged as a powerful tool for investigating molecular interactions, speciation, and dynamics in materials for CO 2 capture. In this study, we apply cryo ToF-SIMS to probe interactions between CO 2 , water, and PEEK-ionene membranes—a promising material for direct CO 2 capture due to its selectivity, durability, and efficiency. Despite this potential, the mechanisms governing CO 2 diffusion and the influence of water vapor on CO 2 behavior remain unclear. To address this, we loaded PEEK-ionene membranes with 13 CO 2 and D 2 O and employed cryo ToF-SIMS to visualize the 3D distribution of CO 2 and water within the membrane. While prior studies suggest that 13 CO 2 is absorbed under ambient conditions, our cryo ToF-SIMS analysis revealed no enhancement of the 13 C/ 12 C ratio, suggesting weak CO 2 -membrane interactions. As a result, CO 2 vaporizes even at low temperatures (−140°C) under vacuum conditions. In contrast, D 2 O displayed a relatively homogeneous distribution in the membrane, suggesting stronger water-membrane interactions via hydrogen bonding (18–20 kJ/mol). Interestingly, CO 2 was not detected in D 2 O-loaded membranes, indicating minimal interference from water vapor on CO 2 diffusion. As a comparison, the cryo ToF-SIMS data show that 13 CO 2 can readily react with a basic Na 2 CO 3 aqueous solution to form NaH 13 CO 3 . These findings demonstrate cryo ToF-SIMS as a critical technique for understanding gas-water-membrane interactions, offering insights for membrane functionalization to improve CO 2 capture efficiency.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗