Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fluidics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Helicopter Fuselage Active Flow Control in the Presence of a Rotor

This work extends previous investigations of active flow control for helicopter fuselage drag and download reduction to include the effects of the rotor. The development of the new wind tunnel model equipped with fluidic oscillators is explained in terms of the previous test results. Large drag reductions greater than 20% in some cases were measured during powered testing without increasing, and in some cases decreasing download in forward flight. As confirmed by Particle Image Velocimetry (PIV), the optimum actuator configuration that provided a decrease in both drag and download appeared to create a virtual (fluidic) boat-tail fairing instead of attaching flow to the ramp surface. This idea of a fluidic fairing shifts the focus of 3D separation control behind bluff bodies from controlling/reattaching surface boundary layers to interacting with the wake flow.

Martin, Preston B↗

BioSensor Users' Guide

The BioSensor is a fully autonomous 3-color LED-based spectrophotometer paired with a fluidics system that supports microbes in liquid culture. Originally developed for the BioSentinel CubeSat mission to study the response of a wild type and mutant strain of yeast to the deep space environment, the BioSensor consists of a series of 16-well, independently plumbed fluidics cards. The cards utilize filters to allow the fluidic system to administer reagents while constraining the microbes in their wells. Heaters on each card incubate to the appropriate growth temperature once the experiment begins. During the active experiment, the LED/detector system measures the transmission of light through each well at three specific wavelengths, similar to a standard benchtop spectrophotometer. The transmission/absorbance kinetics curves for each well are telemetered back to Earth, along with temperature data, for analysis on the ground. The BioSensor is being upgraded from its original CubeSat free-flyer interface to be a secondary payload on lunar landers, Gateway, and other BLEO applications, while maintaining the same functionality and science utility for future experiments.

Matthew Lera↗

BioSensor Users' Guide

The BioSensor is a fully autonomous 3-color LED-based spectrophotometer paired with a fluidics system that supports microbes in liquid culture. Originally developed for the BioSentinel CubeSat mission to study the response of a wild type and mutant strain of yeast to the deep space environment, the BioSensor consists of a series of 16-well, independently plumbed fluidics cards. The cards utilize filters to allow the fluidic system to administer reagents while constraining the microbes in their wells. Heaters on each card incubate to the appropriate growth temperature once the experiment begins. During the active experiment, the LED/detector system measures the transmission of light through each well at three specific wavelengths, similar to a standard benchtop spectrophotometer. The transmission/ absorbance kinetics curves for each well are telemetered back to Earth, along with temperature data, for analysis on the ground. The BioSensor is being upgraded from its original CubeSat free-flyer interface to be a secondary payload on lunar landers, Gateway, and other BLEO applications, while maintaining the same functionality and science utility for future experiments.

Matthew Lera↗

A Heritage BioSensor for Lunar Biology Experiments

Introduction: Automated biological experiments on small spacecraft missions have gained prominence over the past decade due to their simplicity, accessibility, and small mass, volume, and power needs. Most recently, the BioSensor microfluidic CubeSat payload aboard BioSentinel used an automated microfluidic cell culture system to study the effects of environmental stressors like deep space radiation and microgravity on yeast growth and metabolism. BioSentinel’s successor, the Lunar Explorer Instrument for space biology Applications (LEIA), will study the effects of lunar gravity and radiation using an improved version of the BioSensor microfluidic platform. The BioSensor payload has great adaptability to host a diverse range of biological experiments with single- and multi-celled organisms in both crewed and uncrewed missions, making it a compelling candidate for future space biology studies in a lunar surface environment. BioSensor Instrumentation on BioSentinel: The first spaceflight mission with the BioSensor, BioSentinel’s biology experiments occurred at three locations -- deep space, ISS and ground. The payload contained 18 microfluidic cards, each featuring 16 growth wells (a total of 288 growth wells). Each well was loaded before launch with desiccated yeast. In space, liquid culture medium (nutrients) was automatically introduced to batches of wells at a time to initiate a series of biology experiments. Temperature was maintained by thin film heaters on both sides of each card. Each well was equipped with three LEDs emitting at 570 nm, 630 nm, and 850 nm, paired with photodetectors to measure cell concentration and the alamarBlue (metabolic indicator dye) color transition from blue to pink. Phenotypic parameters like cell viability, metabolic rate, and generation time can be derived from these measurements. The sequence and timing of fluid fills, optical measurements, and thermal control were stored onboard, but could be updated asynchronously via ground communication. LEIA: LEIA is slated for launch no earlier than 2026 on a CLPS lander. BioSentinel’s BioSensor has been modified for use in LEIA. These improvements include: (a) storage for multiple culture medium types, (b) additional LED color (465 nm) for a new biological assay for antioxidant (carotenoid) production, (c) housing modifications for later biology load before launch, (d) improved isolation between electronic and fluidic components, and (e) improved humidity control for prolonged organism viability in case of post-load launch delay. Future Prospects: The consistent and successful demonstration of complex fluidics platforms alongside reliable instrument operations in a space environment is poised to create strong momentum for BioSensor-based biological experiment payloads. Planned future developments with the BioSensor include extending compatibility to a broader range of organisms and assays. Preliminary work has already demonstrated successful growth of Arabidopsis seedlings in fluidic cards. With a few modifications to the optical assembly, the setup could easily measure photosynthetic traits in plants and cyanobacteria. The addition of fluorescence measurements and generation of novel luminescent assays will elevate BioSensor’s functionality further. Beyond the BioSensor’s potential uses on free-flyer missions, ISS and Gateway, and CLPS landers, deploying the BioSensor to the lunar surface or in an artificial habitat on crewed missions could enable pioneering research on both how life responds to lunar conditions and future bioproduction capabilities making the BioSensor an indispensable tool for future space biology research.

Chinmayee Govinda Raj↗

Additively manufactured radial turbine rotor with cooling manifolds

A turbine rotor includes a base and a plurality of blades. A central nose is radially inward of the blades and defines an axis of rotation. A plurality of cooling manifolds is disposed within the turbine rotor and includes impingement cooling jets extending through a rear surface of the turbine rotor. An internal cooling manifold extends radially inward of the impingement cooling jets and extends between the base and the rear surface of the turbine rotor. A central nose cooling manifold extends into the central nose and is fluidically connected to the internal cooling manifold. A base cooling manifold is fluidically connected to the central nose manifold and extends radially outward from the central nose cooling manifold. A blade cooling manifold is fluidically connected to the base cooling manifold and extends within the blade. Trailing edge jets extend from the blade cooling manifold and through the trailing edge of blades.

Dai, Zhongtao↗

Additively manufactured radial turbine rotor with cooling manifolds

A turbine rotor includes a base and a plurality of blades. A central nose is radially inward of the blades and defines an axis of rotation. A plurality of cooling manifolds is disposed within the turbine rotor and includes impingement cooling jets extending through a rear surface of the turbine rotor. An internal cooling manifold extends radially inward of the impingement cooling jets and extends between the base and the rear surface of the turbine rotor. A central nose cooling manifold extends into the central nose and is fluidically connected to the internal cooling manifold. A base cooling manifold is fluidically connected to the central nose manifold and extends radially outward from the central nose cooling manifold. A blade cooling manifold is fluidically connected to the base cooling manifold and extends within the blade. Trailing edge jets extend from the blade cooling manifold and through the trailing edge of blades.

Dai, Zhongtao↗

Low‐Volume Cores for Fabrication of Compact, Versatile, and Intelligent Soft Systems

Abstract This study introduces the low‐volume core (LVC) fabrication method, which enables the monolithic molding of compact, complex, versatile, and intelligent soft robotic systems. This method uses thin and flexible thermoplastic sheets to mold internal chambers in soft fluidic actuators, valves, and circuits. The LVC fabrication method creates low‐volume networks in soft actuators (LV‐net actuators) that can be made with compact and complex geometries, enabling both low actuation volume input and multi‐degree‐of‐freedom actuators. LVC fabrication can also be used for compact, completely soft, and monolithic logic components (valves with low‐volume core, also called as LV valves) to provide directional resistance as well as a switching mechanism that enables fluidic logic in soft systems. The compatibility of the fabrication methods for both soft actuators and valves facilitates the creation of compact, integrated, and versatile soft robotic systems with embodied intelligence. This study introduces two examples of such intelligent soft robotic systems that integrate both LV‐net actuators and LV valves to demonstrate capability for complex system fabrication.

Yu, Qifan↗

Self‐Propelling Macroscale Sheets Powered by Enzyme Pumps

Abstract Nanoscale enzymes anchored to surfaces act as chemical pumps by converting chemical energy released from enzymatic reactions into spontaneous fluid flow that propels entrained nano‐ and microparticles. Enzymatic pumps are biocompatible, highly selective, and display unique substrate specificity. Utilizing these pumps to trigger self‐propelled motion on the macroscale has, however, constituted a significant challenge and thus prevented their adaptation in macroscopic fluidic devices and soft robotics. Using experiments and simulations, we herein show that enzymatic pumps can drive centimeter‐scale polymer sheets along directed linear paths and rotational trajectories. In these studies, the sheets are confined to the air/water interface. With the addition of appropriate substrate, the asymmetric enzymatic coating on the sheets induces chemically driven, buoyancy flows that controllably propel the sheet's motion on the air/water interface. The directionality and speed of the motion can be tailored by changing the pattern of the enzymatic coating, type of enzyme, and nature and concentration of the substrate. This work highlights the utility of biocompatible enzymes for generating motion in macroscale fluidic devices and robotics and indicates their potential utility for in vivo applications.

Song, Jiaqi↗

Self‐Propelling Macroscale Sheets Powered by Enzyme Pumps

Nanoscale enzymes anchored to surfaces act as chemical pumps by converting chemical energy released from enzymatic reactions into spontaneous fluid flow that propels entrained nano‐ and microparticles. Enzymatic pumps are biocompatible, highly selective, and display unique substrate specificity. Utilizing these pumps to trigger self‐propelled motion on the macroscale has, however, constituted a significant challenge and thus prevented their adaptation in macroscopic fluidic devices and soft robotics. Using experiments and simulations, we herein show that enzymatic pumps can drive centimeter‐scale polymer sheets along directed linear paths and rotational trajectories. In these studies, the sheets are confined to the air/water interface. With the addition of appropriate substrate, the asymmetric enzymatic coating on the sheets induces chemically driven, buoyancy flows that controllably propel the sheet's motion on the air/water interface. The directionality and speed of the motion can be tailored by changing the pattern of the enzymatic coating, type of enzyme, and nature and concentration of the substrate. This work highlights the utility of biocompatible enzymes for generating motion in macroscale fluidic devices and robotics and indicates their potential utility for in vivo applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Stretchable and wearable polymeric heaters and strain sensors fabricated using liquid metals

Wearable electronic devices (WEDs) are receiving significant attention because of the increasing interest in soft robotics, electronic skin, and wearable sensors. Liquid metals (LMs) are compelling for WEDs owing to their metallic conductivity, fluidic nature, and low toxicity. For this study, we fabricated stretchable and soft WEDs using LM (eutectic gallium-indium alloy) wires (LMWs) patterned via force wetting through custom-made stencils on an elastic substrate. LMWs can generate thermal energy via Joule heating upon current application and deliver it to the substrate, resulting in wearable polymeric heaters. The LM mixed with carbonyl iron particles (CIPs) can also be patterned while preserving fluidic behavior. The degree of thermal energy generated through the LMWs can be manipulated as a function of the CIP concentration in the LM and geometrical factors of the electrode patterns, i.e., width and length. An elastic film patterned with LMWs attached to the human body exhibits changes in the effective electrical resistance depending on applied strain, demonstrating potential as a wearable strain sensor. This LM utilized WED that can generate thermal energy upon current application through the LMWs and detect the bodily motion has significant potential for application in wearable thermotherapy, electronic skin, and soft sensors.

47 OTHER INSTRUMENTATION↗

Salt Sampling FY21 Technical Report

The goal of the salt sampling program at Argonne is to develop and deploy automated molten salt sampling approaches to enable high-precision in-process salt sample analysis to improve the timeliness of sampling-based accountancy measurements. Tools currently under development in support of this goal include (1) a modular vacuum sampler with an accompanying sample handling method for coupling vacuum sampling with high-precision at-line sample analysis, (2) a pneumatic sample generator that enables high-throughput sample analysis to improve the precision of existing analytical techniques, and (3) a windowless flow cell to enable on-line optical analysis of molten salt in a sampling loop. Compared to point sampling approaches (i.e., dip probes), vacuum sampling systems and on-line sampling loops facilitate access to a larger cross-section of a process fluid. This is known to improve the characterization of the process fluid by producing more representative samples and by enabling the analysis of a larger cross section of the fluid. A vacuum sampling approach for molten salts eliminates the risk of dross contamination of samples and avoids the use of moving parts in the salt. In FY21, two methods for integrating a vacuum sampler with a pneumatic sample generator were tested. These included direct fluidic coupling and coupling using a solid salt transfer mechanism. Solid salt transfer was ultimately selected over fluidic coupling, primarily to enable the transport of samples over longer distances to support automated at-line integration with high-precision techniques (such as microcalorimetry) that cannot withstand the extreme conditions near an electrorefining process. To facilitate rapid solid salt coupling, new mechanisms were developed for rapidly charging and discharging salt sample tubes at the vacuum sampler and pneumatic sample generator, respectively. While the charging mechanism will be deployed in FY22, the tube transfer method and discharge mechanism were tested in FY21. These were deployed at one of Argonne’s engineering-scale electrorefiners to implement at-line high-throughput pneumatic micro-sample generation capabilities. The method was used to generate precise uranium- and lanthanide-bearing electrorefiner micro-samples with the specific dimensions requested by researchers at Los Alamos National Laboratory for use in testing their novel microcalorimeter x-ray techniques. The solid salt transfer mechanism proved not only to be an effective means of integrating the precision sample generator with vacuum sampling, but also improved the performance of the sampler generator. Because the modular sampling approach described here eliminates the need for new high-radiation sample handling capabilities, salt-wetted seals, salt-wetted moving parts, and heated transfer lines outside the electrorefiner, it will address most of the remaining technical challenges for the at-line deployment of high-precision analytical techniques. This will enable significant reductions in the time delay for sampling-based accountancy measurements by eliminating the need for manual off-line sample processing and analysis. On-line optical analysis of molten salt in a sampling loop would provide complementary information to at-line and in-situ techniques. In FY21, an open-aperture molten salt gravity flow cell with windowless optical access to flowing salt was successfully demonstrated. Future work should include the refinement and performance testing of the on-line and at-line sampling tools, integration of additional analysis techniques, stakeholder outreach and collaboration, evaluation of the integrated methods, and analyses to determine how the various tools might fit into an integrated safeguards monitoring system of unattended near real time monitoring tools.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Deployment of salt sample extraction system at an engineering-scale electrorefiner

The goal of the salt sampling program at Argonne is to develop and deploy automated molten salt sampling approaches for interfacing relevant unit operations with salt analysis to improve the timeliness of sampling-based accountancy measurements. Two technologies under development in support of this goal are a vacuum sampling loop module and a high-throughput pneumatic sample generator module. Compared to traditional point sampling approaches (i.e., dip probes), the vacuum sampling loop facilitates the collection of a larger cross-section of the bulk salt in order to collect more representative samples. The vacuum sampling approach also eliminates the risk of dross contamination of samples and avoids the use of moving parts in the salt. The pneumatic sample generator module is used to facilitate high-throughput sample analysis to improve the measurement precision of any given analytical technique by averaging out random sampling and measurement errors. In FY21, two methods for integrating these two modules were tested including direct fluidic coupling and coupling using a solid salt transfer mechanism. Solid salt transfer was ultimately selected over fluidic coupling, primarily to enable the transport of samples over longer distances to support automated at-line integration with high-precision techniques (such as microcalorimetry) that cannot withstand the conditions near an electrorefining process. To facilitate rapid solid salt coupling, new mechanisms were developed for rapidly charging and discharging salt sample tubes at the vacuum sampling loop and pneumatic sample generator modules, respectively. While the charging mechanism will be deployed in FY22, the discharge mechanism was tested in FY21 and is described here. The solid salt tube transfer method was deployed at one of Argonne’s engineering-scale electrorefiners to implement at-line high-throughput pneumatic micro-sample generation capabilities. The approach was used to generate precise uranium- and lanthanide-bearing electrorefiner micro-samples with the specific dimensions requested by researchers at Los Alamos National Laboratory for use in testing their novel microcalorimeter x-ray techniques. The solid salt transfer mechanism proved not only to be an effective means of integrating the precision sample generator with vacuum sampling, but also improved the performance of the sampler generator. To discharge salt from the sample tubes at the sampler generator, tube segments were inserted directly into the sample generator’s Helmholtz chamber and pressure pulse actuations were used to generate precision molten salt samples directly from the tube segments. The direct insertion of sample tubes into the sample generator enabled rapid loading of the salt and prevented salt from contacting most of the interior surfaces of the sample generator, which eliminated cross-contamination between runs. The vacuum sampling-loop tube charging mechanism will support high-throughput tube sampling operations by employing a dynamic vacuum filling process to fill short charge tubes that are configured to be rapidly connected and disconnected from the loop. The dynamic vacuum sampling operation will be automated, and sample tube handling can be executed with simple overhead actuation. Because the modular sampling approach described here eliminates the need for new high-radiation sample handling capabilities, salt-wetted seals, salt-wetted moving parts, and heated transfer lines outside the electrorefiner, it will address most of the remaining technical challenges for the at-line deployment of high-precision analytical techniques which will enable significant reductions in the time delay for sampling-based high-precision accountancy measurements.

42 ENGINEERING↗

Ferromagnetic-fluid logic devices

Logic element switches flows of low pressure process control fluid in fluidics assemblies. Device operates both electrically and fluidically and is controlled by passing permanent magnet or electromagnet over elements, thus providing proximity switching functions.

Makowski, M. J.↗

Investigation of propellant flow control system

Mechanical, electromechanical, and fluidic concepts were studied as propellant flow control system for oxygen/hydrogen attitude control thrusters. A mechanical flow controller was designed, fabricated, and tested with hydrogen, oxygen, and nitrogen over a range of inlet pressures and temperatures. Results of these tests are presented along with a discussion of a flight-weight design. Also presented are recommendations for further design and development. A detailed coverage of the fluidics investigation is included.

Liebman, A. A.↗

Turbine gas temperature measurement and control system

A fluidic Turbine Inlet Gas Temperature (TIGIT) Measurement and Control System was developed for use on a Pratt and Whitney Aircraft J58 engine. Based on engine operating requirements, criteria for high temperature materials selection, system design, and system performance were established. To minimize development and operational risk, the TIGT control system was designed to interface with an existing Exhaust Gas Temperature (EGT) Trim System and thereby modulate steady-state fuel flow to maintain a desired TIGT level. Extensive component and system testing was conducted including heated (2300F) vibration tests for the fluidic sensor and gas sampling probe, temperature and vibration tests on the system electronics, burner rig testing of the TIGT measurement system, and in excess of 100 hours of system testing on a J58 engine. (Modified author abstract)

Webb, W. L.↗

Entrainment characteristics of unsteady subsonic jets

The effectiveness of jet unsteadiness in enhancing flow entrainment was assessed. It was conducted that entrainment depends on the type and amount of jet unsteadiness. Apparently, the mere introduction of jet unsteadiness by small sinusoidal flow angle variations is insufficient to enhance entrainment but, it should be noted that the results were obtained at measuring stations which are all many nozzle widths downstream of the jet nozzle. Thus, no fully conclusive statement can be made at this time about the entrainment close to the nozzle. The high entrainment of the fluidically oscillated jet was caused by the high-frequency content of this square wave type of oscillation but more detailed measurements are clearly needed, in particular for the fluidically oscillated and the pulsed jets. Practical ejector application requires the proper trade-off between entrainment and primary nozzle thrust efficiency.

Platzer, M. F.↗

The flip-flop nozzle extended to supersonic flows

An experiment studying a fluidically oscillated rectangular jet flow was conducted. The Mach number was varied over a range from low subsonic to supersonic. Unsteady velocity and pressure measurements were made using hot wires and piezoresistive pressure transducers. In addition smoke flow visualization using high speed photography was used to document the oscillation of the jet. For the subsonic flip-flop jet it was found that the apparent time-mean widening of the jet was not accompanied by an increase in mass flux. It was found that it is possible to extend the operation of these devices to supersonic flows. Most of the measurements were made for a fixed nozzle geometry for which the oscillations ceased at a fully expanded Mach number of 1.58. By varying the nozzle geometry this limitation was overcome and operation was extended to Mach 1.8. The streamwise velocity perturbation levels produced by this device were much higher than the perturbation levels that could be produced using conventional excitation sources such as acoustic drivers. In view of this ability to produce high amplitudes, the potential for using small scale fluidically oscillated jet as an unsteady excitation source for the control of shear flows in full scale practical applications seems promising.

Raman, Ganesh↗

The flip flop nozzle extended to supersonic flows

An experiment studying a fluidically oscillated rectangular jet flow was conducted. The Mach number was varied over a range from low subsonic to supersonic. Unsteady velocity and pressure measurements were made using hot wires and piezoresistive pressure transducers. In addition smoke flow visualization using high speed photography was used to document the oscillation of the jet. For the subsonic flip-flop jet it was found that the apparent time-mean widening of the jet was not accompanied by an increase in mass flux. It was found that it is possible to extend the operation of these devices to supersonic flows. Most of the measurements were made for a fixed nozzle geometry for which the oscillations ceased at a fully expanded Mach number of 1.58. By varying the nozzle geometry this limitation was overcome and operation was extended to Mach 1.8. The streamwise velocity perturbation levels produced by this device were much higher than the perturbation levels that could be produced using conventional excitation sources such as acoustic drivers. In view of this ability to produce high amplitudes, the potential for using small scale fluidically oscillated jet as an unsteady excitation source for the control of shear flows in full scale practical applications seems promising.

Raman, Ganesh↗