Search NASA⌕ Search

SEARCH · Search NASA

Results for “GAS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

In-Situ and Ex-Situ Studies on the Morphology Changes of Polymer Pipeline Materials for Use in Hydrogen Gas Environments

The US natural gas infrastructure is a national asset that could be used to deliver hydrogen and hydrogen blends of natural gas as a pathway to reduce carbon emissions. The distribution system comprises nearly 50% plastic pipe composed of medium- and high-density polyethylene materials (MDPE and HDPE). While these materials perform adequately for natural gas, research on their hydrogen compatibility is essential to understand if any immediate and long-term risks are associated with hydrogen addition. The Blended Gas CRADA, a HyBlend project, has established a comprehensive test method for evaluating MDPE and HDPE of various plastic resin compositions of pipeline material in pure hydrogen and 20% hydrogen/80% methane blends. Both in-situ and ex-situ measurements were performed to capture hydrogen-induced changes in the polyethylene material's crystalline, amorphous and their interphase regions. We investigated MDPE and HDPE pipeline materials made from different polymer resin systems to evaluate the effects of hydrogen gas. The materials were characterized by their density, diffusion coefficient, free volume ratio, and degree of crystallinity. Various advanced characterization methods, including in situ NMR, ex situ XRD, ex situ DSC, and ex situ TDA, were used to analyze the effects of changes in crystalline, amorphous, and interphase regions due to gas exposure. Time-dependent post-decompression quasi-static tensile tests were conducted to explore the effects of gas exposure time on the mechanical behavior of the pipe materials. This work will highlight the time sensitivities during and after gas exposure. The correlation between gas-induced polyethylene morphology changes and the associated material performance will be addressed for the intended applications. These studies will show that polyethylene resin composition and material exposure are important factors when considering whether hydrogen gas affects pipeline materials positively or negatively.

Simmons, Kevin L.↗

Porous Organic Cage Membranes for Molecular Gas Separations (Final Technical Report for DE-SC0021357)

This proposal aims at demonstrating the development of a novel family of membranes, composed of porous organic cages (POC) which offer the possibility of displaying high separation performance for challenging molecular gas separations relevant to natural gas purification, and olefin/paraffin separation. The proposed POCs synthesized in membrane form will display the most desirable properties of polymers (facile processability and flexibility) and inorganic materials (hierarchically ordered pores with molecular sieving properties) leading to highly selective and permeable membranes. POCs should display distinctive structural, compositional, adsorption and transport properties than those of conventional porous materials, opening the doors for a new research direction in membrane science, and gas separations. Our preliminary results demonstrate the feasibility of preparing POC crystals with controlled size, and continuous POC membranes with remarkable high permeances, and separation ability for CO 2 /CH 4 , N 2 /CH 4 and C 3 H 6 /C 3 H 8 separations serving as a solid foundation for our proposed work. Fundamentally, this proposal aims at elucidating separation mechanisms of different gas mixtures related to natural gas composition, and olefin/paraffin separation over porous organic cage membranes. The proposed research will result in fundamental understanding of adsorption and transport properties of industrially relevant gas molecules through novel microporous membranes, and may lead to the development of a cost effective membrane technology for natural gas purification, and olefin/paraffin separation surpassing the conventional benchmark technology distillation. Furthermore, we aim at demonstrating selective water transport through POC membranes, which can be positively impactful in numerous industrial applications in which water is present. The ability to fabricate thin, chemically and mechanically stable POC membranes for societal relevant gas separations constitute a new and distinctive direction in membrane science. Our proposed work aims at addressing some of the challenges recognized in the Research Agenda for Transforming Separation Science . Specifically: (a) advancing understanding of complex mixtures on separation performance; (b) exploring thermodynamic and kinetic mechanisms through the elucidation of separation mechanisms, and (c) study potential stability issues of the membranes to be assessed by evaluating the long term membrane stability and performance at various temperatures and pressures. The team is uniquely qualified to execute the proposed work. The PI has solid expertise in the rational molecular engineering design of porous crystalline membranes for molecular gas separations. The PNNL collaborator has extensive experience in the synthesis, characterization, and functional applications of microporous crystals, with particular emphasis on gas adsorption.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Joint X-Ray, Kinetic Sunyaev–Zeldovich, and Weak Lensing Measurements: Toward a Consensus Picture of Efficient Gas Expulsion from Groups and Clusters

There is no consensus on how baryon feedback shapes the underlying matter distribution from either simulations or observations. We confront the uncertain landscape by jointly analyzing new measurements of the gas distribution around groups and clusters—DESI+ACT kinetic Sunyaev–Zel’dovich (kSZ) effect profiles and eROSITA X-ray gas masses—with mean halo masses characterized by galaxy–galaxy lensing. Across a wide range of halo masses ( M 500 = 10 13−14 M ⊙ ) and redshifts (0 < z < 1), we find evidence of more efficient gas expulsion beyond several R 500 than predicted by most state-of-the-art simulations. A like-with-like comparison reveals all kSZ and X-ray observations are inconsistent with the fiducial 1 Gpc 3 hydrodynamical FLAMINGO simulation, which was calibrated to reproduce pre-eROSITA X-ray gas fractions: eROSITA X-ray gas fractions are 2 × lower than the simulation, and the kSZ measurements are combined >8σ discrepant. The FLAMINGO simulation variant with the most gas expulsion, and therefore the most suppression of the matter power spectrum relative to a dark-matter-only simulation, provides a good description of how much gas is expelled and how far it extends; the enhanced gas depletion is achieved by more powerful but less frequent AGN outbursts. Joint kSZ, X-ray, and lensing measurements form a consistent picture of gas expulsion beyond several R 500 , implying a more suppressed matter power spectrum than predicted by most recent simulations. Complementary observables (e.g., thermal Sunyaev–Zel’dovich effect and fast radio bursts) and next-generation simulations are critical to understanding the physical mechanism behind this extreme gas expulsion and mapping its impact on the large-scale matter distribution.

79 ASTRONOMY AND ASTROPHYSICS↗

Response of GAS payload (G345 and G347) temperatures to various orbiter flight attitudes

At the beginning of the Get-Away Special (GAS) flight program, the GAS Project flew a Flight Verification Payload on STS-3 to make measurements of the vibrations, acoustic and magnetic environments of the canister, and to obtain thermal profiles of internal and external components of the GAS system. These data were used to verify pre-flight thermal models of the GAS system and results have been published in a GSFC Technical Note, X-732-83-8 (Butler, 1983). On somewhat later flights of the Orbiter, STS-7 and STS-8, the Naval Research Laboratory and the Goddard Space Flight Center jointly developed and flew a GAS payload whose primary objective was to evaluate the performance of ultraviolet-sensitive (Schumann) photographic emulsions in the Orbiter environment, including pre-flight integration, on-orbit exposure to the ambient environment of the Orbiter bay and post-flight conditions before removal of the experiment from the vehicle. These emulsions, used in spectrographs to record solar radiations with wavelengths between 100 A and 2000 A, have low gelatin content and no protective gelatin overcoating in order to maximize their UV sensitivity. Consequently, they are extremely sensitive to environmental conditions. Furthermore, they are exposed directly to space during the observations because any intervening protective window or lense would completely absorb the radiations to be studied. which was prepared at the Naval Research Laboratory under the direction of Robert Kreplin (Kreplin et al., 1984 a) also included two thermal sensors, whose output was recorded once an hour with a precision of 0.7O C. The experiment operated nominally on both missions and provided important data confirming that W - sensitive emulsions could tolerate integration and flight on the Shuttle with relatively little deterioration. The results of these studies have already been reported (Kreplin et al, 1984 b). The temperature measurements also were recorded successfully and are the basis for this paper. They are a useful complement to the thermal observations made on STS-3 and provide additional insight into the reaction of a payload to typical thermal environments that GAS experiments are subject to. Our GAS experiment and the circumstances of its flights were particularly useful in terms of modeling the thermal response of the GAS canister and our instrument. The Orbiter was held (except for interruptions for star tracker alignment, satellite deployments, etc., in specific attitudes for sufficiently long periods of time that the thermal response of the instrument to each attitude was well measured. Two types of GAS canister end cap, one, the insulated end cap and the other a silverized teflon covered end-cap, were used on the two flights so that a direct comparison of the thermal performance of the two types was obtained. This report is an attempt to compare these observations with a simple thermal model of the instrument in the GAS canister in order to assess whether such simple models can be useful to experimenters in predicting the thermal response of their payloads.

Werner M. Neuper↗

Cold, warm, and hot gas in the late-stage merger NGC 7252

We present the first observations of the neutral hydrogen distribution and x-ray emission in the prototypical merger remnant NGC 7252, the 'Atoms-for-Peace' galaxy. These data are supplemented by accurate B and R surface photometry, reaching a limit of mu(sub B) = 26.5 mag/sq arcsec, and images taken through a narrow-band H alpha filter. We find all of the 2 x 10(exp 9)/sq h solar mass of atomic gas to be restricted to the outer, tidal regions of this system (H(sub zero) = 100 h km/s/Mpc). By contrast, the molecular gas traced by the (12)CO(1 approaches zero) map of Wang et al. (1992) is confined to an inner rotating disk of radius 7 seconds and has an H alpha counterpart. The gap between the atomic and molecular gas distributions is filled in by diffuse H alpha emission and perhaps by x-ray emission. The velocity field of the atomic gas in the tidal tails indicates that they are swinging through space in the same sense as the rotation of the inner gas disk. The H I at the apparent base of the northwestern tail seems to be falling back toward the main body of the galaxy, yet there is no H I associated with this main stellar body: This suggests ongoing efficient conversion of the atomic gas into other phases in this region. The H alpha velocity anomalies previously found in the remnant body may be produced in part by the combination of tail-related, noncircular motions and the inner gas-disk rotation. Both tidal tails have bluer B-R colors than the main body of the remnant, with the bluest regions coinciding with peaks in the gas column density. Each tail contains one giant H II region near the end of its optical light distribution. These H II regions are associated with large concentrations of gas and stars that approach the sizes and gas contents of dwarf galaxies. The H I extends beyond the end of the optical tails and reaches projected distances of 62/h kpc east and 120/h kpc northwest from the center. We discuss the possible relevance of these data to : (1) the transformation of merged spirals into ellipticls; (2) the generation of ripples by returning tidal material; and (3) the formation of bound stellar systems from tidally torn material.

Hibbard, J. E.↗

The New Heavy Gas Testing Capability in the NASA Langley Transonic Dynamics Tunnel

The NASA Langley Transonic Dynamics Tunnel (TDT) has provided a unique capability for aeroelastic testing for over thirty-five years. The facility has a rich history of significant contributions to the design of many United States commercial transports and military aircraft. The facility has many features which contribute to its uniqueness for aeroelasticity testing; however, perhaps the most important facility capability is the use of a heavy gas test medium to achieve higher test densities. Higher test medium densities substantially improve model building requirements and therefore simplify the fabrication process for building aeroelastically scaled wind-tunnel models. The heavy gas also provides other testing benefits, including reduction in the power requirements to operate the facility during testing. Unfortunately, the use of the original heavy gas has been curtailed due to environmental concerns. A new gas, referred to as R-134a, has been identified as a suitable replacement for the former TDT heavy gas. The TDT is currently undergoing a facility upgrade to allow testing in R-134a heavy gas. This replacement gas will result in an operational test envelope, model scaling advantages, and general testing capabilities similar to those available with the former TDT heavy gas. As such, the TDT is expected to remain a viable facility for aeroelasticity research and aircraft dynamic clearance testing well into the 21st century. This paper describes the anticipated advantages and facility calibration plans for the new heavy gas and briefly reviews several past test programs that exemplify the possible benefits of heavy gas testing.

Cole, Stanley R.↗

Membrane-Based Gas Traps for Ammonia, Freon-21, and Water Systems to Simplify Ground Processing

Gas traps are critical for the smooth operation of coolant loops because gas bubbles can cause loss of centrifugal pump prime, interference with sensor readings, inhibition of heat transfer, and blockage of passages to remote systems. Coolant loops are ubiquitous in space flight hardware, and thus there is a great need for this technology. Conventional gas traps will not function in micro-gravity due to the absence of buoyancy forces. Therefore, clever designs that make use of adhesion and momentum are required for adequate separation, preferable in a single pass. The gas traps currently used in water coolant loops on the International Space Station are composed of membrane tube sets in a shell. Each tube set is composed of a hydrophilic membrane (used for water transport and capture of bubbles) and a hydrophobic membrane (used for venting of air bubbles). For the hydrophilic membrane, there are two critical pressures, the pressure drop and the bubble pressure. The pressure drop is the decrease in system pressure across the gas trap. The bubble pressure is the pressure required for air bubbles to pass across the water filled membrane. A significant difference between these pressures is needed to ensure complete capture of air bubbles in a single pass. Bubbles trapped by the device adsorb on the hydrophobic membrane in the interior of the hydrophilic membrane tube. After adsorption, the air is vented due to a pressure drop of approximately 1 atmosphere across the membrane. For water systems, the air is vented to the ambient (cabin). Because water vapor can also transport across the hydrophobic membrane, it is critical that a minimum surface area is used to avoid excessive water loss (would like to have a closed loop for the coolant). The currently used gas traps only provide a difference in pressure drop and bubble pressure of 3-4 psid. This makes the gas traps susceptible to failure at high bubble loading and if gas venting is impaired. One mechanism for the latter is when particles adhere to the hydrophobic membrane, promoting formation of a water layer about it that can blind the membrane for gas transport (Figure 1). This mechanism is the most probable cause for observed failures with the existing design. The objective of this project was to devise a strategy for choosing new membrane materials (database development and procedure), redesign of the gas trap to mitigate blinding effects, and to develop a design that can be used in ammonia and Freon-21 coolant loops.

Ritchie, Stephen M. C.↗

Recent Operational Experience with the Internal Thermal Control System Dual-Membrane Gas Trap

A dual-membrane gas trap is currently used to remove gas bubbles from the Internal Thermal Control System (ITCS) coolant on board the International Space Station. The gas trap consists of concentric tube membrane pairs, comprised of outer hydrophilic tubes and inner hydrophobic fibers. Liquid coolant passes through the outer hydrophilic membrane, which traps the gas bubbles. The inner hydrophobic fiber allows the trapped gas bubbles to pass through and vent to the ambient atmosphere in the cabin. The gas removal performance and operational lifetime of the gas trap have been affected by contamination in the ITCS coolant. However, the gas trap has performed flawlessly with regard to its purpose of preventing gas bubbles from causing depriming, overspeed, and shutdown of the ITCS pump. This paper discusses on-orbit events over the course of the last year related to the performance and functioning of the gas trap.

Leimkuehler, Thomas O.↗

Trapping of gas mixtures by amorphous water ice

Our studies on gas trapping in amorphous water ice at 24-100 K were extended, by using mixtures of CH4, CO, N2, and Ar, rather than single gases. In 1:1 gas:(water vapor) mixtures, the competition among these gases on the available sites in the ice showed that the trapping capacity for the various gases is determined not only by the structure and dynamics of the ice, but is also influenced by the gas itself. Whereas at 24-35 K all four gases are trapped in the ice indiscriminantly, at 50-75 K there is a clear enhancement, in the order of CH4 > CO > N2 > or approximately Ar. This order is influenced by the gas-water interaction energy, the size of the trapped gas atom or molecule, the type of clathrate-hydrate formed (I or II) and, possibly, other factors. It seems that the gas can be trapped in the amorphous ice in several different locations, each being affected in a different way by the deposition temperature and gas composition. Once a gas atom or molecule is trapped in a specific location, it is predestined to emerge in one of eight different temperature ranges, which are associated with changes in the ice. The experimentally observed enhancements, together with the findings on the gas composition of comet Halley, might enable an estimation of the gas composition in the region of comet formation.

NASA Discipline Number 52-10↗

Real-time exhaust gas modular flowmeter and emissions reporting system for mobile apparatus

A real-time emissions reporting system includes an instrument module adapted to be detachably connected to the exhaust pipe of a combustion engine to provide for flow of exhaust gas therethrough. The instrument module includes a differential pressure probe which allows for determination of flow rate of the exhaust gas and a gas sampling tube for continuously feeding a sample of the exhaust gas to a gas analyzer or a mounting location for a non-sampling gas analyzer. In addition to the module, the emissions reporting system also includes an elastomeric boot for detachably connecting the module to the exhaust pipe of the combustion engine, a gas analyzer for receiving and analyzing gases sampled within the module and a computer for calculating pollutant mass flow rates based on concentrations detected by the gas analyzer and the detected flowrate of the exhaust gas. The system may also include a particulate matter detector with a second gas sampling tube feeding same mounted within the instrument module.

Breton, Leo Alphonse Gerard↗

Central Africa Energy: Utilizing NASA Earth Observations to Explore Flared Gas as an Energy Source Alternative to Biomass in Central Africa

Much of Central Africa's economy is centered on oil production. Oil deposits lie below vast amounts of compressed natural gas. The latter is often flared off during oil extraction due to a lack of the infrastructure needed to utilize it for productive energy generation. Though gas flaring is discouraged by many due to its contributions to greenhouse emissions, it represents a waste process and is rarely tracked or recorded in this region. In contrast to this energy waste, roughly 80% of Africa's population lacks access to electricity and in turn uses biomass such as wood for heat and light. In addition to the dangers incurred from collecting and using biomass, the practice commonly leads to ecological change through the acquisition of wood from forests surrounding urban areas. The objective of this project was to gain insight on domestic energy usage in Central Africa, specifically Angola, Gabon, and the Republic of Congo. This was done through an analysis of deforestation, an estimation of gas flared, and a suitability study for the infrastructure needed to realize the natural gas resources. The energy from potential natural gas production was compared to the energy equivalent of the biomass being harvested. A site suitability study for natural gas pipeline routes from flare sites to populous locations was conducted to assess the feasibility of utilizing natural gas for domestic energy needs. Analyses and results were shared with project partners, as well as this project's open source approach to assessing the energy sector. Ultimately, Africa's growth demands energy for its people, and natural gas is already being produced by the flourishing petroleum industry in numerous African countries. By utilizing this gas, Africa could reduce flaring, recuperate the financial and environmental loss that flaring accounts for, and unlock a plentiful domestic energy source for its people. II. Introduction Background Africa is home to numerous burgeoning economies; a significant number rely on oil production as their primary source of revenue. Relative to its size and population density, the continent has a wealth of natural resources, including oil and natural gas deposits. The exploration of these resources is not a new endeavor, but rather one that spans decades, up to a century in some places. Their resources, if realized, could provide a great means of economic and social mobility for the people of Africa. Currently, Africa represents about 12 % of the energy market, yet at the same time, consumes only 3 % of the world's energy (Kasekende 2009). The higher

Jones, Amber↗

Apparatuses and methods for gas flux measurements

Embodiments of the disclosure are drawn to apparatus and methods for determining gas flux measurements. A gas plume may be emitted from a source and may be blown by wind in an environment. A measurement system, such as a light detection and ranging (lidar) system may collect a plurality of gas concentration measurements associated with the gas plume at a plurality of locations in the environment. A gas flux may be determined based on one or more of the gas concentration measurements along with a wind speed at a location associated with the gas plume. In some embodiments, a height of the gas plume may be determined, and the wind speed at the height of the gas plume may be determined and used to determine the gas flux.

Thorpe, Michael James↗

Exploring the Use of Non‐Invasive Drone‐Based Ground‐Penetrating Radar (GPR) to Characterize Biogenic Gas Dynamics in Subtropical Peat Soils

Peat soils are a critical component of the global carbon cycle as natural producers of biogenic greenhouse gases (e.g., methane and carbon dioxide) that accumulate within the soil and are released to the atmosphere. Previous studies have showed the ability of ground-based minimally-invasive geophysical methods such as ground-penetrating radar (GPR) to characterize carbon dynamics in peat soils. However, ground-based GPR is limited by scale of measurement and soil disturbance potentially altering gas releases during deployment. Here, we explore the potential of drone-based GPR for identification of hot spots and hot moments of gas accumulation and release in subtropical soils. Here, we collected drone-based GPR data sets across two grids (∼17,500 m 2 ) in the Everglades during January (dry season), September, and November (wet season) of 2023 to characterize peat thickness and seasonal variability of gas content. Results show that drone-based GPR is effective and efficient for: (a) capturing the temporal variation of in situ biogenic gas content in peat soils with changes between 1% and 25 % volumetric gas content over repeatable grids; (b) inferring a total peat thickness between 0.8 and 1.2 m; and (c) estimating flux releases of 63 and 135 mg CH 4 m −2 day −1 for specific locations and periods that are strikingly consistent with our coincident gas trap measurements. This work also indicates that (a) spatial distribution of gas content in the Everglades is strongly controlled by landscape morphology such as ridges and sloughs and (b) the temporal variation of gas content is seasonal with increased gas production during the wet season.

54 ENVIRONMENTAL SCIENCES↗

Techno-Economic Analysis of Repurposing Natural Gas Transmission Pipeline Networks to Accommodate Hydrogen Blends

Blending hydrogen into natural gas infrastructure could supplement natural gas supply and increase resilience for applications such as ammonia production, peaking and load-following power plants, and heating. The United States has an extensive network of natural gas pipelines, but the feasibility of employing this infrastructure to transport hydrogen is unclear. We analyze the costs associated with repurposing three distinct natural gas transmission pipelines in different locations within the United States to carry blends of hydrogen up to 100% via three different pipeline network modification methods and compare against the cost of building a new dedicated hydrogen pipeline. We conduct a sensitivity analysis on the hoop stress limit of the existing pipe, techno-economic parameters, emissions, and relative capacity. The results show that the capital costs required to upgrade a pipeline can vary from tens of millions to billions of dollars depending on the length and capacity of the existing pipeline section, whether the existing pipeline already operates at or below its maximum allowable operating pressure, whether future demand is expected to increase or decrease, the network modification method selected, and pipe material costs. The delivered cost of energy to end users is impacted less by the levelized cost of transporting hydrogen blends than by the cost of the natural gas and hydrogen fuels being transported. The emissions impact of blending hydrogen into natural gas transmission networks scales proportionally with the amount of energy displaced with low-emission hydrogen (such as from natural gas with carbon capture and sequestration or electrolysis powered by nuclear, renewable, or geothermal electricity), therefore low blend ratios (e.g., < 20% vol. hydrogen) will result in low emissions impacts. Factors such as permitting and right-of-way costs, the proximity of the pipeline to hydrogen demand and production, and the compatibility of and/or retrofitting costs of end-use gas-fueled technologies will likely be greater drivers in determining whether converting a particular natural gas pipeline to carry hydrogen makes economic sense.

08 HYDROGEN↗

Primordial or Secondary? Testing Models of Debris Disk Gas with ALMA

The origin and evolution of gas in debris disks are still not well understood. Secondary gas production from cometary material or a primordial origin have been proposed. So far, observations have mostly concentrated on CO, with only a few C observations available. We overview the C and CO content of debris disk gas and test the state of the-art models. We use new and archival Atacama Large Millimeter/submillimeter Array (ALMA) observations of CO and C I emission, complemented by C II data from Herschel, for a sample of 14 debris disks. This expands the number of disks with ALMA measurements of both CO and C I by 10 disks. We present new detections of C I emission toward three disks: HD 21997, HD 121191, and HD 121617. We use a simple disk model to derive gas masses and column densities. We find that current state-of-the-art models of secondary gas production overpredict the C 0 content of debris disk gas. This does not rule out a secondary origin, but might indicate that the models require an additional C removal process. Alternatively, the gas might be produced in transient events rather than a steady-state collisional cascade. We also test a primordial gas origin by comparing our results to a simplified thermochemical model. This yields promising results, but more detailed work is required before a conclusion can be reached. Our work demonstrates that the combination of C and CO data is a powerful tool to advance our understanding of debris disk gas.

Radiative transfer↗

Generalizable Porous Aromatic Framework‐Included Polymer Membranes for Diffusion‐Enhanced Gas Separations

Industrial separation processes account for 10-15% of global energy consumption. Membrane-based processes are less energy-intensive than traditional gas separation technologies; however, enhanced material separation performance and stability for numerous gas mixtures are needed for widespread industrial adoption. This work presents a generalizable strategy for preparing mixed-matrix gas separation membranes exceeding the performance upper bounds of existing polymer membranes for a wide variety of industrial gases. By incorporating robust porous aromatic framework (PAF) particles into various dense commercial polymer matrices, gas diffusivity and solubility can be enhanced. For diverse gas mixtures (e.g., CO2/N2, O2/N2, He/CH4, H2/N2, and C2H4/C2H6), the resulting composite membranes exhibit enhanced gas permeabilities-by as much as 520%-and largely unchanged selectivities even after 6 years of aging under simulated flue gas conditions. These improvements arise from the ultrahigh porosity, excellent chemical compatibility, and unique physicochemical properties of the embedded PAF particles. Functionalizing the PAFs with polyamines also enables composite membranes that achieve among the highest reported performances against plasticization, a common obstacle in commercializing gas separation membranes. Significantly, the PAF-1 particles are readily dispersible in various common membrane casting solvents, suggesting their broader utility as a filler for designing high-performance membranes for many industrial gas separations.

Uliana, Adam A↗

Transient plasma-detachment events induced by multiple gas puffs in ADITYA-U tokamak

Application of periodic short bursts of gas leads to periodic separation of the plasma column edge from the limiter in the Ohmically heated discharges of ADITYA-U tokamak. After every gas-puff, injecting around 10 17 –10 18 m −3 molecules of fuel gas in the edge of the plasma column, a significant reduction in plasma density, temperature, H α emission intensity and an increase in the H β /H α ratio is observed in the vicinity of the limiter radius for a certain time duration before these parameters regain their pre-gas puff values. A decline in the ion-flux to the limiter is also observed simultaneously. The global confinement of plasma also increases after each gas-puff. These observations, which repeat after each gas-injection, imply that the plasma–neutral interaction occurs further away from the limiters after the gas-injection and indicate a periodic plasma separation from the limiter surface. Further investigation revealed that the gas-injection modifies the radial and toroidal electric field, which may be playing a role in the separation of the plasma column from the limiter surface. It was further demonstrated by an electrode bias experiment in the absence of gas-injection that an application of an external radial electric field can result in obtaining a separated plasma state.

Physics - Plasma physics↗

Gas-Gap Calorimeter Sizing and Rating Tools for Heat Pipe Experimentation

Effective gas-gap calorimeter sizing and rating tools are required to design calorimeters that enable well-defined operating conditions, high cooling powers, and accurate calorimetry. The present report describes two tools utilizing Microsoft Excel and MathWorks MATLAB that enable the sizing and rating of gas-gap calorimeters with a He-Ar binary gas mixture in the gap. The Excel tools are two easy-to-use spreadsheets for calculating heat pipe operating temperature or He-Ar mole fractions given the required inputs. The MATLAB tool includes similar models with more robust solution algorithms along with sub-options for full-vacuum, static gas-gap, and forced circulation in the gas-gap. The accuracy of the developed tools were demonstrated by comparing with existing work in literature. The MATLAB tool was used for a parametric study to determine the gas-gap thickness, coolant gap thickness, coolant flow rate, and coolant inlet temperatures for the testing of a 3/4 in outer diameter heat pipe up to powers of 10 kW and temperatures of 1,000°C. The effects of heat pipe and calorimeter inner shell surface emissivities were investigated, considering the inability to control or accurately measure surface emissivities in most applications. It was found that controlling the He-Ar mole fractions provides a wide operating range for gas-gap thicknesses around ~ 0.042--0.090 in (~ 1.07--2.29 mm) for a surface emissivity range of 0.4--0.8, since conduction heat transfer is a significant fraction of the heat transfer across the gas-gap. In addition, it was found that turbulent flow in the coolant gap is needed at high input powers to prevent shell temperatures from approaching the boiling temperature of the water coolant. The parametric study resulted in choosing stainless steel tubes with an outer diameter and thickness of 1 x 0.065 in as the inner shell, and a 1-1/2 x 0.156 in as the outer shell of the calorimeter. Overall, this report presents the necessary information for the sizing and rating of gas-gap calorimeters with He-Ar mixtures for the testing of high-temperature heat pipes (~ 500--1,000°C).

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗