Enhanced material identification via momentum-integrated muon scattering tomography

Cosmic ray muons, originating from interactions in the upper atmosphere, possess high energy and unique penetrative capabilities suitable for non-traditional radiographic inspection. This study explores their application in various fields such as nuclear fuel cask monitoring, nuclear reactor imaging, and archaeology, leveraging the principle of multiple Coulomb scattering for imaging dense materials. While muon scattering tomography has shown promise, accurately measuring muon momentum remains challenging. This research introduces the Momentum Integrated Point-of-Closest Approach (mPoCA) algorithm, integrating muon momentum data into the traditional Point-of-Closest Approach (PoCA) framework. Utilizing the Cherenkov muon spectrometer, renowned for precise muon momentum estimation, the mPoCA algorithm offers a novel imaging approach. Simulations conducted with GEANT4 evaluate the mPoCA algorithm’s performance against the standard PoCA method, demonstrating superior image resolution and enhanced material identification capabilities, particularly in distinguishing materials like uranium and lead. These findings underscore the potential of the mPoCA algorithm for advancing muon scattering tomography applications.

36 MATERIALS SCIENCE↗

Cherenkov and Transition Radiation as Low-Energy Background Sources in SuperCDMS Detectors

The Weakly Interacting Massive Particle (WIMP) has historically been a prime candidate for dark matter due to its elegant compatibility with the Minimally Supersymmetric Standard Model (MSSM). Recent dark matter experiments have ruled out much of the GeV-TeV mass range predicted by the MSSM, however, and the newest generation of direct detection experiments, such as SuperCDMS SNOLAB, have begunto explore sub-GeV dark matter. As experiments push towards lower masses, sensitivity to eV-scale electron recoil events has become increasingly important. A variety of unexplained excesses at energy deposits of 1-100 eV have been found inmany such low-mass experiments, across different detection techniques and at different excess rates. These low-energy events are not thought to be dark matter, and they must be understood and effectively removed to further improve detector energy resolution. This thesis will outline the simulation of one possible source of low-energy excess at SuperCDMS: optical photons produced from charges in uniform motion, specifically from Cherenkov radiation (CR), transition radiation (TR), and the intermediate hybrid transition-Cherenkov radiation (HR). In the latter case, the standard formulae for HR contain divergences at certain angles in transparent media, which are an artifact of their derivation and become problematic to simulate. To rsolve this, we present a novel approach to normalize the divergent HR peaks, which allows HR to transition smoothly between TR and CR in a numerical simulation. We also add TR and CR as a physics process to the SuperCDMS Monte Carlo simulation package SuperSim, based on the Geant4 simulation toolkit. To verify the physics of our addition, we show some test simulations in comparison to theoretical predictions of optical radiation intensity. We also use the simulation to make some preliminary predictions on the contribution of TR and CR to the low energy background, with the expectation that more thorough analyses will be conducted in the future.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Compton transmission polarimeter for DC and SRF electron photo-injectors

The production of high-current and intense spin polarized electron beams is of great importance in electron-based facilities. Tests are planned to produce such beams in 2023 using GaAs-based photocathodes installed in the Brookhaven National Lab RHIC Coherent electron Cooling superconducting radiofrequency (SRF) photogun [1]. A fast and efficient electron polarimeter operating in the MeV energy range is required to measure the beam spin polarization. While Mott polarimeters provide larger measured asymmetries, a Compton Transmission polarimeter is well suited in the few MeV energy range. In this work, we report on a relatively compact and cost-effective Compton transmission polarimeter which has been built and calibrated at Jefferson Lab (JLab). First, we present the design of the polarimeter radiator, polarized target analyzing magnet, BGO detector assembly and data acquisition system. Next, results of a two-week commissioning study performed at the JLab Upgraded Injector Test Facility will be described. Here, a well-known polarized electron beam produced from a bulk GaAs photocathode in a dc high-voltage photogun was first measured in a 180 keV Mott scattering polarimeter, then used to characterize and calibrate the Compton transmission polarimeter as a function of the polarized target magnetization and beam properties. Finally, we report an effective analyzing power of the Compton polarimeter and compare experimental results with those produced via Geant4 simulations.

Blume, G.↗

Computational simulations and beamline optimizations for an electron beam degrader at CEBAF

An electron beam degrader is under development with the objective of measuring the transverse and longitudinal acceptance of the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. This project is in support of the CE+BAF positron capability. Computational simulations of beam-target interactions and particle tracking were performed integrating the GEANT4 and Elegant toolkits. A solenoid was added to the setup to control the beam's divergence. Parameter optimization of the solenoid field and magnetic quadrupoles gradient was also performed to further reduce particle loss through the rest of the injector beamline.

Lizárraga-Rubio, V.↗

Exploring Causes of Beam Loss at CEBAF

At Jefferson Lab, the Continuous Electron Beam Accelerator (CEBAF) features a unique design with two linear accelerators and two arc sections allowing for multiple turns of the electron beam, as well as four experimental end stations. This topology leads to increased beam losses, especially in the spreader and recombiner regions connecting the arcs to the linacs and in the extraction regions connecting the experimental end stations to the accelerator. These losses result in equipment activation and operational interruptions. Recent upgrades to the facility’s diagnostic systems, including the addition of xenon ion chambers, have provided higher-resolution data regarding these loss events. Building on this improved observational capability, we are developing a simulation framework using optics codes and the Geant4-based BDSIM to model beam extinction and halo formation in these regions. This work aims to correlate simulation results with experimental data to isolate the causes of beam loss and inform future machine tuning strategies. We present a summary of conclusions drawn from recent operational studies and outline a plan to model the beam loss and validate the simulations.

Matthews, C. [Old Dominion Univ., Norfolk, VA (Uni↗

Reduction in radioactivity-induced backgrounds using a novel active veto detector for rare event search experiments

The results of a newly developed annular cryogenic phonon-mediated active veto detector are discussed which shows a significant reduction of radioactivity-induced backgrounds in rare event search experiments. The veto detector is made up of germanium weighing ∼500 g with an outer diameter of 76 mm and an inner diameter of 28 mm. The detector can host a 25 mm diameter germanium inner target detector of mass ∼10 g. A GEANT4 simulation with the active veto and inner target detector shows a gamma background reduction of 50 - 80% which is further improved (> 90%) with 4pi veto coverage. Experimental measurements with the detector assembly agree well with the simulation.

Chaudhuri, Mouli↗

Numerical Study of a Passive Wedge Absorber System for Momentum Selection of Muon Beams

The Muon g-2 experiment aims to measure the anomalous magnetic moment of the muon with higher precision than previous experiments. In order to do this muons are created from protons hitting the target and are then sent to the M4 and M5 lines to be injected into the storage ring. The storage ring only accepts muons with momentum within 0.2% of 3094 MeV/c. In order to decrease the number of lost muons a wedge was placed in the M5 beam line to utilize the properties of ionization cooling to create a more uniform momentum spread. Previous simulations predicted a much larger gain of storable muons than the experimental results showed. In order to determine the cause of this discrepancy, simulations were run using a GEANT4 based code to track muons through the M4 and M5 lines, the inflector, and the storage ring while adjusting the orientation, material, geometrical parameters and studying the performance of this wedge for a wide range of incoming muon energies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Creating a Detector Response Matrix for the Micro-Calorimeter

To better understand the results from the micro calorimeter, a detector response matrix (DRM) was generated. This will allow to predict source responses, which in turn will improve the confidence in the instrument. To generate a DRM, the simulation package Rapid Adaptable Multi-threaded Particle and Radiation Transport Simulation (RAMPART) that utilizes underlying Geant4 libraries for particle transport was used to generate the simulation. A flat energy input spectrum ranging from 0 keV to 3000 keV was used to generate the response. 37 x 10 9 particles were simulated. In this report, the details and findings are presented.

47 OTHER INSTRUMENTATION↗

Improving Fission Products at CARIBU: Near Field Detection (Q3/FY21 Quarterly Progress Report)

The overview of our project as well as most recent results have been presented at the NSARD review in April, and more recently during the WoNDRAM workshop. We have been dealing with recent personnel changes in the group. Miguel Bencomo, who has worked with us on this project as a postdoc at LLNL since 2019, will be terminating his appointment within the next two weeks to take a full-time appointment with Raytheon. We continue training our new team member Dan Hoff to take over data analysis from the last experiment we performed, as well as prepare for upcoming measurements. Additionally, we are working with a summer student, John Wilkinson, who is training to perform GEANT4 simulations of beta detector this summer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Straight Line Geometric Path Lengths – Examples and Distributions

The straight line geometric path distribution of different shapes is a fundamental parameter of any a detector sensitive and in the presence of high energy charged particles such as galactic cosmic rays (GCRs). Knowledge of the straight line path distribution can yield first estimates of the expected energy distribution due to minimum ionizing particles. This predicted shape provides a valuable interpretation tool of spectra of particles that are unlikely to stop in a detector and may present a background or desired signal. These quantities have been calculated many times before including analytically, Coleman (1973), and even in Geant4 software, (Agostinelli, Allison et al. 2003, Santin, Ivanchenko et al. 2005). For this work we utilize the Rapid Adaptable Multi-threaded Particle and Radiation Transport (RAMPART) simulation framework and collect some common shapes all with the same volume to serve as a reference of path lengths and instructions manual for computing other shapes as desired.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improving Fission Products at CARIBU: Near Field Detection (Q4/FY21 Quarterly Progress Report)

Since the last quarterly, we have been working on improving the GEANT4 simulation model, which we currently use for the 4-pi gas counter efficiency calculations, to streamline the work when calculating multi-level decay properties. We have also been preparing for the next branching-ratio measurement, which will be for 161 Tb. Because travel is still limited and restricted, we have worked with a summer student on performing simulations to estimate our detector’s efficiency for different thresholds.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Celeritas: GPU-accelerated particle transport for detector simulation in High Energy Physics experiments

Within the next decade, experimental High Energy Physics (HEP) will enter a new era of scientific discovery through a set of targeted programs recommended by the Particle Physics Project Prioritization Panel (P5), including the upcoming High Luminosity Large Hadron Collider (LHC) HL-LHC upgrade and the Deep Underground Neutrino Experiment (DUNE). These efforts in the Energy and Intensity Frontiers will require an unprecedented amount of computational capacity on many fronts including Monte Carlo (MC) detector simulation. In order to alleviate this impending computational bottleneck, the Celeritas MC particle transport code is designed to leverage the new generation of heterogeneous computer architectures, including the exascale computing power of U.S. Department of Energy (DOE) Leadership Computing Facilities (LCFs), to model targeted HEP detector problems at the full fidelity of Geant4. This paper presents the planned roadmap for Celeritas, including its proposed code architecture, physics capabilities, and strategies for integrating it with existing and future experimental HEP computing workflows.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Compton transmission polarimeter for DC and SRF electron photo-injectors

The production of high-current and intense spin polarized electron beams is of great importance in electron-based facilities. Tests are planned to produce such beams in 2023 using GaAs-based photocathodes installed in the Brookhaven National Lab RHIC Coherent electron Cooling superconducting radiofrequency (SRF) photogun [1]. A fast and efficient electron polarimeter operating in the MeV energy range is required to measure the beam spin polarization. While Mott polarimeters provide larger measured asymmetries, a Compton Transmission polarimeter is well suited in the few MeV energy range. In this work, we report on a relatively compact and cost-effective Compton transmission polarimeter which has been built and calibrated at Jefferson Lab (JLab). First, we present the design of the polarimeter radiator, polarized target analyzing magnet, BGO detector assembly and data acquisition system. Next, results of a two-week commissioning study performed at the JLab Upgraded Injector Test Facility will be described. Here, a well-known polarized electron beam produced from a bulk GaAs photocathode in a dc high-voltage photogun was first measured in a 180 keV Mott scattering polarimeter, then used to characterize and calibrate the Compton transmission polarimeter as a function of the polarized target magnetization and beam properties. Finally, we report an effective analyzing power of the Compton polarimeter and compare experimental results with those produced via Geant4 simulations.

Blume, G.↗

Improving Fission Products at CARIBU: Near Field Detection (Q2/FY24 Quarterly Progress Report)

We continue to make progress in the analysis of 111 Ag decay data to determine gamma-ray intensities with the aim of improving these intensities to below 1% precision. The correctness of detection efficiencies is integral to obtaining accurate and precise results. While Geant4 provides us with efficiencies for detection of a coincidence event of a beta-particle with a 96, 245, or 342 gamma-ray, as outlined in Figure 1, it is important that we validate these results with the efficiencies obtained from the experimental decay data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

CEA/LANL Collaboration Needs [Slides]

The success of the current Gamma Reaction History program is the product of a multi-institutional collaboration between LANL/LLNL/AWE/NNSS/LLE/Industry. Our multi-decadal collaboration has led a multiple generation of reaction history instruments (Generation-1, -2, -3, and now we are designing 4th generation). In post-ignition era, new challenges are arising (too fast, too high, too many). In 4th Generation, we aim to increase Detection Dynamic Range and need Geant4 simulation help.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mu2e experiment: Simulation of the Production Target

The Mu2e experiment will search for coherent, neutrinoless conversion of muons to elections in an aluminum stopping target. A simulation program is used to experiment and design the production target of the Mu2e experiment. The module uses programing languages and libraries to work. The program called the Offline uses C++ as the programing language in the module. To construct the simulation, the Geant4 library constructs shapes and uses them in the simulation program, ROOT. The offline program simplifies the creation of the tube by organizing them into parameter objects and nesting them with other variables required to construct the tube-like center point, material, or if it is allowed to conflict with other solids. The parameter varies for every solid tube. The geometry file uploads the parameters by declaring and organizing the parameters in C++ using the configuration tools. The author describes the development and the future of this project.

43 PARTICLE ACCELERATORS↗

Development of a Fast-Spectrum Self-Powered Neutron Detector for Molten Salt Experiments in the Versatile Test Reactor

Abstract—The self-powered neutron detector (SPND) is a widely used flux monitor in thermal nuclear reactors. Although this is a mature technology, the current state of the art is tuned for a thermal neutron spectrum, so many of the devices currently in use lack sensitivity to fast neutrons. Because current in SPNDs is produced through nuclear reactions with the neutron flux inside a reactor, sensitivity in SPNDs is determined by the neutron cross section of the neutron-sensitive portion of the detector, termed the emitter. This neutron cross section drops by orders of magnitude between thermal and fast neutron energies for many emitters in currently used SPNDs, with a corresponding drop in current from the detector. This paper discusses efforts to develop a fast-spectrum self-powered neutron detector (FS-SPND) that is sensitive to neutrons with energies ranging from 0.025 eV up to 1 MeV. An in-depth analysis of Evaluated Nuclear Data File (ENDF)/B-VII.1 neutron-capture cross sections was performed, and four new materials were identified that are suitable emitter candidates for use in measuring fast neutrons. All four materials are stable mid-shell nuclei in the region between doubly magic 132Sn and 208Pb. Each candidate was simulated with the Geant4 Monte Carlo simulation toolkit to optimize overall detector efficiency.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗