The Odd Dark Matter Halos of Isolated Gas-rich Ultradiffuse Galaxies

Abstract We analyze circular velocity profiles of seven ultradiffuse galaxies (UDGs) that are isolated and gas-rich. Assuming that the dark matter halos of these UDGs have a Navarro–Frenk–White (NFW) density profile or a Read density profile (which allows for constant-density cores), the inferred halo concentrations are systematically lower than the cosmological median, even as low as −0.6 dex (about 5 σ away) in some cases. Alternatively, similar fits can be obtained with a density profile that scales roughly as 1/ r 2 for radii larger than a few kiloparsecs. Both solutions require the radius where the halo circular velocity peaks ( R max ) to be much larger than the median expectation. Surprisingly, we find an overabundance of such large- R max halos in the IllustrisTNG dark-matter-only simulations compared to the Gaussian expectation. These halos form late and have higher spins compared to median halos of similar masses. The inner densities of the most extreme among these late-forming halos are higher than their NFW counterparts, leading to a ∼1/ r 2 density profile. However, the two well-resolved UDGs in our sample strongly prefer lower dark matter densities in the center than the simulated ones. Comparing to IllustrisTNG hydrodynamical simulations, we also find a tension in getting both low enough circular velocities and high enough halo mass to accommodate the measurements. Our results indicate that the gas-rich UDGs present a significant challenge for galaxy formation models.

79 ASTRONOMY AND ASTROPHYSICS↗

Collective Excitations of a Dipolar Bose-Einstein Condensate

We have measured the effect of dipole-dipole interactions on the frequency of a collective mode of a Bose-Einstein condensate. At relatively large numbers of atoms, the experimental measurements are in good agreement with zero temperature theoretical predictions based on the Thomas-Fermi approach. Experimental results obtained for the dipolar shift of a collective mode show a larger dependency to both the trap geometry and the atom number than the ones obtained when measuring the modification of the condensate aspect ratio due to dipolar forces. These findings are in good agreement with simulations based on a Gaussian ansatz.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A new method for point-spread function correction using the ellipticity of re-smeared artificial images in weak gravitational lensing shear analysis

Highly accurate weak lensing analysis is urgently required for planned cosmic shear observations. For this purpose we have eliminated various systematic noises in the measurement. The point-spread function (PSF) effect is one of them. A perturbative approach for correcting the PSF effect on the observed image ellipticities has been previously employed. Here we propose a new non-perturbative approach for PSF correction that avoids the systematic error associated with the perturbative approach. The new method uses an artificial image for measuring shear which has the same ellipticity as the lensed image. This is done by re-smearing the observed galaxy images and observed star images (PSF) with an additional smearing function to obtain the original lensed galaxy images. We tested the new method with simple simulated objects that have Gaussian or Sérsic profiles smeared by a Gaussian PSF with sufficiently large size to neglect pixelization. Under the condition of no pixel noise, it is confirmed that the new method has no systematic error even if the PSF is large and has a high ellipticity.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-J-188: Theoretical Estimation of Margin Necessary for Markerless Motion Tracking

Purpose: To estimate the margin necessary to adequately cover the target using markerless motion tracking (MMT) of lung lesions given the uncertainty in tracking and the size of the target. Methods: Simulations were developed in Matlab to determine the effect of tumor size and tracking uncertainty on the margin necessary to achieve adequate coverage of the target. For simplicity, the lung tumor was approximated by a circle on a 2D radiograph. The tumor was varied in size from a diameter of 0.1 − 30 mm in increments of 0.1 mm. From our previous studies using dual energy markerless motion tracking, we estimated tracking uncertainties in x and y to have a standard deviation of 2 mm. A Gaussian was used to simulate the deviation between the tracked location and true target location. For each size tumor, 100,000 deviations were randomly generated, the margin necessary to achieve at least 95% coverage 95% of the time was recorded. Additional simulations were run for varying uncertainties to demonstrate the effect of the tracking accuracy on the margin size. Results: The simulations showed an inverse relationship between tumor size and margin necessary to achieve 95% coverage 95% of the time using the MMT technique. The margin decreased exponentially with target size. An increase in tracking accuracy expectedly showed a decrease in margin size as well. Conclusion: In our clinic a 5 mm expansion of the internal target volume (ITV) is used to define the planning target volume (PTV). These simulations show that for tracking accuracies in x and y better than 2 mm, the margin required is less than 5 mm. This simple simulation can provide physicians with a guideline estimation for the margin necessary for use of MMT clinically based on the accuracy of their tracking and the size of the tumor.

60 APPLIED LIFE SCIENCES↗

Using a coupled dispersion model to estimate depletion of a tritium oxide plume by a forest

Tritium processing facilities may release tritium oxide (HTO) to the atmosphere which poses potential health risks to exposed co-located workers and to offsite individuals. Most radiological consequence analyses determine HTO dose by applying Gaussian plume models to simulate the transport of HTO. Within these models, deposition velocity is used to assess the sum of all deposition processes acting on the plume. While this may account for vegetative and soil uptake or respiration processes, it may currently lack inclusion of the complex interactions within heterogeneous forested environments. In this complex morphology, dispersion patterns are significantly altered by changing flow regimes above and below the forest canopy and by the transfer of plume material across the canopy boundary. To determine the effects of a heterogeneous forest canopy on an airborne HTO plume, a Gaussian plume model coupled with an advection-diffusion plume model was applied to estimate transport in the free atmosphere above the forest and within the forest canopy and understory. During 2012, wind speed and wind direction measurements taken at 5 heights, ranging from 2-m to 28-m, on an instrumented meteorological tower located in a loblolly pine forest at the Department of Energy (DOE) Savannah River Site (SRS), near Aiken, SC. From these measurements, model predictions were made over a full spectrum of meteorological conditions. Deposition and resuspension velocities were calculated based on the model-predicted flux of plume material across the top of the forest canopy. Additionally, net deposition velocity of the plume material was calculated as the difference between the deposition and resuspension velocities. The 1st and 5th percentile net deposition velocities were estimated to be 0.7 cm s-1 and 1.2 cm s-1, respectively.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Propagation of 0{pi} pulses in a gas of three-level atoms

We have theoretically studied the pulsed regime of electromagnetically induced transparency. In particular, simulations of propagation of Gaussian and 0{pi} copropagating laser pulses in a medium consisting of three-level {Lambda} atoms have been performed. It has been found that even at the two-photon resonance, the length of propagation for the 0{pi} pulses is much smaller than the one for the Gaussian probe pulses. Using the dark and bright basis, we explain this behavior. Some possible applications are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

TESTING TESTS ON ACTIVE GALACTIC NUCLEI MICROVARIABILITY

Literature on optical and infrared microvariability in active galactic nuclei (AGNs) reflects a diversity of statistical tests and strategies to detect tiny variations in the light curves of these sources. Comparison between the results obtained using different methodologies is difficult, and the pros and cons of each statistical method are often badly understood or even ignored. Even worse, improperly tested methodologies are becoming more and more common, and biased results may be misleading with regard to the origin of the AGN microvariability. This paper intends to point future research on AGN microvariability toward the use of powerful and well-tested statistical methodologies, providing a reference for choosing the best strategy to obtain unbiased results. Light curves monitoring has been simulated for quasars and for reference and comparison stars. Changes for the quasar light curves include both Gaussian fluctuations and linear variations. Simulated light curves have been analyzed using {chi}{sup 2} tests, F tests for variances, one-way analyses of variance and C-statistics. Statistical Type I and Type II errors, which indicate the robustness and the power of the tests, have been obtained in each case. One-way analyses of variance and {chi}{sup 2} prove to be powerful and robust estimators for microvariations, while the C-statistic is not a reliable methodology and its use should be avoided.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantile Kriging R Package

A re-implementation of Quantile Kriging. Quantile Kriging was described by Matthew Plumlee & Rui Tuo in their 2014 paper "Building Accurate Emulators for Stochastic Simulations via Quantile Kriging." With computational savings when dealing with replication from the recent paper "Practical heteroskedastic Gaussian process modeling for large simulation experiments”, it is now possible to apply Quantile Kriging to a wider class of problems. In addition to fitting the model, other useful tools are provided such as the ability to automatically perform leave-one-out cross validation.

Quinlan, KevinR.↗

Space charge effects in ultrafast electron diffraction and imaging

Understanding space charge effects is central for the development of high-brightness ultrafast electron diffraction and microscopy techniques for imaging material transformation with atomic scale detail at the fs to ps timescales. We present methods and results for direct ultrafast photoelectron beam characterization employing a shadow projection imaging technique to investigate the generation of ultrafast, non-uniform, intense photoelectron pulses in a dc photo-gun geometry. Combined with N-particle simulations and an analytical Gaussian model, we elucidate three essential space-charge-led features: the pulse lengthening following a power-law scaling, the broadening of the initial energy distribution, and the virtual cathode threshold. The impacts of these space charge effects on the performance of the next generation high-brightness ultrafast electron diffraction and imaging systems are evaluated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Generation of a controllable TNSA deuteron beam using deuterated metal targets

This study investigated the feasibility of using deuterated titanium targets for the generation of a target normal sheath acceleration (TNSA) deuteron beam. Commercial 25-μm-thick titanium foil was cut into 500 x 500-μm 2 squares and subsequently deuterated using different approaches. The spectra and total yields of all emitted ions were measured using a Thomson parabola ion spectrometer. It was found that a 24-h exposure to 1 atm of D 2 gas at 400°C is the most-efficient deuteration method, producing yields in the mid-10 11 deuterons per shot. The deuteron energy spectra changed from an exponential shape at low ion yields to exponentially modified Gaussians at higher yields. Simulations suggest that this effect is due to increased Coulomb interactions between the ions, which suppress the low energies. Separate campaigns will utilize the presented approach to produce a TNSA triton beam. Furthermore, two such targets will be used in a pitcher/catcher configuration to study the tritium–tritium reaction T(t, 2n)α.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TU-F-CAMPUS-J-05: Effect of Uncorrelated Noise Texture On Computed Tomography Quantitative Image Features

Purpose: To investigate the relationship between quantitative image features (i.e. radiomics) and statistical fluctuations (i.e. electronic noise) in clinical Computed Tomography (CT) using the standardized American College of Radiology (ACR) CT accreditation phantom and patient images. Methods: Three levels of uncorrelated Gaussian noise were added to CT images of phantom and patients (20) acquired in static mode and respiratory tracking mode. We calculated the noise-power spectrum (NPS) of the original CT images of the phantom, and of the phantom images with added Gaussian noise with means of 50, 80, and 120 HU. Concurrently, on patient images (original and noise-added images), image features were calculated: 14 shape, 19 intensity (1st order statistics from intensity volume histograms), 18 GLCM features (2nd order statistics from grey level co-occurrence matrices) and 11 RLM features (2nd order statistics from run-length matrices). These features provide the underlying structural information of the images. GLCM (size 128x128) was calculated with a step size of 1 voxel in 13 directions and averaged. RLM feature calculation was performed in 13 directions with grey levels binning into 128 levels. Results: Adding the electronic noise to the images modified the quality of the NPS, shifting the noise from mostly correlated to mostly uncorrelated voxels. The dramatic increase in noise texture did not affect image structure/contours significantly for patient images. However, it did affect the image features and textures significantly as demonstrated by GLCM differences. Conclusion: Image features are sensitive to acquisition factors (simulated by adding uncorrelated Gaussian noise). We speculate that image features will be more difficult to detect in the presence of electronic noise (an uncorrelated noise contributor) or, for that matter, any other highly correlated image noise. This work focuses on the effect of electronic, uncorrelated, noise and future work shall examine the influence of changes in quantum noise on the features. J. Oliver was supported by NSF FGLSAMP BD award HRD #1139850 and the McKnight Doctoral Fellowship.

60 APPLIED LIFE SCIENCES↗

Planck 2013 results. XXV. Searches for cosmic strings and other topological defects

Planck data have been used to provide stringent new constraints on cosmic strings and other defects. We describe forecasts of the CMB power spectrum induced by cosmic strings, calculating these from network models and simulations using line-of-sight Boltzmann solvers. We have studied Nambu-Goto cosmic strings, as well as field theory strings for which radiative effects are important, thus spanning the range of theoretical uncertainty in the underlying strings models. We have added the angular power spectrum from strings to that for a simple adiabatic model, with the extra fraction defined as f 10 at multipole = 10. This parameter has been added to the standard six parameter fit using COSMOMC with flat priors. For the Nambu-Goto string model, we have obtained a constraint on the string tension of G μ/c 2 < 1.5 × 10 -7 and f 10 < 0.015 at 95% confidence that can be improved to G μ/c 2 < 1.3 × 10-7 and f 10 < 0.010 on inclusion of high-&ell; CMB data. For the Abelian-Higgs field theory model we find, G μ AH /c 2 < 3.2 × 10 -7 and f 10 < 0.028. The marginalised likelihoods for f 10 and in the f 10 -Ω b h 2 plane are also presented. We have additionally obtained comparable constraints on f 10 for models with semilocal strings and global textures. In terms of the effective defect energy scale these are somewhat weaker at G μ/c 2 < 1.1 × 10 -6 . We have made complementarity searches for the specific non-Gaussian signatures of cosmic strings, calibrating with all-sky Planck resolution CMB maps generated from networks of post-recombination strings. We have validated our non-Gaussian searches using these simulated maps in a Planck -realistic context, estimating sensitivities of up to Δ G μ/c 2 &approx; 4 × 10 -7 . We have obtained upper limits on the string tension at 95% confidence of G μ/c 2 < 9.0 × 10 -7 with modal bispectrum estimation and G μ/c 2 < 7.8 × 10 -7 for real space searches with Minkowski functionals. These are conservative upper bounds because only post-recombination string contributions have been included in the non-Gaussian analysis.

79 ASTRONOMY AND ASTROPHYSICS↗

Detection Limits of Low-mass, Long-period Exoplanets Using Gaussian Processes Applied to HARPS-N Solar Radial Velocities

Radial velocity (RV) searches for Earth-mass exoplanets in the habitable zone around Sun-like stars are limited by the effects of stellar variability on the host star. In particular, suppression of convective blueshift and brightness inhomogeneities due to photospheric faculae/plage and starspots are the dominant contribution to the variability of such stellar RVs. Gaussian process (GP) regression is a powerful tool for statistically modeling these quasi-periodic variations. We investigate the limits of this technique using 800 days of RVs from the solar telescope on the High Accuracy Radial velocity Planet Searcher for the Northern hemisphere (HARPS-N) spectrograph. These data provide a well-sampled time series of stellar RV variations. Into this data set, we inject Keplerian signals with periods between 100 and 500 days and amplitudes between 0.6 and 2.4 m s{sup −1}. We use GP regression to fit the resulting RVs and determine the statistical significance of recovered periods and amplitudes. We then generate synthetic RVs with the same covariance properties as the solar data to determine a lower bound on the observational baseline necessary to detect low-mass planets in Venus-like orbits around a Sun-like star. Our simulations show that discovering planets with a larger mass (∼0.5 m s{sup −1}) using current-generation spectrographs and GP regression will require more than 12 yr of densely sampled RV observations. Furthermore, even with a perfect model of stellar variability, discovering a true exo-Venus (∼0.1 m s{sup −1}) with current instruments would take over 15 yr. Therefore, next-generation spectrographs and better models of stellar variability are required for detection of such planets.

47 OTHER INSTRUMENTATION↗

The Atacama Cosmology Telescope: DR6 power spectrum foreground model and validation

We discuss the model of astrophysical emission at millimeter wavelengths used to characterize foregrounds in the multi-frequency power spectra of the Atacama Cosmology Telescope (ACT) Data Release 6 (DR6), expanding on Louis et al. (2025) (2503.14452). We detail several tests to validate the capability of the DR6 parametric foreground model to describe current observations and complex simulations, and show that cosmological parameter constraints are robust against model extensions and variations. We demonstrate consistency of the model with pre-DR6 ACT data and observations from Planck and the South Pole Telescope. We evaluate the implications of using different foreground templates and extending the model with new components and/or free parameters. In all scenarios, the DR6 ΛCDM and ΛCDM+N eff cosmological parameters shift by less than 0.5σ relative to the baseline constraints. Some foreground parameters shift more; we estimate their systematic uncertainties associated with modeling choices. From our constraint on the kinematic Sunyaev-Zel'dovich power, we obtain a conservative limit on the duration of reionization of Δz rei < 4.4, assuming a reionization midpoint consistent with optical depth measurements and a minimal low-redshift contribution, with varying assumptions for this component leading to tighter limits. Finally, we analyze realistic non-Gaussian, correlated microwave sky simulations containing Galactic and extragalactic foreground fields, built independently of the DR6 parametric foreground model. Processing these simulations through the DR6 power spectrum and likelihood pipeline, we recover the input cosmological parameters of the underlying cosmic microwave background field, a new demonstration for small-scale CMB analysis. These tests validate the robustness of the ACT DR6 foreground model and cosmological parameter constraints.

CMBR experiments↗

An emulator for the Lyman-α forest in beyond-ΛCDM cosmologies

Interpreting observations of the Lyman-α forest flux power spectrum requires interpolation between a small number of expensive simulations. We present a Gaussian process emulator modelling the 1D flux power spectrum as a function of the amplitude and slope of the small-scale linear matter power spectrum, and the state of the intergalactic medium at the epoch of interest (2 < z < 4). This parameterisation enables the prediction of the flux power spectrum in extended cosmological models that are not explicitly included in the training set, eliminating the need to construct bespoke emulators for a number of extensions to ΛCDM. Our emulator is appropriate for cosmologies in which the linear matter power spectrum is described to percent level accuracy by just an amplitude and slope across the epoch of interest, and in the regime probed by eBOSS/DESI data. We demonstrate this for massive neutrino cosmologies, where the emulator is able to predict the flux power spectrum in a Σm ν = 0.3 eV neutrino cosmology to sub-percent accuracy, without including massive neutrinos in the training simulations. Further parameters would be required to describe models with sharp features in the linear power, such as warm or light axion dark matter. This work will facilitate the combination of upcoming DESI data with observations of the cosmic microwave background, to obtain constraints on neutrino mass and other extensions to ΛCDM cosmology.

79 ASTRONOMY AND ASTROPHYSICS↗

EXPRES. II. Searching for Planets around Active Stars: A Case Study of HD 101501

By controlling instrumental errors to below 10 cm s{sup −1}, the EXtreme PREcision Spectrograph (EXPRES) allows for a more insightful study of photospheric velocities that can mask weak Keplerian signals. Gaussian processes (GP) have become a standard tool for modeling correlated noise in radial velocity data sets. While GPs are constrained and motivated by physical properties of the star, in some cases they are still flexible enough to absorb unresolved Keplerian signals. We apply GP regression to EXPRES radial velocity measurements of the 3.5 Gyr old chromospherically active Sun-like star, HD 101501. We obtain tight constraints on the stellar rotation period and the evolution of spot distributions using 28 seasons of ground-based photometry, as well as recent Transiting Exoplanet Survey Satellite data. Light-curve inversion was carried out on both photometry data sets to reveal the spot distribution and spot evolution timescales on the star. We find that the >5 m s{sup −1} rms radial velocity variations in HD 101501 are well modeled with a GP stellar activity model without planets, yielding a residual rms scatter of 45 cm s{sup −1}. We carry out simulations, injecting and recovering signals with the GP framework, to demonstrate that high-cadence observations are required to use GPs most efficiently to detect low-mass planets around active stars like HD 101501. Sparse sampling prevents GPs from learning the correlated noise structure and can allow it to absorb prospective Keplerian signals. We quantify the moderate to high-cadence monitoring that provides the necessary information to disentangle photospheric features using GPs and to detect planets around active stars.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact of SPECT corrections on 3D-dosimetry for liver transarterial radioembolization using the patient relative calibration methodology

Purpose: Many centers aim to plan liver transarterial radioembolization (TARE) with dosimetry, even without CT-based attenuation correction (AC), or with unoptimized scatter correction (SC) methods. This work investigates the impact of presence vs absence of such corrections, and limited spatial resolution, on 3D dosimetry for TARE. Methods: Three voxelized phantoms were derived from CT images of real patients with different body sizes. Simulations of {sup 99m}Tc-SPECT projections were performed with the SIMIND code, assuming three activity distributions in the liver: uniform, inside a “liver’s segment,” or distributing multiple uptaking nodules (“nonuniform liver”), with a tumoral liver/healthy parenchyma ratio of 5:1. Projection data were reconstructed by a commercial workstation, with OSEM protocol not specifically optimized for dosimetry (spatial resolution of 12.6 mm), with/without SC (optimized, or with parameters predefined by the manufacturer; dual energy window), and with/without AC. Activity in voxels was calculated by a relative calibration, assuming identical microspheres and {sup 99m}Tc-SPECT counts spatial distribution. 3D dose distributions were calculated by convolution with {sup 90}Y voxel S-values, assuming permanent trapping of microspheres. Cumulative dose-volume histograms in lesions and healthy parenchyma from different reconstructions were compared with those obtained from the reference biodistribution (the “gold standard,” GS), assessing differences for D95%, D70%, and D50% (i.e., minimum value of the absorbed dose to a percentage of the irradiated volume). γ tool analysis with tolerance of 3%/13 mm was used to evaluate the agreement between GS and simulated cases. The influence of deep-breathing was studied, blurring the reference biodistributions with a 3D anisotropic gaussian kernel, and performing the simulations once again. Results: Differences of the dosimetric indicators were noticeable in some cases, always negative for lesions and distributed around zero for parenchyma. Application of AC and SC reduced systematically the differences for lesions by 5%–14% for a liver segment, and by 7%–12% for a nonuniform liver. For parenchyma, the data trend was less clear, but the overall range of variability passed from −10%/40% for a liver segment, and −10%/20% for a nonuniform liver, to −13%/6% in both cases. Applying AC, SC with preset parameters gave similar results to optimized SC, as confirmed by γ tool analysis. Moreover, γ analysis confirmed that solely AC and SC are not sufficient to obtain accurate 3D dose distribution. With breathing, the accuracy worsened severely for all dosimetric indicators, above all for lesions: with AC and optimized SC, −38%/−13% in liver’s segment, −61%/−40% in the nonuniform liver. For parenchyma, D50% resulted always less sensitive to breathing and sub-optimal correction methods (difference overall range: −7%/13%). Conclusions: Reconstruction protocol optimization, AC, SC, PVE and respiratory motion corrections should be implemented to obtain the best possible dosimetric accuracy. On the other side, thanks to the relative calibration, D50% inaccuracy for the healthy parenchyma from absence of AC was less than expected, while the optimization of SC was scarcely influent. The relative calibration therefore allows to perform TARE planning, basing on D50% for the healthy parenchyma, even without AC or with suboptimal corrections, rather than rely on nondosimetric methods.

60 APPLIED LIFE SCIENCES↗

Dosimetric Impact of Surgical Clips in Electron Beam Treatment of Breast Cancer

Titanium clips are commonly used to delineate the location of the tumor bed during breast cancer surgery. Electron beams are frequently used to boost radiation dose to the breast cavity. This research investigated the effect on such boost treatments as a result of metallic clip perturbation potentially exhibited through attenuation and scatter processes using measurements with Gafchromic film and treatment planning simulation with both generalized Gaussian pencil beam and electron Monte Carlo algorithms. Results showed that the potential effect of clip interference is unidentifiable from both algorithms. Dosimetry with Gafchromic external beam therapy film did detect dose perturbations caused by the titanium clips in proximal plane, 0.23 mm away, resulting in 3.0% backscatter and 2.4% attenuation at 6 MeV and 2.0% backscatter and 6.7% attenuation at 9 MeV. The noise contribution of the film scanner is estimated to be about 0.4% and nearly 2% uncertainty in film calibration. As a result, we conclude that the magnitude of dose perturbations from clip is negligible for clinical findings.

61 RADIATION PROTECTION AND DOSIMETRY↗