Search NASA⌕ Search

SEARCH · Search NASA

Results for “Graphic User Interface (GUI)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

GAM/GAMV GUI

The GAM/GAMV GUI provides a graphic user interface to public domain FORTRAN codes (gam, version 2.0 and gamv, version 2.0) that were developed at Stanford University in 1998 (see Deutsch and Journel, 1998). The gam and gamv codes allow for calculation of different measures of spatial variability and spatial correction from a set of available data. The GAM/GAMV GUI accesses the executable versions of the gam and gamv software, initiates the calculations by the executables and manages the outputs of the executables in a user friendly graphical manner. Additionally, the GAM/GAMV GUI code then provides the user with both automatic and interactive tools in a graphical interface to fit models to the calculations of the spatial variation/correlation of the data. The GAM/GAMV GUI software allows the user to get various parameters for the gam and gamv executables that do the actual calculations by using dialog boxes, it provides some error checking as these parameters are set and then allows the user to run the calculation by calling the executable compiled from the previously developed FORTRAN software. The resulting output of the gam or gamv codes can be visualized in the GAM/GAMV GUI interface. The visualization portion of GAM/GAMV allows for both automatic and manual fitting of the model of spatial variation/correlation. GAM/GAMV GUI can be run in batch mode from the command line without invoking the graphical interface.

McKenna, Sean↗

KT3D GUI

The KT3D GUI provides a graphic user interface to a public domain FORTRAN code (kt3d) that was developed at Stanford University in 1998 (see Deutsch and Journel, 1998). The kt3d software contains the implementation of several kriging algorithms that complete spatial estimation onto a grid or a set of points from a set of available data and using a variogram model to describe the spatial variation of the data. The variogram model is calculated and modeled using the GAM/GAMV GUI software described separately. The KT3D GUI software allows the user to set various parameters for the FORTRAN code by using dialog boxes, it provides some error checking as these parameters are set and then allows the user to run the calculation by calling the executable compiled from the previously developed FORTRAN software. The resulting output of the kt3d code can be visualized in the KT3D GUI in several ways. If a gridded estimation problem is selected, color maps of the estimated values and the kriging variance are displayed in side by side images. If either jackknifing or cross-validation options are selected, then a series of user-defined X-Y plots can be created.

McKenna, Sean↗

The QUIC Start Guide (V.6.4.9)

QUIC stands for the Quick Urban & Industrial Complex (QUIC) dispersion modeling system. QUIC is a fast response urban dispersion model that runs on a laptop. QUIC is comprised of a 3D wind field model called QUIC-URB, a transport and dispersion model called QUIC-PLUME, and graphical user interface called QUIC-GUI. QUIC also includes QUIC-PRESSURE to solve for pressure fields in and around buildings, a population exposure assessment tool called QUIC-POP, and an indoor infiltration calculator for computing indoor concentrations. Transport and dispersion for different types of airborne contaminants can be computed on building to neighborhood scales in tens of seconds to tens of minutes. QUIC will never give perfect answers, but it will account for the effects of buildings in an approximate way and provide more realism than non-building aware dispersion models.

97 MATHEMATICS AND COMPUTING↗

SolVap_StarTer (Solvent Evaporation Graphical User Interface) [SWR-26-029]

SolVap_StarTer is an open-source solvent evaporation GUI. The software combines previously published (peer-reviewed scientific journals) evaporation and crystallization physics into an easy-to-use graphical interface. The software will allow the user to specify a coating composition and drying environment, and then predict the evolution of the film as it dries. Potential applications include tracking the change in multi-solvent composition and solute concentration in solution-processed perovskites films, predicting the point of crystallization, and calculating equivalent processing parameters for transferring a process between different coating and drying methods. Github repo: https://github.com/NatLabRockies/SolVap Streamlit app: https://solvap.streamlit.app/

Starger, Jesse [National Laboratory of the Rockies↗

SU-D-9A-03: STAMP: Simulator for Texture Analysis in MRI/PET

Purpose: To develop a convenient simulation platform to facilitate PET/MR image analysis with the prospect of gaining a better understanding of the influence of acquisition parameters on PET/MRI textural features. The simulation platform is demonstrated by showing textural variations of a representative case study using different image acquisition parameters. Methods: The simulation platform is composed of MRI simulators JEMRIS and SIMRI to achieve simulations of customized MRI sequences on sample tumor models. The PET simulator GATE is used to get 2D and 3D Monte Carlo acquisitions of voxelized PET sources using a phantom geometry and a customized scanner architecture. The platform incorporates a series of graphical user interfaces written in Matlab. Two GUIs are used to facilitate communication with the simulation executables installed on a computer cluster. A third GUI is used to collect and display the clinical and simulated images, as well as fused PET/MRI images, and perform computation of textural features.To illustrate the capabilities of this platform, one FDG-PET and T1-weighted (T1w) digitized tumor models were generated from clinical images of a soft-tissue sarcoma patient. Numerically simulated MR images were produced using 3 different echo times (TE) and 5 different repetition times (TR). PET 2D images were simulated using an OSEM algorithm with 1 to 32 iterations and a post-reconstruction Gaussian filter of 0, 2, 4 or 6 mm width. Results: STAMP was successfully used to produce numerically simulated FDG-PET and MRI images, and to calculate their corresponding textures. Three typical textures (GLCM-Contrast, GLSZM-ZSV and NGTDM-Coarseness) were found to vary by a range of 45% on average compared to reference scanning conditions in the case of FDG-PET, and by a range of 40% in the case of T1w MRI. Conclusion: We have successfully developed a Matlab-based simulation platform to facilitate PET/MRI texture image analysis for outcome prediction.

60 APPLIED LIFE SCIENCES↗

SU-E-T-595: Design of a Graphical User Interface for An In-House Monte Carlo Based Treatment Planning System: Planning and Contouring Tools

Purpose: An in-house Monte Carlo based treatment planning system (MC TPS) has been developed for modulated electron radiation therapy (MERT). Our preliminary MERT planning experience called for a more user friendly graphical user interface. The current work aimed to design graphical windows and tools to facilitate the contouring and planning process. Methods: Our In-house GUI MC TPS is built on a set of EGS4 user codes namely MCPLAN and MCBEAM in addition to an in-house optimization code, which was named as MCOPTIM. Patient virtual phantom is constructed using the tomographic images in DICOM format exported from clinical treatment planning systems (TPS). Treatment target volumes and critical structures were usually contoured on clinical TPS and then sent as a structure set file. In our GUI program we developed a visualization tool to allow the planner to visualize the DICOM images and delineate the various structures. We implemented an option in our code for automatic contouring of the patient body and lungs. We also created an interface window displaying a three dimensional representation of the target and also showing a graphical representation of the treatment beams. Results: The new GUI features helped streamline the planning process. The implemented contouring option eliminated the need for performing this step on clinical TPS. The auto detection option for contouring the outer patient body and lungs was tested on patient CTs and it was shown to be accurate as compared to that of clinical TPS. The three dimensional representation of the target and the beams allows better selection of the gantry, collimator and couch angles. Conclusion: An in-house GUI program has been developed for more efficient MERT planning. The application of aiding tools implemented in the program is time saving and gives better control of the planning process.

60 APPLIED LIFE SCIENCES↗

Prony Ringdown GUI (CERTS Prony Ringdown, part of the DSI Tool Box)

The PNNL Prony Ringdown graphical user interface is one analysis tool included in the Dynamic System Identification toolbox (DSI Toolbox). The Dynamic System Identification toolbox is a MATLAB-based collection of tools for parsing and analyzing phasor measurement unit data, especially in regards to small signal stability. It includes tools to read the data, preprocess it, and perform small signal analysis. 5. Method of Solution: The Dynamic System Identification Toolbox (DSI Toolbox) is designed to provide a research environment for examining phasor measurement unit data and performing small signal stability analysis. The software uses a series of text-driven menus to help guide users and organize the toolbox features. Methods for reading in populate phasor measurement unit data are provided, with appropriate preprocessing options for small-signal-stability analysis. The toolbox includes the Prony Ringdown GUI and basic algorithms to estimate information on oscillatory modes of the system, such as modal frequency and damping ratio.

Tuffner, Francis↗

A graphical user interface platform to support power electronic converters and integrated systems

Power Electronic Systems have grown in size and complexity over the past years. Therefore, users require interfaces to properly configure, develop, and deploy these systems. This work presents a Graphical User Interface that dynamically adapts to the system and allows the user to control and monitor its operation. This GUI uses networked communication and open-source Python libraries to allow the user to interact with the system at its different hierarchical layers, as well as visualize the interconnection of the full system. This is demonstrated by showing the user interface applied to a megawatt class charging station that consists of various energy resources.

Dean, Ben↗

CHARMM-GUI Bicelle Builder : An Extension of Membrane Builder for Modeling and Simulation of Bicelle Systems

Membrane mimetics, such as detergent micelles, nanodiscs, and amphipol complexes, which can provide membrane-like environments while retaining small and soluble features, have been utilized to study membrane proteins. A bicelle, composed of varying lipids and detergents, is a useful membrane mimetic because the lipid-to-detergent ratio, the q-value, can be adjusted to alter the properties of the aggregate, including the thickness and size of the bicelle. However, building a bicelle model for modeling and simulation studies requires nontrivial efforts, even for experts. We introduce CHARMM-GUI Bicelle Builder, a web-based platform that can generate various all-atom bicelle systems via a graphical user interface with all available lipids and detergents in Membrane Builder. To illustrate and validate Bicelle Builder with practical systems, we have modeled and simulated pure bicelles consisting of 1,2-dimyristoyl-sn-glycero-3-phosphocholine (DMPC) lipids with 1,2-dihexanoyl-sn-glycero-3-phosphocholine (C6DHPC) detergents and protein–bicelle complexes, composed of DMPC with C6DHPC, foscholine-10 (FOS10), and lysophosphatidylcholine-12 (LPC12) detergents. Our simulation results indicate that Bicelle Builder can generate reliable and robust bicelle models with and without proteins that retain DMPC bilayer characteristics. Bicelle Builder is expected to help researchers better understand not only bicelles themselves but also atomistic-level structures of protein–bicelle complexes that are often difficult to access through experimental approaches.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

EMPaSE: an Extensible Multi-Paradigm Simulation Environment

EMPaSE is a hierarchical, extensible, modular modeling environment for developing and running hybrid simulations of sequential-modular, systems dynamics, discrete-event, and agent-based paradigms. It contains two principle components: a multi-paradigm simulation engine and a graphical user interface. EMPaSE models are defined through a hierarchically-defined set of computational modules that define the simulation logic. Inter-module communication occurs through two complimentary systems: pull-based "ports" for general computation patterns and push-based "plugs" for event processing. Entities (i.e. agents) within the simulation operate within an abstract multi-network environment. The EMPaSE simulation engine is designed around a flexible plug-in architecture, allowing simulations to import computational modules, engine customizations, and interfaces to external applications from independent plug-in libraries. The EMPaSE GUI environment provides an environment for graphically constructing, executing, and debugging EMPaSE models. As with the simulation engine, the GUI is constructed on top of an extensible architecture that supports rapid customization of the user experience through external plug-in libraries.

Siirola, John↗

A Low Cost SIPM Evaluation and Control Prototyping System including accurate bias voltage generation, leakage current measurement, and temperature control using Peltier cooling

We describe an electronics system to operate SIPMs in the laboratory. The system is comprised of a single channel amplifier board (SIPM Amp) and a 4-channel control board to which up to 4 SIPM Amp boards can be connected. The control board supplies a common low voltage power for the amplifiers. All channels feature individually regulated bias and Peltier power voltages, along withPt10K RTD readout. A graphical user interface allows control of the bias voltages, amplifier voltage, Peltier voltages, and also provides for readback of leakage currents and other voltages. The GUI app has a feedback loop to measure the SIPM temperature (with the PT10K) and generate correction voltages to the Peltier to regulate the temperature. The temperatures, which can be achieved by Peltier cooling depend on the thermal design of the setup, the practical limit being about 50C below ambient. The SIPM Amp. board is a small (3x5cm) PCB that has a single SIPM readout channel. The SIPM scan be surface mounted on the pcb or connected to a 2-pin 0.100" socket. The area around the SIPM footprint is thermally isolated by perforations in the PCB. The RTD is located inside the thermal break. Onboard is BV and LV filtering. The 10X amplifier is based on MiniCircuits' GALI-S66+ integrated circuit, tweaked for a 6V power. The amplifier was selected for a combination of high bandwidth, low noise, and low power. An accoupled amplifier output is connected to an SMA connector. For best operation of this inverting amplifier the output signal should be in the range of 0 to -1V.The Amplifier board is connected to the Control board with a 10-conductor 0.025" pitch ribbon cable, carrying all the services. Peltier power for currents more than 1A should use a separate 2-contact connector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Developing a GUI for the Robotic Test Stand

The introduction of this poster explains the technology behind DUNE’s far and near detectors and how passing neutrinos generate electrons that drift into a wire grid. I then explain how 3 ASICs manage signals received from electron interception. Next, the poster states how COLDATA chips are undergoing quality control by a Robotic Test Stand using a state machine. I further explained how earlier tests were done via a command line script and the necessity to implement a user-friendly Graphical User Interface with new features a command line can’t implement. For the implementation section, tools and methods for implementation are listed such as Python, tkinter, and GitHub as well as how multithreading and queue implementation was necessary for GUI functionality. Then, I elaborated on the GUIs new features. Finally, I explain how the GUI will be distributed across multiple institutions and future changes planned for the GUI. Photos of the RTS, far detector cave, diagram of anode assembly plane, COLDATA chips, set up tab, result tab, and legacy command line interface are shown.

Gutierrez Villanueva, Jaziel [DuPage Coll.]↗

MicroCT: X-Ray Radiograph Quality Assurance Through the Analysis of Copper Strip Data Using the Matlab CuStrip Analysis GUI

This Standard Operating Procedure (SOP) supplements the LEDP data acquisition SOPand reference material and specimen analysis SOP, and provides the specific procedural steps for analyzing copper strip (CuStrip) data using the Matlab CuStrip Analysis Graphical User Interface and preparing the tables and graphs to be used in the reporting of analytical results as required by the LEDP Quality Assurance Plan for MicroCT Scanning]. This procedure applies only to the analysis of two-slit data.

42 ENGINEERING↗

Planning tools for modulated electron radiotherapy

Purpose: To develop tools to plan modulated electron radiotherapy (MERT) and to compare the MERT plans to conventional or intensity modulated radiotherapy (IMRT) treatment plans. Methods: Monte Carlo dose calculations of electron fields shaped with the inherent photon multileaf collimators (MLCs) were investigated in this study. Treatment plans for four postmastectomy breast cancer patients were generated using MERT. The distances from the patient skin surfaces to the distal planning target volume surfaces were computed along the beam axis direction to determine the physical depth. Electron beam energies were selected to provide target coverage at these depths and energy bins were generated. A custom built MERT treatment planning graphical user interface (MERTgui) was used to shape the electron bins into deliverable electron segments. Monte Carlo dose distribution simulations were performed using the MLC-defined segments generated from the MERTgui. A custom built superposition gui was used to combine doses for each segment using relative weights and final MERT treatment plans were compared to the conventional or IMRT treatment plans. In addition, a demonstration of combined MERT and IMRT treatment plans was performed. Results: The MERT treatment plans provided acceptable target organ coverage in all cases. Relative to 3D conventional or IMRT treatment plans, the MERT plans predicted lower heart doses in all cases; average of the heart D{sub 20} of all plans was reduced from 14.1 to 3.3 Gy. The contralateral breast and contralateral lung doses decreased substantially with MERT planning compared to IMRT (on average, contralateral breast heart D{sub 20} was reduced from 8.7 to 0.7 Gy and contralateral lung D{sub 20} was reduced from 8.4 to 1.2 Gy with MERT). Ipsilateral lung D{sub 20} was lower with MERT than with the conventional plans (44.6 vs 29.2 Gy with MERT), but greater when compared against IMRT treatment plans (25.4 vs 28.9 Gy with MERT). A MERT and IMRT combination plan was generated to benefit from the complementary advantages of MERT and IMRT, resulting in satisfactory target coverage and reduced organ at risk doses. Conclusions: MERT tools can facilitate treatment planning and provide plans for treatment of shallow targets such as the postmastectomy chest wall.

61 RADIATION PROTECTION AND DOSIMETRY↗

Advanced Code for Photocathode Design

The Phase I activity demonstrated that PhotoQE could be upgraded and modified to allow input using a graphical user interface. Specific calls to platform-dependent (e.g. IMSL) function calls were removed, and Fortran77 components were rewritten for Fortran95 compliance. The subroutines, specifically the common block structures and shared data parameters, were reworked to allow the GUI to update material parameter data, and the system was targeted for desktop personal computer operation. The new structures overcomes the previous rigid and unmodifiable library structures by implementing new, materials library data sets and repositioning the library values to external files. Material data may originate from published literature or experimental measurements. Further optimization and restructuring would allow custom and specific emission models for beam codes that rely on parameterized photoemission algorithms. These would be based on simplified and parametric representations updated and extended from previous versions (e.g., Modified Fowler-Dubridge, Modified Three-Step, etc.).

43 PARTICLE ACCELERATORS↗