Search NASA⌕ Search

SEARCH · Search NASA

Results for “Grid Logging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

High Performance Network Monitoring [Slides]

Network Monitoring requires a substantial use of data and error analysis to overcome issues with clusters. Zenoss and Splunk help to monitor system log messages that are reporting issues about the clusters to monitoring services. Infiniband infrastructure on a number of clusters upgraded to ibmon2. ibmon2 requires different filters to report errors to system administrators. Focus for this summer is to: (1) Implement ibmon2 filters on monitoring boxes to report system errors to system administrators using Zenoss and Splunk; (2) Modify and improve scripts for monitoring and administrative usage; (3) Learn more about networks including services and maintenance for high performance computing systems; and (4) Gain a life experience working with professionals under real world situations. Filters were created to account for clusters running ibmon2 v1.0.0-1 10 Filters currently implemented for ibmon2 using Python. Filters look for threshold of port counters. Over certain counts, filters report errors to on-call system administrators and modifies grid to show local host with issue.

97 MATHEMATICS AND COMPUTING↗

Effects of Granular Control on Customers’ Perspective and Behavior with Automated Demand Response Systems

Automated demand response (Auto-DR) is expected to close the loop between buildings and the grid by providing machine-to-machine communications to curtail loads without the need for human intervention. Hence, it can offer more reliable and repeatable demand response results to the grid than the manual approach and make demand response participation a hassle-free experience for customers. However, many building operators misunderstand Auto-DR and are afraid of losing control over their building operation. To ease the transition from manual to Auto-DR, we designed and implemented granular control of Auto-DR systems so that building operators could modify or opt out of individual load-shed strategies whenever they wanted. This paper reports the research findings from this effort demonstrated through a field study in large commercial buildings located in New York City. We focused on (1) understanding how providing granular control affects building operators’ perspective on Auto-DR, and (2) evaluating the usefulness of granular control by examining their interaction with the Auto-DR user interface during test events. Through trend log analysis, interviews, and surveys, we found that: (1) the opt-out capability during Auto-DR events can remove the feeling of being forced into load curtailments and increase their willingness to adopt Auto-DR; (2) being able to modify individual load-shed strategies allows flexible Auto-DR participation that meets the building’s changing operational requirements; (3) a clear display of automation strategies helps building operators easily identify how Auto-DR is functioning and can build trust in Auto-DR systems.

Schetrit, Oren↗

Scalable multilevel Monte Carlo methods exploiting parallel redistribution on coarse levels

Here, we study an element agglomeration coarsening strategy that requires data redistribution at coarse levels when the number of coarse elements becomes smaller than the number of MPI processes used on the finest level. The overall procedure generates coarse elements (general unstructured unions of fine grid elements) within the framework of element-based algebraic multigrid methods (or AMGe) studied previously. The AMGe-generated coarse spaces have the ability to exhibit approximation properties of the same order as the fine-level spaces since by construction they contain the piecewise polynomials of the same order as on the fine level. These approximation properties are key for the successful use of AMGe in multilevel solvers for nonlinear partial differential equations as well as for multilevel Monte Carlo (MLMC) simulations. The ability to coarsen without being constrained by the number of MPI processes, as described in the present paper, allows to improve the scalability of these solvers as well as the overall MLMC method. The paper illustrates this latter fact with detailed scalability study of MLMC simulations applied to model Darcy equations with a stochastic log-normal permeability field.

AMGe↗

Direct Numerical Simulation of Incompressible Pipe Flow Using a B-Spline Spectral Method

A numerical method based on b-spline polynomials was developed to study incompressible flows in cylindrical geometries. A b-spline method has the advantages of possessing spectral accuracy and the flexibility of standard finite element methods. Using this method it was possible to ensure regularity of the solution near the origin, i.e. smoothness and boundedness. Because b-splines have compact support, it is also possible to remove b-splines near the center to alleviate the constraint placed on the time step by an overly fine grid. Using the natural periodicity in the azimuthal direction and approximating the streamwise direction as periodic, so-called time evolving flow, greatly reduced the cost and complexity of the computations. A direct numerical simulation of pipe flow was carried out using the method described above at a Reynolds number of 5600 based on diameter and bulk velocity. General knowledge of pipe flow and the availability of experimental measurements make pipe flow the ideal test case with which to validate the numerical method. Results indicated that high flatness levels of the radial component of velocity in the near wall region are physical; regions of high radial velocity were detected and appear to be related to high speed streaks in the boundary layer. Budgets of Reynolds stress transport equations showed close similarity with those of channel flow. However contrary to channel flow, the log layer of pipe flow is not homogeneous for the present Reynolds number. A topological method based on a classification of the invariants of the velocity gradient tensor was used. Plotting iso-surfaces of the discriminant of the invariants proved to be a good method for identifying vortical eddies in the flow field.

Loulou, Patrick↗

Hybrid Reynolds-Averaged/Large Eddy Simulation of a Cavity Flameholder; Assessment of Modeling Sensitivities

Steady-state and scale-resolving simulations have been performed for flow in and around a model scramjet combustor flameholder. The cases simulated corresponded to those used to examine this flowfield experimentally using particle image velocimetry. A variety of turbulence models were used for the steady-state Reynolds-averaged simulations which included both linear and non-linear eddy viscosity models. The scale-resolving simulations used a hybrid Reynolds-averaged / large eddy simulation strategy that is designed to be a large eddy simulation everywhere except in the inner portion (log layer and below) of the boundary layer. Hence, this formulation can be regarded as a wall-modeled large eddy simulation. This effort was undertaken to formally assess the performance of the hybrid Reynolds-averaged / large eddy simulation modeling approach in a flowfield of interest to the scramjet research community. The numerical errors were quantified for both the steady-state and scale-resolving simulations prior to making any claims of predictive accuracy relative to the measurements. The steady-state Reynolds-averaged results showed a high degree of variability when comparing the predictions obtained from each turbulence model, with the non-linear eddy viscosity model (an explicit algebraic stress model) providing the most accurate prediction of the measured values. The hybrid Reynolds-averaged/large eddy simulation results were carefully scrutinized to ensure that even the coarsest grid had an acceptable level of resolution for large eddy simulation, and that the time-averaged statistics were acceptably accurate. The autocorrelation and its Fourier transform were the primary tools used for this assessment. The statistics extracted from the hybrid simulation strategy proved to be more accurate than the Reynolds-averaged results obtained using the linear eddy viscosity models. However, there was no predictive improvement noted over the results obtained from the explicit Reynolds stress model. Fortunately, the numerical error assessment at most of the axial stations used to compare with measurements clearly indicated that the scale-resolving simulations were improving (i.e. approaching the measured values) as the grid was refined. Hence, unlike a Reynolds-averaged simulation, the hybrid approach provides a mechanism to the end-user for reducing model-form errors.

Baurle, R. A.↗

EXTRAGALACTIC CHEMICAL ABUNDANCES: DO H II REGIONS AND YOUNG STARS TELL THE SAME STORY? THE CASE OF THE SPIRAL GALAXY NGC 300

We have obtained new spectrophotometric data for 28 H II regions in the spiral galaxy NGC 300, a member of the nearby Sculptor Group. The detection of several auroral lines, including [O III] {lambda}4363, [S III] {lambda}6312, and [N II] {lambda}5755, has allowed us to measure electron temperatures and direct chemical abundances for the whole sample. We determine for the first time in this galaxy a radial gas-phase oxygen abundance gradient based solely on auroral lines, and obtain the following least-square solution: 12 + log(O/H) = 8.57({+-}0.02) - 0.41({+-}0.03)R/R {sub 25}, where the galactocentric distance is expressed in terms of the isophotal radius R {sub 25}. The characteristic oxygen abundance, measured at 0.4 x R{sub 25}, is 12 + log(O/H) = 8.41. The gradient corresponds to -0.077 {+-} 0.006 dex kpc{sup -1}, and agrees very well with the galactocentric trend in metallicity obtained for 29 B and A supergiants in the same galaxy, -0.081 {+-} 0.011 dex kpc{sup -1}. The intercept of the regression for the nebular data virtually coincides with the intercept obtained from the stellar data, which is 8.59({+-}0.05). This allows little room for depletion of nebular oxygen onto dust grains, although in this kind of comparison we are somewhat limited by systematic uncertainties, such as those related to the atomic parameters used to derive the chemical compositions. We discuss the implications of our result with regard to strong-line abundance indicators commonly used to estimate the chemical compositions of star-forming galaxies, such as R {sub 23}. By applying a few popular calibrations of these indices based on grids of photoionization models on the NGC 300 H II region fluxes, we find metallicities that are higher by 0.3 dex (a factor of 2) or more relative to our nebular (T{sub e} based) and stellar ones. We detect Wolf-Rayet stellar emission features in {approx}1/3 of our H II region spectra, and find that in one of the nebulae hosting these hot stars the ionizing field has a particularly hard spectrum, as gauged by the 'softness' parameter {eta} = (O{sup +}/O{sup ++})/(S{sup +}/S{sup ++}). We suggest that this is related to the presence of an early WN star. By considering a larger sample of extragalactic H II regions we confirm, using direct abundance measurements, previous findings of a metallicity dependence of {eta}, in the sense that softer stellar continua are found at high metallicity.

99 GENERAL AND MISCELLANEOUS↗

Geocellular model of St. Peter Sandstone for University of Illinois at Urbana-Champaign DDU Feasibility Study

The geocellular model of the St. Peter Sandstone was constructed for the University of Illinois at Urbana-Champaign DDU feasibility study. Starting with the initial area of review (18.0 km by 18.1 km [11.2 miles by 11.3 miles]) the boundaries of the model were trimmed down to 9.7 km by 9.7 km (6 miles by 6 miles) to ensure that the model enclosed a large enough volume so that the cones of depression of both the production and injection wells would not interact with each other, while at the same time minimizing the number of cells to model to reduce computational time. The grid-cell size was set to 61.0 m by 61.0 m (200 feet by 200 feet) for 160 nodes in the X and Y directions. The top surface of the St. Peter Sandstone was provided by geologists working on the project, and the average thickness of the formation was taken from the geologic prospectus they provided. An average thickness of 68.6 m (225 feet) was used for the St. Peter Sandstone, resulting in 45 layers for the model. Petrophysical data was taken from available rotary sidewall core data (Morrow et al., 2017). As geothermal properties (thermal conductivity, specific heat capacity) are closely related to mineralogy, specifically the percentage of quartz, available mineralogical data was assembled and used with published data of geothermal values to determine these properties (Waples and Waples, 2004; Robertson, 1988). The St. Peter Sandstone was divided into facies according to similar geothermal and petrophysical properties, and distributed according to available geophysical log data and prevailing interpretations of the depositional/diagenetic history (Will et al. 2014). Petrophysical and geothermal properties were distributed through geostatistical means according to the associated distributions for each lithofacies. The formation temperature was calculated, based on data from continuous temperature geophysical log from a deep well drilled into the Precambrian basement at the nearby Illinois Basin Decatur Project (IBDP) where CO2 is currently being sequestered (Schlumberger, 2012). Salinity values used in the model were taken from regional studies of brine chemistry in the St. Peter Sandstone, including for the IBDP (e.g., Panno et al. 2018). After being reviewed by the project's geologists, the model was then passed onto the geological engineers to begin simulations of the geothermal reservoir and wellbores.

15 GEOTHERMAL ENERGY↗

Restoration of the Potosi Dynamic Model 2010

In topical Report DOE/FE0002068-1 [2] technical performance evaluations on the Cambrian Potosi Formation were performed through reservoir modeling. The data included formation tops from mud logs, well logs from the VW1 and the CCS1 wells, structural and stratigraphic formation from three dimensional (3D) seismic data, and field data from several waste water injection wells for Potosi Formation. Intention was for two million tons per annum (MTPA) of CO2 to be injected for 20 years. In this Task the 2010 Potosi heterogeneous model (referred to as the "Potosi Dynamic Model 2010" in this report) was re-run using a new injection scenario; 3.2 MTPA for 30 years. The extent of the Potosi Dynamic Model 2010, however, appeared too small for the new injection target. It was not sufficiently large enough to accommodate the evolution of the plume. Also, it might have overestimated the injection capacity by enhancing too much the pressure relief due to the relatively close proximity between the injector and the infinite acting boundaries. The new model, Potosi Dynamic Model 2013a, was built by extending the Potosi Dynamic Model 2010 grid to 30 miles x 30 miles (48 km by 48 km), while preserving all property modeling workflows and layering. This model was retained as the base case. Potosi Dynamic Model 2013.a gives an average CO2 injection rate of 1.4 MTPA and cumulative injection of 43 Mt in 30 years, which corresponds to 45% of the injection target. This implies that according to this preliminary model, a minimum of three (3) wells could be required to achieve the injection target. The injectivity evaluation of the Potosi formation will be revisited in topical Report 15 during which more data will be integrated in the modeling exercise. A vertical flow performance evaluation could be considered for the succeeding task to determine the appropriate tubing size, the required injection tubing head pressure (THP) and to investigate whether the corresponding well injection rate falls within the tubing erosional velocity limit. After 30 years, the plume extends 15 miles (24 km) in E-W and 14 miles (22 km) in N-S directions. After injection is completed, the plume continues to migrate laterally, mainly driven by the remaining pressure gradient. After 100 years post-injection, the plume extends 17 miles (27 km) in E-W and 15 miles (24 km) in N-S directions. The increase of reservoir pressure at the end of injection is approximately 370 psia around the injector and gradually decreases away from the well. The reservoir pressure increase is less than 30 psia beyond 14 miles (22 km) away from injector. The initial reservoir pressure is restored after approximately 20 years post-injection. This result, however, is associated with uncertainties on the boundary conditions, and a sensitivity analysis could be considered for the succeeding tasks. It is important to remember that the respective plume extent and areal pressure increase corresponds to an injection of 43 Mt CO2. Should the targeted cumulative injection of 96 Mt be achieved; a much larger plume extent and areal pressure increase could be expected. Re-evaluating the permeability modeling, vugs and heterogeneity distributions, and relative permeability input could be considered for the succeeding Potosi formation evaluations. A simulation using several injectors could also be considered to determine the required number of wells to achieve the injection target while taking into account the pressure interference.

Adushita, Yasmin↗

Combinatorial Evaluation of Physical Feature Engineering, Classical Machine Learning, and Deep Learning Models for Synchrophasor Data at Scale

A major objective of the project was to train and evaluate the effectiveness of multiple event and anomaly detection, identification and classification deep temporal learning models for processing of real-time phasor measurement unit (PMU) data streams. A vast dataset, consisting of two years of phasor measurements from all three U.S. Interconnections, was curated and released by the Department of Energy (DOE) through Pacific Northwest National Laboratory (PNNL). The dataset also included an event log that provided event times and types (e.g. generator trips, line trips, planned service events, transformer operations, etc.). Our analysis of this dataset addressed six (6) of the eleven (11) research priorities identified in Funding Opportunity Announcement (FOA) DE-FOA-0001861 “Big Data Analysis of Synchrophasor Data” (FOA 1861). Rather than being limited to pre-determined specific algorithms, this project relied on the uniquely structured, highly performant underlying time series database capabilities of the PredictiveGrid platform to assess the vast dataset utilizing a wide variety of algorithms.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Upscaling permeability for three-dimensional fractured porous rocks with the multiple boundary method

Upscaling permeability of grid blocks is crucial for groundwater models. A novel upscaling method for three-dimensional fractured porous rocks is presented. The objective of the study was to compare this method with the commonly used Oda upscaling method and the volume averaging method. First, the multiple boundary method and its computational framework were defined for three-dimensional stochastic fracture networks. Then, the different upscaling methods were compared for a set of rotated fractures, for tortuous fractures, and for two discrete fracture networks. The results computed by the multiple boundary method are comparable with those of the other two methods and fit best the analytical solution for a set of rotated fractures. The errors in flow rate of the equivalent fracture model decrease when using the multiple boundary method. Furthermore, the errors of the equivalent fracture models increase from well-connected fracture networks to poorly connected ones. Finally, the diagonal components of the equivalent permeability tensors tend to follow a normal or log-normal distribution for the well-connected fracture network model with infinite fracture size. By contrast, they exhibit a power-law distribution for the poorly connected fracture network with multiple scale fractures. The study demonstrates the accuracy and the flexibility of the multiple boundary upscaling concept. This makes it attractive for being incorporated into any existing flow-based upscaling procedures, which helps in reducing the uncertainty of groundwater models.

58 GEOSCIENCES↗

Isochrones for old (>5 Gyr) stars and stellar populations. I. Models for –2.4 ≤ [Fe/H] ≤+0.6, 0.25 ≤ Y ≤ 0.33, and –0.4 ≤ [α/Fe] ≤+0.4

Canonical grids of stellar evolutionary sequences have been computed for the helium mass-fraction abundances Y = 0.25, 0.29, and 0.33, and for iron abundances that vary from –2.4 to +0.4 (in 0.2 dex increments) when [α/Fe] =+0.4, or for the ranges –2.0 ≤ [Fe/H] ≤+0.6, –1.8 ≤ [Fe/H] ≤+0.6 when [α/Fe] =0.0 and –0.4, respectively. The grids, which consist of tracks for masses from 0.12 M{sub ⊙} to 1.1-1.5 M{sub ⊙} (depending on the metallicity) are based on up-to-date physics, including the gravitational settling of helium (but not metals diffusion). Interpolation software is provided to generate isochrones for arbitrary ages between ≈5 and 15 Gyr and any values of Y, [α/Fe], and [Fe/H] within the aformentioned ranges. Comparisons of isochrones with published color-magnitude diagrams (CMDs) for the open clusters M67 ([Fe/H] ≈0.0) and NGC 6791 ([Fe/H] ≈0.3) and for four of the metal-poor globular clusters (47 Tuc, M3, M5, and M92) indicate that the models for the observed metallicities do a reasonably good job of reproducing the locations and slopes of the cluster main sequences and giant branches. The same conclusion is reached from a consideration of plots of nearby subdwarfs that have accurate Hipparcos parallaxes and metallicities in the range –2.0 ≲ [Fe/H] ≲ –1.0 on various CMDs and on the (log T {sub eff}, M{sub V} ) diagram. A relatively hot temperature scale similar to that derived in recent calibrations of the infrared flux method is favored by both the isochrones and the adopted color transformations, which are based on the latest MARCS model atmospheres.

79 ASTRONOMY AND ASTROPHYSICS↗

Probing the puncture for black hole simulations

With the puncture method for black hole simulations, the second infinity of a wormhole geometry is compactified to a single 'puncture point' on the computational grid. The region surrounding the puncture quickly evolves to a trumpet geometry. The computational grid covers only a portion of the trumpet throat. It ends at a boundary whose location depends on resolution. This raises the possibility that perturbations in the trumpet geometry could propagate down the trumpet throat, reflect from the puncture boundary, and return to the black hole exterior with a resolution-dependent time delay. Such pathological behavior is not observed. This is explained by the observation that some perturbative modes propagate in the conformal geometry, others propagate in the physical geometry. The puncture boundary exists only in the physical geometry. The modes that propagate in the physical geometry are always directed away from the computational domain at the puncture boundary. The finite difference stencils ensure that these modes are advected through the boundary with no coupling to the modes that propagate in the conformal geometry. These results are supported by numerical experiments with a code that evolves spherically symmetric gravitational fields with standard Cartesian finite difference stencils. The code uses the Baumgarte-Shapiro-Shibata-Nakamura formulation of Einstein's equations with 1+log slicing and gamma-driver shift conditions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Geocellular Model of Mt. Simon Sandstone for University of Illinois at Urbana-Champaign DDU feasibility study

The geocellular model of the Mt. Simon Sandstone was constructed for the University of Illinois at Urbana-Champaign DDU feasibility study. Starting with the initial area of review (18.0 km by 18.1 km [11.2 miles by 11.3 miles]) the boundaries of the model were trimmed down to 9.7 km by 9.7 km (6 miles by 6 miles) to ensure that the model enclosed a large enough volume so that the cones of depression of both the production and injection wells would not interact with each other, while at the same time minimizing the number of cells to model to reduce computational time. The grid-cell size was set to 61.0 m by 61.0 m (200 feet by 200 feet) for 160 nodes in the X and Y directions. Within the model, 67 layers are represented that are parameterized with their sediment/rock properties and petrophysical data. The top surface of the Mt. Simon Sandstone was provided by geologists working on the project, and the average thickness of the formation was taken from the geologic prospectus they provided. An average thickness of 762 m (2500 feet) was used for the Mt. Simon Sandstone, resulting in 60 layers for the model. Petrophysical data was taken from available rotary sidewall core data (Morrow et al., 2017). As geothermal properties (thermal conductivity, specific heat capacity) are closely related to mineralogy, specifically the percentage of quartz, available mineralogical data was assembled and used with published data of geothermal values to determine these properties (Waples and Waples, 2004; Robertson, 1988). The Mt. Simon Sandstone was divided into three separate units (lower, middle, upper) according to similar geothermal and petrophysical properties, and distributed according to available geophysical log data and prevailing interpretations of the depositional/diagenetic history (Freiburg et al. 2016). Petrophysical and geothermal properties were distributed through geostatistical means according to the associated distributions for each lithofacies. The formation temperature was calculated, based on data from continuous temperature geophysical log from a deep well drilled into the Precambrian basement at the nearby Illinois Basin Decatur Project (IBDP) where CO2 is currently being sequestered (Schlumberger, 2012). Salinity values used in the model were taken from regional studies of brine chemistry in the Mt. Simon Sandstone, including for the IBDP (e.g., Panno et al. 2018). After being reviewed by the project's geologists, the model was then passed onto the geological engineers to begin simulations of the geothermal reservoir and wellbores.

15 GEOTHERMAL ENERGY↗

THE MASS-LOSS RETURN FROM EVOLVED STARS TO THE LARGE MAGELLANIC CLOUD. VI. LUMINOSITIES AND MASS-LOSS RATES ON POPULATION SCALES

We present results from the first application of the Grid of Red Supergiant and Asymptotic Giant Branch ModelS (GRAMS) model grid to the entire evolved stellar population of the Large Magellanic Cloud (LMC). GRAMS is a pre-computed grid of 80,843 radiative transfer models of evolved stars and circumstellar dust shells composed of either silicate or carbonaceous dust. We fit GRAMS models to {approx}30,000 asymptotic giant branch (AGB) and red supergiant (RSG) stars in the LMC, using 12 bands of photometry from the optical to the mid-infrared. Our published data set consists of thousands of evolved stars with individually determined evolutionary parameters such as luminosity and mass-loss rate. The GRAMS grid has a greater than 80% accuracy rate discriminating between oxygen- and carbon-rich chemistry. The global dust injection rate to the interstellar medium (ISM) of the LMC from RSGs and AGB stars is on the order of 2.1 Multiplication-Sign 10{sup -5} M{sub Sun} yr{sup -1}, equivalent to a total mass injection rate (including the gas) into the ISM of {approx}6 Multiplication-Sign 10{sup -3} M{sub Sun} yr{sup -1}. Carbon stars inject two and a half times as much dust into the ISM as do O-rich AGB stars, but the same amount of mass. We determine a bolometric correction factor for C-rich AGB stars in the K{sub s} band as a function of J - K{sub s} color, BC{sub K{sub s}}= -0.40(J-K{sub s}){sup 2} + 1.83(J-K{sub s}) + 1.29. We determine several IR color proxies for the dust mass-loss rate (M-dot{sub d}) from C-rich AGB stars, such as log M-dot{sub d} = (-18.90/((K{sub s}-[8.0])+3.37) - 5.93. We find that a larger fraction of AGB stars exhibiting the 'long-secondary period' phenomenon are more O-rich than stars dominated by radial pulsations, and AGB stars without detectable mass loss do not appear on either the first-overtone or fundamental-mode pulsation sequences.

79 ASTRONOMY AND ASTROPHYSICS↗

New model atmospheres for very cool white dwarfs with mixed H/He and pure He compositions

New model atmosphere calculations for very cool white dwarfs with mixed H/He and pure He compositions are presented. The hydrogen-rich models incorporate improved cross section calculations of the collision-induced absorption by molecular hydrogen due to collisions with H2, H, and He. The effects associated with variations in the effective temperature (T(sub eff) greater than or equal to 4000 and less than or equal to 10,000 K), the surface gravity (log g greater than or equal to 7.5 and less than or equal to 9.5), and the chemical composition (N(He)/N(H) greater than or equal to O and less than or equal to 100) are investigated. Results from earlier calculations are confirmed qualitatively, but a more detailed comparison reveals large quantitative deviations. Cool white dwarfs with mixed H/He chemical compositions are shown to be easily recognizable from their predicted strong infrared flux deficiency. Pure helium model calculations are described as well. These include a modified version of the recently developed equation of state of D. Saumon and G. Chabrier. Nonideal effects brought about by various equations of state are explored in detail. For the purpose of this analysis, a model of pressure ionization based on an accurate description of the interactions in a mostly atomic helium fluid is developed. The effects of pressure ionization are shown to be the most important issue in the model calculations. A critical discussion of previous generations of pure helium model calculations is presented. Finally, broadband color indices are provided for the complete model grid.

Bergeron, P.↗

Ordovician-Cambrian Units: Hierarchical Evaluation of Geologic Carbon Storage Resource Estimates

The Indiana Geological and Water Survey (IGWS) led subtask 1.1 to assess the regional distribution and estimate the storage capacity of Ordovician-Cambrian stratigraphic units located within the partnership region. A comprehensive data set of wireline logs and petrophysical information was used to generate these interpretations. These data include core analysis for porosity and permeability, mercury injection capillary pressure (MICP), and existing well data including location and stratigraphic information. This report includes storage resource estimates (SREs) for three potential storage reservoirs(limestone and dolostone from the Upper Ordovician Trenton Limestone/Black River Group and equivalent units, the Middle Ordovician St. Peter Sandstone, and primary target reservoir rocks of the Lower Ordovician and Upper Cambrian Knox Supergroup and equivalent units) calculated using six methodologies: (1) a fixed value of porosity of 10 percent in all units evaluated; (2) a unique average porosity (per well) from wireline-derived porosity (neutron, sonic, and/or density porosity for each unit); (3) porosity values from core analysis; (4) a depth-dependent porosity model (Knox Supergroup only); (5) porosity based on a model based on petrophysical facies; and (6) SREs using National Energy Technology Laboratory’s CO2 Storage prospeCtive Resource Estimation Excel aNalysis (CO2-SCREEN beta V2). All methods used the same values for thickness for each unit. However, the areal extent of each assessment was limited by the data available for each method. Estimated volumes were calculated in 1-by-1 kilometer grid cells and summarized as county and total stratigraphic unit volumes. The resultant SREs mass are displayed using boxplots, which allow for comparing data statistics (mean values and variability) between methods. Differences observed in SRE results from the six methods are mainly attributable to differences in the data and conceptual models used to interpret or estimate porosity in each method. Based on this systematic variability between methods, it is inferred that methods 1, 4, and 6 are best used for regional-scale reconnaissance estimates of storage capacity while methods 2, 3, and 5 are more appropriate for local scales where more data is required. All estimates are data-density dependent and different methods require different amounts of data for reasonable assessments. ArcMap 10.5.1 software was used to portray SREs to help visualize spatial variance of estimates for each methodology, and more importantly, to highlight those areas having the greatest total storage potential estimates.

01 COAL, LIGNITE, AND PEAT↗

Restoration Hydro: A Watershed Approach to Standard Modular New Hydropower

The objectives of FOA DE- FOA-0001836- “Standard Modular Hydropower” included designing a standardized, modular, and environmentally compatible hydropower schematic for implementation in greenfield sites that generate up to 10 MW of capacity. Utilizing funds competitively awarded under DOE’s Water Power Technologies Office, the Natel Energy team developed a concept for modular new stream reach (NSR) hydropower that incorporates multi species upstream and downstream fish passage, improved river channel connectivity, and recreational modules. The in-stream design of the collective modules minimized site specific design and maximized the opportunities for modularity. Financial data was also presented using actual costs from regional suppliers, with figures provided in 2022 dollars. While the project team did not address potential permitting process improvements, the site selection criteria did consider established barriers to hydropower development such as tribal and preserved lands, interconnection proximity, and endangered species to exclude or deprioritize. The project’s design schematic met the objectives of the FOA, and presented a unique solution that targets alluvial pockets as natural features for sustainable development. Natel’s concept also incorporated the company's fish-safe Restoration Hydro Turbine for safe downstream passage, while featuring a rock arch that integrates fish passage, water, recreation, and grade control modules (including sediment). Alignment with the Department of Energy Office of Energy Efficiency and Renewable Energy (EERE) “Innovative Design Concepts for Standard Modular Hydropower and Pumped-Storage Hydropower” Program: According to the Hydropower Vision (DOE, 2016), approximately 16 GW of hydropower growth is possible with the development of technology solutions that balance efficiency, economics, and environmental sustainability. The desired outcome of the SMH program is transformational innovation specifically in the site identification, conceptual, and detailed design phases of technology development lifecycles (DOE, 2018). In developing the SMH design schematic, the team aimed to address the opportunities outlined in the Vision through an inverted design philosophy; rather than singularly prioritizing efficiency and power production, the team focused on integrating hydropower with restoration of degraded streams to optimal ecosystem function and provision of exceptional recreation value as design criteria. To achieve this, Restoration Hydro incorporates the principles of nature-based engineering (WWAP, 2018) and biomimicry (Biomimicry NL.) to strategically deploy complementary combinations of permanent, semi-permanent, and ephemeral low-head structures - such as natural and engineered log jams - that harness geomorphological and hydrological processes at the landscape-scale. Primary applications of Restoration Hydro include: 1) restoration of degraded watersheds’ natural ecological function and enhancement of hydrological connectivity; and 2) creation of associated co-benefits to hydro production, including increased groundwater recharge, improved sediment transport and management, improved water security and water quality. Restoration Hydro projects build upon proven watershed restoration engineering techniques by integrating hydropower turbines into low-head structures using innovative and evolving civil works concepts that facilitate fish and sediment passage, and in some cases create additional revenue-generating recreational opportunities. Powering low-head structures creates a directly monetizable layer of economic value in the form of flexible, reliable, renewable energy on top of the already high-value water, environmental and recreational benefits of watershed and river restoration. The approach aims to create a virtuous, self-reinforcing cycle whereby Restoration Hydro projects support the scaling of ecosystem restoration activities, creating a water-energy-carbon multiplier effect that, through the principles of adaptive change management: 1) improves the resilience of landscapes and downstream population centers for changing hydrological cycles; 2) creates a reliable energy resource that facilitates the integration of intermittent renewable power sources into grids; and 3) supports climate change mitigation through grid decarbonization and enhanced ecosystem carbon capture and retention.

13 HYDRO ENERGY↗

PHYSICAL PROPERTIES OF COMPLEX C HALO CLOUDS

Observations from the Galactic Arecibo L-band Feed Array H I (GALFA-H I) Survey of the tail of Complex C are presented and the halo clouds associated with this complex are cataloged. The properties of the Complex C clouds are compared to clouds cataloged at the tail of the Magellanic Stream to provide insight into the origin and destruction mechanism of Complex C. Magellanic Stream and Complex C clouds show similarities in their mass distributions (slope = -0.7 and -0.6 log (N( log (mass)))/ log (mass), respectively) and have a common line width of 20-30 km s{sup -1} (indicative of a warm component), which may indicate a common origin and/or physical process breaking down the clouds. The clouds cataloged at the tail of Complex C extend over a mass range of 10{sup 1.1}-10{sup 4.8} M{sub sun}, sizes of 10{sup 1.2}-10{sup 2.6} pc, and have a median volume density and pressure of 0.065 cm{sup -3} and (P/k) = 580 K cm{sup -3}. We do not see a prominent two-phase structure in Complex C, possibly due to its low metallicity and inefficient cooling compared to other halo clouds. Assuming that the Complex C clouds are in pressure equilibrium with a hot halo medium, we find a median halo density of 5.8 x 10{sup -4} cm{sup -3}, which given a constant distance of 10 kpc is at a z-height of {approx}3 kpc. Using the same argument for the Stream results in a median halo density of 8.4 x 10-{sup 5} (60 kpc/d) cm{sup -3}. These densities are consistent with previous observational constraints and cosmological simulations. We also assess the derived cloud and halo properties with three-dimensional grid simulations of halo H I clouds and find that the temperature is generally consistent within a factor of 1.5 and the volume densities, pressures, and halo densities are consistent within a factor of three.

79 ASTRONOMY AND ASTROPHYSICS↗