Search NASA⌕ Search

SEARCH · Search NASA

Results for “HEAVY IONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

In situ microstructural evolution in face-centered and body-centered cubic complex concentrated solid-solution alloys under heavy ion irradiation

This study characterizes the microstructural evolution of single-phase complex concentrated solid-solution alloy (CSA) compositions under heavy ion irradiation with the goal of evaluating mechanisms for CSA radiation tolerance in advanced fission systems. Three such alloys, Cr 18 Fe 27 Mn 27 Ni 28 , Cr 15 Fe 35 Mn 15 Ni 35 , and equimolar NbTaTiV, along with reference materials (pure Ni and E90 for the Cr-FeMnNi family and pure V for NbTaTiV) were irradiated at 50 K and 773 K with 1 MeV Kr ++ ions to various levels of displacements per atom (dpa) using in-situ transmission electron microscopy. Cryogenic irradiation resulted in small defect clusters and faulted dislocation loops as large as 12 nm in face-centered cubic (FCC) CSAs. With thermal diffusion suppressed at cryogenic temperatures, defect densities were lower in all CSAs than in their less compositionally complex reference materials indicating that point defect production is reduced during the displacement cascade stage. High temperature irradiation of the two FCC CSA resulted in the formation of interstitial dislocation loops which by 2 dpa grew to an average size of 27 nm in Cr 18 Fe 27 Mn 27 Ni 28 and 10 nm in Cr 15 Fe 35 Mn 15 Ni 35 . This difference in loop growth kinetics was attributed to the difference in Mn-content due to its effect on the nucleation rate by increasing vacancy mobility or reducing the stacking-fault energy.

36 MATERIALS SCIENCE↗

CHICOX, a heavy-ion detection system for GRETA

The CHICOX detection system is an array of position sensitive parallel plate avalanche counters used for heavy ion detection in in-beam particle-gamma coincidence experiments. CHICOX, an upgrade of the CHICO2 array, is geometrically compatible with the GRETINA and GRETA gamma-ray arrays and provides an angular resolution sufficient to utilize the excellent position resolution of GRETINA/GRETA. CHICOX was successfully commissioned and fielded as an auxiliary detector to GRETINA in a campaign of stable-beam Coulomb excitation experiments at the ATLAS facility of Argonne National Laboratory. We report here on the design and in-beam performance of the CHICOX array.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Conceptual design of a heavy ion beam probe diagnostic for the Wendelstein 7-X Stellarator

This article describes the current state of the design of the heavy ion beam probe (HIBP) for Wendelstein 7-X (W7-X). It will be the first HIBP diagnostic on an optimized stellarator and is designed to study electric fields and ion scale turbulence in all W7-X reference magnetic configurations. The use of an existing 2 MV accelerator, located outside of the torus hall, results in the need for a circuitous primary beamline. This increases the complexity of the ion optics design to deliver a focused beam to the plasma. To access most of the magnetic configuration space of W7-X, the secondary beamline and an energy analyzer are designed to pivot, thereby redirecting a wider range of secondary beam trajectories. Signal level estimates indicate that the equilibrium potential can be measured at all radii and that the radial coverage for potential and density fluctuations measurements depends on the plasma density.

47 OTHER INSTRUMENTATION↗

First Measurement of the Neutron-Emission Probability with a Surrogate Reaction in Inverse Kinematics at a Heavy-Ion Storage Ring

Neutron-induced reaction cross sections of short-lived nuclei are imperative to understand the origin of heavy elements in stellar nucleosynthesis and for societal applications, but their measurement is extremely complicated due to the radioactivity of the targets involved. One way of overcoming this issue is to combine surrogate reactions with the unique possibilities offered by heavy-ion storage rings. In this work, we describe the first surrogate-reaction experiment in inverse kinematics, which we successfully conducted at the Experimental Storage Ring (ESR) of the GSI/FAIR facility, using the 208 Pb⁢(p,p') reaction as a surrogate for neutron capture on 207 Pb. Thanks to the outstanding detection efficiencies possible at the ESR, we were able to measure for the first time the neutron-emission probability as a function of the excitation energy of 208 Pb. We have used this probability to select different descriptions of the γ -ray strength function and nuclear level density, and provide reliable results for the neutron-induced radiative capture cross section of 207 Pb at energies for which no experimental data exist.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dynamic modeling for heavy-ion collisions

Recent theory progress in (3+1)D dynamical descriptions of relativistic nuclear collisions at finite baryon density are reviewed. Heavy-ion collisions at different collision energies produce strongly coupled nuclear matter to probe the phase structure of Quantum Chromodynamics (QCD). Dynamical frameworks serve as a quantitative tool to study properties of hot QCD matter and map collisions to the QCD phase diagram. Outstanding challenges are highlighted when confronting theoretical models with the current and forthcoming experimental measurements from the RHIC beam energy scan program.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-rate heavy-ion tracking using MWPCs and PPACs with an Anti-Discharge Unit

This work reports on the development of two robust, heavy-ion beam tracking concepts operating at low pressure (< 15 Torr) for high rate applications (> 200 kHz). The first concept consists of a Multi-Wire Proportional Counter (MWPC) with a central anode consisting of 12 μm Au-plated Tungsten wires spaced 1 mm from each other. The anode grid is sandwiched between two segmented cathodes aligned orthogonally in the two dimensions for (x,y) particle localization. The second detector is a Parallel-Plate Avalanche Counter (PPAC) that uses the same readout geometry as the MWPC, but replaces the wire anode with a 150 nm silver layer deposited on both sides of a thin (< 1 mg/cm 2 ) polypropylene foil. Additionally, the bias circuitry for the PPAC anode central foil is equipped with an Anti-Discharge Unit (ADU) to prevent transitions from proportional operation to streamer formation, thereby avoiding damaging discharges. The localization capability of both detectors was tested with a low-rate alpha-particle source (241-Am). A position resolution of < 1 mm (FWHM) was achieved under stable, high-gas-gain (> 1000) operating conditions. Their performance in terms of detection efficiency as a function of the isotope charge (Z) was determined by irradiating the detectors with a cocktail beam (Z ≤ 15) with energy of ∼ 100 MeV/u. Full detection efficiency is maintained for all available fragments under optimal operational conditions (i.e., voltage bias). Full detection efficiency was achieved at rates above 200 kHz by irradiating the detectors with a 1 cm diameter 238 U beam at an energy of 143 MeV/u.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Issues with the search for critical point in QCD with relativistic heavy ion collisions

A systematic search for a critical point in the phase diagram of QCD matter is under way at the Relativistic Heavy Ion Collider (RHIC) and is planned at several future facilities. Its existence, if confirmed, and its location will greatly enhance our understanding of QCD. In this article, we emphasize several important issues that are often not fully recognized in theoretical interpretations of experimental results relevant to the critical point search. Further, we discuss ways in which our understanding on these issues can be improved.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Bayesian Optimization of The Relativistic Heavy Ion Collider Luminosity via s * Control

A state-of-the-art jet detector named sPHENIX was proposed, commissioned, and operated at the Rel ativistic Heavy Ion Collider (RHIC) from 2023 to 2025. This detector featured precision tracking and calorime try that enable high-statistics studies of the Quark Gluon Plasma through jet modification, upsilon suppres sion, and open heavy flavor production. The innermost component of the three sPHENIX tracking systems is the Monolithic-Active-Pixel-Sensor-based Vertex Detec tor (MVTX) (Fig. 1), which has an acceptance within | s | < 0.1m of the interaction point (IP).

43 PARTICLE ACCELERATORS↗

Evidence of medium response to hard probes using correlations of Z bosons with hadrons in heavy ion collisions

The first measurement of pseudorapidity and azimuthal angle distributions relative to the momentum vector of a Z boson for low transverse momentum ($p_\mathrm{T}$) charged hadrons in lead-lead (PbPb) collisions is presented. By studying the hadrons produced in an event with a high-$p_\mathrm{T}$ Z boson (40 $\lt$ $p_\mathrm{T}$ $\lt$ 350 GeV), the analysis probes how the quark-gluon plasma (QGP) medium created in these collisions affects the parton recoiling opposite to the Z boson. Utilizing PbPb data at a nucleon-nucleon center-of-mass energy $\sqrt{s_{_\mathrm{NN}}}$ = 5.02 TeV from 2018 with an integrated luminosity of 1.67 nb$^{-1}$ and proton-proton (pp) data at the same energy from 2017 with 301 pb$^{-1}$, the distributions are examined in bins of charged-hadron $p_\mathrm{T}$. A significant modification of the distributions for charged hadrons in the range 1 $\lt$ $p_\mathrm{T}$ $\lt$ 2 GeV in PbPb collisions is observed when compared to reference measurements from pp collisions. The data provide new information about the correlation between hard and soft particles in heavy ion collisions, which can be used to test predictions of various jet quenching models. The results are consistent with expectations of a hydrodynamic wake created when the QGP is depleted of energy by the parton propagating through it. Based on comparisons of PbPb data with pp references and predictions from theoretical models, this Letter presents the first evidence of medium-recoil and medium-hole effects caused by a hard probe.

CMS↗

Experimental investigation of abnormal transverse flow enhancement of α particles in heavy-ion collisions

The mass dependence of the transverse flow for Z = 1–5 fragments from the collisions of 40 Ar + 27 Al, 40 Ar + 48 Ti, and 40 Ar + 58 Ni at 47 MeV/nucleon is investigated experimentally in this article. The transverse flow values are determined using the in-plane components of the fragment transverse momenta, where three conventional methods, i.e., the kinetic flow tensor method, the transverse momentum analysis method, and the azimuthal correlation method, are applied to reconstruct the reaction plane in an event-by-event basis. It is demonstrated from the comparison of the present experimental mass dependent flow measurements and the model simulations using an improved antisymmetrized molecular dynamics model that the experimentally observed abnormal α transverse flow enhancement is closely related to the reaction plane reconstruction procedure in the flow extraction. We further investigate the physical existence of the abnormal α flow behavior using a two-particle azimuthal correlation method, which allows us to provide the relative flow magnitude information with an identification of fragment charge number without the knowledge of the reaction plane differing from the three conventional methods. It is found that the relative flow magnitudes deduced from the two-particle azimuthal correlation functions with an identification of Z, with the correction for the recoil effect imposed by the momentum conservation, show a monotonically increasing trend as a function of fragment charge number, with no exception of the α flow enhancement. These results, in addition to those from the improved antisymmetrized molecular dynamics model simulations, definitely provide experimental evidences for the inexistence of the abnormal α flow behavior in the heavy-ion collisions at the present incident energy region in nature.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Correlations between flow and transverse momentum in Xe + Xe and Pb + Pb collisions at the LHC with the ATLAS detector: A probe of the heavy-ion initial state and nuclear deformation

The correlations between flow harmonics v n for n = 2, 3, and 4 and mean transverse momentum [p T ] in 129 Xe + 129 Xe and 208 Pb + 208 Pb collisions at $\sqrt{s}$ = 5.44 and 5.02 TeV, respectively, are measured using charged particles with the ATLAS detector. The correlations are potentially sensitive to the shape and size of the initial geometry, nuclear deformation, and initial momentum anisotropy. The effects from nonflow and centrality fluctuations are minimized, respectively, via a subevent cumulant method and an event-activity selection based on particle production at very forward rapidity. The v n -[p T ] correlations show strong dependencies on centrality, harmonic number n, p T , and pseudorapidity range. Current models qualitatively describe the overall centralityand system-dependent trends but fail to quantitatively reproduce all features of the data. In central collisions, where models generally show good agreement, the v 2 -[p T ] correlations are sensitive to the triaxiality of the quadruple deformation. Comparison of the model with the Pb + Pb and Xe + Xe data confirms that the 129 Xe nucleus is a highly deformed triaxial ellipsoid that has neither a prolate nor oblate shape. This provides strong evidence for a triaxial deformation of the 129 Xe nucleus from high-energy heavy-ion collisions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

$$\Lambda $$ polarization in very high energy heavy ion collisions as a probe of the quark–gluon plasma formation and properties

Abstract We have studied the spin polarization of $$\Lambda $$ Λ hyperons in heavy ion collisions at center-of-mass energies $$\sqrt{s_\textrm{NN}}= 200$$ s NN = 200 GeV and $$\sqrt{s_\textrm{NN}}= 5.02$$ s NN = 5.02 TeV carried out at RHIC and LHC colliders. We have calculated the mean spin vector at local thermodynamic equilibrium, including all known first-order terms in the gradients of the thermo-hydrodynamic fields, assuming that the hadronization hypersurface has a uniform temperature. We have also included the feed-down contributions to the polarization of $$\Lambda $$ Λ stemming from the decays of polarized $$\Sigma ^*$$ Σ ∗ and $$\Sigma ^0$$ Σ 0 hyperons. The obtained results are in good agreement with the data. In general, the component of the spin vector along the global angular momentum, orthogonal to the reaction plane, shows strong sensitivity to the initial longitudinal flow velocity. Furthermore, the longitudinal component of the spin vector turns out to be very sensitive to the bulk viscosity of the plasma at the highest LHC energy. Therefore, the azimuthal dependence of spin polarization can effectively constrain the initial hydrodynamic conditions and the transport coefficients of the quark gluon plasma.

Physics↗

A Novel Microshear Geometry for Exploring the Influence of Void Swelling on the Mechanical Properties Induced by MeV Heavy Ion Irradiation

Small disks are often the specimen of choice for exposure in nuclear reactor environments, and this geometry invariably limits the types of mechanical testing that can be performed on the specimen. Recently, shear punch testing has been utilized to evaluate changes arising from neutron irradiation in test reactor environments on these small disk specimens. As part of a broader effort to link accelerated testing using ion irradiation and conventional neutron irradiation techniques, a novel microshear specimen geometry was developed for use with heavy-ion irradiated specimens. The technique was demonstrated in pure Cu irradiated to 11 and 110 peak dpa with 10 MeV Cu ions. At 11 peak dpa, the Cu specimen had a high density of small voids in the irradiated region, while at 110 peak dpa, larger voids with an average void swelling of ~20% were observed. Micropillar and microshear specimens both exhibited hardening at 11 dpa, followed by softening at 110 dpa. The close alignment of the new microshear technique and more conventional micropillar testing, and the fact that both follow intuition, is a good first step towards applying microshear testing to a wider range of irradiated materials.

36 MATERIALS SCIENCE↗

Quest for Cooper Pair Transfer in Heavy-Ion Reactions: The 206 Pb + 118 Sn Case

In this Letter we report on effects of nucleon-nucleon correlations probed in nucleon transfer reactions with heavy ions. We measured with high efficiency and resolution a complete set of observables for neutron transfer channels in the ²⁰⁶Pb + ¹¹⁸Sn system employing a large solid angle magnetic spectrometer, which allowed us to study a wide range of internuclear distances via a detailed excitation function. The coupled channel theory, based on an independent particle transfer mechanism, follows the experimental transfer probabilities for one- and two-neutron pick-up and stripping channels. The experimental two-neutron transfer cross sections indicate that in reactions between pair-vibrational (closed shell) and pair-rotational (open shell) nuclei, correlations manifest via pair-addition and pair-removal modes, which constitute one of the elementary modes of excitations in nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Thermal transport across nanoscale damage profile in sapphire irradiated by swift heavy ions

In this work, we studied the degradation of thermal conductivity in single crystal sapphire (α-Al 2 O 3 ) irradiated by 167 MeV Xe swift heavy ions (SHIs) over the multiple fluences in the range of 10 12 –10 14 ions/cm 2 . Thermal conductivity was measured primarily in the cross-plane direction using a noncontact ultrafast optical pump-probe technique called picosecond time domain thermoreflectance (TDTR). Multiple samples with variable ion fluences allowed us to probe distinct regions resulting from different regimes of microstructure evolution caused by electronic energy loss. By tuning the penetration depth of the thermal waves using different modulation frequencies, two regions with distinct conductivities were identified and the values of which were found to be consistent with phonon-mediated thermal transport models while the microstructure was confirmed by electron microscopy characterization. These damaged regions were determined to be a several micrometer thick ion track region and several tens of nanometer-thick amorphous layer present only above 5.0 × 10 13 ions/cm 2 . These results demonstrate the applicability of TDTR to resolve thermal transport behavior in SHI irradiated oxides having nonhomogeneous damage profile on a nanometer scale. The presented approach facilitates future studies aiming at resolving the impact of distinct damage resulting from electronic and nuclear stopping regimes under irradiation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Parallel-plate avalanche counters for heavy-ion beam tracking: History and mysteries

Despite being an old detector concept, position-sensitive parallel-plate avalanche counters (PPACs) remain widely used today for heavy-ion position and timing measurements. In modern rare isotope beam facilities and large-acceptance fragment separators, PPACs are used to characterize beam properties (diagnostics), facilitate beam delivery (tuning), and provide event-by-event beam tracking for particle identification (PID). Most popular particle localization methods in PPAC detectors are based on strip electrodes electrically connected to resistive-chain circuits or delay lines. More exotic systems include optical readouts based on recording electroluminescence light with high-granularity photodetector arrays or high-resolution resistive anode electrodes. PPACs with conventional resistive-chain or delay-line readouts achieve typical position and time resolutions of below 1 mm ( σ ) and around 150 ps ( σ ), respectively. In addition, delay-line systems are capable of counting rates above several hundred kHz for beam areas of a few millimeters square, and around 1 MHz for larger beam sizes. Resistive-chain readouts have limited rates of a few tens of kHz. A review of the operation principles and performance of PPAC detectors is presented in this paper. We will discuss decades-long experience building and operating PPACs developed at the National Superconducting Cyclotron Laboratory, and then refined at the Facility for Rare Isotope Beams (FRIB), mostly focusing on the delay-line readout technique (DLPPAC). We will also discuss problems that arise due to electric discharges at high rates and briefly describe ongoing developments at FRIB. Published by the American Physical Society 2024

Physics↗