At least 217 records · Page 12

TinyTPC: A TEST STAND FOR LAr DOPING

TinyTPC is a small scale liquid-argon time projection chamber (LArTPC) that studies how photosensitive dopants can improve the energy resolution of low energy events in LArTPCs. Bench tests to resolve high voltage breakdown issues and to improve the low voltage system readout are described. Experimental data with a radioactive source of Th-228 for the calibration of the pixelated readout and the characterization of TinyTPC's energy resolution is explained. Provisional results from the addition of isobutylene (photosensitive dopant) and xenon (wavelength shifter) to liquid-argon (LAr) are also presented. Further steps to improve voltage system and enhance the data collection are discussed.

Rodriguez Thorne, Paloma↗

Using a Grid-Forming Inverter to Stabilize a Low-Inertia Power System - Maui Hawaiian Island

As power systems around the world integrate greater amounts of wind and solar photovoltaic power, periods of very high instantaneous power shares of inverters, the primary interfacing technology for these generation sources, are complicating system stability and control. The contemporary, primary mode of inverter operation, grid-following, which explicitly assumes the presence of a local, stable voltage waveform, yields operational inadequacy at high instantaneous power shares potentially leading to instability due to the low-inertia conditions, as well as the correlated reduced voltage forming capacity on the respective system. Parallel connected grid-forming inverters, which directly regulate the local voltage, are a solution that is expected to bolster system stability and mitigate the shortcomings of the grid-following technology. In this paper, grid-following and two types of grid-forming inverter control, the traditional linear droop and the recently introduced nonlinear exponential droop (Droop-e), are simulated on a low-inertia, H = 0.48s, high inverter-based resource scenario, 97%, with a validated electromagentic transient domain model of the Hawaiian island of Maui power system. The benefit of a single grid-forming device over its grid-following counterpart is significant, both in terms frequency deviation and voltage stability. Further, the superiority of the Droop-e and the associated secondary power sharing control over both grid-following and linear droop grid-forming technologies is displayed, with improved nadir and rate of change of frequency over the linear droop control.

droop control↗

Toward High-Voltage Cathodes for Zinc-Ion Batteries: Discovery Pipeline and Material Design Rules

Efficient energy storage systems are crucial to address the intermittency of renewable energy sources. As multivalent batteries, Zn-ion batteries (ZIBs), while inherently low voltage, offer a promising low-cost alternative to Li-ion batteries due to the viable use of zinc as the anode. However, to maximize the potential impact of ZIBs, rechargeable cathodes with improved Zn diffusion are needed. To better understand the chemical and structural factors influencing Zn-ion mobility within battery electrode materials, we employ a high-throughput computational screening approach to systematically evaluate candidate intercalation hosts for ZIB cathodes, expanding the chemical search space on empty intercalation hosts that do not contain Zn. We leverage a high-throughput screening funnel to identify promising cathodes in ZIBs, integrating screening criteria with density functional theory (DFT)-based calculations of Zn2+ intercalation and diffusion inside the host materials. Using these data, we identify the design principles that favor Zn-ion mobility in candidate cathode materials. Building on previous work on divalent-ion cathodes, this study broadens the chemical space for next-generation multivalent energy storage systems.

electrodes↗

Early Fault Detection in Particle Accelerator Power Electronics Using Ensemble Learning

Early fault detection and fault prognosis are crucial to ensure efficient and safe operations of complex engineering systems such as the Spallation Neutron Source (SNS) and its power electronics (high voltage converter modulators). Following an advanced experimental facility setup that mimics SNS operating conditions, the authors successfully conducted 21 early fault detection experiments, where fault precursors are introduced in the system to a degree enough to cause degradation in the waveform signals, but not enough to reach a real fault. Nine different machine learning techniques based on ensemble trees, convolutional neural networks, support vector machines, and hierarchical voting ensembles are proposed to detect the fault precursors. Although all 9 models have shown a perfect and identical performance during the training and testing phase, the performance of most models has decreased in the next test phase once they got exposed to realworld data from the 21 experiments. The hierarchical voting ensemble, which features multiple layers of diverse models, maintains a distinguished performance in early detection of the fault precursors with 95% success rate (20/21 tests), followed by adaboost and extremely randomized trees with 52% and 48% success rates, respectively. The support vector machine models were the worst with only 24% success rate (5/21 tests). The study concluded that a successful implementation of machine learning in the SNS or particle accelerator power systems would require a major upgrade in the controller and the data acquisition system to facilitate streaming and handling big data for the machine learning models. In addition, this study shows that the best performing models were diverse and based on the ensemble concept to reduce the bias and hyperparameter sensitivity of individual models.

43 PARTICLE ACCELERATORS↗

A Zonal Volt/VAR Control Mechanism for High PV Penetration Distribution Systems

This paper presents a zonal Volt/VAR control scheme for regulating voltage in unbalanced 3-phase distribution systems using inverter-based resources (IBR). First, the dependency between nodal voltage changes and IBR reactive power injections is derived via voltage sensitivity studies. Then, a fast-incremental clustering method is used to divide the distribution circuit into weakly-coupled zones based on correlations between nodal voltage sensitivities. The weak-coupling allows the voltage to be regulated independently within each zone using a rule-based voltage controller to dispatch IBR for voltage corrections. Simulation results on actual distribution feeder show that the proposed zone-based Volt/VAR control method maintains system voltages within their operational limits while reducing the runtime of the Volt/VAR controller from tens of second to a couple of milliseconds compared with centralized, optimization-based Volt/VAR control methods.

Alrushoud, Asmaa↗

A Station-hybrid HVDC System Structure and Control Strategies for Cross-seam Power Transmission

Cross-seam high voltage DC (HVDC) transmission in the United States can provide an efficient and flexible bulk power delivery highway between the interconnections. Recent studies have shown significant economic benefits of cross-seam HVDC transmission systems by taking the advantages of load diversity, frequency response, renewable energy diversity, and energy arbitrage in the different interconnections. This paper introduces a station-hybrid system scheme for cross-seam interconnections. Here, the proposed station-hybrid system combines the advantages of line commutated converter (LCC) and voltage source converter (VSC) technologies, thus enabling reliable and flexible bidirectional power flows across the interconnections. Control strategies of the station-hybrid system are investigated with a focus on power flow reversal control under normal operation conditions and grid support control under emergency conditions. The feasibility and effectiveness of the proposed station-hybrid system and corresponding control strategies are verified by simulations in PSCAD/EMTDC.

Station-hybrid system↗

Pressure Response Optimization of an Eddy Current-Driven Flyer Plate Valve for the ITER Shattered Pellet Injection System

One technique for mitigating disruptions in a tokamak is shattered pellet injection (SPI). SPI is a process in which a large solid pellet consisting of deuterium, neon, or argon is desublimated in a pipe gun barsrel and launched downstream. Pellets are shattered just before entering the plasma by an impact with an angled tube. Injection of these materials into the plasma radiates stored thermal energy, limits current decay rates, suppresses the generation of runaway electrons, and dissipates runaway electrons if necessary. A critical element of the SPI system is a fast-acting valve that releases high-pressure gas to dislodge and accelerate pellets directly, or indirectly via a mechanical punch. A prototype valve sized for the ITER SPI system has been designed and fabricated. A pulsed high-voltage power supply energizes the valve’s internal magnetic coil, which induces eddy currents in the adjacent flyer plate resulting in a repulsive force between the flyer plate and the coil. The flyer plate action lifts a valve seat, allowing high-pressure gas to flow from the valve plenum to the downstream (breech) location of the pellet or mechanical punch. All of the valve’s internal components are designed to operate in ITER-level static background magnetic fields. Here, a study was conducted to optimize the downstream pressure response for a range of valve sizes and operating pressures. In particular, the study analyzes the breech pressure response associated with varying plenum pressures as well as varying breech volumes. A computational fluid dynamics simulation was built in STAR-CCM+ and validated against data from laboratory experiments. The resulting simulation outputs, in the form of downstream responses for a variety of initial plenum pressures and breech volumes, will be used as a complement to experimental data to ensure the pressure pulse is suitable for pellet survivability. These data, combined with studies on pellet shear strength and shock response, will be applied to optimization of overall operating parameters of the ITER SPI system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Status of LBNF/DUNE near site liquid argon proximity and external cryogenics systems development.

The Deep Underground Neutrino Experiment (DUNE) near site located at Fermilab will host the neutrino beam complex. It includes a high voltage liquid argon time projection chamber located 60-meter underground used as beamline instrumentation. The LAr cryogenic system provided by the Long-Baseline Neutrino Facility (LBNF) regulates thermohydraulic conditions of the membrane cryostat hosting the detector with 285 Ton purified LAr. The purification system uses molecular sieve and copper oxide pellets to manage the argon contamination below 100 ppt (parts per trillion) oxygen equivalent. The detector and its cryogenics are capable to move a stroke of 30 meters on/off beam. The cryogenic system modes of operation include the cryostat pressure test, purge in open loop, detector cooldown, cryostat fill, closed loop purification, liquid empty, and purification system activation/regeneration process. The system design status and schedule, and technical details such as operating modes and interfaces are reported in this paper.

43 PARTICLE ACCELERATORS↗

A Real-Time Testbed for Smart Inverter Cyber Security Studies

Distributed energy resources (DER) have become a popular solution to modern-day issues surrounding the efficiency and reliability of power generation, as well as climate change concerns. Energy centers are shifting towards incorporating smart inverters with embedded functionalities such as high voltage ride through (HVRT), low voltage ride through (LVRT), active and reactive power compensation. However, the integration of smart inverters leave DER systems highly vulnerable to cybersecurity threats. The distributed network protocol 3 (DNP3) is a common method of communication between grid-tied hardware. Despite its popularity, the level of security leaves all hardware connected to the grid at risk of severe cyber-attacks. Thus, it is important to study any potential cybersecurity threats towards grid-tied smart inverters to mitigate cybersecurity vulnerabilities and refine existing cyber-security protections. This report describes the proposed testbed design to study cybersecurity threats to smart inverters. The testbed utilizes a real-time simulation case in RSCAD that includes a grid-tied wind turbine (WT) topology featuring two back-to-back two-level voltage source converters (BTB,2L-VSCs) and a permanent magnet synchronous machine (PMSM). The simulated case runs within the NovaCor real time digital simulator (RTDS). This report focuses on the design and implementation of a single module of the GTNETx2 card as a distributed network protocol and the configuration of an IEEE 1518 DNP database file that includes input and output variables mapped to different connection points in the grid that transmit and receive discrete, analog, and binary signals on command. This allows realistic emulation of the communication between the smart inverter and the grid for cybersecurity studies.

97 MATHEMATICS AND COMPUTING↗

Statistical characterization of high voltage vacuum surface flashover with gapped and ungapped anodes

This manuscript reports the experimental study of a novel vacuum high-voltage (HV) feedthrough geometry with a recessed anode triple junction (ATJ) relevant to large-scale pulsed power systems. It is shown experimentally that introducing a vacuum gap between the insulator–anode interface and recessing the ATJ farther away from the cathode triple junction significantly enhances high voltage (HV) vacuum surface flashover hold-off. The results for “first pulse” and “consecutive pulse” tests are reported. The physical mechanisms contributing to the electrical failure of this feedthrough geometry appear to be unique to this geometry. These findings show the potential to allow for HV vacuum surface flashover geometries with significantly improved electrical characteristics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Reliable, Cost-Effective Transformerless Medium-Voltage Inverter for Grid Integration of Combined Solar and Energy Storage

The goal of this project is to utilize an innovative holistic power electronic inverter design approach, which can leverage best-in-class silicon carbide (SiC) power modules, novel multi-level power electronic circuits, high frequency transformers, switching sequence based control and co-designed electro-thermal management methods, to realize a 300 kW transformerless medium-voltage (MV) inverter system. The system cost of the inverter is considered as a primary design objective alongside high power density, efficiency, low electromagnetic interference (EMI) and long lifespan. This design-oriented research activity, especially the proposed multi-objective optimization approach, will have broad impacts in holistic power electronic system design methods and in technologies that can be commercialized into a wide variety of wide bandgap power electronic applications.

14 SOLAR ENERGY↗

Chapter 11: Renewable Microgrids as a Foundation of the Future Sustainable Electrical Energy System

Renewable microgrids are an integral part of the future sustainable energy system. This chapter focuses on the role of renewable energy-based microgrids in the electricity system transformation. It is seen as a foundation that complements large-scale generation plants and high-voltage transmission lines by providing additional flexibility and resilience. This flexibility and resilience are crucial for balancing the energy system and ensuring its long-term sustainability, given the changing supply and demand patterns due to rooftop solar photovoltaics (PV), battery storage, electric mobility, and heat pumps. It is also an opportunity for residential and commercial consumers to become active participants in the energy market. Innovation, new technologies and business models will act as the key enabler for this transformation. The regulatory restructuring of the energy market will be crucial for successful integration of prosumers and aggregated energy communities. The chapter presents the vision of a sustainable, decentralized, and digitized energy future including market potential, most innovative case study projects and start-up companies, and the shifts needed in the regulatory landscape.

battery storage↗

A flexible test facility for liquid xenon detector development

As liquid xenon time projection chambers scale to ever-larger sizes, so too do the engineering challenges they pose. Here, we describe a large, flexible, multipurpose test facility capable of supporting the development of a number of key aspects of liquid xenon detector systems. Example applications of this facility include characterization of large-area light and charge sensor arrays, tests of xenon purification techniques and materials compatibility, and investigations into high-voltage phenomena. This facility uses an automated and remotely monitored cryo-cooling system based on immersion of the test chamber in a liquid bath rather than conductive coupling, leading to advantages in temperature and pressure stability, as well as increasing required response times in the case of cooling-power loss. Design advantages, operational procedures, and performance of the facility are described, as well as five examples of liquid xenon test chambers that use the facility.

Dark Matter detectors↗

Dicarbonyl Electrolyte for High-Voltage Lithium Metal Batteries: Importance of the Entropy of Solvation in Bidentate Solvent

An electrolyte system based on dicarbonyl solvents has been proposed and implemented in lithium metal batteries (LMBs). Among several dicarbonyl solvents explored, dimethyl dicarbonate (DMDC) emerged as the most promising electrolyte candidate. Interestingly, despite the structural similarities between DMDC and its monocarbonyl counterpart DMC, the DMDC electrolyte exhibits higher solvent coordination, even at the same lithium-to-carbonyl ratio. Further, this leads to the formation of a more robust solid-electrolyte interphase and enhances the anodic stability of the electrolyte. Notably, in various electrolyte systems, the solvation energy is typically enthalpy-driven. However, the bidentate nature of DMDC introduces a significant role for the entropy of solvation because the Li + -DMDC complexes release fewer free molecules. With the addition of non-solvating co-solvent 1,1,2,2-tetrafluoro-ethyl 2,2,3,3-tetrafluoro-propyl ether (TTE), which reduces the viscosity of the electrolyte, the DMDC-TTE system enables remarkably stable cycling of the lithium anode by manipulating the entropy of solvation. This introduces a new strategy for tailoring functional electrolyte systems.

25 ENERGY STORAGE↗

Operation of Dual-T-Type Modular Multilevel Converter for Uninterrupted Power Supply Under Bridge Failures

Dual-T-type modular multilevel converter (DTMMC) is an alternative to the existing uninterrupted power supply (UPS) due to its advantage in flexible leg reusing, multiple power ports, and high operating efficiency. Here, in this article, a DTMMC-UPS, which has series configurations on both input/output ac sides, obtains high-voltage grid/load accessing interfaces is presented. In the described system, the fact that copies of T-type legs are employed makes semiconductor failure common to happen. Moreover, both the coupling between rectifier and inverter conversions and the confliction between intercell and inner-cell voltage balancing make fault-tolerant control a tough issue. In this article, the switch fault types are first clarified and diagnosed by the different impacts on normal operation. An improved voltage vector modulation is then deduced to facilitate the planning of proper primary switching patterns, to achieve rectifier side normal operation. The secondary alternated level-shifted pulsed-width modulation (LS-PWM) is also modified to achieve inverter side normal operation. The experiment results are supplied to verify the validity of the modulation-coordinated fault toleration strategy.

42 ENGINEERING↗

Portable Soft X-Ray Diagnostics for Transformative Fusion-Energy Concepts (Final Scientific/Technical Report)

A time-gated extreme-ultraviolet spectrometer was fielded on a transformative fusion-energy device, FuZE-Q at Zap Energy, Inc. (ZEI), a sheared-flow-stabilized z-pinch. Plasma emission spectra were collected in the 5–40 nm wavelength (30–250 eV) range. This was the first time a direct-vacuum-coupled, high-voltage, deposition-sensitive diagnostic was fielded on this type of dense-plasma fusion device. To overcome the special challenges of such a coupling, a unique, highly effective implementation was developed, with fast (10-ns risetime) pulsed high-voltage electronics and a multi-stage differential pumping system. This enabled the UNR spectrometer to collect three independently timed spectra per FuZE-Q shot while also protecting sensitive internal components. Analysis of line emission identified oxygen (N-, C-, B-, Be-, Li-, and He-like O), peaking in intensity shortly after maximum current (>500 kA). Spectral databases and collisional-radiative modeling have been used to identify impurities and estimate edge-plasma temperatures.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Digital Twin Based Condition Monitoring of LCC-LCC Inductive Power Transfer Systems

Inductive power transfer (IPT) systems provide a flexible, hands-free charging opportunity to electric vehicles (EV). The resonant network components and the transmitter and receiver coils are often subjected to high voltages or currents. Component aging in the compensation network and coils of resonant IPT systems is detrimental to the reliability and power transfer efficiency of the IPT system. Monitoring the component health of such multi-element complex systems requires robust optimization algorithms. This paper discusses condition monitoring of a resonant IPT system for an EV charger using a digital twin model. A hybrid estimation algorithm based on genetic algorithms and adaptive particle swarm optimization is developed to estimate the parameters of the digital twin model. Simulation results are used to verify the monitoring capabilities of the developed algorithm under various operating conditions of the IPT system.

Weldehawaryat, Lidya Mussie [graduate research ass↗

Renewable Integration in Hybrid ac-dc Systems using Multi-port Autonomous Reconfigurable Solar power plant (MARS)

To increase inertia and improve primary frequency response of future grids, grid-forming inverters connecting PV to grid and energy storage systems (ESSs) are likely to play an important role. Moreover, high-voltage direct current (HVdc) links will also be an enabler to transfer remote PV generation and for improved grid stability. That is, with increased penetration of PV, discrete development of PV and ESS connecting to transmission ac grid and HVdc links is one of the solutions for stable operation of grid. Here, an integrated concept for integration of PV and ESS to transmission ac grid and HVdc links is proposed that is named as multi-port autonomous reconfigurable solar power plant (MARS). The proposed integrated development reduces the cost associated with respect to discrete development of PV-ESS systems connecting to transmission ac grid and HVdc links. The integrated development incorporates advanced control methods to provide inertial and primary frequency response, reactive power support, and transient stability to manage PV and ESS resources. In this paper, high-fidelity switched system model of the integrated system and grids are developed and detailed simulation results are provided to showcase the stable operation of the integrated system and provision of grid support functions.

14 SOLAR ENERGY↗