Search NASA⌕ Search

SEARCH · Search NASA

Results for “HISTOGRAM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

A Systematic Post-QUANTEC Review of Tolerance Doses for Late Toxicity After Prostate Cancer Radiation Therapy

The aims of this study were to systematically review tolerance doses for late distinct gastrointestinal (GI), genitourinary (GU), and sexual dysfunction (SD) symptoms after external beam radiation therapy (EBRT) alone and treatments involving brachytherapy (BT) for prostate cancer after Quantitative Analysis of Normal Tissue Effects in the Clinic (QUANTEC) and ultimately to perform quantitative syntheses of identified dose/volume tolerances represented by dose-volume histogram (DVH) thresholds, that is, statistically significant (P ≤ .05) cutoff points between symptomatic and asymptomatic patients in a certain study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose Summation Strategies for External Beam Radiation Therapy and Brachytherapy in Gynecologic Malignancy: A Review from the NRG Oncology and NCTN Medical Physics Subcommittees

Definitive, nonsurgical management of gynecologic malignancies involves external beam radiation therapy (EBRT) and/or brachytherapy (BT). Summation of the cumulative dose is critical to assess the total biologic effective dose to targets and organs at risk. Cumulative dose calculation from EBRT and BT can be performed with or without image registration (IR) and biologic dose summation. Among these dose summation strategies, linear addition of dose-volume histogram (DVH) parameters without IR is the global standard for composite dose reporting. This approach stems from an era without image guidance and simple external beam and brachytherapy treatment approaches. With technological advances, EBRT and high-dose-rate BT have evolved to allow for volume-based treatment planning and delivery. Modern conformal therapeutic radiation involves volumetric or intensity modulated EBRT, capable of simultaneously treating multiple targets at different specified dose levels. Therefore, given the complexity of modern radiation treatment, the linear addition of DVH parameters from EBRT and high-dose-rate BT is challenging to represent the combined dose distribution. Deformable image registration (DIR) between EBRT and image guided brachytherapy (IGBT) data sets may provide a more nuanced calculation of multimodal dose accumulation. However, DIR is still nascent in this regard, and needs further development for accuracy and efficiency for clinical use. Biologic dose summation can combine physical dose maps from EBRT and each IGBT fraction, thereby generating a composite DVH from the biologic effective dose. However, accurate radiobiologic parameters are tissue-dependent and not well characterized. A combination of voxel-based DIR and biologic weighted dose maps may be the best approximation of dose accumulation but remains invalidated. The purpose of this report is to review dose summation strategies for EBRT and BT, including conventional equivalent dose in 2-Gy fractions dose summation without image registration, physical dose summation using 3-dimensional rigid IR and DIR, and biologic dose summation. We also provide general clinical workflows for IGBT with a focus on cervical cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Electron Backscatter Diffraction Analysis of Grain Boundary Initiated Discontinuous Precipitation in U-10Mo

The effect of varied thermomechanical processing on discontinuous precipitation (DP) in U-10Mo was investigated, with specific emphasis on understanding the role of grain boundary misorientation in DP. Varied prior homogenization heat treatment and thermomechanical processing resulted in differences in both the fraction of DP and the colony width, and was attributed to variations in the grain boundary misorientation distribution. Regardless of the degree of DP-based transformation, extensive growth of DP colonies was dominant on 30°–45° misorientation boundaries. Interestingly, misorientation histograms of the deformed and annealed specimens suggest the processing steps involved may have inhibited DP colony growth along a small fraction of these high angle boundaries. Large-area electron backscatter diffraction montages coupled with high resolution mapping suggest symmetric {110}-type interfaces may be important considerations for mitigating extensive DP growth in this alloy system.

Discontinuous Precipitation, Uranium, Electron Bac↗

Uranium Oxide Synthetic Pathway Discernment through Unsupervised Morphological Analysis

We present a novel unsupervised machine learning method for quantitative representation of scanning electron micrographs and its applications and performance for nuclear forensic analysis of uranium ore concentrates. The method uses a vector quantizing variational autoencoder followed by a histogram operation to encode a micrograph into a single dimensional representation, called the latent vector. The method requires no extant labeling of the data and can be applied over large datasets of micrographs with minimal human interaction. The representations generated are broadly descriptive of each micrograph and the microstructure of the material imaged. In the case of uranium ore concentrate analysis, the representations were amenable to processing reagent and ore concentrate species classification with accuracy of 81:8%, which is competitive with state-of-the-art supervised networks. The representations were also used to classify previously unseen processing routes, were able to classify imaging parameters such as magnification (to 76:0% accuracy), were able to classify fine grained process parameters such as calcining temperature (to 74:4% accuracy), and their informatic properties indicate that they are generally descriptive of the image represented. This method can be applied across microstructure analysis fields to perform quantitative analysis without the need for labor intensive and possibly biased human analysis.

Scanning Electron Microscopy, Vector Quantizing Va↗

Prediction of electric and magnetic fields from spectral data using machine learning algorithms for Doppler-free saturation spectroscopy diagnostics

The prediction of electric and magnetic field amplitudes from atomic spectral data is critical for plasma control in fusion devices such as tokamaks. Conventional approaches that rely on physics-based models are computationally expensive and unsuitable for real-time applications. In this work, we develop and benchmark three machine learning algorithms—simulation-based inference (SBI), fully connected neural networks (FCNN), and histogram-based gradient boosting regression (GBR-Hist)—to infer field intensities directly from Doppler-free saturation spectroscopy (DFSS) spectra. Synthetic datasets of spectra were generated using the EZSSS code and evaluated both with and without added Poisson noise to mimic experimental conditions. We find that SBI achieves the highest accuracy and robustness, FCNN provides a strong balance of accuracy and computational efficiency for real-time applications, and GBR-Hist offers the fastest inference but is more sensitive to noise. Furthermore, these results demonstrate the potential of machine learning to accelerate DFSS analysis and enhance its utility for plasma diagnostics and control.

Doppler-free saturation spectroscopy↗

Microstructural evolution and grain growth kinetics of GZ31 magnesium alloy

Grain growth behavior of Mg–3Gd–1Zn (GZ31) magnesium alloy was studied in a wide range of annealing time and temperature to clarify the kinetics of grain growth, microstructural evolution and related metallurgical phenomena. This material exhibited typical normal grain growth mode under annealing conditions with annealing temperature of lower than 300 °C and soaking time of lower than 240 min. However, the abnormality in grain growth was also evident at annealing temperature of 400 °C and 500 °C. The dependence of abnormal grain growth (AGG) at mentioned annealing temperatures upon microstructural features such as dispersed precipitates, which were rich in Zn and Gd, was investigated by optical micrographs, X-ray diffraction patterns, scanning electron microscopy images, and energy dispersive X-ray analysis spectra. The bimodality in grain-size distribution histograms also signified the occurrence of AGG. Based on the experimental data on grain growth obtained by annealing treatments, the grain growth exponent and the activation energy were also figured out.

36 MATERIALS SCIENCE↗

Gaussian kernel density functions for compositional quantification in atom probe tomography

Highlights: • A methodology for compositional quantification from atom probe tomography is proposed. • A probability density function p(x) given discrete data points is constructed. • Each atom approximated by a Gaussian function with a particular smoothing parameter. • Density Kernel functions are used to find the optimum smoothing parameter. • The method is validated by using simulated data of semiconductor materials. - Abstract: Atom probe tomography (APT) has the ability to identify the nature and position of single atoms in a material with an almost 3D atomic resolution. However, the quantification of the material composition requires an appropriate treatment of the discrete APT data. When the amount of atoms selected to quantify the composition is relatively small, the spatial resolution is enhanced but the statistical error worsens. Conversely, the increase in the number of atoms considered reduces the spatial resolution, but improving the statistics. We have developed a methodology to reach an optimum equilibrium between the positional and the statistical error in an unsupervised form using Gaussian Kernel density functions. The validity of the method has been tested using APT simulated data of semiconductor materials. It has been proved that the chemical quantification in these materials requires the appropriate selection of the smoothing parameter, obtained without user intervention. In addition, the results have been compared to the usual techniques for composition measurement from APT data (voxelization and proximity histograms), showing better precision for high spatial resolution. This work supplies a data driven methodology based in Gaussian Kernel density functions for the accurate quantification of the composition from APT data.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Clinical and dosimetric implications of intensity-modulated radiotherapy for early-stage glottic carcinoma

Conventional parallel-opposed radiotherapy (PORT) is the established standard technique for early-stage glottic carcinoma. However, case reports have reported the utility of intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) with or without image guidance (image-guided radiotherapy, IGRT) in select patients. The proposed advantages of IMRT/VMAT include sparing of the carotid artery, thyroid gland, and the remaining functional larynx, although these benefits remain unclear. The following case study presents a patient with multiple vascular comorbidities treated with VMAT for early-stage glottic carcinoma. A detailed explanation of the corresponding treatment details, dose-volume histogram (DVH) analysis, and a review of the relevant literature are provided. Conventional PORT remains the standard of care for early-stage glottic carcinoma. IMRT or VMAT may be beneficial for select patients, although great care is necessary to avoid a geographical miss. Clinical data supporting the benefit of CRT are lacking. Therefore, these techniques should be used with caution and only in selected patients.

61 RADIATION PROTECTION AND DOSIMETRY↗

Using individual patient anatomy to predict protocol compliance for prostate intensity-modulated radiotherapy

If a prostate intensity-modulated radiation therapy (IMRT) or volumetric-modulated arc therapy (VMAT) plan has protocol violations, it is often a challenge knowing whether this is due to unfavorable anatomy or suboptimal planning. This study aimed to create a model to predict protocol violations based on patient anatomical variables and their potential relationship to target and organ at risk (OAR) end points in the setting of definitive, dose-escalated IMRT/VMAT prostate planning. Radiotherapy plans from 200 consecutive patients treated with definitive radiation for prostate cancer using IMRT or VMAT were analyzed. The first 100 patient plans (hypothesis-generating cohort) were examined to identify anatomical variables that predict for dosimetric outcome, in particular OAR end points. Variables that scored significance were further assessed for their ability to predict protocol violations using a Classification and Regression Tree (CART) analysis. These results were then validated in a second group of 100 patients (validation cohort). In the initial analysis of the hypothesis-generating cohort, percentage of rectum overlap in the planning target volume (PTV) (%OR) and percentage of bladder overlap in the PTV (%OB) were highlighted as significant predictors of rectal and bladder dosimetry. Lymph node treatment was also significant for bladder outcomes. For the validation cohort, CART analysis showed that %OR of < 6%, 6% to 9% and > 9% predicted a 13%, 63%, and 100% rate of rectal protocol violations respectively. For the bladder, %OB of < 9% vs > 9% is associated with 13% vs 88% rate of bladder constraint violations when lymph nodes were not treated. If nodal irradiation was delivered, plans with a %OB of < 9% had a 59% risk of violations. Percentage of rectum and bladder within the PTV can be used to identify individual plan potential to achieve dose-volume histogram (DVH) constraints. A model based on these factors could be used to reduce planning time, improve work flow, and strengthen plan quality and consistency.

61 RADIATION PROTECTION AND DOSIMETRY↗

Pancreatic cancer planning: Complex conformal vs modulated therapies

To compare the roles of intensity-modulated radiation therapy (IMRT) and volumetric- modulated arc therapy (VMAT) therapy as compared to simple and complex 3-dimensional chemoradiotherpy (3DCRT) planning for resectable and borderline resectable pancreatic cancer. In all, 12 patients who received postoperative radiotherapy (8) or neoadjuvant concurrent chemoradiotherapy (4) were evaluated retrospectively. Radiotherapy planning was performed for 4 treatment techniques: simple 4-field box, complex 5-field 3DCRT, 5 to 6-field IMRT, and single-arc VMAT. All volumes were approved by a single observer in accordance with Radiation Therapy Oncology Group (RTOG) Pancreas Contouring Atlas. Plans included tumor/tumor bed and regional lymph nodes to 45 Gy; with tumor/tumor bed boosted to 50.4 Gy, at least 95% of planning target volume (PTV) received the prescription dose. Dose-volume histograms (DVH) for multiple end points, treatment planning, and delivery time were assessed. Complex 3DCRT, IMRT, and VMAT plans significantly (p < 0.05) decreased mean kidney dose, mean liver dose, liver (V{sub 30}, V{sub 35}), stomach (D{sub 10}%), stomach (V{sub 45}), mean right kidney dose, and right kidney (V{sub 15}) as compared with the simple 4-field plans that are most commonly reported in the literature. IMRT plans resulted in decreased mean liver dose, liver (V{sub 35}), and left kidney (V{sub 15}, V{sub 18}, V{sub 20}). VMAT plans decreased small bowel (D{sub 10}%, D{sub 15}%), small bowel (V{sub 35}, V{sub 45}), stomach (D{sub 10}%, D{sub 15}%), stomach (V{sub 35}, V{sub 45}), mean liver dose, liver (V{sub 35}), left kidney (V{sub 15}, V{sub 18}, V{sub 20}), and right kidney (V{sub 18}, V{sub 20}). VMAT plans significantly decreased small bowel (D{sub 10}%, D{sub 15}%), left kidney (V{sub 20}), and stomach (V{sub 45}) as compared with IMRT plans. Treatment planning and delivery times were most efficient for simple 4-field box and VMAT. Excluding patient setup and imaging, average treatment delivery was within 10 minutes for simple and complex 3DCRT, IMRT, and VMAT treatments. This article shows significant improvements in 3D plan performance with complex planning over the more frequently compared 3- or 4-field simple 3D planning techniques. VMAT plans continue to demonstrate potential for the most organ sparing. However, further studies are required to identify if dosimetric benefits associated with inverse optimized planning can be translated into clinical benefits and if these treatment techniques are value-added therapies for this group of patients with cancer.

61 RADIATION PROTECTION AND DOSIMETRY↗

Technical solutions to reduce mediastinal irradiation in young patients undergoing treatment for lymphomas: Preliminary experience

This study aims at optimizing treatment planning in young patients affected by lymphoma (Stage II to III) by using an inclined board (IB) that allows reducing doses to the organs at risk. We evaluated 19 young patients affected by stage I to III lymphomas, referred to our Department for consolidation radiotherapy (RT) treatment on the mediastinum. Patients underwent 2 planning computed tomography (CT) scans performed in different positions: flat standard position and inclined position. A direct comparison between the different treatment plans was carried out analyzing dosimetric parameters obtained from dose-volume histograms generated for each plan. Comparison was performed to evaluate the sparing obtained on breast and heart. Dosimetric evaluation was performed for the following organs at risk (OARs): mammary glands, lungs, and heart. A statistically significant advantage was reported for V{sub 5}, V{sub 20}, and V{sub 30} for the breast when using the inclined board. A similar result was obtained for V{sub 5} and V{sub 10} on the heart. No advantage was observed in lung doses. The use of a simple device, such as an inclined board, allows the optimization of treatment plan, especially in young female patients, by ensuring a significant reduction of the dose delivered to breast and heart.

61 RADIATION PROTECTION AND DOSIMETRY↗

The comparison of 5-field conformal radiotherapy techniques for the treatment of prostate cancer: The best for femoral head sparing

External radiotherapy is a standard treatment procedure for localized prostate cancer. Given the relatively high long term survival treatment complications have been brought in center of attention. In this planning study, between 2012 and 2014, CT simulation data of 90 consecutive high-risk prostate cancer patients were collected. In the first phase, all were planned for whole pelvis irradiation up to 46Gy in 23 daily fractions. In the second phase, only the prostate gland was the target of radiation. Next, the subjects were divided randomly into three groups and each received a unique 5field conformal radiation plan including Plan A (Gantry angle: 0, 60, 120, 240, and 300), Plan B (Gantry angles: 0, 90, 120, 240, and 270) and Plan C (Gantry angles: 0, 60, 90, 270, and 300). The total dose was 70Gy. For each patient, the rectum, bladder, and both femoral heads were contoured as the at risk organs (OAR). From dose volume histograms, the proportional dose of PTV V100, the bladder and rectum V80 and V90 and femoral head V50 and V100 were calculated in all subjects and compared across plans. A statistically significant difference in the femoral head V50 and V100 was found between our studied 5field plans so that in Plan A (beam angles: 0, 60, 120, 240 and 300) less dose was received by both heads of femur. This study suggests that 5 field treatment planning including an anterior, two anterior oblique and two posterior oblique portals to be more proper for 3D conformal radiotherapy in order to spare femoral head with acceptable PTV coverage, and bladder and rectal doses.

61 RADIATION PROTECTION AND DOSIMETRY↗

Neurovascular bundle–sparing radiotherapy for prostate cancer using MRI-CT registration: A dosimetric feasibility study

Purpose: Sexual dysfunction after radiotherapy for prostate cancer remains an important late adverse toxicity. The neurovascular bundles (NVB) that lie posterolaterally to the prostate are typically spared during prostatectomy, but in traditional radiotherapy planning they are not contoured as an organ-at-risk with dose constraints. Our goal was to determine the dosimetric feasibility of “NVB-sparing” prostate radiotherapy while still delivering adequate dose to the prostate. Methods: Twenty-five consecutive patients with prostate cancer (with no extraprostatic disease on pelvic magnetic resonance imaging [MRI]) who that were treated with external beam radiotherapy, with the same primary planning target volume margins, to a dose of 79.2 Gy were evaluated. Pelvic MRI and simulation computed tomography scans were registered using dedicated software to allow for bilateral NVB target delineation on T2-weighted MRI. A volumetric modulated arc therapy plan was generated using the NVB bilaterally with 2 mm margin as an organ to spare and compared to the patient’s previously delivered plan. Dose-volume histogram endpoints for NVB, rectum, bladder, and planning target volume 79.2 were compared between the 2 plans using a 2-tailed paired t-test. Results: The V70 for the NVB was significantly lower on the NVB-sparing plan (p <0.01), while rectum and bladder endpoints were similar. Target V100% was similar but V{sub 105%} was higher for the NVB-sparing plans (p <0.01). Conclusions: “NVB-sparing” radiotherapy is dosimetrically feasible using CT-MRI registration, and for volumetric modulated arc therapy technology — target coverage is acceptable without increased dose to other normal structures, but with higher target dose inhomogeneity. The clinical impact of “NVB-sparing” radiotherapy is currently under study at our institution.

61 RADIATION PROTECTION AND DOSIMETRY↗

Pencil beam scanning proton therapy vs rotational arc radiation therapy: A treatment planning comparison for postoperative oropharyngeal cancer

Patients diagnosed with head and neck cancer are traditionally treated with photon radiotherapy. Proton therapy is currently being used clinically and may potentially reduce treatment-related toxicities by minimizing the dose to normal organs in the treatment of postoperative oropharyngeal cancer. The finite range of protons has the potential to significantly reduce normal tissue toxicity compared to photon radiotherapy. Seven patients were planned with both proton and photon modalities. The planning goal for both modalities was achieving the prescribed dose to 95% of the planning target volume (PTV). Dose-volume histograms were compared in which all cases met the target coverage goals. Mean doses were significantly lower in the proton plans for the oral cavity (1771 cGy photon vs 293 cGy proton, p < 0.001), contralateral parotid (1796 cGy photon vs 1358 proton, p < 0.001), and the contralateral submandibular gland (3608 cGy photon vs 3251 cGy proton, p = 0.03). Average total integral dose was 9.1% lower in proton plans. The significant dosimetric sparing seen with proton therapy may lead to reduced side effects such as pain, weight loss, taste changes, and dry mouth. Prospective comparisons of protons vs photons for disease control, toxicity, and patient-reported outcomes are therefore warranted and currently being pursued.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric comparison of single-beam multi-arc and 2-beam multi-arc VMAT optimization in the Monaco treatment planning system

The purpose of this study was to evaluate the dosimetric and practical effects of the Monaco treatment planning system “max arcs-per-beam” optimization parameter in pelvic radiotherapy treatments. We selected for this study a total of 17 previously treated patients with a range of pelvic disease sites including prostate (9), bladder (1), uterus (3), rectum (3), and cervix (1). For each patient, 2 plans were generated, one using an arc-per-beam setting of “1” and another with an arc-per-beam setting of “2” using the volumes and constraints established from the initial clinical treatments. All constraints and dose coverage objects were kept the same between plans, and all plans were normalized to 99.7% to ensure 100% of the planning target volume (PTV) received 95% of the prescription dose. Plans were evaluated for PTV conformity, homogeneity, number of monitor units, number of control points, and overall plan acceptability. Treatment delivery time, patient-specific quality assurance procedures, and the impact on clinical workflow were also assessed. We found that for complex-shaped target volumes (small central volumes with extending arms to cover nodal regions), the use of 2 arc-per-beam (2APB) parameter setting achieved significantly lower average dose-volume histogram values for the rectum V{sub 20} (p = 0.0012) and bladder V{sub 30} (p = 0.0036) while meeting the high dose target constraints. For simple PTV shapes, we found reduced monitor units (13.47%, p = 0.0009) and control points (8.77%, p = 0.0004) using 2APB planning. In addition, we found a beam delivery time reduction of approximately 25%. In summary, the dosimetric benefit, although moderate, was improved over a 1APB setting for complex PTV, and equivalent in other cases. The overall reduced delivery time suggests that the use of mulitple arcs per beam could lead to reduced patient-on-table time, increased clinical throughput, and reduced medical physics quality assurance effort.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluation of deformed image-based dose calculations for adaptive radiotherapy of nasopharyngeal carcinoma

The ultimate goal of adaptive radiotherapy (ART) is to deliver truly customized radiation treatments. Currently, the quality of cone-beam computed tomography (CBCT) images is still inferior to that of conventional CT images in contour delineations and dose calculations for replanning purposes. This retrospective study aims to evaluate the dosimetric accuracy of using deformed conventional CT images for dose calculations, in the hope of inferring the feasibility of ART using planning CT (PCT) images that deformed to up-to-date CBCT images for patients with nasopharyngeal carcinoma (NPC). Thirty consecutive patients with NPC who had undergone 1 replan in their radiotherapy treatments were selected. The pretreatment PCT images were deformed to match the mid-treatment PCT images by deformable image registration. The same volumetric modulated arc therapy plan was then calculated on the deformed PCT images. The resulting dose distributions and dose volume histograms of the tumors and organs at risk (OARs) were compared with the original plan. Five dose levels, D{sub 98%}, D{sub 95%}, D{sub 50%}, D{sub 5%}, and D{sub 2%}, were recorded for 9 NPC targets. Four dose levels, D{sub max}, D{sub 10%}, D{sub 50%}, and D{sub mean}, were recorded for 15 OARs. The greatest percentage difference in observed dose for D{sub 98%}, D{sub 95%}, D{sub 50%}, D{sub 5%}, and D{sub 2%} of the targets were 1.71%, 1.55%, 0.64%, 0.97%, and 1.13%, respectively. The greatest percentage difference in observed dose for D{sub max}, D{sub 10%}, D{sub 50%}, and D{sub mean} of the OARs were -26.51% (left optic nerve), -17.06% (left optic nerve), 56.70% (spinal cord), and 18.97% (spinal cord), respectively. In addition, 29 of 45 (64%) dosimetric end points of the targets showed statistically significant dose differences (p p < 0.05). Dose calculations using deformed PCT images could result in significant dose uncertainties in target volumes and OARs. Larger dose deviations were found in OARs in comparison with target volumes. The spinal cord and optic nerve showed the greatest percentage dose differences and the clinical significance has yet to be determined. Deformable registration error was believed to be the problem causing the dose deviations. Owing to unknown clinical significanceof dose deviation results obtained from this study, a conventional CT scan is still required for replanning in patients with NPC who are experiencing significant anatomical changes during the course of radiation treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric benefits of automation in the treatment of lower thoracic esophageal cancer: Is manual planning still an alternative option?

This study aimed to design automated volumetric-modulated arc therapy (VMAT) plans in Pinnacle auto-planning and compare it with manual plans for patients with lower thoracic esophageal cancer (EC). Thirty patients with lower thoracic EC were randomly selected for replanning VMAT plans using auto-planning in Pinnacle treatment planning system (TPS) version 9.10. Historical plans of these patients were then compared. Dose-volume histogram (DVH) statistics, dose uniformity, and dose homogeneity were analyzed to evaluate treatment plans. Auto-planning was superior in terms of conformity index (CI) and homogeneity index (HI) for planning target volume (PTV), significantly improving 8.2% (p = 0.013) and 25% (p = 0.007) compared with manual planning, respectively, and decreasing dose of heart and liver irradiated by 20 to 40 Gy and 5 to 30 Gy, respectively (p max ) of spinal cord by 6.9 Gy compared with manual planning (p = 0.000). Additionally, manual planning showed the significantly lower low-dose volume (V{sub 5}) for the lung (p = 0.005). For auto-planning, the V{sub 5} of the lung was significantly associated with the relative volume index (the volume ratio of PTV to the lung), and the correlation coefficient (R) and p-value were 0.994 and 0.000. Pinnacle auto-planning achieved superior target conformity and homogeneity and similar target coverage compared with historical manual planning. Most of organs at risk (OARs) sparing was significantly improved by auto-planning except for the V{sub 5} of the lung, and the low dose distribution was highly associated with PTV volume and lung volume in auto-planning.

61 RADIATION PROTECTION AND DOSIMETRY↗