Search NASA⌕ Search

SEARCH · Search NASA

Results for “HUMIDITY MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Characterization of Precipitation-Induced Radon Progeny Deposition Events Using a City-Scale Sensor Network

Networks of radiation detectors provide a platform for real-time radioactive source detection and identification in urban environments. Detection algorithms in these systems must adapt to naturally-occurring changes in background, which requires well-characterized relationships between precipitation events and their corresponding radiological signature. Here, we present a quantitative and qualitative description of rain-induced radon progeny deposition events occurring in Chicago from September 2023 to February 2024. We measure ambient gamma radiation levels, precipitation rate, temperature, pressure, and relative humidity in a network of sensor nodes. For each identified precipitation period, we decompose spectra into static- and radon-associated components as defined by a non-negative matrix factorization (NMF) algorithm. We find a consistent power-law relationship between a precipitation-dependent peak of the radon progeny proxy (RPP) and the peak strength of the radon-associated NMF component for most precipitation events. We conduct a case study of a rainfall period with abnormally high levels of implied radon progeny concentration and describe its temporal and spatial evolution. We hypothesize that this phenomenon is due to the air mass path that intersects a uranium-rich region of Wyoming. Finally, we cluster precipitation events into three distinct categories. One category roughly corresponds to events with deep low-pressure systems and high relative radon concentration, while another is characteristic of light stratiform rain with slightly higher temperatures and intermediate relative radon concentration. The third category appears to contain weak-gradient or lake breeze convection showers with intermittent precipitation and low relative radon concentration. These findings suggest that radiological anomaly detection could be improved by training unique background models corresponding to each category of meteorological event.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electrochemical Measurement of Water Transport Numbers in Anion-Exchange Membranes

Anion-exchange membranes (AEMs) are a possible replacement for perfluorosulfonic-acid membranes in energy-conversion devices, primarily due to the hydroxide mobile ion allowing the devices to operate in alkaline conditions with less expensive electrocatalysts. However, the transport properties of AEMs remain understudied, especially electro-osmosis. In this work, an electrochemical technique, where the open-circuit voltage is measured between two ends of a membrane maintained at different relative humidities, is used to determine the water transport number of various ionomers, including Versogen and Sustainion AEMs and Nafion cation-exchange membrane (CEM), as a function of water content and temperature. In addition, the CEMs and AEMs are examined in differing single-ion forms, specifically proton and sodium (CEM) and hydroxide and carbonate (AEM). Carbonate-form AEMs have the highest transport number (∼11), followed by sodium-form CEMs (∼8), hydroxide-form AEMs (∼6), and proton-form CEMs (∼3). Finally, a multicomponent transport model based on the Stefan-Maxwell-Onsager framework of binary interactions is used to develop a link between water transport number and water-transport properties, extracting a range for the unmeasured membrane water permeability of Versogen as a function of water content.

30 DIRECT ENERGY CONVERSION↗

More science with less: evaluation of a 3D-printed weather station

Abstract. A weather station built using 3D-printed parts and low-cost sensors, based on plans and guidance provided by the University Corporation for Atmospheric Research 3D-Printed Automatic Weather Station Initiative, was deployed alongside an Oklahoma Mesonet station to compare its performance against standard commercial sensors and determine the longevity and durability of the system. Temperature, relative humidity, atmospheric pressure, wind speed and direction, solar radiation, and precipitation measurements were collected over an 8-month field deployment in Norman, Oklahoma. Measurements were comparable to the commercial sensors except for wind direction, which proved to be problematic. Longevity and durability of the system varied, as some sensors and 3D-printed components failed during the deployment. Overall, results show that these low-cost sensors are comparable to the more expensive commercial counterparts and could serve as viable alternatives for researchers and educators with limited resources for short-term deployments. Long-term deployments are feasible with proper maintenance and regular replacement of sensors and 3D-printed components.

54 ENVIRONMENTAL SCIENCES↗

CRGTBSO3 TBS Ozone Data

The Tethered Balloon System (TBS) operated for two weeks during a summer IOP of the CoURAGE campaign. This dataset includes data collected from an En-Sci electrochemical cell (ECC) ozonesonde on the TBS. The ozonesonde was connected to an iMet-4RSB radiosonde, and the overall data collected included ozone, relative humidity, temperature, and altitude. The data from the iMet is the same as that found in the TBSMERGED data product. The TBS also had another instrument (iMet XQ2) that collected meteorological data, which may have more accurate relative humidity (RH) data. This ozonesonde data set is intended to complement the TBSMERGED data product, the CRGTBSO3 surface ozone measurements, and the CoURAGE SWARM ozone lidar (TOLNet) measurements from other locations.

Atmospheric relative humidity↗

Leaf gas exchange and fitted parameters, two sites in Panama, 2022

Photosynthetic CO2 response curves (ACi curves), light response curves (AQ curves), dark adapted dark respiration, conductance curves, and survey measurements for leaves measured in the Parque Natural Metropolitano (PNM) and Gamboa, Panama, from January to April 2022 are presented. Measurements were made on leaves from 46 different tree, shrub and liana species, from sunlit canopy and understory locations. Leaf area index from 8 vertical profiles at PNM are also included. The aim of this measurement campaign was three-fold: (i) to improve our understanding of the vertical variation in leaf-level water use efficiency; (ii) to develop an understanding of the sensitivity of stomata to changes in environmental conditions, especially light, humidity, and temperature; (iii) to improve models which can predict leaf traits from leaf contact spectral measurements. All the gas exchange data and metadata are presented in .csv files and complete instrument output are included in .zip folders. Data and metadata meet the ESS-DIVE leaf-level gas exchange reporting format requirements. The protocol details are provided as pdf documents. In addition to gas exchange data reported here these samples were also used for measurement of leaf optical properties, carbon and nitrogen content, and leaf mass per unit leaf area (LMA). These data can be cross linked using the unique sample ID and are provided in separate data packages.

54 ENVIRONMENTAL SCIENCES↗

The role of soil redox conditions in microbial phosphorus cycling in humid tropical forests

Humid tropical forests are among the most productive ecosystems globally, yet they often occur on soils with high phosphorus (P) sorption capacity, lowering P availability to biota. Short-term anoxic events are thought to release sorbed P and enhance its acquisition by soil microbes. However, the actual effects of anoxic conditions on microbial P acquisition in humid tropical forest soils are surprisingly poorly studied. We used laboratory incubations of bulk soils, NanoSIMS analysis of single microbial cells, and landscape-scale measurements in the Luquillo Experimental Forest (LEF), Puerto Rico to test the hypothesis that anoxic conditions increase microbial P acquisition in humid tropical forests. In laboratory and field experiments, we found that microbial P uptake generally decreased under anoxic conditions, leading to high microbial carbon (C) to P ratios in anoxic soils. The decreased P acquisition under anoxic conditions was correlated with lower microbial C use efficiency (CUE), an index of microbial energy transfer in ecosystems. Phosphorus amendments to anoxic soils led to increased microbial P uptake and higher CUE suggesting that microbes were less able to access and utilize P under natural low redox conditions. Under oxic conditions, microbial C:P ratios and CUE did not respond to changes in substrate stoichiometry. These results challenge the existing paradigm by showing that anoxic conditions can decrease microbial P uptake and ultimately constrain microbial CUE. Finally, our findings indicate that soil redox conditions tightly couple soil P and C cycles and advance our understanding of controls on P cycling in humid tropical forest ecosystems.

59 BASIC BIOLOGICAL SCIENCES↗

Humidity-Dependent Electrostatic Charge Decay on Dielectric Surface in Enclosed Volumes

Electrostatic surface charge decay is investigated to determine loss mechanisms, the effect of humidity, enclosure size, and material. This work focuses on charging dielectric and metal surfaces close to the electrical breakdown threshold in atmospheric air under humid and dry conditions. After initial charging to a maximum potential of roughly 30 kV, the associated surface charge is allowed to decay because of recombining with ions from the natural background, resulting in decay times ranging from minutes to hours to days. Spheres with a radius of 50 mm consisting of varying materials (PTFE and metal as referenced later) are charged and tested at relative humidity levels, RH, of 10%, 35%, and 64%. It was found that the ion-ion pair production rate and the enclosure size affected the measured charge decay rate. The impact of air convection on charge decay in the open air (no enclosure) is discussed. The humidity increased the rate of charge decay on the metal and dielectric spheres. For example, in the first 25 minutes after charging, the total charge on the PTFE sphere decreased to 66%or 50% from its initial value in the 10% and 35% RH tests, respectively. An equivalent generation rate is found for the ions in the enclosure, with 10 and 24 ion pairs cm −3 s −1 being generated at a 5% and 49% relative humidity, respectively.

42 ENGINEERING↗

Nephelometer Instrument Handbook

The Integrating Nephelometer (Figure 1) is an instrument that measures aerosol light scattering. It measures aerosol optical scattering properties by detecting (with a wide angular integration – from 7 to 170°) the light scattered by the aerosol and subtracting the light scattered by the carrier gas, the instrument walls and the background noise in the detector (zeroing). Zeroing is typically performed for 5 minutes every day at midnight UTC. The scattered light is split into red (700 nm), green (550 nm), and blue (450 nm) wavelengths and captured by three photomultiplier tubes. The instrument can measure total scatter as well as backscatter only (from 90 to 170°) (Heintzenberg and Charlson 1996; Anderson et al. 1996; Anderson and Ogren 1998; TSI 3563 2015) At ARM (Atmospheric Radiation Measurement), two identical Nephelometers are usually run in series with a sample relative humidity (RH) conditioner between them. This is possible because Nephelometer sampling is non-destructive and the sample can be passed on to another instrument. The sample RH conditioner scans through multiple RH values in cycles, treating the sample. This kind of setup allows to study how aerosol particles’ light scattering properties are affected by humidification (Anderson et al. 1996). For historical reasons, the two Nephelometers in this setup are labeled “wet” and “dry”, with the “dry” Nephelometer usually being the one before the conditioner and sampling ambient air (the names are switched for the MAOS measurement site due to the high RH of the ambient air).

47 OTHER INSTRUMENTATION↗

Long-term ultrasonic monitoring of concrete affected by alkali-silica reaction

This article presents continuous monitoring results of alkali-silica reaction (ASR) development in concrete specimens for over 400 days using ultrasonic testing and expansion measurements. Eight concrete specimens with nonreactive aggregate (Control), reactive coarse aggregate, and reactive fine aggregates were cast with two reinforced confinement conditions. The specimens were conditioned in an environmental chamber with high temperature and humidity (38°C and 90% relative humidity) to accelerate the ASR development. A multichannel ultrasonic monitoring system was developed to collect ultrasonic signals automatically, and the expansions in three directions were measured periodically. Results showed that the relative velocity change could detect the ASR initiation in all reactive specimens and show a correlation with expansion in the early stage. However, these correlations are inconsistent for different ASR specimens, and the velocity change becomes less sensitive to ASR damage in the late stage (after 300 days). Irrecoverable velocity drop was observed during every chamber shutdown period, especially in specimens with higher levels of ASR damage. This phenomenon suggests that the nonlinear ultrasonic response caused by the ambient temperature variation may indicate the ASR damage.

Engineering↗

Optical Particle Measurements during EPCAPE Field Campaign Report

This campaign requested the deployment of the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) User Facility optical particle counter (OPC) at the first ARM Mobile Facility (AMF1) located at the Scripps Pier in La Jolla, California during the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE). The addition of the OPC was requested for two reasons. (1) Close the gap between the scanning mobility particle sizer (SMPS) and aerodynamic particle sizer (APS) size distribution from the Aerosol Observing System (AOS) measurements. (2) Principal investigator Petters has been working with Tracking Aerosol Convection Interaction Experiment (TRACER) data to compute particle fluxes from Doppler lidar (Petters et al. 2024). Briefly, backscatter flux is obtained using the eddy covariance technique using the Doppler vertical velocity and attenuated backscatter. Building upon prior studies, we were able to relate backscatter to particle number concentration by calibrating the lidar retrievals against optical particle counter-measured ground-based aerosol size distribution and radiosonde-interpolated relative humidity at lidar sample height. Performing similar analysis was of interest to EPCAPE to better understand the emissions and vertical transport of large particles into the overlying stratus clouds. However, as stated above, this analysis requires an optical size distribution that covers the 0.3-30-μm-diameter size range. The OPC was deployed between 2023-04-14 and 2024-02-14. The deployment, data quality analysis, and data archiving was handled by the DOE ARM instrument mentor team without additional involvement by the principal investigator. Data quality was marked as “routine” for the majority of the campaign.

54 ENVIRONMENTAL SCIENCES↗

Predictions of the glass transition temperature and viscosity of organic aerosols from volatility distributions

Abstract. Volatility and viscosity are important properties of organic aerosols (OA), affecting aerosol processes such as formation, evolution, and partitioning of OA. Volatility distributions of ambient OA particles have often been measured, while viscosity measurements are scarce. We have previously developed a method to estimate the glass transition temperature (Tg) of an organic compound containing carbon, hydrogen, and oxygen. Based on analysis of over 2400 organic compounds including oxygenated organic compounds, as well as nitrogen- and sulfur-containing organic compounds, we extend this method to include nitrogen- and sulfur-containing compounds based on elemental composition. In addition, parameterizations are developed to predict Tg as a function of volatility and the atomic oxygen-to-carbon ratio based on a negative correlation between Tg and volatility. This prediction method of Tg is applied to ambient observations of volatility distributions at 11 field sites. The predicted Tg values of OA under dry conditions vary mainly from 290 to 339 K and the predicted viscosities are consistent with the results of ambient particle-phase-state measurements in the southeastern US and the Amazonian rain forest. Reducing the uncertainties in measured volatility distributions would improve predictions of viscosity, especially at low relative humidity. We also predict the Tg of OA components identified via positive matrix factorization of aerosol mass spectrometer (AMS) data. The predicted viscosity of oxidized OA is consistent with previously reported viscosity of secondary organic aerosols (SOA) derived from α-pinene, toluene, isoprene epoxydiol (IEPOX), and diesel fuel. Comparison of the predicted viscosity based on the observed volatility distributions with the viscosity simulated by a chemical transport model implies that missing low volatility compounds in a global model can lead to underestimation of OA viscosity at some sites. The relation between volatility and viscosity can be applied in the molecular corridor or volatility basis set approaches to improve OA simulations in chemical transport models by consideration of effects of particle viscosity in OA formation and evolution.

54 ENVIRONMENTAL SCIENCES↗

Analysis of Long-Term Quality Control Data for a 137 Cs Dosimetry Calibration Source

Strict quality assurance programs are required for many radiological applications, but these seldom exist for verifying dosimetry calibration sources. After initial characterization of a dosimetry calibration facility, quality control procedures are recommended to ensure the early detection of any changes or malfunctions. These also result in refined knowledge about average dose rate and experimental variations in dose delivery. This paper describes the implementation of a phase I quality control protocol for a 137 Cs dosimetry calibration source and includes an analysis of the resulting data collected over a 24-mo period. During this time, substantial data was collected to establish trial control limits. Air kerma rate measurements were obtained using an ion chamber and were adjusted for decay, corrected for ambient temperature, pressure and humidity, and then analyzed using quality control charts. Three variations of rational subgrouping methods were used in order to find assignable causes of error, and Nelson's Rules were followed to detect any non-random statistical variations. Measurements were subgrouped according to same-day measurements in order to detect positional errors as well as atmospheric correction errors. Additionally, measurements were subgrouped according to analogous experimental setups in order to detect failure in equipment or incorrect settings. Both were analyzed using the X-bar and R chart method. Similarly, individuals and moving ranges charts were used to carefully examine each position in order to observe any situational errors that may occur which include timing, positional, or interference errors. Each method was successful in identifying unique out-of-control data points that occurred during the phase I application of forming control limits. Furthermore, over the 24-mo period, enough data points were deemed in-control to establish reliable trial limits. Future experiments will include the phase II application of gaining more reliable measurements in order to fine-tune the limits, as well as performing a designed experiment, where variables are purposefully changed in order to test the variation of the data.

61 RADIATION PROTECTION AND DOSIMETRY↗

CROCUS Weather Data at Northeastern Illinois University Rooftop

This dataset is from the Department of Energy Office of Science funded project, Community Research on Urban and Climate Science (CROCUS) (https://crocus-urban.org/). Vaisala WXT sensor is an all-in-one weather instrument that provides 6 of the most important weather parameters: barometric pressure, temperature, relative humidity, rainfall, wind speed and direction. Temperature, pressure, relative humidity, and rainfall are sampled at 1 second frequency, while wind speed/direction is measured at ten per second (10Hz) frequency. These measurements are useful for looking at characterizing local weather, identifying unique weather events, and studying local turbulence, especially given the high temporal resolution of the wind measurements.Datasets are stored in the netCDF data format, and we we encourage users to make use the associated toolkits available from Unidata (https://www.unidata.ucar.edu/software/netcdf/), Project Pythia (https://foundations.projectpythia.org/core/data-formats/netcdf-cf.html), and our “Instrument Cookbooks” (https://crocus-urban.github.io/instrument-cookbooks) for more information on how to process the metadata-rich datasets.

54 ENVIRONMENTAL SCIENCES↗

Influence of Water Sorption on Ionic Conductivity in Polyether Electrolytes at Low Hydration

Ion-containing polymers are subject to a wide range of hydration conditions across electrochemical and water treatment applications. Significant work on dry polymer electrolytes for batteries and highly swollen membranes for water purification has informed our understanding of ion transport under extreme conditions. However, knowledge of intermediate conditions (i.e., low hydration) is essential to emerging applications (e.g., electrolyzers, fuel cells, and lithium extraction). Ion transport under low levels of hydration is distinct from the extreme conditions typically investigated, and the relevant physics cannot be extrapolated from existing knowledge, stifling materials design. In this study, we conducted ion transport measurements in LiTFSI-doped polyethers that were systematically hydrated from dry conditions. A semiautomated apparatus that performs parallel measurements of water uptake and ionic conductivity in thin-film polymers under controlled humidity was developed. For the materials and swelling range considered in this study (i.e., <0.07 g water/g dry polymer electrolyte), ionic conductivity depends nonlinearly on water uptake, with the initial sorbed water weakly affecting conductivity. With additional increases in swelling, more significant increases in conductivity were observed. Remarkably, changes in conductivity induced by water sorption were correlated with the number of water molecules per lithium ion, with the normalized molar conductivity of different samples effectively collapsing onto one another until this unit of hydration exceeded the solvation number of lithium ions under aqueous conditions. Furthermore, these results provide important knowledge regarding the effects of trace water contamination on conductivity measurements in polymer electrolytes and demonstrate that the lithium-ion solvation number marks a key transition point regarding the influence of water on ion transport in ion-containing polymers.

36 MATERIALS SCIENCE↗