Search NASA⌕ Search

SEARCH · Search NASA

Results for “HVAC efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Experimental study of a thermal energy storage-integrated heat pump system for load shifting in space cooling and heating

This study experimentally investigates an all-season thermal energy storage-integrated heat pump (TES-HP) system developed to enhance building energy efficiency and support grid-interactive operation through load shifting in both cooling and heating. A 4-ton commercial rooftop air-source heat pump was modified by integrating a hydronic thermal energy storage (TES) unit containing a phase change material (PCM) with a melting temperature of 22.0 °C. The system employs two reversing valves and three electronic expansion valves to enable six operating modes, including normal, TES charging, and TES discharging in both cooling and heating seasons. A subcooling-controlled electronic expansion valve was implemented to mitigate refrigerant maldistribution caused by unequal internal volumes among the heat exchangers. Compared with a baseline heat pump, the TES-HP reduced power consumption by 30–50% during cooling at an ambient temperature of 40.6 °C, and by up to 60% during heating at −15.0 °C, while maintaining high performance under cold-climate conditions. Additionaly to experimental evaluation, a simplified annualized on-peak analysis was conducted to compare the TES-HP with the baseline system, indicating an on-peak electricity reduction of approximately 876 kWhₑ per unit per year and associated on-peak cost savings under time-of-use pricing. These results demonstrate that the TES-HP effectively decouples HP operation from adverse ambient conditions, improving flexibility, resilience, and energy efficiency. This work advances prior research by experimentally proving the integration of PCM-based TES for a year-round, load-flexible HVAC operation.

42 ENGINEERING↗

What's in a Name? Developing a Standardized Taxonomy for HVAC System Faults

Faults occurring in heating, ventilation and air-conditioning (HVAC) systems have significantly negative impacts on building energy consumption, occupant comfort, and indoor air quality. In the past thirty years, extensive research has been conducted on fault detection and diagnostics (FDD) methods, and there are now dozens of commercially available FDD software tools. Growing adoption of FDD tools has the potential to generate a massive and useful data set on fault characteristics. However, the lack of a unifying taxonomy is a significant barrier to efficient analysis and evaluation of FDD outputs. Therefore, there is a strong need to develop a robust taxonomy which can better represent and interpret FDD output data. This paper documents the development of a unifying taxonomy for HVAC system faults in commercial buildings, with initial focus on air handling units, variable air volume terminal units, and roof top unit systems. The developed fault taxonomy employs both a physical hierarchy of HVAC equipment and a cause-effect relationship model as tools to better understand and support root cause analysis for HVAC faults. A variable air volume terminal unit is used as an example to demonstrate the application of the developed fault taxonomy. The taxonomy has short-term application in a major U.S. study on fault prevalence, and promises longer term benefits to FDD software developers and building operators by creating a foundation for improved approaches to identifying and resolving HVAC faults.

Chen, Yimin↗

City-level impacts of building tune-ups: Findings from Seattle's building tune-ups program

Many U.S. cities are implementing policies to reduce greenhouse gas (GHG) emissions of their buildings. These range from building energy benchmarking and disclosure to building performance standards (BPS) that require buildings to meet specific targets of energy use or emissions. The City of Seattle adopted a climate action plan in 2013 that set a goal of zero net GHG emissions in the road transportation, buildings, and waste sectors by 2050, with a number of near and long term actions. Seattle implemented mandatory building tune-ups in 2016, applying to commercial buildings larger than 50,000 sqft. Building tune-ups1 involve assessment and implementation of operational and maintenance (O + M) improvements to achieve energy and water efficiency, such as changes to thermostat set points or adjusting lighting or irrigation schedules. Seattle's tune-ups program covered 27 such improvements in HVAC, lighting, domestic hot water, and envelope systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

VOLTTRON/econ-dispatch

Work space for in development Economic Dispatch Application. Multi-purpose open-source control algorithms that will ensure real-time optimal operation, increase electric grid reliability, and lead to the goal of clean, efficient, reliable and affordable next generation building-integrated combine cooling, heating and power (CHP) system.The CHP system could include conventional heating, ventilation, air conditioning (HVAC) systems, distributed generation (DG), local storage (both thermal and electric) and local solar photovoltaic (PV) systems.

Katipamula, Srinivas↗

The relative importance of building design parameters in reducing energy use and sensible heat release from buildings in light of forecasted future weather data and building coverage ratio

Buildings typically have a 60-to-75-year lifespan before they require significant maintenance or modifications. However, most builders evaluate the performance of their new buildings using whole-building energy simulation tools based on the current typical meteorological year (TMY) file or actual meteorological year. The energy use consumption and sensible heat release pattern observed from buildings could potentially change based on shifting global climates. Therefore, the recommended energy-efficiency design parameters might also change during these periods. In this study, we evaluate the role of different building design parameters, such as material reflectivity, HVAC COP, and insulation values, on building energy usage and sensible heat release from buildings with different building coverage ratios (BCR), based on the current and future weather file TMY (fTMY) for the middle of the century (2040–2060). The role of sensible heat release from buildings is not accounted for accurately while estimating building energy usage in most whole-building energy simulations. The study conducts a series of whole-building energy simulation analyses using EnergyPlus to evaluate the role of different design parameters based on TMY and fTMY weather conditions. The analysis is conducted for two hot desert climatic cities: Phoenix (USA) and Abu Dhabi (UAE). The results show that, for the base case in a future climate, the sensible heat release is reduced by an average of 30% due to the reduced delta T between the surface and ambient air. Further, the results show an increase in total energy consumption by 5% annually. The results also show that, for buildings with traditional coatings, shorter buildings release more heat than taller buildings. On the other hand, for buildings with reflective paints, shorter buildings release less heat than taller buildings. The findings from this study can be used by policymakers, utility companies, and builders to better understand the relative role of different building design parameters while constructing new and retrofitting existing buildings.

Alhazmi, Mansour [King Fahd University of Petroleu↗

High performance heat exchangers for next generation hybrid cooler (CRADA NFE-19-07891 Final Report)

The evaporative cooling process has been successfully deployed in multiple energy conversion processes such as power generation, process cooling, heating, ventilation & cooling (HVAC), and commercial and industrial refrigeration. The heat exchanger is a very common yet extremely critical component of such systems. The device is important since the performance of the overall cooling system heavily relies on the thermal-hydraulic efficiency of the heat exchanger. The possible wet operation as evaporative cooling heat exchanger complicates the issue. Indeed, based on the hybrid nature of operation (fully dry, partially wet, fully wet) the efficiency can vary significantly and can cause performance variation for the whole system. Understanding the importance of the issue, Oak Ridge National Laboratory (Contractor) and Baltimore Aircoil Company (Participant) propose an activity focused on the analysis of the existing heat exchanger technology used in air and evaporative cooling processes and design, development and demonstration of a novel heat exchanger design based on porous materials. The potential candidates include metallic wire meshes and metal foams carefully designed for the proposed application. Prior research has indicated that these materials have great potential for deployment in thermal systems, particularly heat sinks and heat exchangers. It is expected that the successful completion of the project will lead to novel heat exchanger technology for hybrid systems (capable of dry and wet operation) by exploring newly emerging materials and their potential for heat transfer application. The overall goal is to develop a next generation heat exchanger technology which can be deployed in evaporative cooling systems. The impact of the such development is significant since, it will not only make the overall system highly efficient but will also, reduce the total refrigerant charge in the heat exchanger, a critical aspect for the deployment of refrigerants with lower Global Warming Potential (GWP).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sensor impacts on building and HVAC controls: A critical review for building energy performance

Building operations rely heavily on control systems and sensors. This paper provides a sophisticated literature review on sensor systems in building/HVAC systems, particularly in the context of controls, and their impacts on energy efficiency and thermal comfort. This study aims to understand the previous and current research and identify future research opportunities on this subject. The reviewed sensor systems were used for heuristic rule-based controls, local controls, and advanced optimal controls for existing and emerging technologies. Five major aspects of sensors are reviewed here: control loops for sensors, sensor types, sensor locations, sensor data, and a sensor impact evaluation framework. To augment the literature review, comprehensive standardized interviews were also conducted with relevant industry experts and practitioners. These interviews were designed and performed to (1) identify significant factors for selecting sensor sets and current undergoing issues, (2) identify potential improvements in sensor configuration/deployment, and (3) integrate expert (e.g., researcher, building operation practitioner) knowledge and experiences to develop structured use-case scenarios. Researchers collected and analyzed 31 interview responses for this paper.

Building control↗

Gnu-RL: A Precocial Reinforcement Learning Solution for Building HVAC Control Using a Differentiable MPC Policy

Reinforcement learning (RL) was first demonstrated to be a feasible approach to controlling heating, ventilation, and air conditioning (HVAC) systems more than a decade ago. However, there has been limited progress towards a practical and scalable RL solution for HVAC control. While one can train an RL agent in simulation, it is not cost-effective to create a model for each thermal zone or building. Likewise, existing RL agents generally take a long time to learn and are opaque to expert interrogation, making them unattractive for real-world deployment. To tackle these challenges, we propose Gnu-RL: a novel approach that enables practical deployment of RL for HVAC control and re- quires no prior information other than historical data from exist- ing HVAC controllers. To achieve this, Gnu-RL adopts a recently- developed Differentiable Model Predictive Control (MPC) policy, which encodes domain knowledge on planning and system dynam- ics, making it both sample-efficient and interpretable. Prior to any interaction with the environment, a Gnu-RL agent is pre-trained on historical data using imitation learning, which enables it to match the behavior of the existing controller. Once it is put in charge of controlling the environment, the agent continues to improve its policy end-to-end, using a policy gradient algorithm. We evaluate Gnu-RL on both an EnergyPlus model and a real- world testbed. In both experiments, our agents were directly de- ployed in the environment after offline pre-training on expert demonstration. In the simulation experiment, our approach saved 6.6% energy compared to the best published RL result for the same environment, while maintaining a higher level of occupant comfort. Next, Gnu-RL was deployed to control the HVAC of a real-world conference room for a three-week period. Our results show that Gnu-RL saved 16.7% of cooling demand compared to the existing controller and tracked temperature set-point better.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development and Evaluation of Occupancy-Aware Model Predictive Control for Residential Building Energy Efficiency and Occupant Comfort

The residential sector accounts for 25% of global primary energy consumption. Two methods have previously been proposed to reduce residential energy use associated with the provision of occupant thermal comfort: 1. Occupancy-based HVAC control, operating systems only during confirmed occupancy, and 2. model predictive control (MPC), harnessing a mathematical model and forecasts to find optimal operating strategies. Previous studies estimate the average energy savings of the two methods individually in the range of 21% and 16%, respectively. The research presented herein was carried out to evaluate the energy savings potential in residential buildings by combining both approaches across different climates, house vintages, and occupancy patterns. Occupancy and eight different physical modalities (e.g. CO2 and VOC) data were collected from five homes for time periods of 4–9 weeks. Collected data sets were used to train occupancy prediction models suggested by an extensive literature survey of occupancy model types. The trained prediction models were combined with MPC and detailed EnergyPlus building simulation models to evaluate residential building performance in terms of annual energy savings and thermal comfort, along with discomfort exceedance metrics. Multiple home types and regions were analyzed to understand regional and climate-dependent potential. Based on actual field data, the occupancy models had a prediction inaccuracy between 8% and 35% across the investigated homes. Average occupancy for the collected data ranged from 56% to 86%, a typical range reported in the literature. Building simulations were conducted for three control scenarios: conventional thermostatic control, occupancy-based, and occupancy-based MPC. The results indicate that all advanced strategies improve upon the conventional control, with some scenarios cutting energy use in half with only occasional incurrence of discomfort. The findings indicate that occupancy-aware model predictive residential building control has the potential to drastically reduce energy use and associated emissions while maintaining occupant comfort for both new and existing buildings.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Seminar 44, Innovative and New Ideas: BAS Best Practices for O&M Success Coaching Operators for Effective Use of Data

Regardless of a building’s inherent energy efficiency, changes in building operator behavior reduces building energy consumption by 14% on average. Giving operators readily available and easily digestible data regarding the performance of their HVAC systems increases the likelihood of energy saving actions. Many Building Automations Systems do not excel at creating user-friendly time series trend charts. This presentation presents examples of a solution to this issue developed under an award by the Department of Energy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimizing Ventilation Using Low-Cost Sensors to Improve Health, Safety, and Energy Efficiency

Air is the primary carrier of hazards within a space, whether it be hazardous bi-products of research activities or airborne pathogens. As a result, building ventilation is the primary defense against unseen airborne hazards. Critical laboratory facilities already demand the need for effective mitigation of exposure to research-related, airborne hazards, providing a proving ground for effective ventilation strategies that optimize safety of occupants and reduce energy use. The heart of smart laboratory building operation is dynamic, analytics-based ventilation, which requires an intimate knowledge of building environmental conditions achieved through contaminant-detection systems. Unfortunately, currently available contaminant-detection solutions are expensive, elaborate systems that raise barriers for building managers on a limited budget. Through the successful deployment of a novel low-cost, modular sensor technology, we have developed a demand-control ventilation protocol effective in improving safety and reducing energy in the critical laboratory environment. In this session, we will highlight best practices and lessons learned through this deployment that can be applied beyond laboratories without breaking the bank. This paper describes a low-cost solution for providing a safe, healthy building environment and reducing energy use through effective, efficient ventilation.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Efficiency and Capacity Performance of a Stirling-Cycle Water-to-Water Heat Pump

The performance of a 10 kW (2.8 ton) heat pump has been modeled in preparation for evaluation in a controlled-atmosphere psychrometric facility. The heat pump uses an electrically driven Stirling engine with nitrogen as a working fluid. The appropriate standards for testing are ANSI/AHRI/ASHRAE ISO Standard 13256-2:1998 (RA 2012), Water-Source Heat Pumps—Testing and Rating for Performance—Part 2: Water-to-Water and Brine-to-Water Heat Pumps. The heating and cooling efficiency and capacity of the device has been modeled at different hot and cold sink temperatures spanning a wide range of possible operating conditions. The heat pump was designed for a seasonal efficiency energy ratio (SEER) of 22. The high efficiency of this product coupled with the use of nitrogen as a working fluid makes it an important tool for the decarbonization of residential, commercial, and industrial HVAC&R applications.

Kowalski, Steve↗

Cabin Thermal Management Analysis for SuperTruck II Next-Generation Hybrid Electric Truck Design

In this article, we present a multistage, coupled thermal management simulation approach, informed by physical testing where available, to aid design decisions for PACCAR's SuperTruck II hybrid truck cabin concept. Focus areas include cabin insulation, battery sizing, and sleeper curtain position, as well as heating, ventilating, and air-conditioning (HVAC) component and accessory configurations, to maintain or improve thermal comfort while saving energy. The authors analyzed weather data and determined the national vehicle miles traveled weighted temperature and solar conditions for long-haul trucks. Example weather day profiles were selected to approximate the 5th and 95th percentile weighted conditions. A daylong drive cycle was developed to impose appropriate external wind conditions during rest and driving periods. Using the National Renewable Energy Laboratory's vehicle HVAC modeling and simulation tool VTCab, HVAC load design trade-off studies for the new truck geometry concept were completed. Parameters analyzed included effects of paint color, insulation, glass transmissivity, and curtain location. Simulation results helped with early design material selections for efficient cabin climate control. A detailed three-dimensional computer-aided engineering (CAE), computational fluid dynamics (CFD), radiation, and human physiology co-simulation, referred to in this article as CAE Thermal-CFD, was used to evaluate thermal comfort and energy impacts of diffuser configurations and air supply settings in driving and hoteling modes. Analysis revealed that it is more difficult to heat the cabin in hoteling mode during the winter than to cool the space in the summer. This seasonal load profile drives the requirement of additional energy storage for heating comfort. To determine the battery capacity requirement, multiday HVAC operation drive cycle simulations were then completed, showing that a 15-kWh battery would be required for HVAC operation during hoteling. Results helped reduce cabin thermal loads, determine component sizing requirements, and improve occupant comfort to save fuel and contribute to the economic viability of the hybrid system.

33 ADVANCED PROPULSION SYSTEMS↗

Integrated Solutions for Optimized Performance (ISOP) Final Technical Report

The goal of this project was to demonstrate technical feasibility of an integrated approach for deep energy retrofits by packaging innovative technologies with smart communicating controls that represent the next generation of energy efficiency. The integrated solutions for optimized performance (ISOP) package integrates (i) advanced lighting and plug load controls; (ii) intelligent daylight harvesting through automated self-powered shades and window films; (iii) advanced HVAC controls sequences (ASHRAE Guideline (GDL) 36); and (iv) fault detection and diagnosis (FDD) and continuous commissioning (CCx) using advanced analytics. These technologies address energy use across multiple building end uses that represent more than 60% of the energy consumption in all commercial buildings. The project was structured to be implemented over three budget periods: Budget Period 1 scope included site selection, project design, site-specific customization of technology packages, procurement of technologies, initiation of installation of technologies, the development of a measurement and verification plan and collection of pre-retrofit data collection. The first year go/no-go decision was based on securing host sites representing 250,000 sq. ft. of occupied operational spaces, savings analysis, technology procurement and initiation of installation. Budget Period 2 planned to complete technology installations and initiate data collection of post-retrofit performance data. The second year go/no-go was to be the completion of technology installations and commissioning, metering and data collecting to support the requirements laid out in site specific M&V plans. Budget Period 3 planned to collect and analyze post-retrofit performance data and provide data and reporting to support energy efficiency rebate programs. After the team completed activities planned for Budget Period 1, the team reached a Go/No-Go Decision Point. At that point, TRC recommended that DOE discontinue the project without prejudice due to challenges with securing demonstration sites to meet the full 250,000 sf of occupied operational spaces and DOE concurred. In Budget Period 1, the TRC team developed criteria to recruit and evaluate potential demonstration host sites. TRC worked with Princeton University, the project demonstration partner, to identify buildings on their campus as potential candidates for the demonstration. Following the selection of demonstration sites, the TRC team customized energy technology packages according to the needs and characteristics of each site. TRC defined technology specifications, identified vendors, and conducted analysis to estimate energy and cost savings potential. The project team then developed schedules for technology procurement processes and scheduled for installation at all selected demonstration sites. The project team worked with Princeton University and DOE to develop an approach to verify energy savings achieved through measurement and verification (M&V) 2.0 methods. Princeton University initiated open bids to procure the necessary materials and installation contractors. Bid results came back higher than estimates due to a couple of factors – lack of familiarity of the bidders with the proposed technologies and lack of local trained installers to execute the installation of these new measures. Due to the higher bids, projects no longer met the internal cost-effectiveness criteria used by Princeton to proceed with procurement of the full suite of technologies as proposed in ISOP. Princeton had already procured parts of the ISOP package as part of a campus-wide initiative for FDD and lighting retrofits, but with the higher costs for other ISOP components, Princeton could no longer commit to the full ISOP package on the selected sites. Based on this, the team reached the Go/No-Go decision point, where they decided not to proceed with the project. Princeton is separately installing portions of the ISOP package where they individually meet Princeton’s payback criteria but on a different schedule than would have been needed for the DOE ISOP project. The team has learned several lessons from project progress in the first budget period. The team will utilize these lessons in future projects, as should any team which proceeds with a project around the ISOP technology. The first lesson is that more information about the proposed sites is required earlier in the process (perhaps even at the proposal stage) in order to have a successful demonstration. Technical details not evident earlier in the process (such as the TLED limitations for ALCS) can derail project execution. The second lesson is that pricing of emerging technologies is highly variable due to lack of familiarity of local installers and distributor with the proposed technologies as well as alternate bids using products they were more familiar with, but that cost more than the ones proposed by TRC. Finally, the last major lesson is that the host site’s internal project criteria is of critical importance. Based on these higher installed costs and lack of an informed installer base for the products proposed for this project, the project does not meet Princeton’s simple payback goals of five years.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Reimagining Heating, Ventilation, and Air Conditioning for New Manufactured Homes

Manufactured homes represent one of the most affordable paths to home ownership for American households, but minimum-efficiency equipment and poor-quality home installation can lead to excess energy use and high operating costs. Slipstream, with partners from the Florida Solar Energy Center (FSEC), Northwest Energy Works, and Washington State University, identified and tested manufactured home HVAC innovations targeted for new construction offering the most promising mix of improved energy performance and likelihood of industry uptake.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Joining Study for Formed Plate Heat Exchangers (CRADA Final Report)

Plate heat exchangers (PHEs) have been used in numerous industrial applications, such as HVAC systems, power generation, transportation and manufacturing. The performance of plate heat exchangers is frequently undermined by corrosion, fouling, and scaling. These phenomena not only diminish heat transfer efficiency but also lead to increased operational costs, maintenance demands, and reduced equipment lifespan. In this project, the team addressed the widespread challenges of corrosion, fouling, and scaling, and explored alternative material solutions. While commonly used materials like stainless steel and titanium offer notable benefits, they can still experience corrosion under certain operating conditions. The advancement of new materials and surface engineering technologies, such as advanced coating, ceramics, composites materials, and high entropy alloys are promising for can help solve these issues, enable longer lifetime and high performance of plate heat exchangers.

99 GENERAL AND MISCELLANEOUS↗

Joining Study for Formed Plate Heat Exchangers (Final Report)

Plate heat exchangers (PHEs) have been used in numerous industrial applications, such as HVAC systems, power generation, transportation and manufacturing. The performance of plate heat exchangers is frequently undermined by corrosion, fouling, and scaling. These phenomena not only diminish heat transfer efficiency but also lead to increased operational costs, maintenance demands, and reduced equipment lifespan. In this project, the team addressed the widespread challenges of corrosion, fouling, and scaling, and explored alternative material solutions. While commonly used materials like stainless steel and titanium offer notable benefits, they can still experience corrosion under certain operating conditions. The advancement of new materials and surface engineering technologies, such as advanced coating, ceramics, composites materials, and high entropy alloys are promising for can help solve these issues, enable longer lifetime and high performance of plate heat exchangers.

36 MATERIALS SCIENCE↗

Pathways to commercial building plug and process load efficiency and control

Abstract To accomplish net-zero carbon emissions in the built environment by 2050, we must equitably decarbonize commercial buildings, including reducing plug and process loads (PPLs). PPLs are plug-in or hardwired electric and gas loads that are not associated with major building end uses like lighting and HVAC. Research shows PPL energy reduction strategies and control technologies have the potential to save energy. But even when implemented, these savings have rarely been achieved and there has not been widespread uptake in U.S. commercial buildings. We investigate why these technologies and strategies have not seen widespread adoption and identify behavior and technology pathways to increase PPL reduction in U.S. commercial buildings. We examined behaviors of commercial building stakeholders through 44 interviews and cross-referenced qualitative analysis findings with in-depth technical knowledge of existing PPL control technologies and reduction strategies. PPL control implementation must be paired with management strategies, such as occupant engagement and training, to achieve optimal savings, and best practices should be disseminated across the industry. We found that increasing access to cost and energy savings data will promote uptake of PPL control technologies and allow designers to better incorporate PPLs into building design. Improving access to funding for PPL energy efficiency projects and addressing the split-incentive problem will increase adoption of PPL efficiency and control. Code bodies should continue to include PPL monitoring and reduction measures in energy codes. Key building stakeholders, including cybersecurity and information technology teams, should be involved in PPL monitoring and reduction strategy processes for successful implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗