Search NASA⌕ Search

SEARCH · Search NASA

Results for “Heat Input”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Flat-plate /vapor-chamber/ heat pipes

This paper discusses the design, fabrication and testing of heat pipes constructed in the form of flat-plate panels. The test panels were constructed of copper with methyl alcohol as the working fluid. Capillary grooves etched on the internal surfaces provided evaporation and condensation heat-transfer coefficients on the order of 1600 Btu/hr-sq ft-deg F. Two panels were launched on board a sounding rocket; the payload reached an altitude of 140 miles, and zero gravity was achieved for almost six minutes. The panel with working fluid inside demonstrated a heat input flux of 2.5 watts/sq cm, with only a 3 to 5 C temperature difference throughout the entire panel.

Fleischman, G. L.↗

Development of a solar-powered residential air conditioner: Screening analysis

Screening analysis aimed at the definition of an optimum configuration of a Rankine cycle solar-powered air conditioner designed for residential application were conducted. Initial studies revealed that system performance and cost were extremely sensitive to condensing temperature and to the type of condenser used in the system. Consequently, the screening analyses were concerned with the generation of parametric design data for different condenser approaches; i. e., (1) an ambient air condenser, (2) a humidified ambient air condenser (3) an evaporative condenser, and (4) a water condenser (with a cooling tower). All systems feature a high performance turbocompressor and a single refrigerant (R-11) for the power and refrigeration loops. Data were obtained by computerized methods developed to permit system characterization over a broad range of operating and design conditions. The criteria used for comparison of the candidate system approaches were (1) overall system COP (refrigeration effect/solar heat input), (2) auxiliary electric power for fans and pumps, and (3) system installed cost or cost to the user.

Source record↗

Thermoelastic flutter models for elements of flexible satellites

Models of thermally induced flutter of the flexible elements of a satellite, such as beams, circular plates, and cylindrical shells, have been obtained. These models form the necessary blocks for analyzing the motion of satellites. The heat input is considered to be caused by solar radiation. The partial differential equations for all the elements of the satellite are linear in the space-dependent variables and nonlinear in the time-dependent variables. These equations are coupled through the motion of the center of mass of the satellite. Galerkin's method has been used to remove the space-dependence of these equations.

Huang, T. C.↗

X-rays from massive black holes

Tidal disruption of nondegenerate stars is shown to provide an important heat source for gas accreting onto massive black holes (about 10 to 100 million solar masses) in galactic nuclei. Turbulent dissipation by accreting gas streams can also be significant, and the heat input suffices to give rise to temperatures above about 1 billion K, resulting in an appreciable hard X-ray luminosity.

Meszaros, P.↗

Significance of large-scale circulation in magnetic storm characteristics with application to AE-C neutral composition data

Theoretical analysis of a magnetic storm in February 1974 leads to the following conclusions: (1) Wind-induced diffusion leads to depletion of O and He and enhancements of Ar at high latitudes. (2) The same process increases O and He and decreases Ar at low latitudes. (3) There is substantial agreement between theory and neutral composition data from the AE-C closed source neutral mass spectrometer; the low-latitude enhancements of O and He, in magnitude comparable to or even larger than those of N2 and Ar, are observed, which is characteristic for the circulation mechanism. (4) To achieve agreement with the composition measurements, a heat input rate of 1.7 ergs/sq cm s is required above 120 km. (5) Changes in the neutral composition associated with the annual variations have significant effects on the magnetic storm dynamics.

Mayr, H. G.↗

The economics of solar powered absorption cooling

Analytic procedure evaluates cost of combining absorption-cycle chiller with solar-energy system in residential or commercial application. Procedure assumes that solar-energy system already exists to heat building and that cooling system must be added. Decision is whether to cool building with conventional vapor-compression-cycle chiller or to use solar-energy system to provide heat input to absorption chiller.

Bartlett, J. C.↗

Purging of a tank-mounted multilayer insulation system by gas diffusion

The investigation was conducted on a multilayer insulation (MLI) system mounted on a spherical liquid hydrogen propellant tank. The MLI consisted of two blankets of insulation each containing 15 double-aluminized Mylar radiation shields separated by double silk net spacers. The gaseous nitrogen initially contained within the MLI system and vacuum chamber was purged with gaseous helium introduced both underneath the MLI and into the vacuum chamber. The MLI panels were assumed to be purged primarily by means of gas diffusion. Overall, test results indicated that nitrogen concentrations well below 1 percent could be achieved everywhere within the MLI system. Typical times to achieve 1 percent nitrogen concentration within the MLI panels ranged from 69 minutes at the top of the tank to 158 minutes at the bottom of the tank. Four space-hold thermal performance tests indicated no significant thermal degradation of the MLI system had occurred due to the purge tests conducted. The final measured heat input attributed to the MLI was 7.23 watts as compared to 7.18 watts for the initial baseline thermal performance test.

Sumner, I. E.↗

Accelerated life tests of specimen heat pipe from Communication Technology Satellite (CTS) project

A gas-loaded variable conductance heat pipe of stainless steel with methanol working fluid identical to one now on the CTS satellite was life tested in the laboratory at accelerated conditions for 14 200 hours, equivalent to about 70 000 hours at flight conditions. The noncondensible gas inventory increased about 20 percent over the original charge. The observed gas increase is estimated to increase operating temperature by about 2.2 C, insufficient to harm the electronic gear cooled by the heat pipes in the satellite. Tests of maximum heat input against evaporator elevation agree well with the manufacturer's predictions.

Tower, L. K.↗

Coherent microwave backscatter of natural snowpacks

The backscatter of natural snowpacks was measured using a swept-frequency system operating from 5.8 to 8.0 GHz. Snow layering produced sequences of maxima and minima in backscatter intensity, with typical peak-to-valley ratios of 15 db. Wetness produced in the upper portion of the snowpack by solar heat input enhanced the effect of layering. The layer response persisted for incidence exhibits predominantly coherent properties. Frequency modulation of the incident signal masked the layer response by averaging the unmodulated response over the bandwidth represented by the modulation. Further changes in backscatter were attributed to changes in wetness in the surface regions of the snowpack; for a fixed frequency of 13.5 GHz and incidence angle of 39 deg, the backscatter decreased typically 15 db between 11 A.M. and noon, and returned to approximately its initial level of overnight.

Linlor, W. I.↗

The thermoelastic patch contact problem for large Peclet number

An equation in the form of a Fourier series was derived in an earlier study to give displacements of the originally straight edge of a plate as the result of a small heat input patch moving at speed c along that edge. That unwieldly formulation is reduced to a simple integral equation, which is shown to be manageable in an example calculation. The integral equation is shown to be closely related to that of Ling and Mow, although it is much simpler to use. Comparison of the results of the simplification to results of the original series formulation suggest that the equation proposed for 'high Peclet number' may be a valid approximation for Peclet number as low as 2.5.

Kilaparti, S. R.↗

The Martian ionosphere in light of the Viking observations

A theoretical model has been constructed in which the ion density and the ion and electron temperature distributions are calculated by solving the coupled continuity-momentum equations and the coupled energy equations. The latest experimental results from the Viking 1 and 2 landers are used to vary some of the parameters in the model in order to obtain agreement between the theoretical and experimental results. It is found that solar EUV radiation alone is not able to maintain the observed high ion temperatures. It was also established that the energy coupling between the electron and ion gas is insufficient to account for the measured ion temperatures even in the presence of very large electron temperatures. Direct heat input to the ion gas, probably due to solar wind-ionosphere interactions, can result in ion temperature values in reasonable agreement with the observations. The ion densities calculated with the present model agree well with the Viking observations in the chemically controlled region, but at higher altitudes, dynamic transport processes need to be invoked to achieve consistency among the observed and calculated temperature and density values.

Chen, R. H.↗

Transient shutdown analysis of low-temperature thermal diodes

The various thermal diodes available for use in cryogenic systems are described. Two diode types, liquid-trap and liquid-blockage diodes, were considered to be the most attractive, and thermal models were constructed to predict their behavior in the reverse mode. The diodes, which are of similar size and throughput, were also examined experimentally in a parallel test setup under nominally identical conditions. Their characteristics were ascertained in terms of forward-mode and reverse-mode conductances, shutdown times and energies, and recovery to forward-mode operation with ethane as the working fluid in the temperature range 170 K to 220 K. Results show that the liquid-blockage diode is the quicker of the two diodes to shut down from the forward mode (8 min as opposed to 10 min). However, the liquid-blockage diode has a larger reverse-mode conductance which results in a greater overall evaporator temperature rise. The importance of the relative size and heat inputs to the condenser/reservoir configuration of the liquid-blockage diode and the evaporator trap configuration for the liquid-trap diode are demonstrated. Also included are data which show the susceptibility of the diodes to recovery to forward-mode operation. Guidelines for the choice of a particular diode for an actual application are given.

Williams, R. J.↗

Analytical predictions of selenide RTG power degradation

A mathematical model for the performance and degradation analysis of an RTG using the newly developed selenide thermoelectric materials has been developed at JPL. The computerized model is quite comprehensive and enables the accurate detailing of the electrical and thermal effects that take place within the thermocouple under any desired set of operation conditions, including heat input, ambient temperature and load conditions. The paper discusses the logic flow of the computer model and presents the time and temperature dependent results for various degradation mechanisms and rates as they have been established to date.

Noon, E. L.↗

Improved apparatus for trapped radical and other studies down to 1.5 K

A Dewar system and associated equipment for electron paramagnetic resonance (EPR) studies of trapped free radicals and other optical or irradiation experiments are described. The apparatus is capable of reaching a temperature of 1.5 K and transporting on the order of 20 W per K temperature gradient; its principal advantages are for use at pumped cryogen temperatures and for experiments with large heat inputs. Two versions of the apparatus are discussed, one of which is designed for EPR in a rectangular cavity operating in a TE(102) mode and another in which EPR is performed in a cylindrical microwave cavity.

Woollam, J. A.↗

Fragmentation of molecular clouds

Fragmentation is generally considered to be the initial process that a molecular cloud must undergo before stars can form. Yet its role in determining the final mass spectrum remains obscure. It appears that gravitational fragmentation, considered as a unique process, is unsatisfactory. Both fragmentation and complementary physical processes are, therefore, discussed. One of the principle aims of the discussion is to indicate how stars of solar mass (and more generally, how the initial mass spectrum of stars) can form. Attention is given to the evidence for fragmentation, opacity-limited fragmentation, magnetic flux-limited fragmentation, fragmentation induced by molecule formation and excitation, protostellar heat input, fragment coalescence, accretion, binary formation, and probabilistic theories.

Silk, J.↗

Wake flowfields for Jovian probe

The wake flow field developed by the Galileo probe as it enters the Jovian atmosphere was modeled. The wake produced by the probe is highly energetic, yielding both convective and radiative heat inputs to the base of the probe. A component mathematical model for the inviscid near and far wake, the viscous near and far wake, and near wake recirculation zone was developed. Equilibrium thermodynamics were used for both the ablation and atmospheric species. Flow fields for three entry conditions were calculated. The near viscous wave was found to exhibit a variable axial pressure distribution with the neck pressure approximately three times the base pressure. Peak wake flow field temperatures were found to be in proportion to forebody post shock temperatures.

Engel, C. D.↗

Emergency relief venting of the infrared telescope liquid helium dewar

An analysis is made of the emergency relief venting of the liquid helium dewar of the Spacelab 2 infrared telescope experiment in the event of a massive failure of the dewar guard vacuum. Such a failure, resulting from a major accident, could cause rapid heating and pressurization of the liquid helium in the dewar and lead to relief venting through the emergency relief system. The heat input from an accident is estimated for various fluid conditions in the dewar and the relief process as it takes place through one or both of the emergency relief paths is considered. It is shown that under all reasonable circumstances the dewar will safely relieve itself, and the pressure will not exceed 85 percent of the proof pressure or 63 percent of the burst pressure.

Urban, E. W.↗

Emergency relief venting of the infrared telescope liquid helium dewar, second edition

An updated analysis is made of the emergency relief venting of the liquid helium dewar of the Spacelab 2 Infrared Telescope experiment in the event of a massive failure of the dewar guard vacuum. Such a failure, resulting from a major accident, could cause rapid heating and pressurization of the liquid helium in the dewar and lead to relief venting through the emergency relief system. The heat input from an accident is estimated for various fluid conditions in the dewar and the relief process considered as it takes place through one or both of the emergency relief paths. It was previously assumed that the burst diaphragms in the dewar relief paths would rupture at a pressure of 65 psi differential or 4.4 atmospheres. In fact, it has proved necessary to use burst diaphragms in the dewar which rupture at 115 psid or 7.8 atmospheres. An analysis of this case was carried out and shows that when the high pressure diaphragm rupture occurs, the dewar pressure falls within 8 s to below the 4.4 atmospheres for which the original analysis was performed, and thereafter it remains below that level.

Urban, E. W.↗