Search NASA⌕ Search

SEARCH · Search NASA

Results for “High contrast imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

High-resolution in-situ characterization of laser powder bed fusion via transmission X-ray microscopy at X-ray free electron lasers

In this work, we describe the instrumentation used to perform the first operando transmission X-ray microscopy (TXM) and simultaneous X-ray diffraction of laser melting simulating laser powder bed fusion on the XCS instrument at the Linac Coherent Light Source (LCLS) X-ray free-electron laser (XFEL). Our TXM with 40× magnification in the X-ray regime at 11 keV gave spatial resolutions down to 940 nm per line pair, with effective pixel sizes down to 206 nm, image integration times of <100 fs, and frame rates tunable between 2.1 and 119 ns for two probe frames (0.48 GHz to 8.4 MHz). Images were recorded on Zyla and Icarus (UXI) detectors to trade off between spatial resolution and time dynamics. A 1 kW CW IR laser was coupled into the interaction point to conduct pump–probe studies of laser melting and solidification dynamics. Our temporal and spatial resolution with attenuation-based contrast exceeds that currently possible with synchrotron-based high-speed radiography. This system was sensitive to feature velocities of 10–12000 m s −1 but we did not observe any motion in this range in the laser melting of Al6061 alloy. Shockwaves were not observed and hot cracking proceeded at velocities below the detection limits. Pore accumulation was observed between successive shots, indicating that bubble escape mechanisms were not active. With proper experimental design, the spatial resolution, contrast and field of view could be further improved or modified. The increased brightness and narrower bandwidth of the XFEL allowed for this imaging technique and it lays the groundwork for a wide range of operando techniques to study additive manufacturing.

47 OTHER INSTRUMENTATION↗

Coalescence of GaP on V-Groove Si

In recent years, better understanding and control over the formation of crystalline defects during the direct epitaxy of III-V semiconductors on Si substrates via metal organic vapor phase epitaxy (MOVPE) has enabled large gains in III-V-on-Si solar cell efficiency, pointing to pathway to lower-cost, high-performance III-V solar cells. However, such results have only been achieved on costly chemo-mechanically-polished (CMP) Si wafers. The use of V-groove nanopatterned Si substrates has demonstrated similarly high-crystalline-quality III-V-on-Si epitaxy, but also can be combined with lower-cost polishing techniques. Although they offer a potential cost advantage, growth on V-groove substrates adds challenges not present for epitaxy on planar wafers (the III-V material must be coalesced into a thin film after an initial nucleation stage). MOVPE growth conditions that promote highly facet-selective lateral growth needed for coalescence are generally actively avoided for conventional thin fim growth, so growth conditions need to be re-developed for V-groove-based epitaxy. Additionally, coalescence add complexity to the dislocation dynamics related to lattice relaxation, so strategies used to keep threading dislocation density (TDD) low on planar substrates need to be re-tuned for V-grooves. We have studied the morphological evolution and dislocation dynamics of GaP grown on V-groove Si by MOVPE. Growth conditions of V/III=5,000 and Tg=800 degrees C were uniquely found to produce extremely smooth coalesced thin films, with an RMS roughness of 0.2 nm measured by AFM. Additionally, at this growth condition, we identified two regimes of growth determined by the width of the SiNx cap (a remnant of the nanopatterning process) at the top of the V-grooves. For narrow caps, the GaP coalesces into a thin film, and for wide caps, the GaP evolves into {1 1 1}-faceted diamonds that do not coalesce. We suggest the influence of Si from the sidewalls of the V-grooves on the surface reconstruction of the GaP as the mechanism for this effect, with reflection difference spectroscopy (RDS) and Si doping experiments supporting this theory. In addition to morphology, the dislocation dynamics of the system were studied with electron channeling contrast imaging (ECCI) and transmission electron microscopy (TEM). The TDD of the coalesced GaP films was found to be 5 x 10^7 cm^-2 after coalescence via ECCI, a level still too high for high-quality solar cells. However, misfit dislocations crossing multiple grooves greater than 20 micrometers long were observed in ECCI, suggesting that the V-grooves do not block dislocation glide. TEM prior to and after coalescence was used to distinguish between dislocation creation driven by growth conditions and coalescence. Finally, strategies to reduce the dislocation density to levels acceptable for solar cells will be discussed.

GaP↗

Spatial Mapping of Electrostatic Fields in 2D Heterostructures

In situ electron microscopy is an effective tool for understanding the mechanisms driving novel phenomena in 2D structures. However, due to practical challenges, it is difficult to address these technologically relevant 2D heterostructures with electron microscopy. Here, we use the differential phase contrast (DPC) imaging technique to build a methodology for probing local electrostatic fields during electrical operation with nanoscale spatial resolution in such materials. We find that, by combining a traditional DPC setup with a high-pass filter, we can largely eliminate electric fluctuations emanating from short-range atomic potentials. Using a method based on this filtering algorithm, a priori electric field expectations can be directly compared with experimentally derived values to readily identify inhomogeneities and potentially problematic regions. Furthermore, we use this platform to analyze the electric field and charge density distribution across layers of hBN and MoS 2 .

79 ASTRONOMY AND ASTROPHYSICS↗

Digital coded exposure formation of frames from event-based imagery

Abstract Event-driven neuromorphic imagers have a number of attractive properties including low-power consumption, high dynamic range, the ability to detect fast events, low memory consumption and low band-width requirements. One of the biggest challenges with using event-driven imagery is that the field of event data processing is still embryonic. In contrast, decades worth of effort have been invested in the analysis of frame-based imagery. Hybrid approaches for applying established frame-based analysis techniques to event-driven imagery have been studied since event-driven imagers came into existence. However, the process for forming frames from event-driven imagery has not been studied in detail. This work presents a principled digital coded exposure approach for forming frames from event-driven imagery that is inspired by the physics exploited in a conventional camera featuring a shutter. The technique described in this work provides a fundamental tool for understanding the temporal information content that contributes to the formation of a frame from event-driven imagery data. Event-driven imagery allows for the application of arbitrary virtual digital shutter functions to form the final frame on a pixel-by-pixel basis. The proposed approach allows for the careful control of the spatio-temporal information that is captured in the frame. Furthermore, unlike a conventional physical camera, event-driven imagery can be formed into any variety of possible frames in post-processing after the data is captured. Furthermore, unlike a conventional physical camera, coded-exposure virtual shutter functions can assume arbitrary values including positive, negative, real, and complex values. The coded exposure approach also enables the ability to perform applications of industrial interest such as digital stroboscopy without any additional hardware. The ability to form frames from event-driven imagery in a principled manner opens up new possibilities in the ability to use conventional frame-based image processing techniques on event-driven imagery.

47 OTHER INSTRUMENTATION↗

High Optical-to-X-Ray Polarization Ratio Reveals Compton Scattering in BL Lacertae’s Jet

Blazars, supermassive black hole systems with highly relativistic jets aligned with the line of sight, are the most powerful long-lived emitters of electromagnetic emission in the Universe. We report here on a radio-to-gamma-ray multiwavelength campaign on the blazar BL Lacertae with unprecedented polarimetric coverage from radio to X-ray wavelengths. The observations caught an extraordinary event on 2023 November 10–18, when the degree of linear polarization of optical synchrotron radiation reached a record value of 47.5%. In stark contrast, the Imaging X-ray Polarimetry Explorer found that the X-ray (Compton scattering or hadron-induced) emission was polarized at less than 7.4% (3 σ confidence level). We argue here that this observational result rules out a hadronic origin of the high-energy emission and strongly favors a leptonic (Compton scattering) origin, thereby breaking the degeneracy between hadronic and leptonic emission models for BL Lacertae and demonstrating the power of multiwavelength polarimetry to address this question. Furthermore, the multiwavelength flux and polarization variability, featuring an extremely prominent rise and decay of the optical polarization degree, is interpreted for the first time by the relaxation of a magnetic “spring” embedded in the newly injected plasma. This suggests that the plasma jet can maintain a predominant toroidal magnetic field component parsecs away from the central engine.

79 ASTRONOMY AND ASTROPHYSICS↗

Radiation and heat transport in divergent shock–bubble interactions

Shock–bubble interactions (SBIs) are important across a wide range of physical systems. In inertial confinement fusion, interactions between laser-driven shocks and micro-voids in both ablators and foam targets generate instabilities that are a major obstacle in achieving ignition. Experiments imaging the collapse of such voids at high energy densities (HED) are constrained by spatial and temporal resolution, making simulations a vital tool in understanding these systems. In this study, we benchmark several radiation and thermal transport models in the xRAGE hydrodynamic code against experimental images of a collapsing mesoscale void during the passage of a 300 GPa shock. We also quantitatively examine the role of transport physics in the evolution of the SBI. This allows us to understand the dynamics of the interaction at timescales shorter than experimental imaging framerates. We find that all radiation models examined reproduce empirical shock velocities within experimental error. Radiation transport is found to reduce shock pressures by providing an additional energy pathway in the ablation region, but this effect is small (∼1% of total shock pressure). Employing a flux-limited Spitzer model for heat conduction, we find that flux limiters between 0.03 and 0.10 produce agreement with experimental velocities, suggesting that the system is well-within the Spitzer regime. Higher heat conduction is found to lower temperatures in the ablated plasma and to prevent secondary shocks at the ablation front, resulting in weaker primary shocks. Finally, we confirm that the SBI-driven instabilities observed in the HED regime are baroclinically driven, as in the low energy case.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantitative X-ray tomographic analysis reveals calcium precipitation in cataractogenesis

Cataracts, named for pathological light scattering in the lens, are known to be associated with increased large protein aggregates, disrupted protein phase separation, and/or osmotic imbalances in lens cells. We have applied synchrotron phase contrast X-ray micro-computed tomography to directly examine an age-related nuclear cataract model in Cx46 knockout (Cx46KO) mice. High-resolution 3D X-ray tomographic images reveal amorphous spots and strip-like dense matter precipitates in lens cores of all examined Cx46KO mice at different ages. The precipitates are predominantly accumulated in the anterior suture regions of lens cores, and they become longer and dense as mice age. Alizarin red staining data confirms the presence of calcium precipitates in lens cores of all Cx46KO mice. This study indicates that the spatial and temporal calcium precipitation is an age-related event associated with age-related nuclear cataract formation in Cx46KO mice, and further suggests that the loss of Cx46 promotes calcium precipitates in the lens core, which is a new mechanism that likely contributes to the pathological light scattering in this age-related cataract model.

60 APPLIED LIFE SCIENCES↗

Quantum imaging with positronium-decay-emitted gamma rays

The use of entangled gamma rays from positronium decay for quantum-enhanced imaging of dense materials is demonstrated. Quantum ghost images, where only one of the entangled 511-keV photons interacts with the object, are obtained for tantalum samples of varying density using a 210-ps time-resolution dual detector system and a Na-22 positron source. An analysis comparing both classical and quantum imaging modalities is employed to isolate true 511-keV events from background noise. Image quality is quantitatively assessed using transmission ratios and the Michelson contrast. Quantum-correlated images are found to exhibit superior (up to approximately 1.7x, from 0.49 to 0.83 in the thickest sample measured) contrast compared to classical methods and align well with theoretical expectations. These results suggest that quantum ghost imaging with positronium-based entangled gamma rays could significantly enhance noninvasive imaging of high-density objects, with potential applications in areas such as cargo inspection and security screening.

36 MATERIALS SCIENCE↗

High-Resolution Imaging of Unstained Polymer Materials

Electron microscopy has played an important role in polymer characterization. Traditionally, electron diffraction is used to study crystalline polymers while transmission electron microscopy is used to study microphase separation in stained block copolymers and other multiphase systems. We describe developments that eliminate the barrier between these two approaches - it is now possible to image polymer crystals with atomic resolution. The focus of this Review is on high-resolution imaging (30 Å and smaller) of unstained polymers. Recent advances in hardware allow for capturing numerous (as many as 105) low-dose images from an unperturbed specimen; beam damage is a significant barrier to high-resolution electron microscopy of polymers. Machine-learning-based software is then used to sort and average the images to retrieve pristine structural information from a collection of noisy images. Acknowledging the heterogeneity in polymer samples prior to averaging is essential. Molecular conformations in a wide range of amphiphilic block copolymers, polymerized ionic liquids, and conjugated polymers can be gleaned from two-dimensional projections (2D), three-dimensional (3D) tomograms, and four-dimensional (4D) scanning transmission electron microscopy (STEM) data sets where 2D diffraction patterns are taken as a function of position. Some methods such as phase contrast STEM have been used to image closely related materials such as metal-organic frameworks but not polymers. With improvements in hardware and software, such methods may soon be applied to polymers. Our goal is to provide a comprehensive understanding of the strategies toward the high-resolution imaging of radiation sensitive polymer materials at different length scales.

36 MATERIALS SCIENCE↗

Non-Destructive, Three-Dimensional Imaging of Processes in the Rhizosphere Utilizing High Energy Photons

Soil structure, which can be described as the aggregation and distribution of pore spaces, regulates carbon, nutrient, and water cycling across the Earth system. Yet the inability to make quantitative, dynamic, in situ measurements of soil structure and rhizosphere carbon flow has prevented meaningful incorporation of soil structural processes into Earth System Models (ESMs). The key limitations are: (i) Lack of scale integration between micron-scale soil structure and ecosystem-scale models, (ii) Poor functional linkage between soil structural properties and biogeochemical processes, and (iii) Absence of dynamic 3D measurements of rhizosphere structural changes and carbon transformations. To address these challenges, we developed a new integrated positron emission tomography (PET) - microcomputed tomography (CT) imaging platform that enables the first 4D (spatial 3D and time), non-invasive, quantitative imaging of carbon allocation and rhizosphere structural dynamics in living plants and intact soils. The system combines: • Rhizo-PET (R-PET): a high-resolution positron emission tomography scanner optimized for 11 CO 2 tracing in plant roots. • a-Se micro-CT: a high-contrast, high-spatial resolution CT system based on amorphous selenium (a-Se) direct conversion technology, enabling micron-scale visualization of soil structure and root–soil interfaces. Together, these advances allow us to quantify how carbon exudates move, transform, and stabilize within the rhizosphere, directly informing missing processes in BER-relevant carbon cycle models.

42 ENGINEERING↗

Characterizing the uppermost 100 m structure of the San Jacinto fault zone southeast of Anza, California, through joint analysis of geological, topographic, seismic and resistivity data

We present results from complementary geological, topographic, seismic and electrical resistivity surveys at the Sagebrush Flat (SGB) site along the Clark fault (CF) strand of the San Jacinto fault zone trifurcation area southeast of Anza, California. Joint interpretation of these data sets, each with unique spatiotemporal sensitivities, allow us to better characterize the shallow (<100 m) fault zone at this structurally complex site. Geological mapping at the surface shows the CF has three main subparallel strands within a <100 m zone with varying degrees of rock damage. These strands intersect units of banded gneiss and tonalite, and various sedimentary units. Near the surface, the weathered but more intact tonalite and gneiss to the southwest have relatively high VP. The low-lying flat sedimentary basins around the two southwestern-most CF strands and elevated damaged gneiss to the northeast have lowest VP <500 m s–1. The high relief of the northeast gneiss unit may in part be explained by its extensive damage and inferred increased relative rock uplift. Resistivity imaging shows the unconsolidated dry basin sediments (maximum >1300 Ohm.m) contrasted against the compacted fine-grained (potentially wet) materials within the CF core and the Bautista Formation (minimum <40 Ohm.m), which is slightly elevated above the flat basins. The inverse relationship between VP (increases) and resistivity (decreases) in the uppermost ~15 m can be characterized as log–log linear with slopes of –2.6 to –4. At depths >30 m, the velocity heterogeneity near the surface merges into larger-scale structures that are generally slower on the northeast side of the CF core compared to the southwest side (as much as ~40 per cent reduction in average VP). A previous study revealed a 20–37 per cent variability in peak ground velocities across the SGB site from local earthquakes. The upper end of that range is associated with the near-surface unconsolidated sedimentary basins and northeast damaged gneiss unit. Preliminary analysis of time-dependent topography mostly shows effects of changing vegetation and anthropogenic activity.

Geochemistry & Geophysics↗

Li-ion Battery Material phase prediction through Hierarchical Curriculum Learning

Li-ion Batteries (LIB), one of the most efficient energy storage devices, are widely adopted in many industrial applications. Imaging data of these battery electrodes obtained from X-ray tomography can explain the distribution of material constituents and allow reconstructions to study electron transport pathways. Therefore, it can eventually help quantify various associated properties of electrodes (e.g., volume-specific surface area, porosity) which determine the performance of batteries. However, these images often suffer from low image contrast between multiple material constituents , making it difficult for humans to distinguish and characterize these constituents through visualization. A minor error in detecting distributions among the material constituents can lead to a high error in the calculated parameters of material properties.We present a novel hierarchical curriculum learning framework to address the complex task of estimating material constituent distribution in battery electrodes. To provide spatially smooth prediction, our framework comprises three modules: (i) an uncertainty-aware model trained to yield inferences conditioned upon global knowledge of material distribution, (ii) a technique to capture relatively more fine-grained (local) distributional signals, (iii) an aggregator to appropriately fuse the local and global effects towards obtaining the final distribution.

Tabassum, Anika↗

Quantitative Bioluminescence Tomography-Guided Conformal Irradiation for Preclinical Radiation Research

Widely used cone beam computed tomography (CBCT)-guided irradiators in preclinical radiation research are limited to localize soft tissue target because of low imaging contrast. Knowledge of target volume is a fundamental need for radiation therapy (RT). Without such information to guide radiation, normal tissue can be overirradiated, introducing experimental uncertainties. This led us to develop high-contrast quantitative bioluminescence tomography (QBLT) for guidance. The use of a 3-dimensional bioluminescence signal, related to cell viability, for preclinical radiation research is one step toward biology-guided RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Disentangling the role of ectomycorrhizal fungi in plant nutrient acquisition along a Zn gradient using X-ray imaging

Zinc (Zn) is a plant essential micronutrient involved in a wide range of cellular processes. Ectomycorrhizal fungi (EMF) are known to play a critical role in regulating plant Zn status. However, how EMF control uptake and translocation of Zn and other nutrients in plant roots under different Zn conditions is not well known. Using X-ray fluorescence imaging, we found the EMF species Suillus luteus increased pine root Zn acquisition under low Zn concentrations and reduced its accumulation under higher Zn levels. By contrast, non-mycorrhizal pine roots exposed to high Zn indiscriminately take up and translocate Zn to root tissues, leading to Zn stress. Regardless of S. luteus inoculation, the absorption pattern of Ca and Cu was similar to Zn. Compared to Ca and Cu, effects of S. luteus on Fe acquisition were more marked, leading to a negative association between Zn addition and Fe concentration within EMF roots. Besides, higher nutrient accumulation in the fungal sheath, compared to hyphae inhabiting between intercellular space of cortex cells, implies the fungal sheath serves as a barrier to regulate nutrient transportation into fungal Hartig net. Furthermore, our results demonstrate the crucial roles EMF play in plant nutrient uptake and how fungal partners ameliorate soil chemical conditions either by increasing or decreasing element uptake.

36 MATERIALS SCIENCE↗

X-ray microscopy and talbot imaging with the matter in extreme conditions X-ray imager at LCLS

The last decade has shown the great potential that X-ray Free Electron Lasers (FEL) have to study High Energy Density (HED) physics. Experiments at FELs have made significant breakthroughs in Shock Physics and Dynamic Diffraction, Dense Plasma Physics and Warm Dense Matter Science, using techniques such as isochoric heating, inelastic scattering, small angle scattering and X-ray diffraction. In addition, and complementary to these techniques, the coherent properties of the FEL beam can be used to image HED samples with high fidelity. We present new imaging diagnostics and techniques developed at the Matter in Extreme Conditions (MEC) instrument at Linac Coherent Light Source (LCLS) over the last few years. We show results in Phase Contrast Imaging geometry, where the X-ray beam propagates from the target to a camera revealing its phase, as well as in Direct Imaging geometry, where a real image of the sample plane is produced in the camera with a spatial resolution down to 200 nm. Last, we show an implementation of the Talbot Imaging method allowing both X-ray phase and intensity measurements change introduced by a target with sub-micron resolution.

47 OTHER INSTRUMENTATION↗

Phase retrieval for refraction-enhanced x-ray radiography using a deep neural network

X-ray refraction-enhanced radiography (RER) or phase contrast imaging is widely used to study internal discontinuities within materials. The resulting radiograph captures both the decrease in intensity caused by material absorption along the x-ray path, as well as the phase shift, which is highly sensitive to gradients in density. A significant challenge lies in effectively analyzing the radiographs to decouple the intensity and phase information and accurately ascertain the density profile. Conventional algorithms often yield ambiguous and unrealistic results due to difficulties in including physical constraints and other relevant information. We have developed an algorithm that uses a deep neural network to address these issues and applied it to extract the detailed density profile from an experimental RER. To generalize the applicability of our algorithm, we have developed a technique that quantitatively evaluates the complexity of the phase retrieval process based on the characteristics of the sample and the configuration of the experiment. Accordingly, this evaluation aids in the selection of the neural network architecture for each specific case. Beyond RER, the model has potential applications for other diagnostics where phase retrieval analysis is required.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Deep Multimodal Networks for M-type Star Classification with Paired Spectrum and Photometric Image

Abstract Traditional stellar classification methods include spectral and photometric classification separately. Although satisfactory results can be achieved, the accuracy could be improved. In this paper, we pioneer a novel approach to deeply fuse the spectra and photometric images of the sources in an advanced multimodal network to enhance the model’s discriminatory ability. We use Transformer as the fusion module and apply a spectrum–image contrastive loss function to enhance the consistency of the spectrum and photometric image of the same source in two different feature spaces. We perform M-type stellar subtype classification on two data sets with high and low signal-to-noise ratio (S/N) spectra and corresponding photometric images, and the F1-score achieves 95.65% and 90.84%, respectively. In our experiments, we prove that our model effectively utilizes the information from photometric images and is more accurate than advanced spectrum and photometric image classifiers. Our contributions can be summarized as follows: (1) We propose an innovative idea for stellar classification that allows the model to simultaneously consider information from spectra and photometric images. (2) We discover the challenge of fusing low-S/N spectra and photometric images in the Transformer and provide a solution. (3) The effectiveness of Transformer for spectral classification is discussed for the first time and will inspire more Transformer-based spectral classification models.

Astronomy & Astrophysics↗

The Wendelstein 7-X phase contrast imaging diagnostic

We report a phase contrast imaging (PCI) diagnostic has been developed for the Wendelstein 7-X (W7-X) stellarator. The PCI diagnostic provides a line-integrated measurement of turbulent electron density fluctuations, which is essential for understanding high performance scenarios that can lead to improved confinement at fusion-relevant temperatures and densities. The PCI system is also sensitive to coherent fluctuations, which arise from Alfvén eigenmodes or other MHD activity. This paper provides an overview of the hardware and the optical system and presents an example PCI measurement from the W7-X OP1.2b experimental campaign.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗