Search NASA⌕ Search

SEARCH · Search NASA

Results for “High dynamic range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Space-Based Range Safety and Future Space Range Applications

The National Aeronautics and Space Administration (NASA) Space-Based Telemetry and Range Safety (STARS) study is a multiphase project to demonstrate the performance, flexibility and cost savings that can be realized by using space-based assets for the Range Safety [global positioning system (GPS) metric tracking data, flight termination command and range safety data relay] and Range User (telemetry) functions during vehicle launches and landings. Phase 1 included flight testing S-band Range Safety and Range User hardware in 2003 onboard a high-dynamic aircraft platform at Dryden Flight Research Center (Edwards, California, USA) using the NASA Tracking and Data Relay Satellite System (TDRSS) as the communications link. The current effort, Phase 2, includes hardware and packaging upgrades to the S-band Range Safety system and development of a high data rate Ku-band Range User system. The enhanced Phase 2 Range Safety Unit (RSU) provided real-time video for three days during the historic Global Flyer (Scaled Composites, Mojave, California, USA) flight in March, 2005. Additional Phase 2 testing will include a sounding rocket test of the Range Safety system and aircraft flight testing of both systems. Future testing will include a flight test on a launch vehicle platform. This paper discusses both Range Safety and Range User developments and testing with emphasis on the Range Safety system. The operational concept of a future space-based range is also discussed.

Whiteman, Donald E.↗

Measurement report: The Fifth International Workshop on Ice Nucleation phase 1 (FIN-01): intercomparison of single-particle mass spectrometers

Knowledge of the chemical composition and mixing state of aerosols at a single-particle level is critical for gaining insights into atmospheric processes. One common tool to make these measurements is single-particle mass spectrometry. There remains a need to compare the performance of different single-particle mass spectrometers (SPMSs). An intercomparison of SPMSs was conducted at the Aerosol Interaction and Dynamics in the Atmosphere (AIDA) chamber at the Karlsruhe Institute of Technology (KIT) in November 2014, as part of the first phase of the Fifth International Workshop on Ice Nucleation (FIN-01). In this paper we compare size distributions and mass spectra of atmospherically relevant particle types measured by five SPMSs. These include different minerals, desert and soil dusts, soot, bioaerosol (Snomax; protein granule), secondary organic aerosol (SOA), and SOA-coated mineral particles. Most SPMSs reported similar vacuum aerodynamic diameter (d va ) within typical instrumental ranges from ~100–200 nm (lower limit) to ~2–3 µm (upper limit). In general, all SPMSs exhibited a wide dynamic range (up to ~10 3 ) and high signal-to-noise ratio (up to ~10 4 ) in mass spectra. Common spectral features with small diversities in mass spectra were found with high average Pearson's correlation coefficients, i.e., for average positive spectra r avg-pos =0.74 ± 0.12 and average negative spectra r avg-neg =0.67 ± 0.22. We found that instrument-specific detection efficiency (DE) was more dependent on particle size than particle type, and particle identification favored the use of bipolar, rather than monopolar, instruments. Particle classification from “blind experiments” showed that all instruments differentiated SOA, soot, and soil dust and detected subtle changes in the particle internal mixing but had difficulties differentiating among specific mineral types and dusts. This study helps to further understand the capabilities and limitations of the single-particle mass spectrometry technique in general and the specific performance of the instrument in characterizing atmospheric aerosol particles.

54 ENVIRONMENTAL SCIENCES↗

Soft X-ray sources in the bar of the Large Magellanic Cloud

X-ray observations of the Large Magellanic Cloud were made with two collimated proportional counters having high angular resolution, a wide spectral dynamic range and a large aperture. Counting rates in the two detectors during the entire rocket flight are presented, and a number of soft X-ray (0.5-2 keV) sources were found in the bar of the LMC, having luminosities between 10 to the 37th and 10 to the 38th ergs/s. Emission in the 0.15-0.28 keV band from LMC X-3 was also detected.

Mckee, J. D.↗

High dynamic, low volume GPS receiver

A new GPS receiver concept and design are presented to meet the high dynamic and low volume requirements for range applications in missiles and drones. The receiver has the potential to satisfy all range requirements with one basic receiver, which has significant potential economic benefit over the alternate approach of using a family of receivers, each tailored for specific applications. The main new concept is to use approximate maximum likelihood estimates of pseudo range and range-rate, rather than tracking with carrier phase locked loops and code delay locked loops. Preliminary analysis indicates that receivers accelerating at 50 g or more can track with position errors due to acceleration of approximately 0.2 m/g, or 10 m at 50 g. Implementation is almost entirely digital to meet the low volume requirements.

Hurd, W. J.↗

The IRM fluxgate magnetometer

This report describes the three-axis fluxgate magnetometer instrument on board the AMPTE IRM spacecraft. Important features of the instrument are its wide dynamic range (0.1-60,000 nT), a high resolution (16-bit analog to digital conversion) and the capability to operate automatically or via telecommand in two gain states. In addition, the wave activity is monitored in all three components up to 50 Hz. Inflight checkout proved the nominal functioning of the instrument in all modes.

Luehr, H.↗

Unsteady pressure and structural response measurements of an elastic supercritical wing

Results are presented which define unsteady flow conditions associated with high dynamic response experienced on a high aspect ratio elastic supercritical wing at transonic test conditions while being tested in the NASA Langley Transonic Dynamics Tunnel. The supercritical wing, designed for a cruise Mach number of 0.80, experienced the high dynamic response in the Mach number range from 0.90 to 0.94 with the maximum response occurring at a Mach number of approximately 0.92. At the maximum wing response condition the forcing function appears to be the oscillatory chordwise movement of strong shocks located on both the wing upper and lower surfaces in conjunction with the flow separating and reattaching in the trailing edge region.

Eckstrom, Clinton V.↗

Unsteady pressure and structural response measurements on an elastic supercritical wing

Results are presented which define unsteady flow conditions associated with high dynamic response experienced on a high aspect ratio elastic supercritical wing at transonic test conditions while being tested in the NASA Langley Transonic Dynamics Tunnel. The supercritical wing, designed for a cruise Mach number of 0.80, experienced the high dynamic response in the Mach number range from 0.90 to 0.94 with the maximum response occurring at a Mach number of approximately 0.92. At the maximum wing response condition the forcing function appears to be the oscillatory chordwise movement of strong shocks located on both the wing upper and lower surfaces in conjuction with the flow separating and reattaching in the trailing edge region.

Eckstrom, Clinton V.↗

The X-ray spectral variability of the BL Lacertae type object PKS 2155-304

We present a detailed study of the hard X-ray properties of the BL Lacertae object PKS 2155-304 based on measurements made in 1988 and 1989 with the Large Area Counter (LAC) on board the Ginga satellite. The source exhibited a high degree of variability with a dynamic range of a factor 7 in the 2-6 keV band. The fastest amplitude variation was a factor 2 decline in the intensity in this band within 4 hours. The spectrum is characterized by a break which occurs at about 4 keV. Spectral fits to the data integrated in 6400 s time bins reveal that, in common with previous observations of BL Lacertae objects, the spectral slope is generally anticorrelated with intensity in the sense that the spectrum hardens as the intensity increases. However, the tracks of sequential points in the index-intensity plane are occasionally seen to differ during the rise and decay stages of individual flares. Furthermore, during one, or possibly two, flaring episodes the spectral index is observed to correlate with intensity variations.

Sembay, S.↗

Ultra-Stable Spectrometer for Sky-Scanning, Sun-Tracking Atmospheric Research (5STAR)

The Spectrometer for Sky-Scanning, Sun-Tracking Atmospheric Research (4STAR) combines airborne sun tracking and sky scanning with diffraction spectroscopy to improve knowledge of atmospheric constituents and their links to airpollution and climate. Direct beam hyperspectral measurement of optical depth improves retrievals of gas constituentsand determination of aerosol properties. Sky scanning enhances retrievals of aerosol type and size distribution.Hyperspectral cloud-transmitted radiance measurements enable the retrieval of cloud properties from below clouds.These measurements tighten the closure between satellite and ground-based measurements. 4STAR incorporates amodular sun-tracking sky-scanning optical head with optical fiber signal transmission to rack mounted spectrometers,permitting miniaturization of the external optical tracking head, and future detector evolution.4STAR has supported a broad range of flight experiments since it was first flown in 2010. This experience provides thebasis for a series of improvements directed toward reducing measurement uncertainty and calibration complexity, andexpanding future measurement capabilities, to be incorporated into a new 5STAR instrument. A 9-channel photodioderadiometer with AERONET-matched bandpass filters will be incorporated to improve calibration stability. A wide dynamic range tracking camera will provide a high precision solar position tracking signal as well as an image of sky conditions around the solar axis. An ultrasonic window cleaning system design will be tested. A UV spectrometer tailored for formaldehyde and SO2 gas retrievals will be added to the spectrometer enclosure. Finally, expansion capability for a 4 channel polarized radiometer to measure the Stokes polarization vector of sky light will be incorporated. This paper presents initial progress on this next-generation 5STAR instrument.

atmosphere↗

Modeling and Optimizing Microwave Kinetic Inductance Detectors for the EXCLAIM Mission

Microwave Kinetic Inductance Detectors (MKIDs) are highly scalable detectors that have demonstrated background-limited sensitivity in space-like infrared environments. The detectors have a rich design space with many optimizable parameters, allowing high sensitivity measurements over a wide dynamic range. For these reasons, MKIDs are the chosen detectors for the Experiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM), a balloon-based telescope targeting nearly background-limited performance from 420- 540 GHz. We present an update on the design and measurements of the EXCLAIM MKID-spectrometer system, with a particular focus on microwave-induced pair-breaking and TLS noise. We have performed dark tests using a test detector, accurately describing the data through an MKID model mainly following existing literature with slight variations in TLS-fitting. We also review the overall architecture of the EXCLAIM detectors-spectrometer system, including an R=512 𝜇-Spec integrated spectrometer. This MKID-spectrometer system not only enables EXCLAIM with groundbreaking sensitivities to the astrophysical signal, but it also provides a critical pathfinder for future far-IR telescopes that may benefit from these technologies.

Trevor Mackintosh Oxholm↗

Remote displacement measurement using a passive interferometer with a fiber-optic link

Remote displacement measurement is demonstrated using a Fabry-Perot cavity with a multimode optical fiber link. The sensing cavity modulates, as a function of its length, the spectrum of a light-emitting diode (LED). The light returns via the fiber and is analyzed by a tunable reference cavity. A closed-loop control causes the reference cavity to track the sensing cavity length within 2 x 10 to the -12th m. Displacement range is 2 x 10 to the -6th m. The reference cavity length is measured interferometrically, using a laser, to obtain the sensing cavity length. Advantages of this sensing technique include compatibility with multimode fiber-optic components, high immunity to optical losses, and large dynamic range.

Beheim, G.↗

Physics-constrained superresolution diffusion for six-dimensional phase space diagnostics

Adaptive physics-constrained superresolution diffusion is developed for noninvasive virtual diagnostics of the six-dimensional (6D) phase space density of charged particle beams. An adaptive variational autoencoder embeds initial beam condition images and scalar measurements to a low-dimensional latent space from which a 32 6 pixel 6D tensor representation of the beam's 6D phase space density is generated. Projecting from a 6D tensor generates physically consistent two-dimensional projections. Physics-guided superresolution diffusion transforms low-resolution images of the 6D density to high resolution 256 × 256 pixel images. Unsupervised adaptive latent space tuning enables tracking of time-varying beams without knowledge of time-varying initial conditions. The method is demonstrated with experimental data and multiparticle simulations at the HiRES UED. The general approach is applicable to a wide range of complex dynamic systems evolving in high-dimensional phase space. The method is shown to be robust to distribution shift without retraining. Published by the American Physical Society 2025

43 PARTICLE ACCELERATORS↗

Magnetoplasmadynamic thruster development

Current research on self-field MPD thrusters presents the possibility of developing high power/low cost electric propulsion. The interest generated in this propulsion concept within both NASA and the U.S. Air Force has led to a coordinated interagency effort, and the recent completion of several test sites are expected to speed thruster concept development. Efficiencies approaching 40% at 2200 sec have been experimentally demonstrated. Among the characteristics recommending development of MPD thrusters are high thrust density and power handling capability, simplicity, and a wide dynamic range of thrust and specific impulse. MPD thrusters can, moreover, operate either continuously, at high available power levels, or in a pulsed mode, to match lower power levels.

Pawlik, E. V.↗

GLAST: Exploring Nature's Highest Energy Processes with the Gamma-ray Large Area Space Telescope

The Gamma-ray Large Area Space Telescope (GLAST) is an international and multi-agency space mission that will study the cosmos in the energy range 10 keV-300 GeV. Several successful exploratory missions in gamma-ray astronomy led to the Energetic Gamma Ray Experiment Telescope (EGRET) instrument on the Compton Gamma Ray Observatory (CGRO). Launched in 1991, EGRET made the first complete survey of the sky in the 30 MeV-10 GeV range. EGRET showed the high-energy gamma-ray sky to be surprisingly dynamic and diverse, with sources ranging from the sun and moon to massive black holes at large redshifts. Most of the gamma-ray sources detected by EGRET remain unidentified. In light of the discoveries with EGRET, the great potential of the next generation gamma-ray telescope can be appreciated. GLAST will have an imaging gamma-ray telescope vastly more capable than instruments flown previously, as well as a secondary instrument to augment the study of gamma-ray bursts. The main instrument, the Large Area Telescope (LAT), will have superior area, angular resolution, field of view, and deadtime that together will provide a factor of 30 or more advance in sensitivity, as well as provide capability for study of transient phenomena. The GLAST Burst Monitor (GBM) will have a field of view several times larger than the LAT and will provide spectral coverage of gamma-ray bursts that extends from the lower limit of the LAT down to 10 keV. The basic parameters of the GBM are compared to those of the Burst and Transient Source Experiment (BATSE) instrument on CGRO in Table 1-2. With the LAT and GBM, GLAST will be a flexible observatory for investigating the great range of astrophysical phenomena best studied in high-energy gamma rays. NASA plans to launch GLAST in late 2005.

Digel, Seth↗

Accurate and efficient parameterization of an atomic cluster expansion (ACE) potential for ammonia under extreme conditions

We present a machine learning interatomic potential for ammonia designed to capture its complex multiphase behavior, including both molecular and superionic phases. The potential is based on the atomic cluster expansion (ACE) formulation and has been parameterized to facilitate high-fidelity molecular dynamics simulations of ammonia under extreme conditions, for pressures up to 100 GPa and for temperatures above 500 K and up to 6000 K. A diverse range of configurations was generated through high-quality ab initio molecular dynamics simulations, covering insulating and superionic ice phases, liquid ammonia, molecular nitrogen (N 2 ) and hydrogen (H 2 ), and metastable compounds that form upon dissociation, including $NH^{+}_{4}$, $H^{+}_{3}$, N 2 H 4 , and N 3 H. We demonstrate that the ammonia ACE potential accurately reproduces experimental and density functional theory predicted isotherms and Hugoniots. Crucially, the potential is able to capture the intricate phase behavior of ammonia, including the transition from insulating molecular fluid to the superionic phase. This work provides a robust interatomic potential that can be used for large-scale, accurate simulations of ammonia under extreme thermodynamic conditions, offering a powerful tool for investigating its behavior in various phases and applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Testing the linearity of response of gated photomultipliers in wide dynamic range laser radar systems

Laser radar data acquisition systems have been utilized in conjunction with a light emitting diode to evaluate photomultipliers for laser radar use. Light pulses with an exponential decay rate of approximately one decade per sixty microseconds, as well as other pulse shapes, were used to drive the tubes. Properties studied in the analog mode include nonlinearity at high output currents, transient behavior upon gating, gate holdoff, dynamic range limitations because of light-induced noise, and the effect of dynode gating on tubes without a focus grid. Some of these properties were also studied in the photon counting mode, along with single photoelectron pulse shape and afterpulsing. A brief description of the laser radar technique of atmospheric measurements is included.

Hunt, W. H.↗

High background photon counting lidar

Photon counting with lidar returns is usually limited to low light levels, while wide dynamic range is achieved by counting for long times. The broad emission spectrum of inexpensive high-power semiconductor lasers makes receiver filters pass too much background light for traditional photon counting in daylight. Very high speed photon counting is possible, however, at more than 500 MHz which allows the construction of eyesafe lidar operating in the presence of bright clouds. Detector improvements are possible to count to 20 GHz producing a single shot dynamic range of ten decades.

Lentz, W. J.↗

High dynamic GPS receiver validation demonstration

The Validation Demonstration establishes that the high dynamic Global Positioning System (GPS) receiver concept developed at JPL meets the dynamic tracking requirements for range instrumentation of missiles and drones. It was demonstrated that the receiver can track the pseudorange and pseudorange rate of vehicles with acceleration in excess of 100 g and jerk in excess of 100 g/s, dynamics ten times more severe than specified for conventional High Dynamic GPS receivers. These results and analytic extensions to a complete system configuration establish that all range instrumentation requirements can be met. The receiver can be implemented in the 100 cu in volume required by all missiles and drones, and is ideally suited for transdigitizer or translator applications.

Hurd, W. J.↗