Search NASA⌕ Search

SEARCH · Search NASA

Results for “Human body”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Sensor Integrated Pilot Mask for On-Board, Real-Time, Monitoring of Pilot Breathing Gas

A pilot's job is unique in the demands it places on the human body, and many conditions can seriously affect pilot performance, threatening mission completion and pilot safety. The gas in a flight mask contains key indicators of the pilot's physiological state, including oxygen inhaled and carbon dioxide exhaled, which can signal hypoxia, hyperoxia, hypocapnia, and hypercapnia. A fiber optic-based sensor system, integrated into the pilot mask, has been developed to monitor in real time, during flight, the pilot breathing gas levels. Monitoring the partial pressure of oxygen and carbon dioxide in the pilot mask supports real-time closed loop control of the on-board oxygen generation system, based on a direct reading of what the pilot is actually breathing. The pilot Mask Sensor (MASES) system incorporates luminescence sensors for pO2, pCO2, relative humidity, pressure, and temperature in a compact probe in the pilot mask; it is based on sensor technology developed for gas monitoring in space suit systems, in work supported by NASA under the Small Business Innovation Research program. Relevant requirements for the MASES system include sensor operation while wet, operation at reduced pressure, ability to withstand rapid decompression, operation in a pure oxygen atmosphere, low power consumption, a compact readout unit, and flexible miniature sensors; many of these requirements are shared with gas monitors in space suits. Data are presented from tests conducted with human subjects in an altitude chamber and in a centrifuge.

Delgado Alonso, Jesus↗

Latency and User Performance in Virtual Environments and Augmented Reality

System rendering latency has been recognized by senior researchers, such as Professor Fredrick Brooks of UNC (Turing Award 1999), as a major factor limiting the realism and utility of head-referenced displays systems. Latency has been shown to reduce the user's sense of immersion within a virtual environment, disturb user interaction with virtual objects, and to contribute to motion sickness during some simulation tasks. Latency, however, is not just an issue for external display systems since finite nerve conduction rates and variation in transduction times in the human body's sensors also pose problems for latency management within the nervous system. Some of the phenomena arising from the brain's handling of sensory asynchrony due to latency will be discussed as a prelude to consideration of the effects of latency in interactive displays. The causes and consequences of the erroneous movement that appears in displays due to latency will be illustrated with examples of the user performance impact provided by several experiments. These experiments will review the generality of user sensitivity to latency when users judge either object or environment stability. Hardware and signal processing countermeasures will also be discussed. In particular the tuning of a simple extrapolative predictive filter not using a dynamic movement model will be presented. Results show that it is possible to adjust this filter so that the appearance of some latencies may be hidden without the introduction of perceptual artifacts such as overshoot. Several examples of the effects of user performance will be illustrated by three-dimensional tracking and tracing tasks executed in virtual environments. These experiments demonstrate classic phenomena known from work on manual control and show the need for very responsive systems if they are indented to support precise manipulation. The practical benefits of removing interfering latencies from interactive systems will be emphasized with some classic final examples from surgical telerobotics, and human-computer interaction.

Ellis, Stephen R.↗

Computational Transport Modeling of High-Energy Neutrons Found in the Space Environment

The high charge and high energy (HZE) particle radiation environment in space interacts with spacecraft materials and the human body to create a population of neutrons encompassing a broad kinetic energy spectrum. As an HZE ion penetrates matter, there is an increasing chance of fragmentation as penetration depth increases. When an ion fragments, secondary neutrons are released with velocities up to that of the primary ion, giving some neutrons very long penetration ranges. These secondary neutrons have a high relative biological effectiveness, are difficult to effectively shield, and can cause more biological damage than the primary ions in some scenarios. Ground-based irradiation experiments that simulate the space radiation environment must account for this spectrum of neutrons. Using the Particle and Heavy Ion Transport Code System (PHITS), it is possible to simulate a neutron environment that is characteristic of that found in spaceflight. Considering neutron dosimetry, the focus lies on the broad spectrum of recoil protons that are produced in biological targets. In a biological target, dose at a certain penetration depth is primarily dependent upon recoil proton tracks. The PHITS code can be used to simulate a broad-energy neutron spectrum traversing biological targets, and it account for the recoil particle population. This project focuses on modeling a neutron beamline irradiation scenario for determining dose at increasing depth in water targets. Energy-deposition events and particle fluence can be simulated by establishing cross-sectional scoring routines at different depths in a target. This type of model is useful for correlating theoretical data with actual beamline radiobiology experiments. Other work exposed human fibroblast cells to a high-energy neutron source to study micronuclei induction in cells at increasing depth behind water shielding. Those findings provide supporting data describing dose vs. depth across a water-equivalent medium. This poster presents PHITS data suggesting an increase in dose, up to roughly 10 cm depth, followed by a continual decrease as neutrons come to a stop in the target.

Cox, Brad↗

Role of shielding in modulating the effects of solar particle events: Monte Carlo calculation of absorbed dose and DNA complex lesions in different organs

Distributions of absorbed dose and DNA clustered damage yields in various organs and tissues following the October 1989 solar particle event (SPE) were calculated by coupling the FLUKA Monte Carlo transport code with two anthropomorphic phantoms (a mathematical model and a voxel model), with the main aim of quantifying the role of the shielding features in modulating organ doses. The phantoms, which were assumed to be in deep space, were inserted into a shielding box of variable thickness and material and were irradiated with the proton spectra of the October 1989 event. Average numbers of DNA lesions per cell in different organs were calculated by adopting a technique already tested in previous works, consisting of integrating into "condensed-history" Monte Carlo transport codes--such as FLUKA--yields of radiobiological damage, either calculated with "event-by-event" track structure simulations, or taken from experimental works available in the literature. More specifically, the yields of "Complex Lesions" (or "CL", defined and calculated as a clustered DNA damage in a previous work) per unit dose and DNA mass (CL Gy-1 Da-1) due to the various beam components, including those derived from nuclear interactions with the shielding and the human body, were integrated in FLUKA. This provided spatial distributions of CL/cell yields in different organs, as well as distributions of absorbed doses. The contributions of primary protons and secondary hadrons were calculated separately, and the simulations were repeated for values of Al shielding thickness ranging between 1 and 20 g/cm2. Slight differences were found between the two phantom types. Skin and eye lenses were found to receive larger doses with respect to internal organs; however, shielding was more effective for skin and lenses. Secondary particles arising from nuclear interactions were found to have a minor role, although their relative contribution was found to be larger for the Complex Lesions than for the absorbed dose, due to their higher LET and thus higher biological effectiveness. c2004 COSPAR. Published by Elsevier Ltd. All rights reserved.

Non-NASA Center↗

Ultrasound in space

Physiology of the human body in space has been a major concern for space-faring nations since the beginning of the space era. Ultrasound (US) is one of the most cost effective and versatile forms of medical imaging. As such, its use in characterizing microgravity-induced changes in physiology is being realized. In addition to the use of US in related ground-based studies, equipment has also been modified to fly in space. This involves alteration to handle the stresses of launch and different power and cooling requirements. Study protocols also have been altered to accommodate the microgravity environment. Ultrasound studies to date have shown a pattern of adaptation to microgravity that includes changes in cardiac chamber sizes and vertebral spacing. Ultrasound has been and will continue to be an important component in the investigation of physiological and, possibly, pathologic changes occurring in space or as a result of spaceflight.

Review, Tutorial↗

Spacesuit and Mobility Performance Changes

The complex interactions between the human body and spacesuit lead to changes inmovement patterns and mobility performancesof the wearer. In general, factors including the geometric properties, such as shape and size, mechanical properties of the suit, and pressurization of the suit are known to be associated with altered movement patterns as compared to an unsuited human.However, their relative contributions have not been explicitly quantified from the mobility performance perspectives. The goal of this study wasthus to assessthe effects fromthe different types of mobility constraintconditions, namely by wearing either a 3D printed hard upper torso (HUT) assembly orfully pressurized spacesuit. The outcome was also compared against the unsuited motions. For this study, an xEMU (exploration Extravehicular Mobility Unit) suitwas considered, which is the next generation spacesuit developed by NASA. In each test condition, the subject was asked to move the arm and hand as prescribedfor different task types, and the corresponding body segment locations were recordedusing a 3D motion capture system. The following three tasks were performedand analyzed: 1) Outward one-handed reaches:the subject in a standing pose made sweeping motions with the extended right arm from the extreme end-to-end positions, including side-to-side at different elevations and top-to-bottom at different azimuths. 2) Outward two-handed reaches:similarto the previous task, howeverthe subject kept the hands together during the motions in order to assessthe areas that can be reached by both hands. 3) Inward one-handed reaches:the subject made right-hand reach motions to the surface of the HUT.The hand traces collected from each task were modeled by a template shape parametrically deformed with a radial basis function. This process enabled foran abstraction of the hand traces into a smooth surface envelope representing the maximally reachable area of the test subject, of which the shapes and sizes were compared across the different test conditions. The preliminary analysis has shown that theoverall size of reachenvelopes decreases in a pressurized suit compared to 3D printed mockup HUT and unsuited conditions. The specific shape of the envelopes, which were determined by the reachable and unreachable zones, alsovary with the testconditions, and the differences werepronounced with the inward reaches to the HUT surface. The latter observation ispotentially relatedto the increased demandfor shoulder and elbow flexions.Overcomingthe resistance from the pressurizedsoft goods and mechanical constraints of the shoulder assemblywas seen to be associated with the difference in motion patterns between the suited and unsuited conditions. Overall, the information quantified from this study is expected to provide structured metrics for spacesuit mobility, which can improve design optimization and human-system integration.

K Han Kim↗

Application of high-performance computing to numerical simulation of human movement

We have examined the feasibility of using massively-parallel and vector-processing supercomputers to solve large-scale optimization problems for human movement. Specifically, we compared the computational expense of determining the optimal controls for the single support phase of gait using a conventional serial machine (SGI Iris 4D25), a MIMD parallel machine (Intel iPSC/860), and a parallel-vector-processing machine (Cray Y-MP 8/864). With the human body modeled as a 14 degree-of-freedom linkage actuated by 46 musculotendinous units, computation of the optimal controls for gait could take up to 3 months of CPU time on the Iris. Both the Cray and the Intel are able to reduce this time to practical levels. The optimal solution for gait can be found with about 77 hours of CPU on the Cray and with about 88 hours of CPU on the Intel. Although the overall speeds of the Cray and the Intel were found to be similar, the unique capabilities of each machine are better suited to different portions of the computational algorithm used. The Intel was best suited to computing the derivatives of the performance criterion and the constraints whereas the Cray was best suited to parameter optimization of the controls. These results suggest that the ideal computer architecture for solving very large-scale optimal control problems is a hybrid system in which a vector-processing machine is integrated into the communication network of a MIMD parallel machine.

NASA Discipline Musculoskeletal↗

Dose equivalent near the bone-soft tissue interface from nuclear fragments produced by high-energy protons

During manned space missions, high-energy nucleons of cosmic and solar origin collide with atomic nuclei of the human body and produce a broad linear energy transfer spectrum of secondary particles, called target fragments. These nuclear fragments are often more biologically harmful than the direct ionization of the incident nucleon. That these secondary particles increase tissue absorbed dose in regions adjacent to the bone-soft tissue interface was demonstrated in a previous publication. To assess radiological risks to tissue near the bone-soft tissue interface, a computer transport model for nuclear fragments produced by high energy nucleons was used in this study to calculate integral linear energy transfer spectra and dose equivalents resulting from nuclear collisions of 1-GeV protons transversing bone and red bone marrow. In terms of dose equivalent averaged over trabecular bone marrow, target fragments emitted from interactions in both tissues are predicted to be at least as important as the direct ionization of the primary protons-twice as important, if recently recommended radiation weighting factors and "worst-case" geometry are used. The use of conventional dosimetry (absorbed dose weighted by aa linear energy transfer-dependent quality factor) as an appropriate framework for predicting risk from low fluences of high-linear energy transfer target fragments is discussed.

NASA Discipline Number 45-10↗

Baroreflex dysfunction induced by microgravity: potential relevance to postflight orthostatic intolerance

Microgravity imposes adaptive changes in the human body. This review focuses on the changes in baroreflex function produced by actual spaceflight, or by experimental models that simulate microgravity, e.g., bed rest. We will analyze separately studies involving baroreflexes arising from carotid sinus and aortic arch afferents ("high-pressure baroreceptors"), and cardiopulmonary afferents ("low-pressure receptors"). Studies from unrelated laboratories using different techniques have concluded that actual or simulated exposure to microgravity reduces baroreflex function arising from carotid sinus afferents ("carotic-cardiac baroreflex"). The techniques used to study the carotid-cardiac baroreflex, using neck suction and compression to simulate changes in blood pressure, have been extensively validated. In contrast, it is more difficult to selectively study aortic arch or cardiopulmonary baroreceptors. Nonetheless, studies that have examined these baroreceptors suggest that microgravity produces the opposite effect, ie, an increase in the gain of aortic arch and cardiopulmonary baroreflexes. Furthermore, most studies have focus on instantaneous changes in heart rate, which almost exclusively examines the vagal limb of the baroreflex. In comparison, there is limited information about the effect of microgravity on sympathetic function. A substantial proportion of subjects exposed to microgravity develop transient orthostatic intolerance. It has been proposed that alterations in baroreflex function play a role in the orthostatic intolerance induced by microgravity. The evidence in favor and against this hypothesis is reviewed.

manned↗

Novel shock absorber features varying yield strengths

A shock absorbent webbing of partially drawn synthetic strands is arranged in sections of varying density related to the varying mass of the human body. This is contoured to protect the body at points of contact, when subjected to large acceleration or deceleration forces.

Geier, D. J.↗

Ballistocardiography, a Bibliography <1877 - 1964<

The publication of this bibliography on Ballistocardiography, NASA SP-7021 (FAA AM 65-15) fulfills a long-standing requirement for a comprehensive and retrospective collection of references on a subject that is of particular interest to medical investigators and cardiovascular physiologists engaged in aerospace studies. Ballistocardiography is a technique for producing a graphical representation of repetitive motions of the human body arising from the sudden ejection of blood into the great vessels with each heart beat. Standard ballistocardiographic techniques are emphasized in the references included in the bibliography, but attention is also given to several related methods that are used to record these phenomena and to the equipment and instrumentation employed in such investigations. The format of the citations in NASA SP-7021 (FAA AM 65-15) was chosen to resemble, as closely as possible, the format that is now being used in the Index Medicwl published by the National Library of Medicine, except that English titles of foreign language articles appear in parentheses instead of in brackets as they do in Index Medicus. In each case, an attempt was made to identify the language of the article, or the place of publication of the foreign language journal. Since the citations were gathered over a period of years and occasionally from sources which do not appear in standard indexes, complete information was not always available. Citations are arranged alphabetically by personal author. In a large measure, the comprehensivenes of this collection of references is due to information obtained from card files compiled and maintained by Dr. William R. Scarborough of the Georgetown Clinical Research Institute, Office of Aviation Medicine, FAA, supplemented by the private collections of Drs. Isaac Starr, Abraham Noordergraaf, and John L. Nickerson. Selection and preparation of individual references and general editing of the material was done by Dr. Scarborough, who received valuable assistance from Mrs. Claire Tedesco of the Medical Library Branch of the FAA Library. Final compilation and printing were completed under the supervision of NASA.

AEROSPACE MEDICINE↗

Optimizations of Human Restraint Systems for Short-Period Acceleration

A restraint system's main function is to restrain its occupant when his vehicle is subjected to acceleration. If the restraint system is rigid and well-fitting (to eliminate slack) then it will transmit the vehicle acceleration to its occupant without modifying it in any way. Few present-day restraint systems are stiff enough to give this one-to-one transmission characteristic, and depending upon their dynamic characteristics and the nature of the vehicle's acceleration-time history, they will either magnify or attenuate the acceleration. Obviously an optimum restraint system will give maximum attenuation of an input acceleration. In the general case of an arbitrary acceleration input, a computer must be used to determine the optimum dynamic characteristics for the restraint system. Analytical solutions can be obtained for certain simple cases, however, and these cases are considered in this paper, after the concept of dynamic models of the human body is introduced. The paper concludes with a description of an analog computer specially developed for the Air Force to handle completely general mechanical restraint optimization programs of this type, where the acceleration input may be any arbitrary function of time.

Payne, P. R.↗

Heparin insolubilized with crosslinking agent

New plastic compositions, involving the systhesis of a polymeric system containing heparin insolubilized with crosslinking agents, show appreciable promise in human body implant technology.

Rembaum, A.↗

Electric current

Physiological effects of electricity on human body and its organs, and tolerance limits to electric currents

Finkelstein, S.↗