Simulating the Power Noise Response due to Voiding in the NBSR during the February 3rd Incident
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Abstract not provided.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
A photon-number-resolving detector comprises a detection element, an ohmmeter, and a hardware logic component. The detection element can be formed from a Weyl or Dirac semimetal. Electrons of the detection element are characterized by a surface state that exhibits a Dirac cone and a bulk superconducting state that exhibits a bandgap. When photons having energies less than the bandgap of the bulk superconducting state impinges on the detection element, the photons can be absorbed by electrons of the detection element that are characterized by the surface state. The ohmmeter outputs resistance data indicative of an electrical resistance of the detection element while the photons impinge on the detection element. The hardware logic component can determine, based upon the resistance data, a number of the photons that are absorbed by the surface state electrons of the detection element.
• Background noise from ionizing decay poses challenges for MKIDs due to their sensitivity to small energy depositions. • Our group bakes the MKID housing lid in radon to study effects of alphas from daughter isotopes in the decay chain. • The impact of alpha particles on the chip depends on their energy, making their distribution key to characterizing and reducing noise in superconducting quantum devices.
Superconducting quantum devices, such as microwave kinetic inductance detectors (MKIDs), are highly sensitive instruments used in quantum computing and advanced sensing technologies. However, their extreme sensitivity also makes them vulnerable to background noise from natural sources like radiation. One significant contributor to this noise is alpha particles emitted by 210Po, a radon decay daughter that accumulates on surfaces near the detector. This project investigates how alpha particles emitted from 210Po interact with MKID chips. These particles can deposit energy on the detector surface, disrupting its operation and generating false signals. Understanding the energy and behavior of these particles is crucial for improving the design and reliability of quantum devices. To explore this, we first modeled the decay chain starting from 210Pb to 210Po using differential equations. This allowed us to predict how the activity of alpha-emitting isotopes changes over time, reaching a steady state after about two years. Next, we simulated alpha particle interactions with the MKID chip using the Geant4 software toolkit. We built a detailed computer model of the detector housing, including the copper lid where alpha particles originate, the silicon chip, and a thin aluminum sensor layer. Alpha particles were emitted isotropically from just beneath the copper lid’s surface, mimicking natural decay conditions. The simulation tracked how these particles deposit energy on the chip, generating electron-hole pairs and phonons. The results provide insight into the behavior of the resultant electron-hole pairs and phonons, giving us a clear understanding of the energy deposition distribution on the chip. This work supports efforts to mitigate background noise in superconducting sensors, advancing their use in quantum computing and sensitive physics experiments.
This presentation discusses the differences between information systems (IT) and operational systems (OT) and why that difference is important in the context of cybersecurity for the energy sector.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Although the prompt fission neutron spectrum (PFNS) is an essential component of neutron-driven systems that has been measured for decades, there are still multiple glaring unknowns regarding the PFNS of major actinides in the fission neutron incident energy range, specifically with regard to multichance fission and pre-equilibrium neutron emission processes. The only impactful experimental 239 Pu PFNS measurements included in recent nuclear data evaluations were measured over a limited outgoing neutron energy range at thermal and 1.5-MeV average incident neutron energy, while other potentially impactful measurements have been shown to contain errors that resulted in either large uncertainty increases or in complete exclusion from nuclear data evaluation. Here, we report a measurement of the 239 Pu PFNS over a wide range of incident neutron energy (1–20 MeV) and three orders of magnitude in outgoing neutron energy (0.01–10 MeV) resulting from the Chi-Nu experiment at the Los Alamos Neutron Science Center. These results are the combination of separate PFNS measurements in the same experimental area, one using a Li-glass and the other a liquid scintillator detector array. Covariances between all PFNS data points from each detector and within each incident energy range were generated between all other data in both detector arrays and within all other incident neutron energy bins, yielding a single covariance matrix for all 1300 PFNS data points reported here. These covariances are based on a thorough assessment of systematic bias and uncertainties associated with the measurement, PFNS extraction technique, combination of data from each detector type, and other aspects of the analysis. The existence of covariances between PFNS data points in different incident neutron energy ranges yielded covariances between average PFNS energy values at each incident energy to be reported here as well, which allowed for firm statements to be made regarding a shape of a purely experimental mean PFNS energy trend for the first time. Although minor PFNS shape differences exist between the results reported here and recent nuclear data evaluations, the ENDF/B-VIII.0 and JEFF-3.3 PFNS evaluations agree reasonably well with the present results from 1-to 10-MeV incident neutron energy, which spans the well-measured 1.5-MeV incident neutron energy PFNS from Lestone and Shores as well as the onset of second-chance fission. However, while the pre-equilibrium component of the PFNS above 12-MeV incident neutron energy roughly agrees in position and magnitude with ENDF/B-VIII.0 and JEFF-3.3, clear differences relating to the relative magnitude of third-chance fission PFNS features are present in the PFNS shape and in the mean PFNS energy trends.
The utilities systems that encompass the Y-12 National Security Complex are an integral part of the entire campus, and are essential to maintaining critical mission focus for the site. Although the utilities systems each differ in function, the central production and distribution model creates a common thread on which each system is run. Several incidents in FY 2018 and FY 2019 documented a lack of overall systems control and highlighted the need to create a better command system that could maintain system availability and decrease possible impacts to the surrounding environment. An initial system was started in September of 2019 to better control mechanical utility distribution systems. The measurement of the system can be modeled against a standard command and control related incident. The corresponding work hours from a typical control-related incident were used as key component to this system model. System effectiveness is modeled against utility’s incidents that demonstrate a loss of command and control. The increased simulations of the model also document control can only be effectively contained within the stated time (3-5 years) by yielding more engineers to complete alignments, or drastically reducing the amount of time for alignments. The total control points of the model document a clear correlation between alignments, control points, and the amount of man-hours per incident. Current data shows that actual incident man-hours (1.88 manhours/ incident since initial system implementation) are near expected incident man-hours (1.81 manhours/ incident) with command and control for October 2021, which documents a 33.3% reduction in man-hours/incident since initial system implementation. A conclusion can be drawn that focus on increasing the amount of controlled points in the system can reduce incidents and the decrease the amount of non-value added work to employee’s day-to-day lives, while also achieving a culture that enhances and sustains utilities reliability.
Abstract Background Vitiligo is an autoimmune skin disorder characterized by depigmented patches of skin, which can have significant psychological impacts. Objectives To estimate the lifetime incidence of vitiligo, overall, by ethnicity and across other sociodemographic subgroups, and to investigate the impacts of vitiligo on mental health, work and healthcare utilization. Methods Incident cases of vitiligo were identified in the Optimum Patient Care Database of primary care records in the UK between 1 January 2004 and 31 December 2020. The lifetime incidence of vitiligo was estimated at age 80 years using modified time-to-event models with age as the timescale, overall and stratified by ethnicity, sex and deprivation. Depression, anxiety, sleep disturbance, healthcare utilization and work-related outcomes were assessed in the 2 years after vitiligo diagnosis and compared with matched controls without vitiligo. The study protocol for this retrospective observational study was registered with ClinicalTrials.gov (NCT06097494). Results In total, 9460 adults and children were newly diagnosed with vitiligo during the study period. The overall cumulative lifetime incidence was 0.92% at 80 years of age [95% confidence interval (CI) 0.90–0.94]. Cumulative incidence was similar in female (0.94%, 95% CI 0.92–0.97) and male patients (0.89%, 95% CI 0.86–0.92). There were substantial differences in lifetime incidence across ethnic groups, listed by Office for National Statistics criteria [Asian 3.58% (95% CI 3.38–3.78); Black 2.18% (95% CI 1.85–2.50); Mixed/multiple 2.03% (95% CI 1.58–2.47); Other 1.05% (95% CI 0.94–1.17); and White 0.73% (95% CI 0.71–0.76)]. Compared with matched controls, people with vitiligo had an increased risk of depression [adjusted odds ratio (aOR) 1.08, 95% CI 1.01–1.15]; anxiety (aOR 1.19, 95% CI 1.09–1.30); depression or anxiety (aOR 1.10, 95% CI 1.03–1.17); and sleep disturbance [adjusted hazard ratio (aHR) 1.15, 95% CI 1.02–1.31]. People with vitiligo also had a greater number of primary care encounters (adjusted incidence rate ratio 1.29, 95% CI 1.26–1.32) and a greater risk of time off work (aHR 1.15, 95% CI 1.06–1.24). There was little evidence of disparities in vitiligo-related impacts across ethnic subgroups. Conclusions Clinicians should be aware of the markedly increased incidence of vitiligo in people belonging to Asian, Black, Mixed/multiple and Other groups. The negative impact of vitiligo on mental health, work and healthcare utilization highlights the importance of monitoring people with vitiligo to identify those who need additional support.
Protecting hydroelectric plants from incidents that adversely impact their cyber-physical systems presents unique challenges due to the plants’ widely dispersed geographic locations and varied configurations as well as the relative nascent nature of the cyberattacks targeting these facilities. To help hydroelectric plants better respond to and mitigate cybersecurity incidents, this Department of Energy Water Power Technologies Office Cyber Comprehensive Reference list is to be used at a hydroelectric plant to quickly go to appropriate sources during the response and recovery of a cyber incident. In addition to this product, there are three other products meant to be distributed to a hydroelectric plant to assist in their cyber incident response and recovery. The first, a report on the processes of building a R&R flip book based on a large set of existing guidance. The second, a handy flip book meant to be distributed to hydroelectric plants to assist them during a cybersecurity incident occurring on a hydroelectic plant. And the third is a correlated alignment of the steps an hydroelectric plant operator would take for both a cyber incident as well as an emergency response process if the event rises to a cyber incident affecting the safe and reliable operations of a hydroelectric plant.
Tungsten (W) is the leading candidate for divertor target plates because of its high melting point (>3000°C), thermal conductivity, and ultimate tensile stress. While W and its alloys are the only solid materials that can survive the high heat fluxes incident on the divertor, W’s low-ductility high ductile-to-brittle transition temperature of ~600°C and relatively low recrystallization temperature (RT) of ~1300°C pose structural (among other) challenges. The objective of this work is to estimate the thermal-fluid and thermal-structural performance of the helium (He)-cooled T-tube divertor, which was originally developed by the Advanced Reactor Innovation and Evaluation Study (ARIES) using numerical simulations. Here, predictions of temperature distributions across the plasma-facing structural component and surface pressures from computational fluid dynamics simulations are used to determine stress distributions using commercial structural finite element modeling software over a range of fusion-relevant conditions. The maximum allowable incident heat fluxes are determined based on the temperature limits imposed by the ITER elastic Structural Design Criteria for In-vessel Components (SDC-IC) and the maximum RT over a range of He mass flow rates and presented in the form of performance design charts. Our recent work found that thermal- structural criteria accounting for the low ductility of W in a finger-type modular divertor constrain the maximum incident heat fluxes to values well below the ITER specifications, and those based on considering only the RT demonstrate that integrated thermal-fluid and elastic structural performance evaluation are required for accurate assessment of divertor performance. This novel analysis of the T-tube considers how nonuniform and transient incident heat fluxes affect its thermal-fluid and thermal-structural performance, as well as the effect of volumetric heating, which can be as great as 27% of the power incident on the divertor surface. The W tile of the T-tube, with its relatively large plasma-facing area of ~15 cm 2 , will likely experience significant spatial variations in incident heat flux. This work therefore assesses whether steady-state incident heat flux profiles with a peak of 10 MW/m 2 and maximum heat flux gradients of 200 MW/m 2 per m exceed the structural limits imposed by the ITER elastic SDC-IC and the maximum RT over a range of fusion-relevant conditions. The effect of transient heat fluxes typical of plasma detachment and reattachment from the target plate due, for example, to gas injection are also evaluated
Abstract Background There have been few studies on the relationship between oral status and postoperative pneumonia (POP) in patients with lung cancer, and whether improving their oral condition assists with a lower incidence of POP before lung cancer surgery remains controversial. This retrospective study was conducted by a stomatologist to assess the effect of controlling oral pathogenic bacteria of patients with lung cancer to prevent POP. Methods A total of 235 patients with lung cancer who underwent lobectomy by open thoracotomy between July 2015 and December 2018 were selected and given the choice of being in the experimental or control group. A total of 122 participants in the experimental group received professional oral plaque control, and 113 participants in the control group did not receive plaque control. All clinical data of participants in both groups were retrospectively studied to determine the incidence of POP at the thirtieth day of discharge from hospital. Results Eight in the experimental group and six in the control group were excluded from the study. It was found that four of 114 patients suffered from POP in the experimental group (incidence = 3.51%). A total of 17 of 107 patients in the control group had pulmonary infection (incidence = 15.89%). Odds ratio was 0.19. The incidence of POP in the experimental group was significantly lower than that of the control group ( P < 0.05). Conclusions Professional oral plaque control is associated with a lower incidence of POP following lung cancer surgery and is therefore a favorable factor for preventing POP, and should be carried out before the surgical treatment of lung cancer. Key points Professional oral plaque control was associated with a lower incidence of POP following lung cancer surgery, and it is recommended this should be carried out before the surgical treatment of lung cancer.
In the event of a major radiological incident or accident, the Federal Radiological Monitoring and Assessment Center (FRMAC) will coordinate the federal agencies that have various statutory responsibilities and/or capabilities for responding to such incidents (Ref. FRMAC10). The FRMAC is responsible for coordinating all environmental radiological monitoring, sampling, and assessment activities for the response. For less severe radiological incidents, elements of the Department of Energy (DOE) Consequence Management (CM) program, such as the CM Response Team (CMRT) or CM Home Team (CMHT) may be activated to provide similar support activities to regional or local response assets. This manual describes the roles and responsibilities of the Assessment Division of the FRMAC during a response to a radiological incident. Every effort will be made in this manual in accordance with the Implementation of the National Incident Management System (NIMS)/Incident Command System (ICS) in the Federal Radiological Monitoring and Assessment Center (FRMAC) – Emergency Phase (Ref. RSL07) to use terminology consistent with the National Incident Management System (NIMS) for Incident Command System (ICS) organizations, planning processes, and leadership positions (Ref. FEMA17). This manual also applies to smaller scale CM responses that may involve the CMRT or CMHT elements without the formation of a FRMAC. It details the concept of operations for the Assessment Division, including common tasks performed by the Division. This manual also describes the organizational structure of the Assessment Division and roles of the personnel within the Division.