Search NASA⌕ Search

SEARCH · Search NASA

Results for “INSTRUMENT & FEATURES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

DeepMerge – II. Building robust deep learning algorithms for merging galaxy identification across domains

In astronomy, neural networks are often trained on simulation data with the prospect of being used on telescope observations. Unfortunately, training a model on simulation data and then applying it to instrument data leads to a substantial and potentially even detrimental decrease in model accuracy on the new target dataset. Simulated and instrument data represent different data domains, and for an algorithm to work in both, domain-invariant learning is necessary. Here we employ domain adaptation techniques— Maximum Mean Discrepancy (MMD) as an additional transfer loss and Domain Adversarial Neural Networks (DANNs)— and demonstrate their viability to extract domain-invariant features within the astronomical context of classifying merging and non-merging galaxies. Additionally, we explore the use of Fisher loss and entropy minimization to enforce better in-domain class discriminability. We show that the addition of each domain adaptation technique improves the performance of a classifier when compared to conventional deep learning algorithms. We demonstrate this on two examples: between two Illustris-1 simulated datasets of distant merging galaxies, and between Illustris-1 simulated data of nearby merging galaxies and observed data from the Sloan Digital Sky Survey. The use of domain adaptation techniques in our experiments leads to an increase of target domain classification accuracy of up to ~20%. With further development, these techniques will allow astronomers to successfully implement neural network models trained on simulation data to efficiently detect and study astrophysical objects in current and future large-scale astronomical surveys.

galaxies: interactions↗

Annotation of DOM metabolomes with an ultrahigh resolution mass spectrometry molecular formula library

Current approaches to analyzing metabolomic data often rely on matching MS/MS fragmentation data to sparse libraries or databases. This approach results in limited identification of features, often with less than 10% of the dataset being annotated. A complementary approach is to assign molecular formula to features based on accurate mass measurements, but the platforms commonly used for metabolomics do not have the needed accuracy or resolving power to do this robustly, particularly for larger molecules. Using our newly modified analysis tool, CoreMS, we generated a library of molecular formula from pooled samples analyzed with LC-21T FT-ICR MS. This library successfully annotated approximately 53.2% of features identified from the exometabolome of marine diatom Phaeodactylum tricornutum – a nearly ten-fold increase over the 5.9% annotation rate achieved using a conventional MS/MS library matching approach. Using this FT-ICR MS library approach, we were able to differentiate differences in the exometabolome of P. tricornutum in iron replete and iron limited conditions, with 668 metabolites being differentially expressed (p < 0.05, 2 x intensity difference) under these conditions. The traditional MS/MS fragmentation-based annotation approach only annotated 61 of these metabolites, while our novel pipeline annotated 450 metabolites and revealed 12 metabolites that were significantly more abundant under low iron conditions. Our results demonstrate the utility of ultrahigh resolution mass spectrometry for generating more comprehensive and confident molecular annotations.

21T-FTICR-MS, CoreMS↗

Application of Flex-QA Arrays in HTS Magnet Testing

Flexible PCB quench antennas have been very useful in providing high-quality high-resolution data in low temperature superconducting magnet tests. Similar multi-sensor arrays have been employed recently to cover a high temperature superconductor magnet tested at FNAL. In the present work, data taking conditions and magnet features to support the analysis framework are discussed. Then observations made during complete magnet powering cycles are described and analysis of quench antenna data are presented. Based on results, improvements to instrumentation and data taking are debated. Views on the future of flexible quench antenna sensors for HTS magnet diagnostics and operational support are shared.

43 PARTICLE ACCELERATORS↗

Application of Flex-QA Arrays in HTS Magnet Testing

Flexible PCB quench antennas have been very useful in providing high-quality high-resolution data in low temperature superconducting magnet tests. Similar multi-sensor arrays have been employed recently to cover a high temperature superconductor magnet tested at FNAL. In the present work, data taking conditions and magnet features to support the analysis framework are discussed. Then observations made during complete magnet powering cycles are described and analysis of quench antenna data are presented. Based on results, improvements to instrumentation and data taking are debated. Views on the future of flexible quench antenna sensors for HTS magnet diagnostics and operational support are shared.

Stoynev, S.↗

Corundum Discovered by SuperCam and the Perseverance Rover at Jezero Crater, Mars

Minerals provide clues to the type of geologic environments in which they form. The primary types of minerals that have been identified on Mars indicate a history dominated by volcanism followed by interaction with water. However, other minerals are sometimes found. Here we present results from the SuperCam instrument on the Perseverance rover in which the mineral corundum (α-Al2O3) has been identified using a technique called time-resolved luminescence spectroscopy. Corundum has a unique light-emitting (luminescence) feature based on two well-known peaks as well as the time it takes for this light to fade after being excited by a laser, which is referred to as the lifetime. Corundum forms in specific environments that are enriched in aluminum and depleted in silicon and have been subjected to high temperature and pressure. Such places include deep subsurface magmas or shallower locations that have been exposed to high temperature through tectonic processes or meteorite impacts. Given their small size, association with a mineral called plagioclase, and location on the heavily impacted crater rim, we propose that these corundum minerals formed through impact processes.

58 GEOSCIENCES↗

Register-Like Storage Block Used as Histograms, Cluster Buffers, and Hough Transform Accumulators for HEP Trigger Systems

In high energy physics experiment trigger systems, block memories are utilized for various purposes, especially in binned searching algorithms. In these algorithms, the storages are demanded to perform like a large set of registers. The writing and reading operation must be performed in single clock cycle and once an event is processed, the memory must be globally reset. These demands can be fulfilled with registers but the cost of using registers for large memory is unaffordable. Another common requirement is the boundary coverage feature during reading process. Additionally, when a memory bin is addressed, the stored contents in the addressed bin and its neighboring bin must be output simultaneously. In this paper, a register-like block storage design scheme is described, which allows updating memory locations in single clock cycle, reading two adjacent bins, and effectively refreshing entire memory within a single clock. The implementation and test results are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Black carbon aerosol number and mass concentration measurements by picosecond short-range elastic backscatter lidar

Abstract Black carbon aerosol emissions are recognized as contributors to global warming and air pollution. There remains, however, a lack of techniques to remotely measure black carbon aerosol particles with high range and time resolution. This article presents a direct and contact-free remote technique to estimate the black carbon aerosol number and mass concentration at a few meters from the emission source. This is done using the Colibri instrument based on a novel technique, referred to here as Picosecond Short-Range Elastic Backscatter Lidar (PSR-EBL). To address the complexity of retrieving lidar products at short measurement ranges, we apply a forward inversion method featuring radiometric lidar calibration. Our method is based on an extension of a well-established light-scattering model, the Rayleigh–Debye–Gans for Fractal-Aggregates (RDG-FA) theory, which computes an analytical expression of lidar parameters. These parameters are the backscattering cross-sections and the lidar ratio for black carbon fractal aggregates. Using a small-scale Jet A-1 kerosene pool fire, we demonstrate the ability of the technique to quantify the aerosol number and mass concentration with centimetre range-resolution and millisecond time-resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear Safety [Vol. 30, No. 1, January-March 1989]

Nuclear Safety is a review journal that covers significant developments in the field of nuclear safety. Its scope includes the analysis and control of hazards associated with nuclear energy, operations involving fissionable materials, and the products of nuclear fission and their effects on the environment. Primary emphasis is on safety in reactor design, construction, and operation; however, the safety aspects of the entire fuel cycle, including fuel fabrication, spent-fuel processing, nuclear waste disposal, handling of radioisotopes, and environmental effects of these operations, are also treated. Table of Contents for this issue follows. GENERAL SAFETY CONSIDERATIONS: 1 International Conference on Thermal Reactor Safety: NUCSAFE 88 by A. P. Malinauskas and J. G. Pruett; ACCIDENT ANALYSIS: 18 Chernobyl Today: State of Research by A. Yu. Gagarinskii; CONTROL AND INSTRUMENTATION: 23 Problems Associated with Routine In-Plant Radioactive Effluent Monitoring Systems at U.S. Light-Water Reactors by Barry G. Wahlig, David M. Walker, Mahmoud R. Ghavi, and John M. Palms; DESIGN FEATURES: 34 Twentieth DOE/NRC Nuclear Air-Cleaning Conference by R. R. Bellamy, D. W. Moeller, and M. W. First, 46 Design Options for the Core Support Structure for Liquid-Metal-Cooled Reactor Plants by J. P. Burelbach, W. J. Kann, J. G. Saiveau, and R. W. Seidensticker; ENVIRONMENTAL EFFECTS: 53 The Radiological Consequences of the Chernobyl Accident by L. V. Konstantinov and A. J. González; WASTE AND SPENT FUEL MANAGEMENT: 70 Activities Related to Waste Management Compiled by E. G. Silver; OPERATING EXPERIENCES: 80 Fuel Performance Annual Report for 1986 by W. J. Bailey, 103 Safety Considerations Related to 12-Hour Shift Schedules by S. Gould, 105 Reactor Shutdown Experience Compiled by J. W. Cletcher, 108 Operating U.S. Power Reactors Compiled by E. G. Silver; RECENT DEVELOPMENTS: 130 General Administrative Activities Compiled by E. G. Silver, 140 Reports, Standards, and Safety Guides by D. S. Queener, 145 Status of Power-Reactor Licensing Activities Compiled by E. G. Silver, 153 Proposed Rule Changes as of Sept. 30, 1988; ANNOUNCEMENTS: 69 Northwestern University Short Course on Radiation Safety, 79 International Seminar on Fission Product Transport Processes in Reactor Accidents, 129 Harvard School of Public Health Offers Short Courses, 152 MIT Offers Summer Short Courses on Reactor Safety and Nodal Analysis, 152 Seminar on Use of PCs in Probabilistic Safety Analysis, 157 The Authors, 160 Indexes to Nuclear Safety, Volume 29.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Random Forest Optimization for Radionuclide Identification

Radionuclide identification through gamma-ray spectroscopy is an indispensable tool in combatting the illicit smuggling of nuclear material. The radionuclide identification devices used in the field need to provide ready-made answers to non-experts, and therefore require sophisticated algorithms that can interpret the underlying data. We investigated the Random Forest classifier as a tool for identifying the radionuclide that is consistent with the data. We were provided with training and validations data sets and used them to optimize the two hyperparameters of the classifiers: maximum features required, and minimum samples used to split each node. The F1 score, a harmonic mean of precision and recall, was used to evaluate the performance of each built classifier. We found the optimal performance with minimum samples of 5 and maximum features of 50, with the F1 score of 0.95.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Geant4 Material Definition

In Geant4, materials are defined using elements (G4Element) and isotopes (G4Isotope), supporting both single-element compositions and multi-element molecules or mixtures (by mass fraction). Each material is characterized by a mandatory density condition and optional parameters, such as state, temperature, and pressure. To simplify material definition and ensure accuracy, the G4NistManager is recommended for retrieving elements and materials from the NIST Material Database. These features make material specification in Geant4 flexible, efficient and consistent for describing complex detector geometry descriptions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Data-Driven Cyber-Attack Detection for PV Farms via Time-Frequency Domain Features

The internetworking of grid-connected power electronics converters (PECs) in photovoltaic (PV) farms has inevitably expanded the cyber-attack surfaces. Here this paper presents a comprehensive study on cyber-attack detection and diagnosis for PEC-enabled PV farms via single waveform sensor to distinguish between normal conditions, open-circuit faults, short-circuit faults, and cyber-attacks. To our knowledge, this has not been attempted before. Firstly, we propose frequency-domain magnitude-based residuals to identify short-circuit faults and a time-domain mean current vector-based feature to distinguish open-circuit faults from other threats. These features can fully reflect the specific physical characteristics of PV farms during threat duration. Secondly, unlike micro phasor measurement units (µPMU) and raw electric waveform-based methods, the proposed innovative features can address novel cyber-attacks that are excluded from the training process. Thirdly, an online hardware-in-the-loop (HIL) testbed using the OPAL-RT real-time digital simulator has verified the effectiveness. The monitoring system runs in real-time while using HIL as an operational solar farm and a National Instruments (NI) data acquisition card as the electric waveform sensor at the point of coupling.

42 ENGINEERING↗

Nuclear Safety [Vol. 30, No. 1, January-March 1989]

Nuclear Safety is a review journal that covers significant developments in the field of nuclear safety. Its scope includes the analysis and control of hazards associated with nuclear energy, operations involving fissionable materials, and the products of nuclear fission and their effects on the environment. Primary emphasis is on safety in reactor design, construction, and operation; however, the safety aspects of the entire fuel cycle, including fuel fabrication, spent-fuel processing, nuclear waste disposal, handling of radioisotopes, and environmental effects of these operations, are also treated. Table of Contents for this issue follows. GENERAL SAFETY CONSIDERATIONS: 1 International Conference on Thermal Reactor Safety: NUCSAFE 88 by A. P. Malinauskas and J. G. Pruett; ACCIDENT ANALYSIS: 18 Chernobyl Today: State of Research by A. Yu. Gagarinskii; CONTROL AND INSTRUMENTATION: 23 Problems Associated with Routine In-Plant Radioactive Effluent Monitoring Systems at U.S. Light-Water Reactors by Barry G. Wahlig, David M. Walker, Mahmoud R. Ghavi, and John M. Palms; DESIGN FEATURES: 34 Twentieth DOE/NRC Nuclear Air-Cleaning Conference by R. R. Bellamy, D. W. Moeller, and M. W. First, 46 Design Options for the Core Support Structure for Liquid-Metal-Cooled Reactor Plants by J. P. Burelbach, W. J. Kann, J. G. Saiveau, and R. W. Seidensticker; ENVIRONMENTAL EFFECTS: 53 The Radiological Consequences of the Chernobyl Accident by L. V. Konstantinov and A. J. González; WASTE AND SPENT FUEL MANAGEMENT: 70 Activities Related to Waste Management Compiled by E. G. Silver; OPERATING EXPERIENCES: 80 Fuel Performance Annual Report for 1986 by W. J. Bailey, 103 Safety Considerations Related to 12-Hour Shift Schedules by S. Gould, 105 Reactor Shutdown Experience Compiled by J. W. Cletcher, 108 Operating U.S. Power Reactors Compiled by E. G. Silver; RECENT DEVELOPMENTS: 130 General Administrative Activities Compiled by E. G. Silver, 140 Reports, Standards, and Safety Guides by D. S. Queener, 145 Status of Power-Reactor Licensing Activities Compiled by E. G. Silver, 153 Proposed Rule Changes as of Sept. 30, 1988; ANNOUNCEMENTS: 69 Northwestern University Short Course on Radiation Safety, 79 International Seminar on Fission Product Transport Processes in Reactor Accidents, 129 Harvard School of Public Health Offers Short Courses, 152 MIT Offers Summer Short Courses on Reactor Safety and Nodal Analysis, 152 Seminar on Use of PCs in Probabilistic Safety Analysis, 157 The Authors, 160 Indexes to Nuclear Safety, Volume 29.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Close Observation of Hydraulic Fracturing at EGS Collab Experiment 1: Fracture Trajectory, Microseismic Interpretations, and the Role of Natural Fractures

Abstract Despite the wide application of hydraulic fracturing in enhanced geothermal system (EGS) development and unconventional hydrocarbon production, our understanding of the many factors affecting the propagation of hydraulic fractures has relied on circumstantial evidence. This is partly due to the scarcity of direct observations in the subsurface. The EGS Collab project attempts to address these issues in the context of EGS research by performing intermediate‐scale (∼10 m) hydraulic stimulation experiments in a thoroughly characterized and heavily instrumented underground testbed. This paper analyzes the data collected from the first suite of hydraulic fracturing tests in this testbed, consisting of seven stimulation episodes. High‐quality microseismic data delineate five planar features very clearly. Combining fracture‐wellbore intersection observations from distributed temperature sensing (DTS) and visual observations from an open‐hole well, as well as prior in‐situ stress measurements, we conclude with high certainty that the four larger planes were hydraulic fractures. The growth of the hydraulic fractures was temporarily halted by a prominent, open natural fracture in the testbed but they eventually crossed and slightly reoriented under continued stimulation. Mineral‐filled (i.e., healed) natural fractures, though prevalent in the testbed, did not have perceivable effects on hydraulic fracture propagation. The high‐quality, mutually corroborating data sets allowed conclusions to be drawn with high confidence and attests to the advantage of intermediate‐scale experiments in subsurface research.

58 GEOSCIENCES↗

The Hubble Space Telescope's Near-UV and Optical Transmission Spectrum of Earth as an Exoplanet

We observed the 2019 January total lunar eclipse with the Hubble Space Telescope’s STIS spectrograph to obtain the first near-UV (1700–3200 Å) observation of Earth as a transiting exoplanet. The observatories and instruments that will be able to perform transmission spectroscopy of exo-Earths are beginning to be planned, and characterizing the transmission spectrum of Earth is vital to ensuring that key spectral features (e.g., ozone, or O{sub 3}) are appropriately captured in mission concept studies. O{sub 3} is photochemically produced from O{sub 2}, a product of the dominant metabolism on Earth today, and it will be sought in future observations as critical evidence for life on exoplanets. Ground-based observations of lunar eclipses have provided the Earth’s transmission spectrum at optical and near-IR wavelengths, but the strongest O{sub 3} signatures are in the near-UV. We describe the observations and methods used to extract a transmission spectrum from Hubble lunar eclipse spectra, and identify spectral features of O{sub 3} and Rayleigh scattering in the 3000–5500 Å region in Earth’s transmission spectrum by comparing to Earth models that include refraction effects in the terrestrial atmosphere during a lunar eclipse. Our near-UV spectra are featureless, a consequence of missing the narrow time span during the eclipse when near-UV sunlight is not completely attenuated through Earth’s atmosphere due to extremely strong O{sub 3} absorption and when sunlight is transmitted to the lunar surface at altitudes where it passes through the O{sub 3} layer rather than above it.

79 ASTRONOMY AND ASTROPHYSICS↗

Analysis of liquid petroleum using a laser-induced breakdown spectroscopy instrument

Here, a prototype analyzer for the direct LIBS analysis of nebulized liquid samples was developed and tested, particularly for the analysis of petroleum, organic solvents and aqueous solutions. The LIBS analyzer requires about 750 µl of liquid sample, 1 liter of N 2 gas, and 10 s of the analysis time to record 100 spectra. The limits of detection in oil and solvent are as low as 0.01–0.04 ppm for Li, Mg, and Cu. They increase for the difficult elements, such as Pb and Hg (7-10 ppm), Cl (250 ppm), and S (~0.7%). The relative standard deviation of measuring 100 ppm vanadium in oil and solvent was 1.5%. The LIBS detection limits and repeatability are better than required by the standard method ASTM D5185 for the analysis of lubricating oils in ICP-OES. Several petroleum samples were analyzed by LIBS and the quantitative results for V, Ni, and Fe compared to the ICP-OES data. Light crude oils can be nebulized and analyzed directly. Medium crude oils require minimal dilution at least 1:1, otherwise errors of determination become large. Presumably, utilization of the internal standard and chemometrics can be useful to correct for the matrix effects. In addition to the trace element analysis, the LIBS prototype demonstrated ability to measure the hydrogen-to-carbon ratio in organic liquid samples. Several unidentified features were observed in the carbon spectrum. Their possible origin is discussed.

02 PETROLEUM↗

Strong-coupling quantum dot microscope

Here, we report the development and fabrication of a novel cryogenic instrument, a scanning quantum dot microscope (SQDM), capable of positioning a quantum dot to within tunneling range of a sample surface. The microscope is strong-coupling in the sense that electron wavefunctions in the quantum dot can directly overlap with electron wavefunctions in the sample, in contrast to probes based on electric-field coupling. The SQDM consists of a sharp glass probe with two asymmetric electrodes leading to an aluminum quantum dot at the apex. One electrode is capacitively coupled to the quantum dot, while the other lead is connected to the dot via a tunneling junction. A charge sensing circuit constructed from a high-electron-mobility transistor is attached to the capacitance lead to measure the charge state of the dot. The last key feature of the design is a tilted-apex geometry. This design feature, in conjunction with the capacitive sensing scheme, results in a robust quantum-dot probe capable of operating within angstrom distances of the sample surface while protecting the single tunnel junction responsible for electron transport onto the quantum dot. We demonstrate that our instrument can detect single-electron tunneling events and can also be operated as a standard scanning tunneling microscope capable of nanometer-scale resolution of the surface topography.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Combined Optical and Radio–Frequency Perspectives on the Time Evolution of Lightning Measured by the FORTE Satellite

We use a cluster feature data set for the Fast On-orbit Recording of Transient Events (FORTE) satellite that combines detections from its pixelated Lightning Locating System (LLS), photodiode detector (PDD) and Radio-Frequency (RF) instrumentation to generate statistics describing the frequency and timing of lightning events detected by each instrument during lightning flashes. Coincident observations from the same vantage point allow us to directly compare flash details that can be resolved by the wide Field of View (FOV) instruments relative to the pixelated LLS—whose design is based on NASA's Lightning Imaging Sensor. We find that both the PDD and RF system typically generate more detections than the lightning imager (mean: 1.5 PDD events per LLS group, 2 RF events per LLS group) from pulses that are either not sufficiently bright in the optical band (in the case of RF) or that lack the optical energy density (in the case of the PDD) required to trigger one of the pixels on the LLS imaging array. This includes additional activity before the first LLS group or after the final LLS group. These FORTE results demonstrate that certain lightning processes would be better resolved by wide-FOV optical and RF instruments than lightning imagers. Current/future space-based missions that use/plan to use similar instruments will improve our understanding of flash evolution by resolving details missed by lightning imagers.

47 OTHER INSTRUMENTATION↗

Generation of multiple attosecond sub-bursts in femtosecond pulse trains by long-wavelength driving lasers

High-order harmonics generated by a long intense femtosecond laser are known experimentally to create attosecond pulse trains (APTs). In the time domain, an APT consists of a sequence of sharp attosecond bursts that are equally separated by each half optical cycle. Here, in this work, we show that such well-known features can be modified when a longer wavelength driving laser is used. From our simulations, we show that multiple shorter attosecond sub-bursts exist in the femtosecond pulse train within each half optical cycle and the duration of each sub-burst scales approximately as $λ^{–2}_0$ with the driving laser wavelength λ 0 . We show that such sub-bursts can be found using quantitative rescattering model for harmonics generated from a single atom, and their origin is due to the interference of the quantum orbits from first two returns of the recombining electron. We further show that such sub-bursts can be phase matched under proper laser focusing condition and the position of the gas cell, thus, such new features should be observable experimentally.

47 OTHER INSTRUMENTATION↗