Search NASA⌕ Search

SEARCH · Search NASA

Results for “INSTRUMENTS - DRIFT INDICATORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

A survey of simulation and diagnostic techniques for hypersonic nonequilibrium flows

The possible means of simulating nonequilibrium reacting flows in hypersonic environments, and the required diagnostic techniques, are surveyed in two categories: bulk flow behavior and determination of chemical rate parameters. Flow visualization of shock shapes for validation of computational-fluid dynamic calculations is proposed. The facilities and the operating conditions necessary to produce the required nonequilibrium conditions, the suitable optical techniques, and their sensitivity requirements, are surveyed. Shock-tubes, shock-tunnels, and ballistic ranges in a wide range of sizes and strengths are found to be useful for this purpose, but severe sensitivity requirements are indicated for the optical instruments, which can be met only by using highly-collimated laser sources. Likewise, for the determination of chemical parameters, this paper summarizes the quantities that need to be determined, required facilities and their operating conditions, and the suitable diagnostic techniques and their performance requirements. Shock tubes of various strengths are found to be useful for this purpose. Vacuum ultraviolet absorption and fluorescence spectroscopy and coherent anti-Stokes Raman spectroscopy are found to be the techniques best suited for the measurements of the chemical data.

Sharma, Surendra P.↗

Flight simulation of a wide-body transport aircraft to evaluate MLS-RNAV procedures

In a collaborative effort between the Federal Aviation Administration (FAA) NASA and the U.S. Air Force, a piloted simulation was conducted to look at the issues involved with flying a large, wide-body aircraft in the airport terminal area using Microwave Landing System Area Navigation (MLS)-RNAV procedures. A variety of approach paths, departure paths, and holding patterns were evaluated during the course of the study for operational use, flight technical errors, and safety. In addition, several methods for driving the horizontal situation indicator and flight director instruments were investigated along with needle sensitivity. The ultimate goal of the simulation was to develop and verify candidate paths and procedures prior to flight tests conducted in 1986/87. Subject pilots for the simulation study were provided by the FAA, NASA, the U.S. Air Force, and the airline industry.

Branstetter, James R.↗

The ultraviolet spectrum of a dayside aurora - 530-1500 A

Observations by rocket-borne spectrometers of the high-latitude dayside aurora above Cape Perry, N.W.T. are reported. UV spectra of optical emissions produced by ambient precipitating particles are obtained in the 530-1500 A region, over a range of spectrometer line-of-sight orientations, from 100 km to the rocket apogee of 452 km. The spectrum below 1500 A is dominated by transitions from neutral and singly ionized atomic oxygen. N I, N II, and N2 emissions, which are prominent in day airglow and nighttime auroral spectra measured by the same instrumentation, are very weak, indicating energy from the dayside auroral particles is transferred to the atmosphere above most of the N2. Relative line strengths of O I and O II transitions in the high-latitude dayside aurora differ in comparison with either airglow or nighttime auroral observations.

Gentieu, E. P.↗

Retrieval of monthly rainfall indices from microwave radiometric measurements using probability distribution functions

An algorithm for the estimation of monthly rain totals for 5 deg cells over the ocean from histograms of SSM/I brightness temperatures has been developed. There are three novel features to this algorithm. First, it uses knowledge of the form of the rainfall intensity probability density function to augment the measurements. Second, a linear combination of the 19.35 and 22.235 GHz channels has been employed to reduce the impact of variability of water vapor. Third, an objective technique has been developed to estimate the rain layer thickness from the 19.35- and 22.235-GHz brightness temperature histograms. Comparison with climatologies and the GATE radar observations suggest that the estimates are reasonable in spite of not having a beam-filling correction. By-products of the retrievals indicate that the SSM/I instrument noise level and calibration stability are quite good.

Wilheit, Thomas T.↗

A lunar based solar observatory - Rationale and concepts

The rationale for a lunar solar observatory is described and the requirements for various candidate instruments are developed. The unique characteristics of the lunar surface, its stability, low seismicity, and long unobstructed paths make it an ideal site for a large, high performance optical telescope. The capabilities of such an instrument is used, as an example (1) for the science that might be achieved from the lunar surface, (2) to identify the magnitude of the instrumentation, and (3) to indicate the technologies that must be developed if such an observatory is to become a reality.

Davis, John M.↗

Novel approaches to the construction of miniaturized analytical instrumentation

This paper focuses on the design, construction, preliminary testing, and potential applications of three forms of miniaturized analytical instrumentation. The first is an optical fiber instrument for monitoring pH and other cations in aqueous solutions. The instrument couples chemically selective indicators that were immobilized at porous polymeric films with a hardware package that provides the excitation light source, required optical components, and detection and data processing hardware. The second is a new form of a piezoelectric mass sensor. The sensor was fabricated by the deposition of a thin (5.5 micron) film of piezoelectric aluminum nitride (AIN). The completed deposition process yields a thin film resonator (TFR) that is shaped as a 400 micron square and supports a standing bulk acoustic wave in a longitudinal mode at frequencies of approx. 1 GHz. Various deposition and vapor sorption studies indicate that the mass sensitivity of the TFR's rival those of the most sensitive mass sensors currently available, though offering such performance in a markedly smaller device. The third couples a novel form of liquid chromatography with microlithographic miniaturization techniques. The status of the miniaturization effort, the goal of which is to achieve chip-scale separations, is briefly discussed.

Porter, Marc D.↗

Simultaneous ROSAT/Ginga observations of 4U 1820-30

We have made simultaneous Ginga LAC and ROSAT PSPC observations of 4U 1820-30. The 685-s orbital light curves obtained with the two instruments are very similar, indicating that the energy dependence of the orbital modulation is small. Our measurements extend the baseline over which the period variations can be measured to 15 yr. The previous possibility, that the changes in the period are themselves periodic, with a period of about 8 yr, is no longer preferred over a constant P(dot). Over the interval 1976-91 the period has decreased, rather than increasing as predicted by the standard model for the orbital evolution of the binary. The average period derivative P(dot)/P was (-0.88 +/- 0.16) x 10 exp -7/yr, different by 11 sigma from the predicted value. Under the assumption that there are no intrinsic changes in the light curve that mimic a period change, we discuss three possible explanations.

Van Der Klis, M.↗

Novel approaches to the construction of miniaturized analytical instrumentation

This paper focuses on the design, construction, preliminary testing, and potential applications of three forms of miniaturized analytical instrumentation. The first is an optical fiber instrument for monitoring pH and other cations in aqueous solutions. The instrument couples chemically selective indicators that were immobilized at porous polymeric films with a hardware package that provides the excitation light source, required optical components, and detection and data processing hardware. The second is a new form of a piezoelectric mass sensor. The sensor was fabricated by the deposition of a thin (5.5 micron) film of piezoelectric aluminum nitride (AIN). The completed deposition process yields a thin film resonator (TFR) that is shaped as a 400 micron square and supports a standing bulk acoustic wave in a longitudinal mode at frequencies of approx. 1 GHz. Various deposition and vapor sorption studies indicate that the mass sensitivity of the TFR's rival those of the most sensitive mass sensors currently available, though offering such performance in a markedly smaller device. The third couples a novel form of liquid chromatography with microlithographic miniaturization techniques. The status of the miniaturization effort, the goal of which is to achieve chip-scale separations, is briefly discussed.

Porter, Marc D.↗

Pitot-static tubes for determining the velocity of air

On the occasion of the formulation of the rules for testing the efficiency of ventilators and compressors, experiments were instituted by the subcommittee on ventilators for the production of suitable tubes for velocity and pressure measurements.

AIR SPEED INDICATORS↗

An Object-Oriented Graphical User Interface for a Reusable Rocket Engine Intelligent Control System

An intelligent control system for reusable rocket engines under development at NASA Lewis Research Center requires a graphical user interface to allow observation of the closed-loop system in operation. The simulation testbed consists of a real-time engine simulation computer, a controls computer, and several auxiliary computers for diagnostics and coordination. The system is set up so that the simulation computer could be replaced by the real engine and the change would be transparent to the control system. Because of the hard real-time requirement of the control computer, putting a graphical user interface on it was not an option. Thus, a separate computer used strictly for the graphical user interface was warranted. An object-oriented LISP-based graphical user interface has been developed on a Texas Instruments Explorer 2+ to indicate the condition of the engine to the observer through plots, animation, interactive graphics, and text.

Litt, Jonathan S.↗

Intitialization, Conceptualization, and Application in the Generalized Fractional Calculus

This paper provides a formalized basis for initialization in the fractional calculus. The intent is to make the fractional calculus readily accessible to engineering and the sciences. A modified set of definitions for the fractional calculus is provided which formally include the effects of initialization. Conceptualizations of fractional derivatives and integrals are shown. Physical examples of the basic elements from electronics are presented along with examples from dynamics, material science, viscoelasticity, filtering, instrumentation, and electrochemistry to indicate the broad application of the theory and to demonstrate the use of the mathematics. The fundamental criteria for a generalized calculus established by Ross (1974) are shown to hold for the generalized fractional calculus under appropriate conditions. A new generalized form for the Laplace transform of the generalized differintegral is derived. The concept of a variable structure (order) differintegral is presented along with initial efforts toward meaningful definitions.

Lorenzo, Carl F.↗

Comparison of ScaRaB, GOES 8, Aircraft, and Surface Observations of the Absorption of Solar Radiation by Clouds

Data obtained by the Scanner for Radiation Budget (ScaRaB) instrument on the Meteor 3 satellite have been analyzed and compared to satellite (GOES 8), aircraft (Radiation Measurement System, RAMS), and surface (Baseline Solar Radiation Network (BSRN), Solar and Infrared Observations System (SIROS), and RAMS) measurements of irradiance obtained during the Atmospheric Radiation Measurements Enhanced Shortwave Experiment (ARESE). It is found that the ScaRaB data covering the period from March 1994 to February 1995 (the instrument's operational lifetime) indicate excess absorption of solar radiation by the cloudy atmosphere in agreement with previous aircraft, surface, and GOES 8 results. The full ScaRaB data set combined with BSRN and SIROS surface observations gives an average all-sky absorptance of 0.28. The GOES 8 data set combined with RAMS surface observations gives an average all-sky absorptance of 0.26. The aircraft data set (RAMS) gives a mean all-sky absorptance of 0.24 (for the column between 0.5 and 13 km).

Pope, Shelly K.↗