Selective Sensors of Nitrogen Dioxide Based on Thin Tungsten Oxide Films under Optical Irradiation

It is shown that NO{sub 2} present in air, beginning at a concentration of 1 ppm, can be selectively detected by sensors based on Au/WO{sub 3}:Au thin films activated by laser diode radiation with maximum intensity at 400 nm instead of constant heating. The radiation-activated photodesorption reduces the time of sensor response to NO{sub 2}. A high humidity of air under conditions of room-temperature irradiation additionally increases the device sensitivity to NO{sub 2} due to the appearance of additional adsorption sites. The absence of a sensor response to reducing gases and varying oxygen concentration in the atmosphere is caused by the photodesorption of chemisorbed O{sub 2}{sup −} species during their interaction with holes generated in intrinsic optical transitions in the near-surface region of WO{sub 3} film.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Verification of proton range, position, and intensity in IMPT with a 3D liquid scintillator detector system

Purpose: Intensity-modulated proton therapy (IMPT) using spot scanned proton beams relies on the delivery of a large number of beamlets to shape the dose distribution in a highly conformal manner. The authors have developed a 3D system based on liquid scintillator to measure the spatial location, intensity, and depth of penetration (energy) of the proton beamlets in near real-time. Methods: The detector system consists of a 20 x 20 x 20 cc liquid scintillator (LS) material in a light tight enclosure connected to a CCD camera. This camera has a field of view of 25.7 by 19.3 cm and a pixel size of 0.4 mm. While the LS is irradiated, the camera continuously acquires images of the light distribution produced inside the LS. Irradiations were made with proton pencil beams produced with a spot-scanning nozzle. Pencil beams with nominal ranges in water between 9.5 and 17.6 cm were scanned to irradiate an area of 10 x 10 cm square on the surface of the LS phantom. Image frames were acquired at 50 ms per frame. Results: The signal to noise ratio of a typical Bragg peak was about 170. Proton range measured from the light distribution produced in the LS was accurate to within 0.3 mm on average. The largest deviation seen between the nominal and measured range was 0.6 mm. Lateral position of the measured pencil beam was accurate to within 0.4 mm on average. The largest deviation seen between the nominal and measured lateral position was 0.8 mm; however, the accuracy of this measurement could be improved by correcting light scattering artifacts. Intensity of single proton spots were measured with precision ranging from 3 % for the smallest spot intensity (0.005 MU) to 0.5 % for the largest spot (0.04 MU). Conclusions: Our LS detector system has been shown to be capable of fast, submillimeter spatial localization of proton spots delivered in a 3D volume. This system could be used for beam range, intensity and position verification in IMPT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Towards Reliable Cross Sections for National Security Applications

Stockpile stewardship requires the description of weapons performance without resorting to underground nuclear testing. In the earlier tests, selected isotopes were used as detectors, and recovered after irradiation. Aspects of nuclear device performance were inferred by comparing the measured isotopic ratios to those predicted from simulations. The reaction flows that produce the final isotopic distributions proceed through regions of the nuclear chart that include unstable nuclei. Presently, improved nuclear data input is required to reanalyze prior tests and to certify the stockpile's reliability and safety. Many important cross sections are unknown, as is shown in the example of the Yttrium reaction network (Figure 1). The relevant reactions include (n,2n), (n,n'), (n,gamma), (n,p) and other charged-particle emitting reactions. The cross sections have to be calculated or inferred from indirect measurements. In both cases, reliable optical models that are valid a few nucleons away from stability are needed. The UNEDF Nuclear Reaction activities address this need by combining nuclear-structure input from UNEDF structure calculations with modern reaction theory and large-scale computational capabilities to develop microscopic nucleon-nucleus optical potentials that can be extrapolated to unstable nuclei. In addition, the reaction calculation tools and optical models developed in this context are proving valuable for planning and interpreting indirect (surrogate) measurements of the required cross sections.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Carbonitriding of silicon using plasma focus device

Carbonitride thin films have been deposited on silicon substrate by the irradiation of energetic nitrogen ions emanated from dense plasma focus device. The carbon ions are ablated by the irradiation of relativistic electrons from the insert material (graphite) placed at the anode tip. The x-ray diffraction analysis demonstrates that a polycrystalline thin film consisting of various compounds such as Si{sub 3}N{sub 4}, SiC, and C{sub 3}N{sub 4} is formed on the silicon (100) substrate. Crystallinity of different compounds decreases with the increase in angular positions (0 deg., 10 deg., and 20 deg. ). Raman spectroscopy shows the appearance of graphitic and disordered bands with silicon nitride and silicon carbide indicating the formation of carbonitride. Raman spectra also indicate that broadening of bands increases with the increase in focus deposition shots, leading to the amorphization of the thin film. The amorphization of the thin films depends on the ion energy flux as well as on the sample angular position. The scanning electron microscopy exhibits the damaging of the substrate surface at 0 deg. angular position. The microstructure shows the tubular shape for higher ion dose (40 focus shots). At 10 deg. angular position, a two phase phenomenon is observed with the ordered phase in the solid solution. A smooth and uniform surface morphology showing a small cluster is observed for the 20 deg. angular position.

36 MATERIALS SCIENCE↗

Progress in Fast Ignition Studies with Electrons and Protons

Isochoric heating of inertially confined fusion plasmas by laser driven MeV electrons or protons is an area of great topical interest in the inertial confinement fusion community, particularly with respect to the fast ignition (FI) concept for initiating burn in a fusion capsule. In order to investigate critical aspects needed for a FI point design, experiments were performed to study 1) laser-to-electrons or protons conversion issues and 2) laser-cone interactions including prepulse effects. A large suite of diagnostics was utilized to study these important parameters. Using cone--wire surrogate targets it is found that pre-pulse levels on medium scale lasers such as Titan at Lawrence Livermore National Laboratory produce long scale length plasmas that strongly effect coupling of the laser to FI relevant electrons inside cones. The cone wall thickness also affects coupling to the wire. Conversion efficiency to protons has also been measured and modeled as a function of target thickness, material. Conclusions from the proton and electron source experiments will be presented. Recent advances in modeling electron transport and innovative target designs for reducing igniter energy and increasing gain curves will also be discussed. In conclusion, a program of study will be presented based on understanding the fundamental physics of the electron or proton source relevant to FI.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser Nanostructurization of the Metal and Alloy Surfaces

The results from experimental and theoretical investigation of material pulsed laser treatment aimed at obtaining nano- and microstructured surface are presented. An experiment has been performed on the modification of indium surface using a solid-state diode-pumped laser. It has been shown that nano- and micro-size structures are formed under laser melting and fast crystallization of the metal surface. The kinetics of the crystallization of metals under superfast cooling. The distribution function for crystalline nuclei dimensions is analytically found within the framework of the classical kinetic equation in case of superfast temperature changing. The average number of particles in the crystalline nuclei and relative volume of the crystalline phase are determined as functions of thermodynamic and laser treatment regime parameters. Good agreement is observed with experimental results for ultrashort laser pulses induced micro- and nanostructures production.

36 MATERIALS SCIENCE↗

Measurements of radiation effects on a 4 Mb PSRAM memory

The results of a static test of total ionizing dose (TID) effects on an ISSI 4Mb PSRAM memory are reported in this work. The irradiation was performed at the IEAv’s Laboratory of Ionizing Radiation with 1.17 and 1.32 MeV gamma-rays from a {sup 60}Co source at a dose rate of 2.5 krad/h up to an accumulated dose of 215.7 krad. The TID threshold for bit flip found in this experiment was 52.5 krad. From a sampling of 4096 memory addresses it was estimated a bit flip rate of approximately 50% at an accumulated dose of 215.7 krad.

07 ISOTOPE AND RADIATION SOURCES↗

Band offset studies in pulse laser deposited Zn{sub 1−x}Cd{sub x}O/ZnO hetero-junctions

The valence and conduction band offsets of Zn{sub 1−x}Cd{sub x}O/ZnO hetero-junctions deposited by pulsed laser deposition technique were estimated by X-ray photoelectron, valence band, and UV-visible spectroscopy. Type-II band alignment (staggered gap) with ratios of conduction band to valence band offsets (ΔE{sub C}/ΔE{sub V}) was found to be 0.77 and 0.59 for Zn{sub 0.95}Cd{sub 0.05}O/ZnO and Zn{sub 0.90}Cd{sub 0.10}O/ZnO hetero-structures, respectively, which can be used in longer wavelength regime optoelectronic devices. The higher value of valence band offset as compared to conduction band offset suggests that the transport at interface is mainly due to electrons.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of high fluence neutron irradiation on transport properties of thermoelectrics

Thermoelectric materials were subjected to high fluence neutron irradiation in order to understand the effect of radiation damage on transport properties. This paper is relevant to the NASA Radioisotope Thermoelectric Generator (RTG) program in which thermoelectric elements are exposed to radiation over a long period of time in space missions. Selected n-type and p-type bismuth telluride materials were irradiated at the High Flux Isotope Reactor with a neutron fluence of 1.3 × 10 18 n/cm 2 (E > 0.1 MeV). The increase in the Seebeck coefficient in the n-type material was partially off-set by an increase in electrical resistivity, making the power factor higher at lower temperatures. For the p-type materials, although the Seebeck coefficient was not affected by irradiation, electrical resistivity decreased slightly. The figure of merit, zT, showed a clear drop in the 300–400 K range for the p-type material and an increase for the n-type material. Considering that the p-type and n-type materials are connected in series in a module, the overall irradiation damages at the device level were limited. Finally, these results, at neutron fluences exceeding a typical space mission, are significant to ensure that the radiation damage to thermoelectrics does not affect the performance of RTGs.

36 MATERIALS SCIENCE↗

End of Life Decisions for Sealed Radioactive Sources

Sealed radioactive sources are encountered in a wide variety of settings – from household smoke detectors and instrument check sources, through fixed industrial gauges, industrial radiography and well logging sources, to irradiators and medical teletherapy devices. In general, the higher the level of activity in the sealed source, the stricter the regulatory control that is applied to its use, control and ultimate disposition. Lower levels of attention and oversight can and do lead to sources ending up in the wrong place – as orphan sources in uncontrolled storage, disposed in a sanitary landfill, melted down in metal recycling operations and incorporated into consumer products, or handled by an unsuspecting member of the public. There are a range of issues that contribute to the problem of improper disposal of sealed sources, and, in particular, to disused source disposal. General licensed sources and devices are particularly at risk of being disposed incorrectly. Higher activity general licensed sources, although required to be registered with the Nuclear Regulatory Commission (NRC) or Agreement State, receive limited regulatory oversight and are not tracked on a national scale. Users frequently do not consider the full life-cycle costs when procuring sources or devices and discover that they cannot afford to package, transport and dispose of their sources properly. The NRC requirements for decommissioning funding plans and financial assurance are not adequate to cover sealed source transport and disposal costs fully. While there are regulatory limits for storage of disused sources, enforcement is limited and there is no financial incentive for owners to dispose of the sources. In some cases, the lack of availability of approved Department of Transportation (DOT) Type B shipping casks also presents a barrier to sealed source disposal. The report of the Disused Sources Working Group does an excellent job of framing these issues. This article reviews both the issues and the report’s recommendations, which are designed to improve sealed source control and encourage proper disposal of disused sources.

disused source↗

SU-E-T-590: An Activation Study of Materials and Devices Present in a Proton Treatment Room

Purpose: The use of protons for radiation therapy is growing rapidly. One consequence of protons interacting with different media is activation. These nuclear reactions induced by the protons, scattered neutrons, and gamma rays, activate different materials encountered, particularly by the therapists. The purpose of this study was to examine the derived nuclides from the activation, and also the decay rate. Methods: The study was conducted in our proton therapy facility. Protons are derived from a synchrocyclotron and pass through field shipping systems, apertures, and range compensators to define the beam within the patient.Included materials of concerns measured; the patient support couch, sheet rock in the wall, solid plastics used for quality assurance and dosimetry, and the passive scattering system itself, which includes brass apertures, and Lucite or blue wax compensators. All devices were studied post irradiation using gamma spectroscopy to determine the nuclides, and a sodium iodine scintillation detector to measure decay, particularly when the dose rate fell to background levels. Results: We have also determined from the measurements we will maintain brass apertures for three months before sending them for scrap. Some of the radionuclides arrived from these measurements included Na-22 for the blue wax compensator, C1-34m for the sheetrock, and Sc-44 and Co-60 for the brass apertures. We found compensators made out of Lucite or wax decayed to background in 2 hours. The patient support couch decayed to background in approximately 40 minutes, and sheet rock decayed in 80 minutes. In terms of the aperture layers, the most proximal aperture slab had much higher activity than the distal slab. Also the proximal sides of the slabs were much more activate than the distal. Conclusion: We have given proper instruction to therapists performing quality assurance in terms of the handled plastics, and to handle apertures rapidly as possible.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-638: Proton Beam Delivery to a Moving Lung Tumor and Monte Carlo Simulation with TOPAS

Purpose: To estimate the dose delivered to a moving lung tumor by proton therapy beams of different modulation types, and compare with Monte Carlo predictions. Methods: A radiology support devices (RSD) phantom was irradiated with therapeutic proton radiation beams using two different types of modulation: uniform scanning (US) and double scattered (DS). The Eclipse© dose plan was designed to deliver 1.00Gy to the isocenter of a static ∼3×3×3cm (27cc) tumor in the phantom with 100% coverage. The peak to peak amplitude of tumor motion varied from 0.0 to 2.5cm. The radiation dose was measured with an ion-chamber (CC-13) located within the tumor. The time required to deliver the radiation dose varied from an average of 65s for the DS beams to an average of 95s for the US beams. Results: The amount of radiation dose varied from 100% (both US and DS) to the static tumor down to approximately 92% for the moving tumor. The ratio of US dose to DS dose ranged from approximately 1.01 for the static tumor, down to 0.99 for the 2.5cm moving tumor. A Monte Carlo simulation using TOPAS included a lung tumor with 4.0cm of peak to peak motion. In this simulation, the dose received by the tumor varied by ∼40% as the period of this motion varied from 1s to 4s. Conclusion: The radiation dose deposited to a moving tumor was less than for a static tumor, as expected. At large (2.5cm) amplitudes, the DS proton beams gave a dose closer to the desired dose than the US beams, but equal within experimental uncertainty. TOPAS Monte Carlo simulation can give insight into the moving tumor — dose relationship. This work was supported in part by the Philips corporation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Computational and Experimental Simulation of Static Memory Cells of Submicron Microcircuits under the Effect of Neutron Fluxes

The simulation of reversible single events in test samples of static memory microcircuits with design norms of 0.5, 0.35, 0.25, and 0.1 μm under the effect of neutron fluxes with various energies is performed. It is shown theoretically and experimentally that reversible single events can occur in modern microelectronics and nanoelectronics products under the effect of a fission-spectrum neutron flux caused by the passage of primary recoil atoms and nuclear reaction products along the microcircuit surface perpendicularly to the electric current lines in the near-drain transistor area. A series of irradiation experiments of static memory circuits with design norms of 0.35 μm is interpreted based on the proposed model.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of Heat Treatment on the Dispersion of the Magnetic Anisotropy of MnSb Nanoinclusions Embedded in Thin GaMnSb Films

We observed a temperature-controlled increase in the magnetic anisotropy and its dispersion in thin GaMnSb films with MnSb nanoinclusions obtained by pulsed laser deposition. The data of transmission electron microscopy indicate that in the samples, a transition of the crystalline structure of magnetic MnSb nanoinclusions from hexagonal (spatial group (sp. gr.) P6{sub 3}/mmc) to cubic (sp. gr. F-43m) takes place. Analysis of the temperature dependences of the magnetic moment m(T), measured using a SQUID magnetometer, obtained for both unannealed and annealed samples cooled in a zero magnetic field and a magnetic field of 10 kOe, indicates that this mechanism is not unique. In unannealed samples, the distribution of the magnetic anisotropy of MnSb nanoinclusions, determined from the dependences of m(T), is unimodal. In the annealed samples, the same dependence becomes multimodal. This means that several thermally activated processes occur in the samples during annealing, resulting in several “populations” of nanoinclusions present in the annealed thin films. The contribution to the increase in the magnetic anisotropy during annealing can result in the structural phase transition, the mismatch of the crystal lattices between MnSb and GaSb, an increase in the average volume of MnSb nanoinclusions, and a change in their stoichiometry.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Progress report of Sandia National Laboratories (SNL) contribu- tion to IAEA CRP F11016 on ?Utilization of ion accelerators for studying and modeling of radiation induced defects in semicon- ductors and insulators? 3rd RCM.

This report presents the results of Sandia National Laboratories’ (SNL) contribution to IAEA CRP F11016 as mostly raw data. The goal of this CRP is to study the effects of radiation on semiconductors and insulators with the emphasis on the effect of displacement damage due to MeV energy ions on the performance of semiconductor detectors and microelectronic devices. SNL is tasked with performing electrical characterization, irradiation, and IBIC, DLTS, C-­V measurements on devices used in the CRP, as well as calculating damage and ionization profiles for modeling.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Instrumentation Testing for TREAT Experiments

Instrumentation testing for TREAT experiments in order to test sensors and measurement devices prior to TREAT irradiation to ensure proper collection of data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Probability Density Function for the spatial and intensity distribution of neutron-induced defects in Silicon

The ability to model semiconductor device degradation under neutron irradiation depends upon having a robust modeling capability for the neutron-induced collision cascades as well as a means to analytically fit the resulting probability distributions of defect production and ionizing energy deposition for purposes of extrapolation to low-probability, high-consequence scenarios. In this paper, the widely-utilized binary collision approximation codes MARLOWE and SRIM are deployed in conjunction with a critical examination of their parameterizations as benchmarked against higher-fidelity molecular dynamics simulations. A simple 3-parameter form described by the Generalized Logistic Distribution is shown to be a good fit to Frenkel pair and ionization intensity distributions in bulk silicon. The BCA codes are then applied to simulate cascades in 5 nm layers of a representative gate-all-around nanosheet transistor, where joint probability distributions of threshold levels of damage to multiple layers are evaluated.

36 MATERIALS SCIENCE↗

Analysis of the IBL and LBNL irradiated PIN and PN diodes

This report is a follow-up to the previous report on the difference between high fluence, high and low flux irradiations. There was a discrepancy in the data for the LBNL irradiated S5821 PIN diodes. There were diodes irradiated in the two batches (high and low flux) with the same flux and fluence for reference (lell ions/cm 2 /shot and 5, 10, and 20 ions/cm 2 total flux). Although these diodes should have the same electrical characteristics their leakage currents were different by a factor of 5-6 (batch 2 was larger). Also, the C-V measurements showed drastically different results. It was speculated that these discrepancies were due to one of the following two reasons: 1. Different times elapsed between radiation and characterization. 2. Different areas were irradiated (roughly half of the diodes were covered during irradiation). To address the first concern, we annealed the devices according to the ASTM standard [1]. The differences remained the same. To determine the irradiated area, we performed large area IBIC scans on several devices. Error! Reference source not found. below shows the IBIC maps of two devices one from each batch. The irradiated areas are approximately the same.