Search NASA⌕ Search

SEARCH · Search NASA

Results for “Image”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Molecular Imaging of Microbially Induced Corrosion of Synthetic Archeological Glasses by a Rhizosphere Bacterium

Microbially induced corrosion (MIC) focuses on the degradation of solid materials, such as glass or metal. Soil microbes are often associated with the corrosion of foreign objects in the rhizosphere. Paenibacillus polymyxa SCE2, a facultative anaerobic bacterium in soil, is of the same genus as bacteria found near nuclear waste disposal sites. Time-of-flight secondary ion mass spectrometry (ToF-SIMS) was used for imaging surface changes induced by P. polymyxa SCE2 cultured on two synthetic glass coupons to represent natural analogs of materials that were studied in relation to the vitrification of nuclear waste. Multimodal imaging was used to verify bacterial coverage across the glass surface after long-term growth. ToF-SIMS spectral analysis showed detection of glass component ions, such as silicon oxide (m/z – 59.96 SiO 2 – ) and aluminum oxide (m/z – 101.95 Al 2 O 3 – ), and biofilm’s extracellular polymeric substance (EPS) components, such as pentadecanoic acid (m/z – 241.22 C 15 H 29 O 2 – ) and sterol lipids (m/z – 311.16 C 20 H 23 O 3 – ). ToF-SIMS spectral, imaging, and depth profiling analyses showed that the glass rich in silica and other light elements (“granite glass”) had more “corrosion related” peaks than the glass that was less silica-rich and contained more iron (“dike glass”). Furthermore, these surface and interface compositional and spatial differences observed in the mass spectra and imaging were attributed to bacterial metabolism and an electron transfer mechanism influenced by morphological and compositional differences between the two types of glasses. ToF-SIMS is effective in studying microbial effects, bringing new molecular insights into MIC in a broader context of materials degradation.

Amorphous materials↗

A modular chemigenetic calcium indicator for multiplexed in vivo functional imaging

Abstract Genetically encoded fluorescent calcium indicators allow cellular-resolution recording of physiology. However, bright, genetically targetable indicators that can be multiplexed with existing tools in vivo are needed for simultaneous imaging of multiple signals. Here we describe WHaloCaMP, a modular chemigenetic calcium indicator built from bright dye-ligands and protein sensor domains. Fluorescence change in WHaloCaMP results from reversible quenching of the bound dye via a strategically placed tryptophan. WHaloCaMP is compatible with rhodamine dye-ligands that fluoresce from green to near-infrared, including several that efficiently label the brain in animals. When bound to a near-infrared dye-ligand, WHaloCaMP shows a 7× increase in fluorescence intensity and a 2.1-ns increase in fluorescence lifetime upon calcium binding. We use WHaloCaMP1a to image Ca 2+ responses in vivo in flies and mice, to perform three-color multiplexed functional imaging of hundreds of neurons and astrocytes in zebrafish larvae and to quantify Ca 2+ concentration using fluorescence lifetime imaging microscopy (FLIM).

Biochemistry & Molecular Biology↗

Light-powered end-to-end neutron detection and imaging with an edge-deployed optical AI chip

Neutron detection is widely used in many applications including nuclear physics, nuclear energy, nuclear technologies and nuclear safeguards. Developing an end-to-end neutron detection and imaging workflow paves way towards fully automated processes for many applications. We implemented an automated workflow for neutron detection experiments which use a solid state image sensor to capture neutron hits as a digital image. We deploy the workflow to an edge-based optical neural network (ONN) to increase the radiation-hardness and lifetime of neutron detection instruments. We present a two-stage neural network framework for detection of neutrons at sub-pixel resolution. The first stage uses a region proposal network to efficiently detect and extract neutron hits from the input camera image. The second stage feeds the extracted hits into a fully connected neural network to predict the sub-pixel hit position. The performance of the two-stage framework is evaluated using the edge-based ONN. The results show that we can achieve above 96% neutron detection accuracy as well as sub-pixel and sub-micron position resolution, while enjoying the advantages of the ONN hardware including radiation-hardness, low energy consumption and high computing speed for integrated edge camera and hardware deployment, when compared with electronic counterparts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wavefront distortion correction in scanning tunneling microscope image

Here, we report an algorithm to identify and correct distorted wavefronts in atomic resolution scanning tunneling microscope images. This algorithm can be used to correct nonlinear in-plane distortions without prior knowledge of the physical scanning parameters, the characteristics of the piezoelectric actuator, or individual atom positions. The 2D image is first defined as a sum of sinusoidal plane waves, where a nonlinear distortion renders a curve for an otherwise ideal linear wavefront. Using the Fourier transforms of local areas of the image, the algorithm generates a wavefront vector field. The identified wavefronts are subsequently linearized for each plane wave without changing lattice orders, giving rise to distortion corrections. Our algorithm is complementary to conventional post-processing algorithms that require prior detection of real space features, which can also be used to correct nonlinear distortions in 2D images acquired by other microscopy techniques.

47 OTHER INSTRUMENTATION↗

Cross-correlation image analysis for real-time single particle tracking

Accurately measuring the translations of objects between images is essential in many fields, including biology, medicine, chemistry, and physics. One important application is tracking one or more particles by measuring their apparent displacements in a series of images. Popular methods, such as the center of mass, often require idealized scenarios to reach the shot noise limit of particle tracking and, therefore, are not generally applicable to multiple image types. More general methods, such as maximum likelihood estimation, reliably approach the shot noise limit, but are too computationally intense for use in real-time applications. These limitations are significant, as real-time, shot-noise-limited particle tracking is of paramount importance for feedback control systems. To fill this gap, we introduce a new cross-correlation-based algorithm that approaches shot-noise-limited displacement detection and a graphics processing unit-based implementation for real-time image analysis of a single particle.

Instruments & Instrumentation↗

Simulations of muon imaging with the LANL GMT detector for spent nuclear fuel cask content verification

Atmospheric muons are typically high energy, highly penetrating charged particles. They interact with matter primarily through multiple Coulomb scatterings. Muon scattering intensities can be used to characterize the density and atomic number of the matter that they pass through. Previously, the Los Alamos National Laboratory (LANL) muon tomography team performed muon imaging of the partially filled MC-10 spent nuclear fuel (SNF) cask at Idaho National Laboratory (INL). This experiment demonstrated the feasibility of muon imaging for the verification of spent fuel container contents. That original effort used the mini muon tracker array, consisting of two arrays of drift tubes on either side of the SNF cask. The reconstructed image quality was limited by statistics, largely due to low muon flux at high zenith angles. A LANL led team will perform new measurements with a larger array, the Giant Muon Tracker (GMT), to improve data collection rates and statistics. In this work, simulations were performed with the GMT near the partially filled INL MC-10 cask. For more general fuel diversion detection, a full MC-10 cask and casks with a singular missing fuel bundle were also simulated. To understand minimum measurement times needed for missing bundle identification, 100 000 to millions of tracked muons (corresponding to 1.4 days to several weeks measurement time) were analyzed. Simulated images were then analyzed visually and numerically to explore techniques designed to minimize the collection time needed to identify the diversion of fuel in each scenario.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Multidimensional images and aberrations in STEM

Recent advances in scanning transmission electron microscopy (STEM) have led to increased development of multi-dimensional STEM imaging modalities and novel image reconstruction methods. This interest arises because the main electron lens in a modern transmission electron microscope usually has a diffraction-space information limit that is significantly better than the real-space resolution of the same lens. This state-of-affairs is sometimes shared by other scattering methods in modern physics and contributes to a broader excitement surrounding multidimensional techniques that scan a probe while recording diffraction-space images, such as ptychography and scanning nano-beam diffraction. However, the contrasting resolution in the two spaces raises the question as to what is limiting their effective performance. Here, we examine this paradox by considering the effects of aberrations in both image and diffraction planes, and likewise separate the contributions of pre- and post-sample aberrations. In conclusion, this consideration provides insight into aberration-measurement techniques and might also indicate improvements for super-resolution techniques.

Hoglund, Eric R.↗

Inverse rendering of fusion plasmas: Inferring plasma composition from imaging systems

In this work, we develop a differentiable rendering pipeline for visualising plasma emission within tokamaks, and estimating the gradients of the emission and estimating other physical quantities. Unlike prior work, we are able to leverage arbitrary representations of plasma quantities and easily incorporate them into a non-linear optimisation framework. The efficiency of our method enables not only estimation of a physically plausible image of plasma, but also recovery of the neutral Deuterium distribution from imaging and midplane measurements alone. We demonstrate our method with three different levels of complexity showing first that a poloidal neutrals density distribution can be recovered from imaging alone, second that the distributions of neutral Deuterium, electron density and electron temperature can be recovered jointly, and finally, that this can be done in the presence of realistic imaging systems that incorporate sensor cropping and quantisation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterizing electron-collecting CdTe for use in a 77 ns burst-rate imager

The Keck-PAD (pixel array detector) was developed at Cornell as a burst-rate imager capable of recording images from successive electron bunches (153 ns period) from the Advanced Photon Source (APS). Both Si and hole-collecting Schottky CdTe have been successfully bonded to this ASIC (application-specific integrated circuit) and used with this frame rate. The facility upgrades at the APS will lower the bunch period to 77 ns, which will require modifications to the Keck-PAD electronics to image properly at this reduced period. In addition, operation at high X-ray energies will require a different sensor material having a shorter charge collection time. For the target energy of 40 keV for this project, simulations have shown that electron-collecting CdTe should allow >90% charge collection within 35 ns. This collection time will be sufficient to sample the signal from one frame and prepare for the next. 750 µm-thick electron-collecting Schottky CdTe has been obtained from Acrorad and bonded to two different charge-integrating ASICs developed at Cornell, the Keck-PAD and the CU-APS-PAD. Carrier mobility has been investigated using the detector response to single X-ray bunches at the Cornell High Energy Synchrotron Source and to a pulsed optical laser. The tests indicate that the collection time will meet the requirements for 77 ns imaging.

36 MATERIALS SCIENCE↗

Maximizing the Radar Generalized Image Quality Equation for Bistatic SAR Using Waveform Frequency Agility

The radar generalized image quality equation (RGIQE) is a metric used to measure both monostatic and bistatic synthetic aperture radar (BSAR) image quality, it is a function of signal-to-noise ratio (SNR) and 2-D bandwidth. The 2-D bandwidth is equal to the area of the transfer function’s (TF) passband region. With the exception of side-looking monostatic geometries, almost all monostatic and bistatic geometries have skewed passband shapes when waveform frequency parameters remain unchanged from pulse to pulse. Most synthetic aperture radar (SAR) applications require a rectangular-shaped passband region, this is achieved by inscribing a rectangular region within the skewed intrinsic passband region. Increasing skewness results in less inscription area reducing 2-D bandwidth, image SNR, and thus RGIQE capacity. In this article, a waveform with frequency agility is used to rectify the skewness that degrades RGIQE capacity. By changing the waveform’s center frequency and instantaneous bandwidth from pulse to pulse in a particular manner, the intrinsic passband region can be de-skewed. The de-skewed shape maximizes the inscription area thus maximizing 2-D bandwidth, image SNR, and RGIQE capacity. Here, three examples are given in this article, one monostatic geometry, and two bistatic geometries. RGIQE capacity is increased by 52.02%, 44.42%, and 79.09% for the three examples.

47 OTHER INSTRUMENTATION↗

Radiation Monitoring for Volatilized Zinc Contamination Using Gamma-Ray Imaging and Spectroscopy

Gamma-ray imaging is a tool that has grown in importance in the applications of non-destructive assay (NDA) for radioactive survey and analysis of nuclear facilities. Imaging techniques have shown great promise in providing valuable information involving radioactive waste management and contamination prevention. For the application studied in this work, 65 Zn has been identified as a radioactive contaminant during tritium extraction. Due to the volatile nature of 65 Zn under the pressure and temperature changes during extraction operations, 65 Zn can easily travel through components of the extraction system as vapor, making it difficult to trap. Previous research involving the development of a filtration system showed that the 65 Zn can be trapped, mitigating product contamination. However, during the extraction process, direct analysis of the equipment to confirm that zinc contamination is trapped in the filter and has not spread to other components is impractical. Here, in this situation, the need to assay the location of the contamination with little-to-no interference with operations is vital. In this work, we demonstrate the use of a commercialized 3D position-sensitive CdZnTe (CZT) gamma-ray imaging spectrometer to provide analysis of the 65 Zn contamination. Onsite measurements during an extraction process are studied to assess the location and migration of the 65 Zn. The results obtained from real-time glovebox monitoring demonstrate the feasibility of gamma-ray imaging for localizing the contamination and providing a preliminary qualitative assessment that is intended to be used in future work quantifying the contamination build-up and activity over time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Robust measurement of microbial reduction of graphene oxide nanoparticles using image analysis

ABSTRACT Shewanella oneidensis ( S. oneidensis ) has the capacity to reduce electron acceptors within a medium and is thus used frequently in microbial fuel generation, pollutant breakdown, and nanoparticle fabrication. Microbial fuel setups, however, often require costly or labor-intensive components, thus making optimization of their performance onerous. For rapid optimization of setup conditions, a model reduction assay can be employed to allow simultaneous, large-scale experiments at lower cost and effort. Since S. oneidensis uses different extracellular electron transfer pathways depending on the electron acceptor, it is essential to use a reduction assay that mirrors the pathways employed in the microbial fuel system. For microbial fuel setups that use nanoparticles to stimulate electron transfer, reduction of graphene oxide provides a more accurate model than other commonly used assays as it is a bulk material that forms flocculates in solutions with a large ionic component. However, graphene oxide flocculates can interfere with traditional absorbance-based measurement techniques. This study introduces a novel image analysis method for quantifying graphene oxide reduction, showing improved performance and statistical accuracy over traditional methods. A comparative analysis shows that the image analysis method produces smaller errors between replicates and reveals more statistically significant differences between samples than traditional plate reader measurements under conditions causing graphene oxide flocculation. Image analysis can also detect reduction activity at earlier time points due to its use of larger solution volumes, enhancing color detection. These improvements in accuracy make image analysis a promising method for optimizing microbial fuel cells that use nanoparticles or bulk substrates. IMPORTANCE Shewanella oneidensis ( S. oneidensis ) is widely used in reduction processes such as microbial fuel generation due to its capacity to reduce electron acceptors. Often, these setups are labor-intensive to operate and require days to produce results, so use of a model assay would reduce the time and expenses needed for optimization. Our research developed a novel digital analysis method for analysis of graphene oxide flocculates that may be utilized as a model assay for reduction platforms featuring nanoparticles. Use of this model reduction assay will enable rapid optimization and drive improvements in the microbial fuel generation sector.

Bennett, Danielle T. (ORCID:0009000188748827)↗

Lowering and Runtime Support for Fortran’s Multi-Image Parallel Features using LLVM Flang, PRIF, and Caffeine

This paper provides an overview of the multi-image parallel features in Fortran 2023 and their implementation in the LLVM flang compiler and the Caffeine parallel runtime library. The features of interest support a Single-Program, Multiple-Data (SPMD) programming model based on executing multiple “images”, each of which is a program instance. The features also support a Partitioned Global Address Space (PGAS) in the form of “coarray” distributed data structures. The paper discusses the lowering of multi-image features to the Parallel Runtime Interface for Fortran (PRIF) and the implementation of PRIF in the Caffeine parallel runtime library. This paper also provides an early view into the design of a new multi-image dialect of the LLVM Multi-Level Intermediate Representation (MLIR). We describe validation and testing of the resulting software stack, and demonstrate that performance compares favorably to another open-source compiler and runtime library: GNU Compiler Collection (GCC) gfortran and OpenCoarrays, respectively.

Bonachea, Dan↗

Foundation Models for Zero-Shot Segmentation of Scientific Images without AI-Ready Data

Zero-shot and prompt-based models have excelled at visual reasoning tasks by leveraging large-scale natural image corpora, but they often fail on sparse and domain-specific scientific image data. We introduce Zenesis, a no-code interactive computer vision platform designed to reduce data readiness bottlenecks in scientific imaging workflows. Zenesis integrates lightweight multimodal adaptation for zero-shot inference on raw scientific data, human-in-the-loop refinement, and heuristic-based temporal enhancement. We validate our approach on Focused Ion Beam Scanning Electron Microscopy (FIB-SEM) datasets of catalyst-loaded membranes. Zenesis outperforms baselines, achieving an average accuracy of 0.947, Intersection over Union (IoU) of 0.858, and Dice score of 0.923 on amorphous catalyst samples; and 0.987 accuracy, 0.857 IoU, and 0.923 Dice on crystalline samples. These results represent a significant performance gain over conventional methods such as Otsu thresholding and standalone models like the Segment Anything Model (SAM). Zenesis enables effective image segmentation in domains where annotated datasets are limited, offering a scalable solution for scientific discovery.

Mukherjee, Shubhabrata↗

Variation in forest root image annotation by experts, novices, and AI

Abstract Background The manual study of root dynamics using images requires huge investments of time and resources and is prone to previously poorly quantified annotator bias. Artificial intelligence (AI) image-processing tools have been successful in overcoming limitations of manual annotation in homogeneous soils, but their efficiency and accuracy is yet to be widely tested on less homogenous, non-agricultural soil profiles, e.g., that of forests, from which data on root dynamics are key to understanding the carbon cycle. Here, we quantify variance in root length measured by human annotators with varying experience levels. We evaluate the application of a convolutional neural network (CNN) model, trained on a software accessible to researchers without a machine learning background, on a heterogeneous minirhizotron image dataset taken in a multispecies, mature, deciduous temperate forest. Results Less experienced annotators consistently identified more root length than experienced annotators. Root length annotation also varied between experienced annotators. The CNN root length results were neither precise nor accurate, taking ~ 10% of the time but significantly overestimating root length compared to expert manual annotation ( p = 0.01). The CNN net root length change results were closer to manual ( p = 0.08) but there remained substantial variation. Conclusions Manual root length annotation is contingent on the individual annotator. The only accessible CNN model cannot yet produce root data of sufficient accuracy and precision for ecological applications when applied to a complex, heterogeneous forest image dataset. A continuing evaluation and development of accessible CNNs for natural ecosystems is required.

Handy, Grace↗

Thermal images collected during large-scale 3D printing with Ingersoll MasterPrint

This data set contains images produced to test the performance of anomaly and fault detection methods in the context of additive manufacturing. Two print jobs were executed using the Ingersoll MasterPrint with the Model 30 Strangpresse extruder. The material used was Techmer compounded polylactic acid (PLA) with wood flour as a filler (80/20 PLA/WF by weight). The first print job consists of the 3D printing of a hexagonal cylinder with a two-bead wall. This print was sliced at a gantry velocity of 3000 millimeter per minute, and an extruder screw speed of 68.14 rotations per minute. This are considered the normal operating conditions. A second hexagonal cylinder was printed using a reduced extruder screw speed, 15% lower than under normal operating conditions. The images were collected with a Teledyne FLIR Lepton 3.5 infra-red camera, a small form factor radiometric long-wave infrared camera with a spectral range of 8 µm to 14 µm. Sensor resolution was 160x120 pixels, with a pixel size of 12 µm, a temperature range of -10 - 450°C, and an accuracy of +/- 10°C in its low gain configuration. Images in this data set were collected with cameras oriented at the printer nozzle. The nozzle camera setup consisted of two cameras located 12.5cm from the nozzle center. These were mounted directly to the print head, so that the camera positions relative to the print direction would remain constant as it rotated around its C-axis to follow the print path. One camera was placed ahead of the nozzle to capture the previous layer immediately before being covered by the new layer of material, while the second camera was placed behind the nozzle and captured the freshly extruded bead. Images are collecting during each phase of the print: (a) idle (i.e., no material deposited), (b) extrusion (i.e., to prime the extruder), and (c) printing (deposition of material to manufacture the hexagonal cylinder).

36 MATERIALS SCIENCE↗

Imaging extended single crystal lattice distortion fields with multi-peak Bragg ptychography

Recent advances in phase-retrieval-based x-ray imaging methods have demonstrated the ability to reconstruct 3D distortion vector fields within a nanocrystal by using coherent diffraction information from multiple crystal Bragg reflections. However, these works do not provide a solution to the challenges encountered in imaging lattice distortions in crystals with significant defect content that result in phase wrapping. Moreover, these methods only apply to isolated crystals smaller than the x-ray illumination, and therefore cannot be used for imaging of distortions in extended crystals. We introduce multi-peak Bragg ptychography which addresses both challenges via an optimization framework that combines stochastic gradient descent and phase unwrapping methods for robust image reconstruction of lattice distortions and defects in extended crystals. Our work uses modern automatic differentiation toolsets so that the method is easy to extend to other settings and easy to implement in high-performance computers. This work is particularly timely given the broad interest in using the increased coherent flux in fourth-generation synchrotrons for innovative material research.

36 MATERIALS SCIENCE↗

Stochastic frequency fluctuation super-resolution imaging

The inherent non-linearity of intensity correlation functions can be used to spatially distinguish identical emitters beyond the diffraction limit, as achieved, for example, in super-resolution optical fluctuation imaging (SOFI). Here, we propose a complementary concept based on spectral correlation functions, termed spectral fluctuation super-resolution (SFSR) imaging. Through theoretical and computational analysis, we show that spatially resolving time-frequency correlation functions in the image plane can improve the imaging resolution by a factor of $\sqrt2$ in most cases and up to twofold for strictly two emitters. This improvement is achieved by quantifying the degree of correlation in spectral fluctuations across the spatial domain. Experimentally, SFSR can be implemented using a combination of interferometry and photon-correlation measurements. The method works for non-blinking emitters and stochastic spectral fluctuations with arbitrary temporal statistics. This suggests its utility in super-resolution microscopy of quantum emitters at low temperatures, where spectral diffusion is often more pronounced than emitter blinking.

47 OTHER INSTRUMENTATION↗