Search NASA⌕ Search

SEARCH · Search NASA

Results for “Imaging System Camera”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

An all-sky X-ray monitor for the UK-5 satellite.

An X-ray imaging system using a pin-hole camera and a position sensitive proportional counter at the image plane has been designed for an all-sky X-ray monitor for UK-5 satellite. This high-sensitivity device with real-time coverage of the entire celestial sphere would aid in programming satellite maneuvers such that transient events in the X-ray sky could be investigated in detail by the other primary satellite experiments. Discussion of design criteria for the camera geometry, the position sensitive proportional detector, and electronics to handle the data is presented in this paper.

Desai, U. D.↗

Guide to the use of Mariner images

Planetary imaging from unmanned spacecraft, almost exclusively done by digital systems, is examined. The Mars Mariner 9 television camera, representative of such systems, is considered. Each image consists of 700 lines, each containing 832 picture elements, or pixels. Each pixel contains nine binary bits of information capable of displaying 512 discrete brightness levels. Several problems inherent in television systems are discussed. These include nonuniform target response, residual images, noise, and blemishes. These defects can be removed to some extent by decalibration of the image. The final product is geometrically corrected for camera distortion and photometrically corrected. Several versions of the decalibrated images are available. The most generally useful are the geometrically corrected images with enhanced contrast. The Mariner 10 imaging of Mercury is briefly discussed.

Saunders, R. S.↗

High resolution imaging of the Venus night side using a Rockwell 128x128 HgCdTe array

The University of Hawaii operates an infrared camera with a 128x128 HgCdTe detector array on loan from JPL's High Resolution Imaging Spectrometer (HIRIS) project. The characteristics of this camera system are discussed. The infrared camera was used to obtain images of the night side of Venus prior to and after inferior conjunction in 1988. The images confirm Allen and Crawford's (1984) discovery of bright features on the dark hemisphere of Venus visible in the H and K bands. Our images of these features are the best obtained to date. Researchers derive a pseudo rotation period of 6.5 days for these features and 1.74 microns brightness temperatures between 425 K and 480 K. The features are produced by nonuniform absorption in the middle cloud layer (47 to 57 Km altitude) of thermal radiation from the lower Venus atmosphere (20 to 30 Km altitude). A more detailed analysis of the data is in progress.

Hodapp, K.-W.↗

Measurement of Separated Flow Structures Using a Multiple-Camera DPIV System

A novel multiple-camera system for the recording of digital particle image velocimetry (DPIV) images acquired in a two-dimensional separating/reattaching flow is described. The measurements were performed in the NASA Langley Subsonic Basic Research Tunnel as part of an overall series of experiments involving the simultaneous acquisition of dynamic surface pressures and off-body velocities. The DPIV system utilized two frequency-doubled Nd:YAG lasers to generate two coplanar, orthogonally polarized light sheets directed upstream along the horizontal centerline of the test model. A recording system containing two pairs of matched high resolution, 8-bit cameras was used to separate and capture images of illuminated tracer particles embedded in the flow field. Background image subtraction was used to reduce undesirable flare light emanating from the surface of the model, and custom pixel alignment algorithms were employed to provide accurate registration among the various cameras. Spatial cross correlation analysis with median filter validation was used to determine the instantaneous velocity structure in the separating/reattaching flow region illuminated by the laser light sheets. In operation the DPIV system exhibited a good ability to resolve large-scale separated flow structures with acceptable accuracy over the extended field of view of the cameras. The recording system design provided enhanced performance versus traditional DPIV systems by allowing a variety of standard and non-standard cameras to be easily incorporated into the system.

Humphreys, William M., Jr.↗

Science and Science-Enabling Activities of the SHERLOC and WATSON Imaging Systems in Jezero Crater, Mars

During its first year of operation, the Perseverance rover explored the cratered and fractured floor of Jezero crater on Mars. Here, we report the use of the Scanning Habitability Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) imaging system that includes two high-resolution cameras, the Autofocus and Contextual Imager (ACI) and Wide Angle Topographic Sensor for Operations and eNgineering (WATSON). ACI is a fixed focus gray scale imager with a resolution of 10.1 μm/pixel whereas WATSON is a variable field of view, variable focus imager capable of resolution down to 14 μm/pixel. WATSON is a reflight of the MArs Hand Lens Imager (MAHLI) imager and has similar capabilities. During first-time activities, WATSON was used to support both science and engineering operations related to sample and abrasion patch assessment and sample collection and caching. WATSON also documented the deployment of the Ingenuity helicopter. The Crater Floor Campaign identified two primary rock units, the Máaz formation and the Séítah formation, which have been interpreted as lava flows and an olivine cumulate, respectively. Interpretation of rock textures with WATSON and ACI images was limited to abraded surfaces because unmodified outcrop surfaces (herein termed “natural surfaces”) show high degrees of dust covering, wind abrasion, and coating by secondary mineral products. WATSON and ACI images support the hypothesis that the material of both the Máaz and Séítah formations consists of largely aqueously altered mafic materials with varying igneous origins.

WATSON↗

Multispectral Snapshot Imagers Onboard Small Satellite Formations for Multi-Angular Remote Sensing

Multispectral snapshot imagers are capable of producing 2D spatial images with a single exposure at selected, numerous wavelengths using the same camera, therefore operate differently from push broom or whiskbroom imagers. They are payloads of choice in multi-angular, multi-spectral imaging missions that use small satellites flying in controlled formation, to retrieve Earth science measurements dependent on the targets Bidirectional Reflectance-Distribution Function (BRDF). Narrow fields of view are needed to capture images with moderate spatial resolution. This paper quantifies the dependencies of the imagers optical system, spectral elements and camera on the requirements of the formation mission and their impact on performance metrics such as spectral range, swath and signal to noise ratio (SNR). All variables and metrics have been generated from a comprehensive, payload design tool. The baseline optical parameters selected (diameter 7 cm, focal length 10.5 cm, pixel size 20 micron, field of view 1.15 deg) and snapshot imaging technologies are available. The spectral components shortlisted were waveguide spectrometers, acousto-optic tunable filters (AOTF), electronically actuated Fabry-Perot interferometers, and integral field spectrographs. Qualitative evaluation favored AOTFs because of their low weight, small size, and flight heritage. Quantitative analysis showed that waveguide spectrometers perform better in terms of achievable swath (10-90 km) and SNR (greater than 20) for 86 wavebands, but the data volume generated will need very high bandwidth communication to downlink. AOTFs meet the external data volume caps well as the minimum spectral (wavebands) and radiometric (SNR) requirements, therefore are found to be currently feasible in spite of lower swath and SNR.

Nag, Sreeja↗

Robot-Control Station Would Adapt To Operator

Proposed control station for remote robot adapts control system to personal characteristics and preferences of operator. Automatically adjusts positions and angles of video cameras and monitors, adjusts characteristics of hand controller, process images, and provides graphical displays serving operator best. System of one or more video cameras, controlled by computer, views workspace of robot, as shown in article, "Movable Cameras and Monitors For Viewing Telemanipulator" (NPO-17837). Control station includes several video monitors, hand controller, image-processing system providing graphical displays, voice-input command system, keyboards, and mouse.

Diner, Daniel B.↗

Design of a Lunar Plume-Surface Interaction Measurement System

Plume-surface interactions between a rocket plume and the lunar surface will be studied in-situ during two of NASA’s upcoming Commercial Lunar Payload Services Program missions. The payload, Stereo Cameras for Lunar Plume-Surface Studies (SCALPSS), will employ a multiple-camera photogrammetry system to obtain stereo images of the lunar regolith before, during, and after significant erosion and subsequent crater formation. The evaluation of measurement system capabilities and design process of the payload is informed by computational fluid dynamics predictions, accuracy modeling based on experimental data, camera simulation, and lander design, all of which are combined in the Virtual Diagnostic Interface. The second SCALPSS mission, traveling to the moon on Firefly Aerospace’s Blue Ghost lander in early 2023, aims to build on the design and complexity of the first payload, which is launching in early 2022 on Intuitive Machines’ Nova-C lander. The Blue Ghost SCALPSS mission will include two additional cameras and a total of three different lens focal lengths which will target specific points in the vehicle’s descent to obtain quantitative and accurate 3D reconstruction of the lunar surface both prior to and after crater formation.

photogrammetry↗

Large field-of-view event-mode camera for high-precision epithermal neutron resonance imaging

A large-area event-mode camera system coupled with a 6 LiF-ZnS:Ag scintillator is applied for neutron resonance imaging (NRI) on the energy-resolved neutron imaging (ERNI) flight path, also known as Flight Path 5 (FP5), at the Los Alamos Neutron Science Center (LANSCE). This novel neutron imaging system, featuring a 120 x 120 mm 2 field of view, efficiently captures resonance information across the entire image in a single acquisition, significantly reducing beam time requirements compared to conventional energy-resolved neutron imaging systems. High-quality neutron radiographs with enhanced spatial resolution are achieved through the reconstruction of neutron events based on observations of individual photons emitted from the scintillator. The system demonstrates reduced background through neutron/gamma discrimination capabilities while maintaining sharpness across a large fields of view. In the measurements presented here, a spatial resolution of approximately 340 μm was achieved using center-of-gravity photon cluster centroiding. We demonstrate the system’s capability for quantitatively determining isotopic distributions in various thin samples, as well as automatically reconstructing complex scenes with overlapping resonances from diverse samples. These results are obtained using standard data analysis tools, despite the relatively slow 6 LiF-ZnS:Ag scintillator, which may not be optimal for absorption resonance detection. The capabilities demonstrated here offer a valuable, versatile, and cost-effective solution for high spatial and temporal resolution, large field-of-view energy-resolved neutron imaging, with potential applications across various scientific and industrial domains.

36 MATERIALS SCIENCE↗

Automated Camera Calibration

Automated Camera Calibration (ACAL) is a computer program that automates the generation of calibration data for camera models used in machine vision systems. Machine vision camera models describe the mapping between points in three-dimensional (3D) space in front of the camera and the corresponding points in two-dimensional (2D) space in the camera s image. Calibrating a camera model requires a set of calibration data containing known 3D-to-2D point correspondences for the given camera system. Generating calibration data typically involves taking images of a calibration target where the 3D locations of the target s fiducial marks are known, and then measuring the 2D locations of the fiducial marks in the images. ACAL automates the analysis of calibration target images and greatly speeds the overall calibration process.

Chen, Siqi↗

Deep Interacting Multiple Model Filtering

In this paper, a deep learning-based multiple model estimation framework is presented for the state estimation of hybrid dynamical systems from high dimensional observations such as camera images. A low dimensional vector which represents the measurement of the latent dynamical system and its corresponding variance are learned using a deep encoder neural network. An Interacting Multiple Model (IMM) filter is used to generate the latent state estimates and covariances using multiple dynamical models, which can be learned using backpropagation through time. The state estimates of the dynamical system and the corresponding covariance matrix are generated from the latent state estimates and covariance using a deep decoder neural network. The whole network is trained in an end-to-end manner using a loss function which minimizes the negative log-likelihood of the neural network parameters. Simulation results are presented using a 2D bouncing ball example and estimation error statistics are computed which demonstrates the accuracy and consistency of the estimation.

Ghananeel Rotithor↗

Method for acquiring, storing and analyzing crystal images

A system utilizing a digital computer for acquiring, storing and evaluating crystal images. The system includes a video camera (12) which produces a digital output signal representative of a crystal specimen positioned within its focal window (16). The digitized output from the camera (12) is then stored on data storage media (32) together with other parameters inputted by a technician and relevant to the crystal specimen. Preferably, the digitized images are stored on removable media (32) while the parameters for different crystal specimens are maintained in a database (40) with indices to the digitized optical images on the other data storage media (32). Computer software is then utilized to identify not only the presence and number of crystals and the edges of the crystal specimens from the optical image, but to also rate the crystal specimens by various parameters, such as edge straightness, polygon formation, aspect ratio, surface clarity, crystal cracks and other defects or lack thereof, and other parameters relevant to the quality of the crystals.

Gester, Thomas E.↗

An imaging system for PLIF/Mie measurements for a combusting flow

The equipment required to establish an imaging system can be divided into four parts: (1) the light source and beam shaping optics; (2) camera and recording; (3) image acquisition and processing; and (4) computer and output systems. A pulsed, Nd:YAG-pummped, frequency-doubled dye laser which can freeze motion in the flowfield is used for an illumination source. A set of lenses is used to form the laser beam into a sheet. The induced fluorescence is collected by an UV-enhanced lens and passes through an UV-enhanced microchannel plate intensifier which is optically coupled to a gated solid state CCD camera. The output of the camera is simultaneously displayed on a monitor and recorded on either a laser videodisc set of a Super VHS VCR. This videodisc set is controlled by a minicomputer via a connection to the RS-232C interface terminals. The imaging system is connected to the host computer by a bus repeater and can be multiplexed between four video input sources. Sample images from a planar shear layer experiment are presented to show the processing capability of the imaging system with the host computer.

Wey, C. C.↗

Venus Aerobot Surface Science Imaging System (VASSIS)

The VASSIS task was to design and develop an imaging system and container for operation above the surface of Venus in preparation for a Discovery-class mission involving a Venus aerobot balloon. The technical goals of the effort were to: a) evaluate the possible nadir-viewed surface image quality as a function of wavelength and altitude in the Venus lower atmosphere, b) design a pressure vessel to contain the imager and supporting electronics that will meet the environmental requirements of the VASSIS mission, c) design and build a prototype imaging system including an Active-Pixel Sensor camera head and VASSIS-like optics that will meet the science requirements. The VASSIS science team developed a set of science requirements for the imaging system upon which the development work of this task was based.

Greeley, Ronald↗

Planetary Rover Localization Within Orbital Maps

This paper introduces an advanced rover localization system suitable for autonomous planetary exploration in the absence of Global Positioning System (GPS) infrastructure. Given an existing terrain map (image and elevation) obtained from satellite imagery and the images provided by the rover stereo camera system, the proposed method determines the best rover location through visual odometry, 3D terrain and hori- zon matching. The system is tested on data retrieved from a 3 km traverse of the Basalt Hills quarry in California where the GPS track is used as ground truth. Experimental results show the system presented here reduces by over 60 the localization error obtained by wheel odometry.

localization↗

Enhanced Video-Oculography System

A previously developed video-oculography system has been enhanced for use in measuring vestibulo-ocular reflexes of a human subject in a centrifuge, motor vehicle, or other setting. The system as previously developed included a lightweight digital video camera mounted on goggles. The left eye was illuminated by an infrared light-emitting diode via a dichroic mirror, and the camera captured images of the left eye in infrared light. To extract eye-movement data, the digitized video images were processed by software running in a laptop computer. Eye movements were calibrated by having the subject view a target pattern, fixed with respect to the subject s head, generated by a goggle-mounted laser with a diffraction grating. The system as enhanced includes a second camera for imaging the scene from the subject s perspective, and two inertial measurement units (IMUs) for measuring linear accelerations and rates of rotation for computing head movements. One IMU is mounted on the goggles, the other on the centrifuge or vehicle frame. All eye-movement and head-motion data are time-stamped. In addition, the subject s point of regard is superimposed on each scene image to enable analysis of patterns of gaze in real time.

Moore, Steven T.↗

Performance evaluation of the two-inch return-beam vidicon three-camera subsystem.

A very-high resolution multispectral television camera system is being developed for NASA for use on the Earth Resources Technology Satellite (ERTS) program. There are three cameras in the system, each viewing the same area but operating in the blue-green, red and near-infrared spectral bands. In the laboratory the cameras' limiting resolution is 4500 TV lines over the 25 x 25-mm image format of the Return Beam Vidicon (RBV). Analysis of typical ERTS scenes shows that actual contrast ratios will be much lower than those of laboratory test targets. A model was developed to predict the resolving power performance of the RBV camera under realistic conditions. The methods used are applicable to all types of imaging systems. To verify the model, tests were conducted using the RBV camera, a laser-beam image reproducer and a series of AF tribar test patterns of known values of contrast. As a more graphic demonstration, simulated multispectral images were generated using color-IR photographs from Apollo 9.

Miller, B. P.↗

Modified camera records lens settings on film

Camera is modified by inserting optical imaging system between lens and film. This system requires no electrical power, is low in weight, and adds nothing to external size of the camera.

Thompson, R. E.↗