Search NASA⌕ Search

SEARCH · Search NASA

Results for “Imaging simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

3D Monte Carlo simulation of backscattered electron signal variation across pore-solid boundaries in cement-based materials

Three-dimensional (3D) Monte Carlo simulation was used to study the variation of backscattered electron (BSE) signal across pore-solid boundaries in cement-based materials in order to enhance quantitative analysis of pore structure. The effects of pore size, depth and boundary inclination angle were investigated. It is found that pores down to 1 nm can generate sufficient contrast to be detected. Visibility improves with larger pore size, smaller beam probe size and lower acceleration voltage. However, pixels in shallow pores or near pore boundaries display higher grey values (brightness) than expected due to sampling sub-surface or neighbouring solid material. Thus, cement-based materials may appear less porous or the pores appear smaller than they actually are in BSE images. Simulated BSE images were used to test the accuracy of the Overflow pore segmentation method. Results show the method is generally valid and gives low errors for pores that are 1 μm and greater.

36 MATERIALS SCIENCE↗

Stereo image visualization of numerically simulated turbulence

Stereo imaging techniques are used in the current study to analyze the results of a direct Navier-Stokes simulation of a turbulent boundary layer. Coherent structures embedded within the unsteady, highly three-dimensional turbulent flow fields are significantly enhanced through the use of stereo computer graphic renderings. In the paper, the geometrical foundations of two different methods for generating stereo images are reviewed. Sufficient detail is provided to enable readers to code stereo display algorithms from scratch. The effects of varying the geometric parameters of the stereo algorithm are demonstrated. Sample image pairs from animations of the turbulence numerical simulation are presented in color. Stereo imagery, especially when used with time-evolving data, provides new insight into the physical processes responsible for the generation an maintenance of turbulence within boundary layers.

Robinson, Stephen K.↗

COSMIC SHEAR RESULTS FROM THE DEEP LENS SURVEY. I. JOINT CONSTRAINTS ON {Omega} {sub M} AND {sigma}{sub 8} WITH A TWO-DIMENSIONAL ANALYSIS

We present a cosmic shear study from the Deep Lens Survey (DLS), a deep BVRz multi-band imaging survey of five 4 deg{sup 2} fields with two National Optical Astronomy Observatory (NOAO) 4 m telescopes at Kitt Peak and Cerro Tololo. For both telescopes, the change of the point-spread-function (PSF) shape across the focal plane is complicated, and the exposure-to-exposure variation of this position-dependent PSF change is significant. We overcome this challenge by modeling the PSF separately for individual exposures and CCDs with principal component analysis (PCA). We find that stacking these PSFs reproduces the final PSF pattern on the mosaic image with high fidelity, and the method successfully separates PSF-induced systematics from gravitational lensing effects. We calibrate our shears and estimate the errors, utilizing an image simulator, which generates sheared ground-based galaxy images from deep Hubble Space Telescope archival data with a realistic atmospheric turbulence model. For cosmological parameter constraints, we marginalize over shear calibration error, photometric redshift uncertainty, and the Hubble constant. We use cosmology-dependent covariances for the Markov Chain Monte Carlo analysis and find that the role of this varying covariance is critical in our parameter estimation. Our current non-tomographic analysis alone constrains the {Omega} {sub M}-{sigma}{sub 8} likelihood contour tightly, providing a joint constraint of {Omega} {sub M} = 0.262 {+-} 0.051 and {sigma}{sub 8} = 0.868 {+-} 0.071. We expect that a future DLS weak-lensing tomographic study will further tighten these constraints because explicit treatment of the redshift dependence of cosmic shear more efficiently breaks the {Omega} {sub M}-{sigma}{sub 8} degeneracy. Combining the current results with the Wilkinson Microwave Anisotropy Probe 7 year (WMAP7) likelihood data, we obtain {Omega} {sub M} = 0.278 {+-} 0.018 and {sigma}{sub 8} = 0.815 {+-} 0.020.

79 ASTRONOMY AND ASTROPHYSICS↗

Automated Patient Identification and Localization Error Detection Using 2-Dimensional to 3-Dimensional Registration of Kilovoltage X-Ray Setup Images

Purpose: To determine whether kilovoltage x-ray projection radiation therapy setup images could be used to perform patient identification and detect gross errors in patient setup using a computer algorithm. Methods and Materials: Three patient cohorts treated using a commercially available image guided radiation therapy (IGRT) system that uses 2-dimensional to 3-dimensional (2D-3D) image registration were retrospectively analyzed: a group of 100 cranial radiation therapy patients, a group of 100 prostate cancer patients, and a group of 83 patients treated for spinal lesions. The setup images were acquired using fixed in-room kilovoltage imaging systems. In the prostate and cranial patient groups, localizations using image registration were performed between computed tomography (CT) simulation images from radiation therapy planning and setup x-ray images corresponding both to the same patient and to different patients. For the spinal patients, localizations were performed to the correct vertebral body, and to an adjacent vertebral body, using planning CTs and setup x-ray images from the same patient. An image similarity measure used by the IGRT system image registration algorithm was extracted from the IGRT system log files and evaluated as a discriminant for error detection. Results: A threshold value of the similarity measure could be chosen to separate correct and incorrect patient matches and correct and incorrect vertebral body localizations with excellent accuracy for these patient cohorts. A 10-fold cross-validation using linear discriminant analysis yielded misclassification probabilities of 0.000, 0.0045, and 0.014 for the cranial, prostate, and spinal cases, respectively. Conclusions: An automated measure of the image similarity between x-ray setup images and corresponding planning CT images could be used to perform automated patient identification and detection of localization errors in radiation therapy treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Direct imaging of light elements by annular dark-field aberration-corrected scanning transmission electron microscopy

In this report, we show that an annular dark-field detector in an aberration-corrected scanning transmission electron microscope allows the direct observation of light element columns in crystalline lattices. At specific imaging conditions, an enhancement of the intensities of light element columns in the presence of heavy element columns is observed. Experimental results are presented for imaging the nitrogen and carbon atomic columns at the GaN-SiC interface and within the GaN and SiC compounds. The crystal polarity of GaN at the interface is identified. The obtained findings are discussed and are well supported by image simulations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Modeling hydrodynamics, magnetic fields, and synthetic radiographs for high-energy-density plasma flows in shock-shear targets

Three-dimensional FLASH radiation-magnetohydrodynamics (radiation-MHD) modeling is carried out to study the hydrodynamics and magnetic fields in the shock-shear derived platform. Here, simulations indicate that fields of tens of Tesla can be generated via the Biermann battery effect due to vortices and mix in the counterpropagating shock-induced shear layer. Synthetic proton radiography simulations using MPRAD and synthetic X-ray image simulations using SPECT3D are carried out to predict the observable features in the diagnostics. Quantifying the effects of magnetic fields in inertial confinement fusion and high-energy-density plasmas represents frontier research that has far-reaching implications in basic and applied sciences.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Assessment of volumetric noise and resolution performance for linear and nonlinear CT reconstruction methods

Purpose: For nonlinear iterative image reconstructions (IR), the computed tomography (CT) noise and resolution properties can depend on the specific imaging conditions, such as lesion contrast and image noise level. Therefore, it is imperative to develop a reliable method to measure the noise and resolution properties under clinically relevant conditions. This study aimed to develop a robust methodology to measure the three-dimensional CT noise and resolution properties under such conditions and to provide guidelines to achieve desirable levels of accuracy and precision. Methods: The methodology was developed based on a previously reported CT image quality phantom. In this methodology, CT noise properties are measured in the uniform region of the phantom in terms of a task-based 3D noise-power spectrum (NPS{sub task}). The in-plane resolution properties are measured in terms of the task transfer function (TTF) by applying a radial edge technique to the rod inserts in the phantom. The z-direction resolution properties are measured from a supplemental phantom, also in terms of the TTF. To account for the possible nonlinearity of IR, the NPS{sub task} is measured with respect to the noise magnitude, and the TTF with respect to noise magnitude and edge contrast. To determine the accuracy and precision of the methodology, images of known noise and resolution properties were simulated. The NPS{sub task} and TTF were measured on the simulated images and compared to the truth, with criteria established to achieve NPS{sub task} and TTF measurements with <10% error. To demonstrate the utility of this methodology, measurements were performed on a commercial CT system using five dose levels, two slice thicknesses, and three reconstruction algorithms (filtered backprojection, FBP; iterative reconstruction in imaging space, IRIS; and sinogram affirmed iterative reconstruction with strengths of 5, SAFIRE5). Results: To achieve NPS{sub task} measurements with <10% error, the number of regions of interest needed to be greater than 65. To achieve TTF measurements with <10% error, the contrast-to-noise ratio of the edge needed to be ≥15, achievable by averaging multiple slices across the same edge. The NPS{sub task} measured on a commercial CT system showed IR's reduced noise (IRIS, 30% and SAFIRE5, 55%) and “waxier” texture (peak frequencies: FBP, 0.25 mm{sup −1}; IRIS, 0.23 mm{sup −1}; and SAFIRE5, 0.16 mm{sup −1}). The TTF measured within the axial plane showed improved in-plane resolution with SAFIRE5 at the TTF 50% frequency, f{sub 50} (FBP, 0.36–0.41 mm{sup −1}; SAFIRE5, 0.37–0.46 mm{sup −1}). The TTF measured along the axial direction showed improved z-direction resolution with thinner slice thickness (f{sub 50}: 0.6 mm, 0.35–0.79 mm{sup −1}; 1.5 mm, 0.22–0.3 mm{sup −1}) and with SAFIRE5 (f{sub 50}: FBP, 0.35–0.52 mm{sup −1}; SAFIRE5, 0.42–0.79 mm{sup −1}). Both in-plane and z-direction resolution of SAFIRE5 showed strong dependency on contrast, reflecting SAFIRE5's nonlinearity. Conclusions: A methodology was developed to measure three-dimensional CT noise and resolution properties for iterative reconstruction, especially at challenging measurement conditions with low contrast and high image noise. The methodology also demonstrated its utility for evaluating commercial CT systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WE-G-18A-01: JUNIOR INVESTIGATOR WINNER - Low-Dose C-Arm Cone-Beam CT with Model-Based Image Reconstruction for High-Quality Guidance of Neurosurgical Intervention

Purpose: To address the challenges of image quality, radiation dose, and reconstruction speed in intraoperative cone-beam CT (CBCT) for neurosurgery by combining model-based image reconstruction (MBIR) with accelerated algorithmic and computational methods. Methods: Preclinical studies involved a mobile C-arm for CBCT imaging of two anthropomorphic head phantoms that included simulated imaging targets (ventricles, soft-tissue structures/bleeds) and neurosurgical procedures (deep brain stimulation (DBS) electrode insertion) for assessment of image quality. The penalized likelihood (PL) framework was used for MBIR, incorporating a statistical model with image regularization via an edgepreserving penalty. To accelerate PL reconstruction, the ordered-subset, separable quadratic surrogates (OS-SQS) algorithm was modified to incorporate Nesterov's method and implemented on a multi-GPU system. A fair comparison of image quality between PL and conventional filtered backprojection (FBP) was performed by selecting reconstruction parameters that provided matched low-contrast spatial resolution. Results: CBCT images of the head phantoms demonstrated that PL reconstruction improved image quality (∼28% higher CNR) even at half the radiation dose (3.3 mGy) compared to FBP. A combination of Nesterov's method and fast projectors yielded a PL reconstruction run-time of 251 sec (cf., 5729 sec for OS-SQS, 13 sec for FBP). Insertion of a DBS electrode resulted in severe metal artifact streaks in FBP reconstructions, whereas PL was intrinsically robust against metal artifact. The combination of noise and artifact was reduced from 32.2 HU in FBP to 9.5 HU in PL, thereby providing better assessment of device placement and potential complications. Conclusion: The methods can be applied to intraoperative CBCT for guidance and verification of neurosurgical procedures (DBS electrode insertion, biopsy, tumor resection) and detection of complications (intracranial hemorrhage). Significant improvement in image quality, dose reduction, and reconstruction time of ∼4 min will enable practical deployment of low-dose C-arm CBCT within the operating room. AAPM Research Seed Funding (2013-2014); NIH Fellowship F32EB017571; Siemens Healthcare (XP Division)

60 APPLIED LIFE SCIENCES↗

Wide Field-of-View Soft X-Ray Imaging for Solar Wind-Magnetosphere Interactions

Soft X-ray imagers can be used to study the mesoscale and macroscale density structures that occur whenever and wherever the solar wind encounters neutral atoms at comets, the Moon, and both magnetized and unmagnetized planets. Charge exchange between high charge state solar wind ions and exospheric neutrals results in the isotropic emission of soft X-ray photons with energies from 0.1 to 2.0 keV. At Earth, this process occurs primarily within the magnetosheath and cusps. Through providing a global view, wide field-of-view imaging can determine the significance of the various proposed solar wind-magnetosphere interaction mechanisms by evaluating their global extent and occurrence patterns. A summary of wide field-of-view (several to tens of degrees) soft X-ray imaging is provided including slumped micropore microchannel reflectors, simulated images, and recent flight results.

xray↗

The LSST DESC DC2 Simulated Sky Survey

Here, we describe the simulated sky survey underlying the second data challenge (DC2) carried out in preparation for analysis of the Vera C. Rubin Observatory Legacy Survey of Space and Time (LSST) by the LSST Dark Energy Science Collaboration (LSST DESC). Significant connections across multiple science domains will be a hallmark of LSST; the DC2 program represents a unique modeling effort that stresses this interconnectivity in a way that has not been attempted before. This effort encompasses a full end-to-end approach: starting from a large N-body simulation, through setting up LSST-like observations including realistic cadences, through image simulations, and finally processing with Rubin's LSST Science Pipelines. This last step ensures that we generate data products resembling those to be delivered by the Rubin Observatory as closely as is currently possible. The simulated DC2 sky survey covers six optical bands in a wide-fast-deep area of approximately 300 deg 2 , as well as a deep drilling field of approximately 1 deg 2 . We simulate 5 yr of the planned 10 yr survey. The DC2 sky survey has multiple purposes. First, the LSST DESC working groups can use the data set to develop a range of DESC analysis pipelines to prepare for the advent of actual data. Second, it serves as a realistic test bed for the image processing software under development for LSST by the Rubin Observatory. In particular, simulated data provide a controlled way to investigate certain image-level systematic effects. Finally, the DC2 sky survey enables the exploration of new scientific ideas in both static and time domain cosmology.

79 ASTRONOMY AND ASTROPHYSICS↗

Enhanced phase contrast transfer using ptychography combined with a pre-specimen phase plate in a scanning transmission electron microscope

We report the ability to image light elements in both crystalline and noncrystalline materials at near atomic resolution with an enhanced contrast is highly advantageous to understand the structure and properties of a wide range of beam sensitive materials including biological specimens and molecular hetero-structures. This requires the imaging system to have an efficient phase contrast transfer at both low and high spatial frequencies. Here, we introduce a new phase contrast imaging method in a scanning transmission electron microscope (STEM) using a pre-specimen phase plate in the probe forming aperture, combined with a fast pixelated detector to record diffraction patterns at every probe position, and phase reconstruction using ptychography. The phase plate significantly enhances the contrast transfer of low spatial frequency information, and ptychography maximizes the extraction of the phase information at all spatial frequencies. In addition, the STEM probe with the presence of the phase plate retains its atomic resolution, allowing simultaneous incoherent Z-contrast imaging to be obtained along with the ptychographic phase image. An experimental image of Au nanoparticles on a carbon support shows high contrast for both materials. Multislice image simulations of a DNA molecule shows the capability of imaging soft matter at low dose conditions, which implies potential applications of low dose imaging of a wide range of beam sensitive materials.

36 MATERIALS SCIENCE↗

Imaging the earth's magnetosphere - Effects of plasma flow and temperature

The effects of Doppler shifting on the line centers of the magnetospheric O(+) cross section are investigated, and the resulting structure of the scattering rate as a function of bulk density is explained. Whereas the Doppler shifting frequently results in a decrease of the scattering rate, it is demonstrated that for certain drift speeds the overlap of the cross section and the solar intensity profile can lead to an increased rate, thus enhancing the relative brightness of the image above that obtained when v(p) is zero. Simulated images of the magnetosphere are obtained which are used to show quantitively how the magnetospheric image responds to variations in plasma drift speed and temperature. Changes in the brightness of the magnetospheric images also depend on the variability of the solar flux at 83.4 nm. In regions where there are plasma drifts, the brightness in the image is governed by the structure of the scattering rate, assuming a fixed temperature.

Garrido, D. E.↗

Quantitative assessment of the science return from an orbiting, imaging, optical interferometer

Imaging simulations were performed with the filled Mills cross orbiting, imaging, optical interferometer proposed by Synnott et al. (1990) in order to determine its capabilities in the area of spatial resolution, dynamic range, and sensitivity. Astronomical objects have been chosen as candidate program sources to determine whether this interferometer design can accomplish research goals relating to the objects.

Meier, David L.↗

Poster — Thur Eve — 14: Improving Tissue Segmentation for Monte Carlo Dose Calculation using DECT

Purpose: To improve Monte Carlo dose calculation accuracy through a new tissue segmentation technique with dual energy CT (DECT). Methods: Electron density (ED) and effective atomic number (EAN) can be extracted directly from DECT data with a stoichiometric calibration method. Images are acquired with Monte Carlo CT projections using the user code egs-cbct and reconstructed using an FDK backprojection algorithm. Calibration is performed using projections of a numerical RMI phantom. A weighted parameter algorithm then uses both EAN and ED to assign materials to voxels from DECT simulated images. This new method is compared to a standard tissue characterization from single energy CT (SECT) data using a segmented calibrated Hounsfield unit (HU) to ED curve. Both methods are compared to the reference numerical head phantom. Monte Carlo simulations on uniform phantoms of different tissues using dosxyz-nrc show discrepancies in depth-dose distributions. Results: Both SECT and DECT segmentation methods show similar performance assigning soft tissues. Performance is however improved with DECT in regions with higher density, such as bones, where it assigns materials correctly 8% more often than segmentation with SECT, considering the same set of tissues and simulated clinical CT images, i.e. including noise and reconstruction artifacts. Furthermore, Monte Carlo results indicate that kV photon beam depth-dose distributions can double between two tissues of density higher than muscle. Conclusions: A direct acquisition of ED and the added information of EAN with DECT data improves tissue segmentation and increases the accuracy of Monte Carlo dose calculation in kV photon beams.

07 ISOTOPE AND RADIATION SOURCES↗

Radar image enhancement and simulation as an aid to interpretation and training

Greatly increased activity in the field of radar image applications in the coming years demands that techniques of radar image analysis, enhancement, and simulation be developed now. Since the statistical nature of radar imagery differs from that of photographic imagery, one finds that the required digital image processing algorithms (e.g., for improved viewing and feature extraction) differ from those currently existing. This paper addresses these problems and discusses work at the Remote Sensing Laboratory in image simulation and processing, especially for systems comparable to the formerly operational SEASAT synthetic aperture radar.

Frost, V. S.↗

TH-CD-207A-08: Simulated Real-Time Image Guidance for Lung SBRT Patients Using Scatter Imaging

Purpose: To develop a comprehensive Monte Carlo-based model for the acquisition of scatter images of patient anatomy in real-time, during lung SBRT treatment. Methods: During SBRT treatment, images of patient anatomy can be acquired from scattered radiation. To rigorously examine the utility of scatter images for image guidance, a model is developed using MCNP code to simulate scatter images of phantoms and lung cancer patients. The model is validated by comparing experimental and simulated images of phantoms of different complexity. The differentiation between tissue types is investigated by imaging objects of known compositions (water, lung, and bone equivalent). A lung tumor phantom, simulating materials and geometry encountered during lung SBRT treatments, is used to investigate image noise properties for various quantities of delivered radiation (monitor units(MU)). Patient scatter images are simulated using the validated simulation model. 4DCT patient data is converted to an MCNP input geometry accounting for different tissue composition and densities. Lung tumor phantom images acquired with decreasing imaging time (decreasing MU) are used to model the expected noise amplitude in patient scatter images, producing realistic simulated patient scatter images with varying temporal resolution. Results: Image intensity in simulated and experimental scatter images of tissue equivalent objects (water, lung, bone) match within the uncertainty (∼3%). Lung tumor phantom images agree as well. Specifically, tumor-to-lung contrast matches within the uncertainty. The addition of random noise approximating quantum noise in experimental images to simulated patient images shows that scatter images of lung tumors can provide images in as fast as 0.5 seconds with CNR∼2.7. Conclusions: A scatter imaging simulation model is developed and validated using experimental phantom scatter images. Following validation, lung cancer patient scatter images are simulated. These simulated patient images demonstrate the clinical utility of scatter imaging for real-time tumor tracking during lung SBRT.

60 APPLIED LIFE SCIENCES↗

Simulations of muon imaging with the LANL GMT detector for spent nuclear fuel cask content verification

Atmospheric muons are typically high energy, highly penetrating charged particles. They interact with matter primarily through multiple Coulomb scatterings. Muon scattering intensities can be used to characterize the density and atomic number of the matter that they pass through. Previously, the Los Alamos National Laboratory (LANL) muon tomography team performed muon imaging of the partially filled MC-10 spent nuclear fuel (SNF) cask at Idaho National Laboratory (INL). This experiment demonstrated the feasibility of muon imaging for the verification of spent fuel container contents. That original effort used the mini muon tracker array, consisting of two arrays of drift tubes on either side of the SNF cask. The reconstructed image quality was limited by statistics, largely due to low muon flux at high zenith angles. A LANL led team will perform new measurements with a larger array, the Giant Muon Tracker (GMT), to improve data collection rates and statistics. In this work, simulations were performed with the GMT near the partially filled INL MC-10 cask. For more general fuel diversion detection, a full MC-10 cask and casks with a singular missing fuel bundle were also simulated. To understand minimum measurement times needed for missing bundle identification, 100 000 to millions of tracked muons (corresponding to 1.4 days to several weeks measurement time) were analyzed. Simulated images were then analyzed visually and numerically to explore techniques designed to minimize the collection time needed to identify the diversion of fuel in each scenario.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗