Search NASA⌕ Search

SEARCH · Search NASA

Results for “Initialization method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

A data-driven framework for sparsity-enhanced surrogates with arbitrary mutually dependent randomness

The challenge of quantifying uncertainty propagation in real-world systems is rooted in the high-dimensionality of the stochastic input and the frequent lack of explicit knowledge of its probability distribution. Traditional approaches show limitations for such problems, especially when the size of the training data is limited. To address these diculties, we have developed a general framework of constructing surrogate models on spaces of stochastic input with arbitrary probability measure irrespective of the mutual dependencies between individual components of the random inputs and the analytical form. The present Data-driven Sparsity-enhancing Rotation for Arbitrary Randomness (DSRAR) framework includes a data-driven construction of multivariate polynomial basis for arbitrary mutually dependent probability measure and a sparsity enhancement rotation procedure. This sparsity-enhancing rotation method was initially proposed in our previous work [1] for Gaussian density distributions, which may not be feasible for non-Gaussian distributions due to the loss of orthogonality after the rotation. To remedy such diculties, we developed a new data-driven approach to construct orthonormal polynomials for polynomials for arbitrary mutually dependent (amdP) randomness, ensuring the constructed basis maintains the orthogonality/near-orthogonality with respect to the density of the rotated random vector, where directly applying the regular polynomial chaos including arbitrary polynomial chaos (aPC) [2] shows limitations due to the assumption of the mutual independence between the components of the random inputs. The developed DSRAR framework leads to accurate recovery, with only limited training data, of a sparse representation of the target functions. The eectiveness of our method is demonstrated in challenging problems such as PDEs and realistic molecular systems within high-dimensional conformational space (O(10)) where the underlying density is implicitly represented by a large collection of sample data, as well as systems with explicitly given non-Gaussian probabilistic measures.

Lei, Huan↗

MO-G-304-02: Knowledge Based DVH Prediction Using a Geometric Dose Transform

Purpose: To demonstrate a novel method for predicting patient dose-volume histograms (DVHs) using a prior database of optimized radiotherapy treatment plans. Such predicted DVHs could be useful for automating treatment planning. Methods: Our initial demonstration utilized a database of 100 prostate intensity-modulated radiotherapy (IMRT) data-sets. Each data-set contained a CT image with contours of the planning target volume (PTV), rectum, and bladder, the parameters of a clinically approved IMRT plan, and a corresponding simulated dose distribution. We applied a novel geometric transformation to remove the influence of the PTV size, shape, and location on the dose distribution. We termed the transformed distribution the geometrically normalized dose distribution (GNDD). This normalization transform was applied to 80 data-sets randomly selected from the database, and a population GNDD was computed as the average. Next, the population GNDD was mapped onto each of the remaining 20 patient datasets using the reverse of the geometric normalization transform, and predicted DVHs were calculated from the reverse transformed dose distributions (GNDD-DVHs). In addition, a state of the art machine learning based method from the literature was tested for comparison. Results: DVH prediction accuracy was quantified by calculating the relative root mean squared error (rRMSE) on predicted DVHs for the 20 test patients using their known DVHs. For bladder, rectum, and PTV average rRMSEs for the GNDD method were 9.7 ± 4.2%, 13.9 ± 6.0%, and 2.3 ± 0.5% respectively. Prediction results using GNDD were roughly equivalent to that from the machine learning method. Conclusion: We developed a new method for predicting DVH curves from a database of prior patient plans. We demonstrated that our simple approach achieves accuracy comparable to a method using a complicated machine learning based approach.

60 APPLIED LIFE SCIENCES↗

Population of anatomically variable 4D XCAT adult phantoms for imaging research and optimization

Purpose: The authors previously developed the 4D extended cardiac-torso (XCAT) phantom for multimodality imaging research. The XCAT consisted of highly detailed whole-body models for the standard male and female adult, including the cardiac and respiratory motions. In this work, the authors extend the XCAT beyond these reference anatomies by developing a series of anatomically variable 4D XCAT adult phantoms for imaging research, the first library of 4D computational phantoms. Methods: The initial anatomy of each phantom was based on chest-abdomen-pelvis computed tomography data from normal patients obtained from the Duke University database. The major organs and structures for each phantom were segmented from the corresponding data and defined using nonuniform rational B-spline surfaces. To complete the body, the authors manually added on the head, arms, and legs using the original XCAT adult male and female anatomies. The structures were scaled to best match the age and anatomy of the patient. A multichannel large deformation diffeomorphic metric mapping algorithm was then used to calculate the transform from the template XCAT phantom (male or female) to the target patient model. The transform was applied to the template XCAT to fill in any unsegmented structures within the target phantom and to implement the 4D cardiac and respiratory models in the new anatomy. Each new phantom was refined by checking for anatomical accuracy via inspection of the models. Results: Using these methods, the authors created a series of computerized phantoms with thousands of anatomical structures and modeling cardiac and respiratory motions. The database consists of 58 (35 male and 23 female) anatomically variable phantoms in total. Like the original XCAT, these phantoms can be combined with existing simulation packages to simulate realistic imaging data. Each new phantom contains parameterized models for the anatomy and the cardiac and respiratory motions and can, therefore, serve as a jumping point from which to create an unlimited number of 3D and 4D variations for imaging research. Conclusions: A population of phantoms that includes a range of anatomical variations representative of the public at large is needed to more closely mimic a clinical study or trial. The series of anatomically variable phantoms developed in this work provide a valuable resource for investigating 3D and 4D imaging devices and the effects of anatomy and motion in imaging. Combined with Monte Carlo simulation programs, the phantoms also provide a valuable tool to investigate patient-specific dose and image quality, and optimization for adults undergoing imaging procedures.

60 APPLIED LIFE SCIENCES↗

Single institutional experience with initial ultrasound followed by computed tomography or magnetic resonance imaging for acute appendicitis in adults

Purpose: The objectives of this study was to assess the performance of ultrasound (US) for suspected appendicitis in adult patients and to evaluated the additive value of short-interval (within 1 week) computed tomography (CT) or Magnetic Resonance Imaging (MRI) after performing an initial US. Methods: In this IRB-approved, HIPAA-compliant, retrospective study, electronic medical records (EMRs) were queried for “US appendicitis” performed over a 2-year interval. EMR was reviewed for CT or MRI performed within 1 week of this exam, and if any new or additional information was available at subsequent exam. White count, patient disposition, and pathology, if surgery was performed, were also recorded. Results: 682 patients underwent US for appendicitis over a 2-year duration, age range from 18 to 92 years (average: 30.1 years, M:F = 141:541). Findings showed 126/682 patients with normal appendix, 75/682 uncomplicated appendicitis, and 4/682 with complicated appendicitis. When performed, no additional findings were seen in these groups on short-interval CT or MRI. 2/682 patients had equivocal findings on US but eventually had normal appendix identified on CT. Four hundred and seventy-three patients had non-visualized appendix, of which only 14/473 (3.1%) eventually had appendicitis. Conclusions: Ultrasound is an effective initial modality for evaluating appendicitis even in adult patients. Once a normal appendix, uncomplicated or complicated appendicitis is identified on US, no further imaging is necessary. Very few patients with non-visualization of the appendix eventually have appendicitis. Hence, these patients can be managed with active clinical follow-up rather than immediate CT or MRI. Symptoms and clinical scoring systems can be used for triage of these patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-48: Automated Quality Assurance for XML Controlled Linacs

Purpose: To automate routine imaging QA procedures so that complying with TG 142 and TG 179 can be efficient and reliable. Methods: Two QA tests for a True Beam Linac were automatized. A Winston Lutz test as described by Lutz et al{sup 1} using the Winston Lutz test kit from BrainLab, Germany and a CBCT Image Quality test as described in TG 179 using the EMMA phantom, Siemens Medical Physics, Germany were performed in our True Beam. For each QA procedure tested, a 3 step paradigm was used. First, the data was automatically acquired using True Beam Developer Mode and XML scripting. Second, the data acquired in the first step was automatically processed using in-home grown Matlab GUIs. Third, Machine Learning algorithms were used to automatically classify the processed data and reports generated. Results: The Winston Luzt test could be performed by an experienced medical physicist in 29.0 ± 8.0 min. The same test, if automated using our paradigm, could be performed in 3.0 ± 0.1 min. In the same lieu, time could be substantially saved for image quality tests. In this case, the amount of time saved will depend on the phantoms used and the initial localization method. Additionally, machine learning algorithms could automatically identify the roots of the problems if any and possibly help reduce machine down time. Conclusion: Modern linear accelerators are equipped with advanced 2D and 3D imaging that are used for patient alignment substantially improving IGRT protocols. However, this extra complexity exponentially increases the number of QA tests needed. Using the new paradigm described above, not only bare minimum but best practice QA programs could be implemented with the same manpower. This work is supported by Varian, Palo Alto, CA.

60 APPLIED LIFE SCIENCES↗

MO-H-19A-02: Investigation of Modulated Electron Arc (MeArc) Therapy for the Treatment of Scalp Tumors

Purpose: Electron arc therapy has long been proposed as the most suitable technique for the treatment of superficial tumors that follow circularly curved surfaces. However it was challenged by unsuitability of the conventional applicators and the lack of adequate 3-D dose calculation tools for arc electron beams in the treatment planning systems (TPS). Now with the availability of an electron specific multi-leaf collimator (eMLC) and an in-house Monte Carlo (MC) based TPS, we were motivated to investigate more advanced modulated electron arc (MeARC) therapy and its beneficial outcome. Methods: We initiated the study by a film measurement conducted in a head and neck phantom, where we delivered electron arcs in a step and shoot manner using the light field as a guide to avoid fields abutments. This step was done to insure enough clearance for the arcs with eMLC. MCBEAM and MCPLAN MC codes were used for the treatment head simulation and phantom dose calculation, respectively. Treatment plans were generated for targets drawn in real patient CTs and head and neck phantom. We utilized beams eye view available from a commercial planning system to create beamlets having same isocenter and adjoined at the scalp surface. Then dose-deposition coefficients from those beamlets were calculated for all electron energies using MCPLAN. An in-house optimization code was then used to find the optimum weights needed from individual beamlets. Results: MeARC showed a nicely tailored dose distribution around the circular curved target on the scalp. Some hot spots were noticed and could be attributed to fields abutment problem owing to the bulging nature of electron profiles. Brain dose was shown to be at lower levels compared to photon treatment. Conclusion: MeARC was shown to be a promising modality for treating scalp cases and could be beneficial to all superficial tumors with a circular curvature.

60 APPLIED LIFE SCIENCES↗

SU-E-T-111: An Iterative Approach to Modelling Dosimetric Properties of a Varian MLC

Purpose: In effort to efficiently and accurately model MLC parameters for use in Varian Eclipse treatment planning system (TPS), an iterative technique for characterizing the dosimetric properties of MLCs has been developed. Methods: The initial characterization of the dosimetric leaf gap (DLG) and MLC transmission was performed using varied sizes of moving gaps and transmission measurements through central axis of the radiation beam. These values were determined during the initial data collection. After the initial values were determined and entered into the TPS, two plans were calculated to test the veracity of DLG and transmission independently. The plan used to determine the DLG has openings of varied sizes which are affected differently by the DLG. A large field uniform fluence that required a MLC carriage shift was used to determine the transmission value independent of DLG. After characterizing the dosimetric properties of the MLC independently, clinical IMRT plans were tested and used to tweak the final values. Results: This approach to modelling MLC dosimetric properties was employed for: standard 120 leaf MLC (SDMLC) and 120 leaf high definition MLC (HDMLC). Both types were successfully commissioned, tested, and approved for clinical use on 4 SDMLC machines and 2 HDMLC machines. The pass rate of clinical IMRT plans was 96.9% for 6MV and 98.3% for 10MV for SDMLC and 96.3% for 6MV, 96.5% for 6FFF, and 97.5% for 10FFF for HDMLCs using MapCheck2 with gamma analysis of 2%/2mm and 10% threshold. The final DLG and transmission parameters for 6X were 0.5mm and 0.01, and 1.35mm and 0.02 for HD and SD MLCs respectively. Conclusion: This iterative approach of determining dosimetric properties of MLCs is viable for both SDMLC and HDMLC and multiple energies. This approach accurately and efficiently determines the values needed for commissioning MLCs when they are employed for modulated therapies.

60 APPLIED LIFE SCIENCES↗

Study of ice cluster impacts on amorphous silica using the ReaxFF reactive force field molecular dynamics simulation method

We study the dynamics of the collisions between amorphous silica structures and amorphous and crystal ice clusters with impact velocities of 1 km/s, 4 km/s, and 7 km/s using the ReaxFF reactive molecular dynamics simulation method. The initial ice clusters consist of 150 water molecules for the amorphous ice cluster and 128 water molecules for the crystal ice cluster. The ice clusters are collided on the surface of amorphous fully oxidized and suboxide silica. These simulations show that at 1 km/s impact velocities, all the ice clusters accumulate on the surface and at 4 km/s and 7 km/s impact velocities, some of the ice cluster molecules bounce back from the surface. At 4 km/s and 7 km/s impact velocities, few of the water molecules dissociations are observed. The effect of the second ice cluster impacts on the surfaces which are fully covered with ice, on the mass loss/accumulation is studied. These studies show that at 1 km/s impacts, the entire ice cluster accumulates on the surface at both first and second ice impacts. At higher impact velocities, some ice molecules which after the first ice impacts have been attached to the surface will separate from the surface after the second ice impacts at 7 km/s impact velocity. For the 4 km/s ice cluster impact, ice accumulation is observed for the crystal ice cluster impacts and ice separation is observed for the amorphous ice impacts. Observing the temperatures of the ice clusters during the collisions indicates that the possibility of electron excitement at impact velocities less than 10 km/s is minimal and ReaxFF reactive molecular dynamics simulation can predict the chemistry of these hypervelocity impacts. However, at impact velocities close to 10 km/s the average temperature of the impacting ice clusters increase to about 2000 K, with individual molecules occasionally reaching temperatures of over 8000 K and thus it will be prudent to consider the concept of electron excitation at these higher impact velocities, which goes beyond the current ReaxFF ability.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Collimator design for a dedicated molecular breast imaging-guided biopsy system: Proof-of-concept

Purpose: Molecular breast imaging (MBI) is a dedicated nuclear medicine breast imaging modality that employs dual-head cadmium zinc telluride (CZT) gamma cameras to functionally detect breast cancer. MBI has been shown to detect breast cancers otherwise occult on mammography and ultrasound. Currently, a MBI-guided biopsy system does not exist to biopsy such lesions. Our objective was to consider the utility of a novel conical slant-hole (CSH) collimator for rapid (<1 min) and accurate monitoring of lesion position to serve as part of a MBI-guided biopsy system. Methods: An initial CSH collimator design was derived from the dimensions of a parallel-hole collimator optimized for MBI performed with dual-head CZT gamma cameras. The parameters of the CSH collimator included the collimator height, cone slant angle, thickness of septa and cones of the collimator, and the annular areas exposed at the base of the cones. These parameters were varied within the geometric constraints of the MBI system to create several potential CSH collimator designs. The CSH collimator designs were evaluated using Monte Carlo simulations. The model included a breast compressed to a thickness of 6 cm with a 1-cm diameter lesion located 3 cm from the collimator face. The number of particles simulated was chosen to represent the count density of a low-dose, screening MBI study acquired with the parallel-hole collimator for 10 min after a {approx}150 MBq (4 mCi) injection of Tc-99m sestamibi. The same number of particles was used for the CSH collimator simulations. In the resulting simulated images, the count sensitivity, spatial resolution, and accuracy of the lesion depth determined from the lesion profile width were evaluated. Results: The CSH collimator design with default parameters derived from the optimal parallel-hole collimator provided 1-min images with error in the lesion depth estimation of 1.1 {+-} 0.7 mm and over 21 times the lesion count sensitivity relative to 1-min images acquired with the current parallel-hole collimator. Sensitivity was increased via more vertical cone slant angles, larger annular areas, thinner cone walls, shorter cone heights, and thinner radiating septa. Full width at half maximum trended in the opposite direction as sensitivity for all parameters. There was less error in the depth estimates for less vertical slant angles, smaller annular areas, thinner cone walls, cone heights near 1 cm, and generally thinner radiating septa. Conclusions: A Monte Carlo model was used to demonstrate the feasibility of a CSH collimator design for rapid biopsy application in molecular breast imaging. Specifically, lesion depth of a 1-cm diameter lesion positioned in the center of a typical breast can be estimated with error of less than 2 mm using circumferential count profiles of images acquired in 1 min.

60 APPLIED LIFE SCIENCES↗

Chemical Vapor Deposition of Monolayer Rhenium Disulfide (ReS 2 )

A direct synthesis of monolayer and multilayer ReS 2 by chemical vapor deposition at a low temperature of 450 °C is reported. We performed a detailed characterization of this material using various spectroscopy and microscopy methods. Furthermore initial field-effect transistor characteristics are evaluated, which highlight the potential in being used as an n-type semiconductor.

2D materials↗

The Synthesis, Characterization and Dehydrogenation of Sigma-Complexes of BN-Cyclohexanes

The coordination chemistry of the 1,2-BN-cyclohexanes 2,2-R 2 -1,2-B,N-C 4 H 10 (R 2 =HH, MeH, Me 2 ) with Ir and Rh metal fragments has been studied. This led to the solution (NMR spectroscopy) and solid-state (X-ray diffraction) characterization of [Ir(PCy 3 ) 2 (H) 2 (η 2 η 2 -H 2 BNR 2 C 4 H 8 )][BAr F 4 ] (NR 2 =NH 2 , NMeH) and [Rh( i Pr 2 PCH 2 CH 2 CH 2 P i Pr 2 )(η 2 η 2 -H 2 BNR 2 C 4 H 8 )][BAr F 4 ] (NR 2 =NH 2 , NMeH, NMe 2 ). For NR 2 =NH 2 subsequent metal-promoted, dehydrocoupling shows the eventual formation of the cyclic tricyclic borazine [BNC 4 H 8 ] 3 , via amino-borane and, tentatively characterized using DFT/GIAO chemical shift calculations, cycloborazane intermediates. For NR 2 =NMeH the final product is the cyclic amino-borane HBNMeC 4 H 8 . The mechanism of dehydrogenation of 2,2-H,Me-1,2-B,N-C 4 H 10 using the {Rh( i Pr 2 PCH 2 CH 2 CH 2 P i Pr 2 )} + catalyst has been probed. Catalytic experiments indicate the rapid formation of a dimeric species, [Rh 2 ( i Pr 2 PCH 2 CH 2 CH 2 P i Pr 2 ) 2 H 5 ][BAr F 4 ]. Using the initial rate method starting from this dimer, a first-order relationship to [amine-borane], but half-order to [Rh] is established, which is suggested to be due to a rapid dimer–monomer equilibrium operating.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sensitivity of Fine‐Resolution Urban Heat Island Simulations to Soil Moisture Parameterization

ABSTRACT Urban areas experience the impact of natural disasters, such as heatwaves and flash floods, disparately in different neighbourhoods across a city. The demand for precise urban hydrometeorological and hydroclimatological modelling to examine this disparity, and the interacting challenges posed by climate change and urbanisation, has thus surged. The Weather Research and Forecasting (WRF) model has served such operational and research purposes for decades. Recent advancements in WRF, including enhanced numerical schemes and sophisticated urban atmospheric‐hydrological parameterizations, have empowered the simulation of urban geophysical processes at high resolution (~1 km), but even this resolution misses significant urban microclimate variability. This study applies the large‐eddy simulations (LES) mode within WRF, coupled with single‐layer urban canopy models (SLUCM), to enable even finer‐scale modelling (150 m) of the Urban Heat Island (UHI) effect in the Baltimore metropolitan area. We run nine scenarios to evaluate various methods of initializing soil moisture and various spinup lead times, and to assess the impact of WRF's Mosaic approach in depicting subgrid‐scale processes. We evaluate the scenarios by comparing the WRF simulated land surface temperature (LST) against Landsat LST and the WRF simulated hourly 2‐m air temperatures (AT) with observations from eight weather stations across the domain. Results underscore the paramount influence of the lead spinup time on the spatiotemporal distribution of simulated soil moisture, consequently shaping WRF's efficacy in predicting the UHI. Furthermore, interpolating soil moisture‐related parameters from the parent for child domain initialization yields a notable reduction in mean and root‐mean‐squared errors. This improvement was particularly evident in simulations with the longest spinup time, affirming the importance of carefully designing the initialization of soil moisture for improved urban temperature predictions.

Talebpour, Mahdad↗

Improved subseasonal-to-seasonal precipitation prediction of climate models with nudging approach for better initialization of Tibetan Plateau-Rocky Mountain Circumglobal wave train and land surface conditions

Abstract Reliable subseasonal-to-seasonal (S2S) precipitation prediction is highly desired due to the great socioeconomical implications, yet it remains one of the most challenging topics in the weather/climate prediction research area. As part of the Impact of Initialized Land Temperature and Snowpack on Sub-seasonal to Seasonal Prediction (LS4P) project of the Global Energy and Water Exchanges (GEWEX) program, twenty-one climate models follow the LS4P protocol to quantify the impact of the Tibetan Plateau (TP) land surface temperature/subsurface temperature (LST/SUBT) springtime anomalies on the global summertime precipitation. We find that nudging towards reanalysis winds is crucial for climate models to generate atmosphere and land surface initial conditions close to observations, which is necessary for meaningful S2S applications. Simulations with nudged initial conditions can better capture the summer precipitation responses to the imposed TP LST/SUBT spring anomalies at hotspot regions all over the world. Further analyses show that the enhanced S2S prediction skill is largely attributable to the substantially improved initialization of the Tibetan Plateau-Rocky Mountain Circumglobal (TRC) wave train pattern in the atmosphere. This study highlights the important role that initial condition plays in the S2S prediction and suggests that data assimilation technique (e.g., nudging) should be adopted to initialize climate models to improve their S2S prediction.

54 ENVIRONMENTAL SCIENCES↗

Gold nanoparticles in reverse micellar solutions: preparation, optical properties, and dimensional characteristics

Gold nanoparticles (NPs) were synthesized via chemical (Chem) and radiation-chemical (RadChem) methods for the reduction of ions in reverse micellar solutions (RMS). The gold NP have for the first time been obtained by self-organization (Self-assembly), and their optical properties were evaluated. The formation of Au NP (Chem, RadChem, and Self) was confirmed by the transmission electron microscopy. The spectral characteristics of optical absorption of gold NP in the RMS depend on the solubilization coefficient ω, the salt concentration, and the methods for initiating the primary steps of reduction reactions responsible for the formation of nanoscale structures.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Formation and Transportation of an Intense Sub-Millisecond Electron Beam in a Longitudinal Magnetic Field in the Source with a Mesh Plasma Cathode

The limiting parameters of an intense sub-millisecond electron beam generated in the source with a plasma cathode on the basis of a low-pressure multi-arc discharge with mesh stabilization of the cathode (emission) plasma boundary and mobile anode (beam) plasma boundary are investigated. It is demonstrated that the limiting parameters of the electron beam in the examined electrode system are limited by its energy content on a level of about 4 kJ the excess of which leads to an electric breakdown of the accelerating gap. The optimal pressures are determined at which the beam during its transportation in the longitudinal magnetic field with a preset configuration has maximal parameters for the given electrode system. Different mechanisms of electric breakdown initiation and methods for increasing the electric strength of the high-voltage accelerating gap in this electrode system are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A numerical study of transient ignition and flame characteristics of diluted hydrogen versus heated air in counterflow.

Combined experimental and numerical studies of the transient response of ignition to strained flows require a well-characterized ignition trigger. Laser deposition of a small radical pool provides a reliable method for initiating ignition of mixtures that are near the ignition limit. Two-dimensional direct numerical simulations are used to quantify the sensitivity of ignition kernel formation and subsequent edge-flame propagation to the oxidizer temperature and the initial width and amplitude of O-atom deposition used to trigger ignition in an axisymmetric counterflow of heated air versus ambient hydrogen/nitrogen. The ignition delay and super-equilibrium OH concentration in the nascent ignition kernel are highly sensitive to variations in these initial conditions. The ignition delay decreases as the amplitude of the initial O-atom deposition increases. The spatial distribution and the magnitude of the OH overshoot are governed by multi-dimensional effects. The degree of OH overshoot near the burner centerline increases as the diameter of the initial O-atom deposition region decreases. This result is attributed to preferential diffusion of hydrogen in the highly curved leading portion of the edge flame that is established following thermal runaway. The edge-flame speed and OH overshoot at the leading edge of the edge flame are relatively insensitive to variations in the initial conditions of the ignition. The steady edge-flame speed is approximately twice the corresponding laminar flame speed. The rate at which the edge flame approaches its steady state is insensitive to the initial conditions and depends solely on the diffusion time scale at the edge flame. The edge flame is curved toward the heated oxidizer stream as a result of differences in the chemical kinetics between the leading edge and the trailing diffusion flame. The structure of the highly diluted diffusion flame considered in this study corresponds to Linan's 'premixed flame regime' in which only the oxidizer leaks through the reaction zone such that the flame is located at fuel lean rather than stoichiometric mixture fraction conditions.

08 HYDROGEN↗

Does Incidental Irradiation With Doses Below 50 Gy Effectively Reduce Isolated Nodal Failures in Non-Small-Cell Lung Cancer: Dose-Response Relationship

Purpose: To evaluate the dose-response relationship for a wide range of doses lower than 50 Gy delivered to the hilar and mediastinal lymph node stations from incidental irradiation in 220 patients with non-small-cell lung cancer (NSCLC) treated with three-dimensional conformal radiotherapy. The endpoint was isolated nodal recurrence (INR) in stations that were initially negative. Methods and Materials: The individual responses of 2596 nodal stations were analyzed. Different fractionation schedules were used in different patients. Total prescribed tumor doses ranged from 52 Gy to 74 Gy given over 16-56 days. There were 1198 nodal stations (46%) within and 1398 stations beyond the elective nodal irradiation (ENI) volumes. The INR incidence was estimated for six dose levels ranging from 5 {+-} 5 Gy to {>=}56 Gy. Results: There were a total of 25 INRs in 17 patients (8%). The incidence of INR within the electively treated volumes was 0.58%, compared with 1.28% in nodal stations beyond the ENI. Almost 80% of the INRs occurred during 10 months of follow-up. A strong dose-response relationship was seen for the lower 'incidental' doses, most of which were less than 50 Gy. As the dose increased from 5 {+-} 5 Gy to 40 {+-} 5 Gy, the rate of freedom from INR increased from 12% to 76% (p = 0.005). Conclusions: There is evidence of a dose-response relationship between a reduction in the rate of INR and doses lower than 50 Gy. This suggests that incidental irradiation can eradicate at least some subclinical metastases in regional lymph nodes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of Radiotherapy on Fertility, Pregnancy, and Neonatal Outcomes in Female Cancer Patients

Purpose: Radiation has many potential long-term effects on cancer survivors. Female cancer patients may experience decreased fertility depending on the site irradiated. Oncologists should be aware of these consequences and discuss options for fertility preservation before initiating therapy. Methods and Materials: A comprehensive review of the existing literature was conducted. Studies reporting the outcomes for female patients treated with cranio-spinal, abdominal, or pelvic radiation reporting fertility, pregnancy, or neonatal-related outcomes were reviewed. Results: Cranio-spinal irradiation elicited significant hormonal changes in women that affected their ability to become pregnant later in life. Women treated with abdomino-pelvic radiation have an increased rate of uterine dysfunction leading to miscarriage, preterm labor, low birth weight, and placental abnormalities. Early menopause results from low-dose ovarian radiation. Ovarian transposition may decrease the rates of ovarian dysfunction. Conclusions: There is a dose-dependent relationship between ovarian radiation therapy (RT) and premature menopause. Patients treated with RT must be aware of the impact of treatment on fertility and explore appropriate options.

62 RADIOLOGY AND NUCLEAR MEDICINE↗