Search NASA⌕ Search

SEARCH · Search NASA

Results for “Instrument Procedures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Satellite/rocket ozone comparisons at Natal, Brazil

Comparisons are presented of satellite, rocket, and balloon ozone profiles near Natal, Brazil (5.9 deg S, 35.2 deg W). The low variability of stratospheric ozone at Natal during March and April of 1985 has allowed intercomparisons of reasonably large data sets, rather than a small number of paired satellite/in situ comparisons. There are sharp differences between the profile from the SBUV instrument on Nimbus 7 and the in situ measurements. These results support the conclusions of the NASA Ozone Trends Panel that there is an instrumental cause for the very large changes in upper stratospheric ozone seen by SBUV. Along with other comparisons, these results are being used in a reassessment of the SBUV instrument and its data reduction procedures. The agreement between the ozone profiles from the SAGE II instrument on the ERBS satellite and the rocket values is excellent over the full range of comparisons. Both SAGE II and ROCOZ-A must convert from altitude to pressure for intercomparisons with SME and with SBUV-type instruments. The conversion between pressure and altitude is as important as the ozone measurements, especially in the upper stratosphere where the scale height for ozone is approximately half that for pressure.

Barnes, Robert A.↗

Millimeter-wave ozone measurements for the network for the detection of stratospheric change

The primary research objective is to initiate long-term monitoring of stratospheric ozone with a ground-based millimeter-wave spectrometer, the first of several such instruments projected to be part of the Network for the Detection of Stratospheric Change. The ultimate goal of this monitoring is twofold. First, to detect any secular trend in stratospheric ozone abundance, whether of natural or anthropogenic origin and, second, to provide ground-truth validation for existing and future satellite measurements of ozone. With this goal in mind, a more immediate objective is to validate the millimeter-wave measurements by tests of the instrument, internal consistency tests on the data, and most importantly, by intercomparison with all other available ozone measurements. The validation process is expected to lead to refinements in the instrument and its operating procedures and in the data analysis. The final objective is to perform short-term scientific studies with the data, including studies of the ozone diurnal and seasonal variations, and comparison of ozone variations with changes in other geophysical parameters, notably temperature and water vapor. Routine observations are now ongoing; these will allow continuing intercomparisons with the Stratospheric Aerosol and Gas Experiment (SAGE II) and one of the lidars, which is permanently on site. The experience gained during the Stratospheric Ozone Intercomparison (STOIC) caused us to refine our calibration procedures and identify the need for internal shielding of the millimeter receiver from radio frequency interference. Installation of this shielding is planned for the near future and should allow improvements in the instrument calibration and a higher signal-to-noise ratio, both of which will result in improved measurement precision.

Connor, Brian J.↗

First Reprocessing of Southern Hemisphere ADditional OZonesondes (SHADOZ) Profile Records (1998-2015): 1. Methodology and Evaluation

Electrochemical concentration cell ozonesonde measurements are an important source of highly resolved vertical profiles of ozone with long-term data records for deriving ozone trends, model development, satellite validation, and air quality studies. Ozonesonde stations employ a range of operational and data processing procedures, metadata reporting, and instrument changes that have resulted in inhomogeneities within individual station data records. A major milestone is the first reprocessing of seven Southern Hemisphere ADditional OZonesondes (SHADOZ) station ozonesonde records to account for errors and biases in operating/processing procedures. Ascension Island, Hanoi, Irene, Kuala Lumpur, La Reunion, Natal, and Watukosek station records all show an overall increase in ozone after reprocessing. Watukosek shows the largest increase of 9.0 plus or minus 2.1 Dobson Units (DU) in total column ozone; Irene and Hanoi show a 5.5 plus or minus 2.5 DU increase, while remaining sites show statistically insignificant enhancements. Negligible to modest ozone enhancements are observed after reprocessing in the troposphere (up to 8%) and stratosphere (up to 6%), except at La Reunion for which the application of background currents reduces tropospheric ozone (2.1 plus or minus1.3 DU). Inhomogeneities due to ozonesonde/solution-type changes at Ascension, Natal, and La Reunion are resolved with the application of transfer functions. Comparisons with EP-TOMS, Aura's Ozone Monitoring Instrument and Microwave Limb Sounder (MLS) satellite ozone overpasses show an overall improvement in agreement after reprocessing. Most reprocessed data sets show a significant reduction in biases with MLS at the ozone maximum region (50-10 hPa). Changes in radiosonde/ozonesonde system and nonstandard solution types can account for remaining discrepancies observed at several sites when compared to satellites.

Electrochemical concentration cell ozonesonde meas↗

Dental equipment test during zero-gravity flight

The overall objectives of this program were to establish performance criteria and develop prototype equipment for use in the Health Maintenance Facility (HMF) in meeting the needs of dental emergencies during space missions. The primary efforts during this flight test were to test patient-operator relationships, patent (manikin) restraint and positioning, task lighting systems, use and operation of dental rotary instruments, suction and particle containment system, dental hand instrument delivery and control procedures, and the use of dental treatment materials. The initial efforts during the flight focused on verification of the efficiency of the particle containment system. An absorptive barrier was also tested in lieu of the suction collector. To test the instrument delivery system, teeth in the manikin were prepared with the dental drill to receive restorations, some with temporary filling materials and another with definitive filling material (composite resin). The best particle containment came from the combination use of the laminar-air/suction collector in concert with immediate area suction from a surgical high-volume suction tip. Lighting in the treatment area was provided by a flexible fiberoptic probe. This system is quite effective for small areas, but for general tasks ambient illumination is required. The instrument containment system (elastic cord network) was extremely effective and easy to use. The most serious problem with instrument delivey and actual treatment was lack of time during the microgravity sequences. The restorative materials handled and finished well.

Young, John↗

Simulation studies of air transport operational problems

An experimental evaluation of the monitored approach procedure for conducting low visibility instrument approaches is described. Four airline crews each flew 16 approaches using the monitored procedure and 16 using a modified standard procedure in a DC-10 simulator under various conditions of visibility, wind shear and turbulence, and radar vectoring scenarios. In terms of system measures of aircrew performance, no major differences were found. Pilot opinion data indicate that there are some desirable characteristics of the monitored procedure, particularly with reference to the increased role of the flight engineer in conducting low visibility approaches. Rationale for developing approach procedures is discussed.

Lauber, J. K.↗

A pilot's opinion - VTOL control design requirements for the instrument approach task.

This paper presents pilot opinion supported by test data concerning flight control and display concepts and control system design requirements for VTOL aircraft in the instrument approach task. Material presented is drawn from research flights in the following aircraft: Dornier DO-31, Short SC-1, LTV XC-142A, and Boeing-Vertol CH-46. The control system concepts and mechanizations employed in the above aircraft are discussed, and the effect of control system augmentation is shown on performance. Operational procedures required in the instrument approach task are described, with comments on need for automation and combining of control functions.

Patton, J. M., Jr.↗

Design, Build, and Initial Testing of a Portable Methane Measurement Platform

The quantification of methane concentrations in air is essential for the quantification of methane emissions, which in turn is necessary to determine absolute emissions and the efficacy of emission mitigation strategies. These are essential if countries are to meet climate goals. Large-scale deployment of methane analyzers across millions of emission sites is prohibitively expensive, and lower-cost instrumentation has been recently developed as an alternative. Currently, it is unclear how cheaper instrumentation will affect measurement resolution or accuracy. To test this, the Wireless Autonomous Transportable Methane Emission Reporting System (WATCH 4 ERS) has been developed, comprising four commercially available sensing technologies: metal oxide (MOx,), Non-dispersion Infrared (NDIR), integrated infrared (INIR), and tunable diode laser absorption spectrometer (TDLAS). WATCHERS is the accumulated knowledge of several long-term methane measurement projects at Colorado State University’s Methane Emission Technology Evaluation Center (METEC), and this study describes the integration of these sensors into a single unit and reports initial instrument response to calibration procedures and controlled release experiments. Specifically, this paper aims to describe the development of the WATCH 4 ERS unit, report initial sensor responses, and describe future research goals. Meanwhile, future work will use data gathered by multiple WATCH 4 ERS units to 1. better understand the cost–benefit balance of methane sensors, and 2. identify how decreasing instrumentation costs could increase deployment coverage and therefore inform large-scale methane monitoring strategies. Both calibration and response experiments indicate the INIR has little practical use for measuring methane concentrations less than 500 ppm. The MOx sensor is shown to have a logarithmic response to methane concentration change between background and 600 ppm but it is strongly suggested that passively sampling MOx sensors cannot respond fast enough to report concentrations that change in a sub-minute time frame. The NDIR sensor reported a linear change to methane concentration between background and 600 ppm, although there was a noticeable lag in reporting changing concentration, especially at higher values, and individual peaks could be observed throughout the experiment even when the plumes were released 5 s apart. The TDLAS sensor reported all changes in concentration but remains prohibitively expensive. Our findings suggest that each sensor technology could be optimized by either operational design or deployment location to quantify methane emissions. The WATCH4ERS units will be deployed in real-world environments to investigate the utility of each in the future.

47 OTHER INSTRUMENTATION↗

Out-of-Pile Testing and Instrumentation Transient Water Irradiation System

Current initiatives to increase the burnup of conventional nuclear fuels past the approximate 62 GWd/t limit have been spurred on by direct savings to refueling and waste storage. The technical justification for a new license limit requires extensive qualification through experimental testing. Unlike beginning-of-life fuels, high-burnup fuels are more susceptible to fuel fragmentation, relocation, and dispersal (FFRD), therefore more data is needed to characterize fuels under key accident scenarios. The Transient Reactor Test Facility (TREAT) located at the Idaho National Laboratory has developed a testing apparatus architecture to test fuels and claddings at prototypic conditions. The Transient Water Irradiation System (TWIST) is the latest iteration of a testing device capable of conducting loss of coolant accidents (LOCAs) in TREAT. The Out-of-Pile Testing and Instrumentation TWIST (OPTI-TWIST) is an electrically heated device that is analogous to TWIST. OPTI-TWIST allows for detailed instrumentation and thermal-hydraulic characterization. TWIST ultimately aims to conduct the most advanced in-situ diagnostics to evaluate FFRD in a prototypic LOCA. Moreover, it will explore the phenomenological bifurcation of a decay-energy heat up driven LOCA and a stored-energy heat up driven LOCA. The instrumentation suite includes conventional thermocouples and pressure transducers in addition to an electro impedance sensor, an acoustic emission sensor, an optical pressure sensor, and an optical pyrometer. Characterizing these instruments in OPTI-TWIST eliminates complications of irradiation effects while preserving extreme thermal-hydraulic conditions. Finally, benchmarking both devices to a thermal-hydraulic code like the Reactor Excursion and Leak Analysis Program (RELAP)5-3D provides a unique opportunity for iteration. Pre-test predictions and post-test interpretations inform the physical designs, operational procedures, test conditions, and instrumentation types and positions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Instrumentation & Data Acquisition System (D AS) Engineer

The primary job of an Instrumentation and Data Acquisition System (DAS) Engineer is to properly measure physical phenomenon of hardware using appropriate instrumentation and DAS equipment designed to record data during a specified test of the hardware. A DAS system includes a CPU or processor, a data storage device such as a hard drive, a data communication bus such as Universal Serial Bus, software to control the DAS system processes like calibrations, recording of data and processing of data. It also includes signal conditioning amplifiers, and certain sensors for specified measurements. My internship responsibilities have included testing and adjusting Pacific Instruments Model 9355 signal conditioning amplifiers, writing and performing checkout procedures, writing and performing calibration procedures while learning the basics of instrumentation.

Jackson, Markus Deon↗

Magnitude calibration of a fixed head star tracker using Astro-1 flight data

The Astro-1 UV astronomy mission was hampered by the failures of the automatic star acquisition procedure. The acquisition procedure depended on the Instrument Pointing Subsystem's Fixed Head Star Trackers (FHST) to acquire, track and identify guidestars of known visual magnitude. During the Astro-1 mission it was suspected that the star magnitudes measured by the FHST were much lower than predicted. A postflight investigation of the Astro-1 flight data confirmed and quantified this suspicion. Star magnitude calibration curves computed from the flight data depict the variance from the preflight calibration curves. These results are helping engineers to plan improvements to the acquisition procedure for the upcoming Astro-2 mission.

Rakoczy, John M.↗

Alignment of Optical Backscatter Measurements from the EXPORTS Northeast Pacific Field Deployment

Backscattering of light is commonly measured by ocean observing systems, including ships and autonomous platforms, and is used as a proxy for the concentration of water column constituents such as phytoplankton and particulate carbon. Multiple on-going projects involve large numbers of independent measurements of backscatter, as well as other biologically relevant parameters, to understand how biology is changing in time and space throughout the global ocean. Rarely are there sufficient measurements to test how well these instruments are inter-calibrated in real-world deployment conditions. This paper develops a procedure to align multiple independently calibrated backscatter instruments to each other using nearby profiling casts and applies this method to nine instruments deployed during a recent field campaign in the North Pacific during August–September of 2018. This process revealed several incorrect calibrations; post-alignment, all nine instruments aligned extremely well with each other. We also tested an alignment to a deep-water reference and found that this method is generally sufficient but has significant limitations; this procedure lacks the ability to correct instruments measuring only shallow profiles and can only account for additive offsets, not multiplicative changes. These findings highlight the utility of process studies involving several independent measurements of similar parameters in the same area.

North Pacific↗

Setting priorities for space research: An experiment in methodology

In 1989, the Space Studies Board created the Task Group on Priorities in Space Research to determine whether scientists should take a role in recommending priorities for long-term space research initiatives and, if so, to analyze the priority-setting problem in this context and develop a method by which such priorities could be established. After answering the first question in the affirmative in a previous report, the task group set out to accomplish the second task. The basic assumption in developing a priority-setting process is that a reasoned and structured approach for ordering competing initiatives will yield better results than other ways of proceeding. The task group proceeded from the principle that the central criterion for evaluating a research initiative must be its scientific merit -- the value of the initiative to the proposing discipline and to science generally. The group developed a two-stage methodology for priority setting and constructed a procedure and format to support the methodology. The first of two instruments developed was a standard format for structuring proposals for space research initiatives. The second instrument was a formal, semiquantitative appraisal procedure for evaluating competing proposals. This report makes available complete templates for the methodology, including the advocacy statement and evaluation forms, as well as an 11-step schema for a priority-setting process. From the beginning of its work, the task group was mindful that the issue of priority setting increasingly pervades all of federally supported science and that its work would have implications extending beyond space research. Thus, although the present report makes no recommendations for action by NASA or other government agencies, it provides the results of the task group's work for the use of others who may study priority-setting procedures or take up the challenge of implementing them in the future.

Source record↗

Cosmic Infrared Background Fluctuations in Deep Spitzer Infrared Array Camera Images: Data Processing and Analysis

This paper provides a detailed description of the data reduction and analysis procedures that have been employed in our previous studies of spatial fluctuation of the cosmic infrared background (CIB) using deep Spitzer Infrared Array Camera observations. The self-calibration we apply removes a strong instrumental signal from the fluctuations that would otherwise corrupt the results. The procedures and results for masking bright sources and modeling faint sources down to levels set by the instrumental noise are presented. Various tests are performed to demonstrate that the resulting power spectra of these fields are not dominated by instrumental or procedural effects. These tests indicate that the large-scale ([greater, similar]30') fluctuations that remain in the deepest fields are not directly related to the galaxies that are bright enough to be individually detected. We provide the parameterization of these power spectra in terms of separate instrument noise, shot noise, and power-law components. We discuss the relationship between fluctuations measured at different wavelengths and depths, and the relations between constraints on the mean intensity of the CIB and its fluctuation spectrum. Consistent with growing evidence that the [approx]1-5 [mu]m mean intensity of the CIB may not be as far above the integrated emission of resolved galaxies as has been reported in some analyses of DIRBE and IRTS observations, our measurements of spatial fluctuations of the CIB intensity indicate the mean emission from the objects producing the fluctuations is quite low ([greater, similar]1 nW m-2 sr-1 at 3-5 [mu]m), and thus consistent with current [gamma]-ray absorption constraints. The source of the fluctuations may be high-z Population III objects, or a more local component of very low luminosity objects with clustering properties that differ from the resolved galaxies. Finally, we discuss the prospects of the upcoming space-based surveys to directly measure the epochs inhabited by the populations producing these source-subtracted CIB fluctuations, and to isolate the individual fluxes of these populations.

Arendt, Richard↗

The Surveyor lunar landings.

Surveyor lunar landing procedures and results including instrumentation, lunar topography, selenology, chemical and physical properties, solar corona and earth laser output observations

Jaffe, L. D.↗

Remote Sensing of Earth Resources (1970-1973 Supplement): A Literature Survey with Indexes

This literature survey cites 4930 reports, articles and other documents that were announced between March 1970 and December 1973 in Scientific and Technical Aerospace Reports (STAR) or in International Aerospace Abstracts (IAA). This publication supplements Remote Sensing of Earth Resources (NASA-SP-7036) that cited documents announced between January 1962 and February 1970. Beginning in 1974, a quarterly publication, Earth Resources, A Continuing Bibliography (NASA-SP-7041) was initiated. The first issue, NASA-SP-7041(01), was published in June covering the document announced between January 1974 and March 1974. The coverage includes documents related to the identification and evaluation by means of sensors in spacecraft and aircraft of vegetation, minerals, and other natural resources, and the techniques and potentialities of surveying and keeping up-to-date inventories of such riches. It encompasses studies of such natural phenomena as earthquakes, volcanoes, ocean currents and magnetic fields; and such cultural phenomena as cities, transportation networks, and irrigation systems. Descriptions of the components and use of remote sensing and geophysical instrumentation, their subsystems, observational procedures, signature and analyses and interpretive techniques for gathering data are also included. Reports generated under NASA's Earth Resources Survey Program and announced during the period covered by this bibliography are included.

Source record↗