Search NASA⌕ Search

SEARCH · Search NASA

Results for “Instrumentation and Control Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Root Cause Correlation Analysis of Software Failures via Orthogonal Defect Classification and Natural Language Processing

Systems theoretic process analysis (STPA) is becoming an increasingly popular technique to assess how complex digital software systems can fail. Rather than defining failures by their observable failure events, which may be sparse especially for safety rated nuclear digital instrumentation and control systems (DI&C), failures are defined as postulated unsafe actions under specific contextual conditions. This permits a top-down analysis of system hazards and identifies whether imposed constraints and requirements can sufficiently address undesirable hazards. However, STPA is a qualitative approach at identifying inadequacies in the development process and cannot currently be used to quantify unsafe action likelihoods for probabilistic risk assessment. Therefore, in this work, we examine the root causes of software failure and explore whether a consistent correlation can be linked to specific unsafe action classes. We implement Lbl2Vec, an unsupervised document classification and retrieval algorithm, on a database of 4,096 software defect reports acquired from various open-source software systems. By analyzing sentence structure, embedded labels, and word vectors, we show that certain defect types positively correlate to specific unsafe action classes over others. The correlations developed can be used to estimate the failure probability of safety intended DI&C systems which provides a licensing basis for nuclear plant modernization efforts.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Non-Nuclear Test Facility Development to Support Verification and Validation Needs

This study focuses on developing a non-nuclear test facility to help meet the verification and validation (V&V) requirements of a water-cooled small modular reactor (SMR) system. The scaling analysis necessary for reactor system experimentation and assessment model V&V considers various reactor system accident scenarios such as main steam line break (MSLB), steam generator tube rupture (SGTR), and containment condensation and heat transfer. The goal is to identify key physics based phenomena of interest (POI), specific figures of merit (FOMs), and the state of knowledge (SOK) by employing phenomena identification and ranking table (PIRT) studies. Important physics phenomena such as heat transfer, fluid dynamics, structural integrity, and material selection must be addressed when scaling a thermal-hydraulics system. Alongside these considerations, modifications to the facility may be needed to align the scaled system with the available footprint (height and space) of the facility. These modifications may include infrastructure upgrades, changes to the piping layout, implementation of safety measures, and installation of new instrumentation and control systems. The test facility aims to provide a scaled-down version of prototypic facilities for comprehensive V&V activities by overcoming these challenges and making the necessary modifications. This approach minimizes scaling distortion, simulates prototypic plant conditions, and accurately models accident event progressions. Thus, the facility will be capable of adequately modeling a scaled SMR system to support the design, development and licensing needs.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Design of Timer Circuit for Dynamic Data System

The Branch That I work in is in the Aero Electronic Test Branch, which is part of the Research and Testing Division. The Aero Electronic Test Branch deals with electronic control and instrumentation systems. This branch supports the research and test study of wind tunnels such as the l0x10,9x15, and 8x6. Wind tunnels are used in research to test certain parts of a jet, plane, shuttle or any other flying object in certain test conditions. My assignment is to design a programmable trigger circuit on a 19 standard rack mount that will allow the circuit to latch and hold for a predefined amount of time entered by the user when receiving a signal. It should then re-arm itself within 0.25 seconds after the time is finished. The time should be able to be seen on a display showing the time entered. The time range has to be from 0-600 seconds in 0.01 second increments (600.00). From the information given, counters will be needed to design and build this circuit. A counter, in it s simplest form, is a group of flip flops that can temporarily store bits of information put into the circuit. They can be constructed in many different ways, such as in 4 flip flops (4-bit counter) or 8 flip flops and even higher. Counters are usually cascaded with other counters to reach higher bits, such as 16 or 24 bit counters. The application in which I will use the counters will be to count down from any programmable number that I input either by a keyboard or a thumbwheel. Also, I will use counters that will be used specifically as a frequency divider to divide the pulses that enter the circuit through an input signal from a crystal clock. The pulses will need to be divided so that it will function as a 100Hz clock putting out 100 pulses per second. A switch will be used to load my inputs in and more than likely a button also so that I can stop and hold the count at any point of time. I will use 5 BCD up/down programmable counters, and a certain amount (depending on what kind of "divide by N" counter I use) of frequency dividing counters for the assignment. After the design is carefully made, a task order will be written and then given to the manufacturer to create a rack mount circuit board that will match my specifications given. The applications in which this design will be used for is in the use of the six-component balance signal conditioner for measurement and electronic system control. It can be used as a timer system for the balance signal conditioner in which it does numerous tests for the Wind tunnel research, in which a preset time can be set for how long it performs its tests. Specifically, my design should be applied to the balance signal conditioner used for the 8x6 wind tunnel research. Hopefully this design should aid in more efficient research for the 8x6 wind tunnel.

Young, Nathaniel, III↗

Aerospace Vehicle Design, Spacecraft Section. Volume 3

Research results are presented for the following groups: Project Mars Airplane Vehicle and Reconnaissance Instrument Carrier (MAVRIC), ACME, ARES, Project ACRONYM, Mars Aircraft Recepticle with Technical Instruments, Aerobraking, and Navigation (MARTIAN), and NOMADS. Each project is described by the following areas of focus: mission planning and costs; aerobraking systems; structures and thermal control systems; attitude and articulation control systems; comman and data control systems; science instrumentation; and power and propulsion systems.

Source record↗

System Upgrades at the Advanced Test Reactor Help Ensure that Nuclear Energy Research Continues at the Idaho National Laboratory

Fully operational in 1967, the Advanced Test Reactor (ATR) is a first-of-its-kind materials test reactor. Located on the Idaho National Laboratory’s desert site, this reactor remains at the forefront of nuclear science, producing extremely high neutron irradiation in a relatively short time span. The Advanced Test Reactor is also the only U.S. reactor that can replicate multiple reactor environments concurrently. The Idaho National Laboratory and the Department of Energy recently invested over 13 million dollars to replace three of ATR’s instrumentation and control systems. The new systems offer the latest software and technology advancements, ensuring the availability of the reactor for future energy research. Engineers and project managers successfully completed the four year project in March while the ATR was in a scheduled maintenance outage. “These new systems represent state-of-the-art monitoring and annunciation capabilities,” said Don Feldman, ATR Station Manager. “They are comparable to systems currently used for advanced reactor designs planned for construction in the U.S. and in operation in some foreign countries.”

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Importance Ranking of Software Dependability Attributes in the Nuclear Industry

With the current transition from analog to digital instrumentation and control systems in nuclear power plants, the number and variety of software-based systems has significantly increased. Due to the sophisticated nature and the increasing complexity of software, a significant challenge faced by the nuclear industry is the trust one can place in software-based systems once they have been developed. The trust placed in software is typically termed software dependability, a qualifier which encompasses different attributes such as software reliability, safety, security, availability and maintainability. It is recognized that these attributes relate to each other in different ways under various scenarios. The detailed dependencies between software dependability attributes can be found in a previous study. With limited time and budget resources, which dependability attribute should be given the highest priority when certifying software-based systems in the nuclear industry is a fundamental question that needs to be answered. This paper addresses this problem using stakeholders' opinion elicitation. A comprehensive questionnaire was designed to elicit the goals that should be fulfilled by the nuclear industry and to collect the relative importance of the various dependability attributes for each goal. We then used the Analytical Hierarchy Process (AHP) to analyze the data and obtained the relative importance ranking of software dependability attributes in the context of a reactor protection system. The results will provide guidance to resource allocation for the certification of software dependability in the nuclear industry. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Embedded EPICS server for PowerPMAC motion controllers

An embedded server layer of Experimental Physics and Industrial Control System (EPICS) for PowerPMAC motion controllers has been developed and deployed at two undulator beamlines of the National Institute of General Medical Sciences and the National Cancer Institute (GM/CA) Structural Biology Facility at the Advanced Photon Source (APS). This compact, open source solution makes the power and versatility of PowerPMAC motion controls directly accessible to distributed EPICS clients. At GM/CA the system controls about 200 servo and stepper motors — both encoded and unencoded — and multiple digital and analog I/O accessories. The server stack comprises two sublayers: a lower-level driver and database that communicates directly with PowerPMAC, and a facility-specific soft sublayer built on top. The paper describes installing EPICS on PowerPMAC, the implementation of both layers and client examples, including on-the-fly scanning.

EPICS↗

PROGRESS IN DESIGN OF THE INSTRUMENTATION AND CONTROL OF THE TOKAMAK COOLING WATER SYSTEM

This paper discusses progress in the design of the control, interlock and safety systems of the Tokamak Cooling Water System (TCWS) for the ITER fusion reactor. The TCWS instrumentation and control (I&C) is one of approximately 200 separate plant I&C systems (e.g., vacuum system I&C, magnets system I&C) that interface to a common central I&C system through standardized networks. Several aspects of the I&C are similar to the I&C of fission-based power plants. However, some of the unique features of the ITER fusion reactor and the TCWS (e.g., high quasi-static magnetic field, need for baking and drying as well as cooling operations), also demand some unique safety and qualification considerations. The paper compares the design strategy/guidelines of the TCWS I&C and the I&C of conventional nuclear power plants. Issues such as safety classifications, independence between control and safety systems, sensor sharing, redundancy, voting schemes, and qualification methodologies are discussed. It is concluded that independence and separation requirements are similar in both designs. However, the voting schemes for safety systems in nuclear power plants typically use 2oo4 (i.e., 4 divisions of safety I&C, any 2 of which is sufficient to trigger a safety action), while 2oo3 voting logic - within each of 2 independent trains - is used in the TCWS I&C. It is also noted that 2oo3 voting is also acceptable in nuclear power plants if adequate risk assessment and reliability is demonstrated. Finally, while qualification requirements provide similar guidance [e.g., both IEC 60780 (invoked in ITER-space), and IEEE 323 (invoked in fission power plant space) provide similar guidance], an important qualification consideration is the susceptibility of I&C to the magnetic fields of ITER. Also, the radiation environments are different. In the case of magnetic fields the paper discusses some options that are being considered.

Korsah, Kofi↗

SPC-2734 Chromalox Oil Heater System Procurement Specification

This specification will supply the necessary technical information to the vendor to allow them to provide the system we need for the Thermal Energy Delivery System (TEDS) construction. TEDS is being constructed within the dynamic energy transport and integration laboratory (DETAIL) facility to test heat transfer components, distribution systems, instruments, and controls that can be monitored and controlled for hybrid generation of electrical power and/or non-electrical products. TEDS is designed to operate as a part of an integrated system or independently to demonstrate component operations, to develop and validate thermal energy transport models and control systems, and to study thermal energy inertia and storage. Within the integrated system, TEDS will be connected to the INL Real Time Digital Simulator (RTDS) test platform to develop and demonstrate monitoring and control systems and to investigate real-time, hardware-in-the-loop response characteristics relative to grid operations. As the basis of the TEDS, Chromalox (the vendor) has been chosen to design and supply a heater, pump, storage tanks, and pressure vessel due to their experience with industrial-scale heat transfer oil systems.

25 ENERGY STORAGE↗

Testing Long-Term Exposure To Vacuum

Facility for studying long-term effects of vacuum on materials described in report. Vacuum storage system maintains specimens at constant temperature and high vacuum. Enables specimens to be removed easily and safely for analysis. Nitrogen storage system maintains specimens at 77 degree F in pure, dry nitrogen gas under gauge pressure of 2 to 4 psi. Enables comparison of control specimens with specimens exposed to vacuum. Instrumentation-and-control system measures and records operating parameters and generates control signals and alarm indications as necessary.

Clark, D. L.↗

Improved Nuclear Reactor and Shield Mass Model for Space Applications

New technologies are being developed to explore the distant reaches of the solar system. Beyond Mars, solar energy is inadequate to power advanced scientific instruments. One technology that can meet the energy requirements is the space nuclear reactor. The nuclear reactor is used as a heat source for which a heat-to-electricity conversion system is needed. Examples of such conversion systems are the Brayton, Rankine, and Stirling cycles. Since launch cost is proportional to the amount of mass to lift, mass is always a concern in designing spacecraft. Estimations of system masses are an important part in determining the feasibility of a design. I worked under Michael Barrett in the Thermal Energy Conversion Branch of the Power & Electric Propulsion Division. An in-house Closed Cycle Engine Program (CCEP) is used for the design and performance analysis of closed-Brayton-cycle energy conversion systems for space applications. This program also calculates the system mass including the heat source. CCEP uses the subroutine RSMASS, which has been updated to RSMASS-D, to estimate the mass of the reactor. RSMASS was developed in 1986 at Sandia National Laboratories to quickly estimate the mass of multi-megawatt nuclear reactors for space applications. In response to an emphasis for lower power reactors, RSMASS-D was developed in 1997 and is based off of the SP-100 liquid metal cooled reactor. The subroutine calculates the mass of reactor components such as the safety systems, instrumentation and control, radiation shield, structure, reflector, and core. The major improvements in RSMASS-D are that it uses higher fidelity calculations, is easier to use, and automatically optimizes the systems mass. RSMASS-D is accurate within 15% of actual data while RSMASS is only accurate within 50%. My goal this summer was to learn FORTRAN 77 programming language and update the CCEP program with the RSMASS-D model.

Robb, Kevin↗

Detectors and Instrumentation [Slides]

D&I targets diagnostic maturation and development for subcritical and hydrodynamic experiments 2 to 5 years into the future. Key technology areas include imaging, detectors, instruments and control systems. Most of the work scope is funded from Stockpile Stewardship’s Hydrodynamic and Subcritical Experiment Execution Support (HSEES) portfolio.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Friction Stir Welding of Tapered Thickness Welds Using an Adjustable Pin Tool

Friction stir welding (FSW) can be used for joining weld lands that vary in thickness along the length of the weld. An adjustable pin tool mechanism can be used to accomplish this in a single-pass, full-penetration weld by providing for precise changes in the pin length relative to the shoulder face during the weld process. The difficulty with this approach is in accurately adjusting the pin length to provide a consistent penetration ligament throughout the weld. The weld technique, control system, and instrumentation must account for mechanical and thermal compliances of the tooling system to conduct tapered welds successfully. In this study, a combination of static and in-situ measurements, as well as active control, is used to locate the pin accurately and maintain the desired penetration ligament. Frictional forces at the pin/shoulder interface were a source of error that affected accurate pin position. A traditional FSW pin tool design that requires a lead angle was used to join butt weld configurations that included both constant thickness and tapered sections. The pitch axis of the tooling was fixed throughout the weld; therefore, the effective lead angle in the tapered sections was restricted to within the tolerances allowed by the pin tool design. The sensitivity of the FSW process to factors such as thickness offset, joint gap, centerline offset, and taper transition offset were also studied. The joint gap and the thickness offset demonstrated the most adverse affects on the weld quality. Two separate tooling configurations were used to conduct tapered thickness welds successfully. The weld configurations included sections in which the thickness decreased along the weld, as well as sections in which the thickness increased along the weld. The data presented here include weld metallography, strength data, and process load data.

Adams, Glynn↗

Progress on the MARVEL Cybersecurity by Design Model-Based Systems Engineering Project

Formal model-based systems engineering (MBSE) combines a model, systems thinking, and systems engineering to visually depict the boundaries, context, and behavior of interconnected systems, facilitating effective design, development, and utilization of engineered systems throughout the systems engineering lifecycle. Although nuclear reactor vendors employ these tools to integrate functionality, performance, and safety, they are not yet addressing digital risk concerns introduced by use of operational technology, such as digital instrumentation and control systems. To accomplish this objective, the Microreactor Applications Research Validation and EvaLuation (MARVEL) microreactor was used as an MBSE case study. This real-world application provides a first-of-a-kind opportunity to demonstrate the benefits of integrating digital risk and cybersecurity into the MBSE design process of a nuclear reactor. This paper provides an update of the ongoing MARVEL Cyber MBSE project as it specifically relates to the integration of digital risk management and cybersecurity by design.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

RCCS Testing with the Water-based NSTF: Year-1 Single-Phase Results

Under support from the Department of Energy (DOE) and the Office of Advanced Reactor Technologies (ART), a large scale test facility has been constructed to generate validation data for passive decay heat removal systems of advanced reactors. Located at Argonne National Laboratory, the Natural convection Shutdown heat removal Test Facility (NSTF) reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS). This report serves as a summary of the single-phase testing results obtained during the programs first year of matrix testing. An introduction to the high-level program objectives is first presented, followed by a brief summary of facility design, instrumentation, and control systems. Details of the NQA-1 driven test method are included, which govern the programs quality assurance requirements and provide a background for the testing strategy and procedures. Checkout activities, including verification of gross system mass and energy balances, heat loss quantification, and isothermal facility characterization, were performed early in the first year and results presented in this report. These tests have identified relevant facility characteristics such as K-factors, frictional pressure losses, parasitic heat loss rates, and transient heating response. Results are then presented from four accepted matrix tests where the facility established a steady-state, single-phase mode of flow operation. All matrix tests were performed with an identical top-level procedure: first initiating a heater power ramp to target levels, and then holding power levels constant until the facilities structural members and network piping reached thermal equilibrium. Upon obtaining stable thermal and hydraulic conditions, active cooling was initiated off of the bulk storage tank to maintain constant riser inlet temperatures of 30°C. This steady-state period was then held for a minimum required duration, at which point the heaters were ramped down and test concluded. The two baseline tests completed reflect conditions prototypic to the full scale plant at both normal operation, and design basis Depressurized Loss of Forced Cooling (DLOFC) conditions. These parameters are defined by full RCCS decay heat loads of 1.4 MWt and 2.1 MWt, which translate to NSTF scale thermal power levels of 34.4 kWt and 51.6 kWt, respectively. Two additional tests were also conducted, which repeated baseline cases but included modification by single parameter variations in decay heat load, or heater power, at 700 kWt, and 2.8 MWt. Finally, a scoping test was performed to demonstrate the facilities ability to operate in a two-phase mode of operation. The facility successfully operated for a 3-hour period at this mode, reaching peak inventory temperatures of 105°C and condensing approximately 50 gallons of boil-off inventory. The testing parameters for this demonstration were based off the design basis DLOFC condition, and will be the reference for new baseline cases as the program moves forward with two-phase matrix testing.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Survey of Cyber Risk Analysis Techniques for Use in the Nuclear Industry

Using traditional probabilistic risk analysis methods for severe accident safety risk management on non-digital systems, structures, and components at nuclear power plants is well-established. In contrast, cyber risk analysis of digital assets is still an immature field with unproven techniques due, in part, to the continuously changing threat environment and the challenge of digital assets failing in unexpected ways. As the nuclear fleet continues to adopt digital instrumentation and control systems, it is increasingly important to have effective and efficient cyber risk analysis techniques to support risk management decisions, such as risk elimination by system redesign or risk mitigation by implementation of prioritized security controls. To understand the state of the art in cyber risk analysis for future research, we surveyed 36 publications across ten application domains. We describe our survey methodology and rate each technique based upon scope, adoptability, and repeatability. In this work, we examine the unique constraints of the nuclear industry and outline the strengths and weaknesses of using the cyber risk analysis techniques in the industry, highlighting gaps with current techniques. We also discuss challenges and potential research directions for advancing the science for both existing and new advanced reactors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗