Search NASA⌕ Search

SEARCH · Search NASA

Results for “Integrating Cybersecurity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Real-World Cyber Security Demonstration for Networked Electric Drives

In this article, we present the design and implementation of a cyber-physical security testbed for networked electric drive systems, aimed at conducting real-world security demonstrations. To our knowledge, this is one of the first security testbeds for networked electric drives, seamlessly integrating the domains of power electronics and computer science, and cybersecurity. By doing so, the testbed offers a comprehensive platform to explore and understand the intricate and often complex interactions between cyber and physical systems. The core of our testbed consists of four electric machine drives, meticulously configured to emulate small-scale but realistic information technology (IT) and operational technology (OT) networks. This setup both provides a controlled environment for simulating a wide array of cyber-attacks, and mirrors potential real-world attack scenarios with a high degree of fidelity. The testbed serves as an invaluable resource for the study of cyber-physical security, offering a practical and dynamic platform for testing and validating cybersecurity measures in the context of networked electric drive systems. As a concrete example of the testbed's capabilities, we have developed and implemented a Python-based script designed to execute step-stone attacks over a wireless local area network (WLAN). This script leverages a sequence of target IP addresses, simulating a real-world attack vector that could be exploited by adversaries. To counteract such threats, we demonstrate the efficacy of our developed cyber-attack detection algorithms, which are integral to our testbed's security framework. Furthermore, the testbed incorporates a real-time visualization system using InfluxDB and Grafana, providing a dynamic and interactive representation of networked electric drives and their associated security monitoring mechanisms. This visualization component not only enhances the testbed's usability but also offers insightful, real-time data for researchers and practitioners, thereby facilitating a deeper understanding of cyber-physical security dynamics in networked electric drive systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Robotic automation of maintenance work in nuclear power plants a cross-sector survey and roadmap

Nuclear power plants face increasing cost pressures, workforce constraints (aging workforce and skilled labor shortages), and safety requirements that are accelerating interest in robotic systems for inspection and maintenance. We conducted semi-structured interviews with personnel from seven U.S. nuclear utilities and compared deployment models, operational use cases, and integration practices with those reported by participants in the oil, gas, and petrochemical sector. In nuclear plants, robotic use remains concentrated in inspection—particularly indoor unmanned aerial vehicles and submersible remotely operated vehicles—with limited application to physical maintenance tasks. Reported near-term value includes reduced radiological and industrial risk, reduced outage labor, and improved data for planning and condition assessment. Key barriers include integration and data-interoperability constraints, operator qualification requirements, cybersecurity review burden, and difficulty demonstrating reliability in plant-representative environments. Cross-sector benchmarking highlights organizational and deployment practices that may help nuclear plants scale from pilots to routine use. We propose a deployment-oriented roadmap emphasizing modular payload strategies, representative qualification pathways and testing environments, and improved data governance to support safe and economically justified expansion of robotics in operating nuclear power plants.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Adaptive Cybersecurity for Distributed Energy Resources (AdCyDER): Online Reinforcement Learning with Stackelberg-Optimized Defenses — Pipeline Architecture, Evaluation Methodology, and Findings from a Synthetic-Data Evaluation

This report documents the design and evaluation of an integrated online-learning pipeline developed within the AdCyDER project for Distributed Energy Resource (DER) cybersecurity. The pipeline couples a Reinforcement Learning (RL) attack classifier — which produces an attack-type probability distribution — with a Stackelberg game-theoretic (GT) defense selector that consumes those distributions alongside SME-encoded priors over (defense, attack) effectiveness pairings and perdefense costs to choose grid-health-preserving defenses. The objective is not attack classification per se but production of distributions that drive effective defense selection through the Stackelberg layer, learned from delayed grid-health feedback rather than labeled attack data. AdCyDER as a whole is broader than the work presented here; this report covers the specific RL/GT loop integration and its evaluation. We present the integrated pipeline (SCADA telemetry with Fronius inverter physics, Suricata IDS, time-windowed aggregation, per-facility LSTM classifier, Stackelberg optimizer, OpenC2 actuators), an experimental campaign of 28 eight-hour iterations across three baseline modes, and a pipeline-ordered diagnostic protocol. The protocol identifies two distinct failure modes within the loop: paired supervised ceilings on the same features establish that the deployed online RL classifier (macro F1 ≈ 0.07) sits at least 4.7× below a same-architecture supervised LSTM (≈ 0.34) and 10–11× below a linear feature-signal ceiling (≈ 0.70–0.79 depending on per-facility isolation), localizing the dominant failure to the training procedure; and the reward signal driving online updates carries weak directional coupling with classifier correctness in the methodology-expected direction (multi-lens convergent: top-decile P(true) records produce more frequent state changes and slightly larger improvements, top-vs-bot Cohen’s 𝑑 ≈ −0.19), but at effect magnitudes too small to drive gradient-based learning at the campaign sample size. The original learning hypothesis is not supported by the data. The primary contributions are the diagnostic methodology — proposed as a transferable falsification protocol for online RL/GT defense pipelines learning from delayed environmental reward — and the open, reproducible experimental infrastructure. We outline reward reformulation as the highest-priority aspirational next step given the underpowered-but-aligned Q6 reading, with hardware-in-the-loop evaluation as the broadest scope-expansion option.

Blakely, Benjamin [Argonne National Laboratory (AN↗

A Photovoltaic MPPT Charge Controller Real-Time Testbed for Cybersecurity Applications

The increasing deployment of distributed energy resources (DER) over the last decade is a great ally to combat climate change and strengthen the grid during increasingly common extreme weather events. However, DER systems, combined with the ongoing transition to a digital power grid, also pose substantial cybersecurity threats. One of the most common communication protocols used in DER integration is the Distributed Network Protocol 3 (DNP3), which is known to have many security vulnerabilities. Thus, it is essential to investigate cyberattack behaviors and mitigation on power systems using DNP3. In this paper, we designed and implemented a cybersecurity testbed for a simulated photovoltaic (PV) maximum power point tracking (MPPT) charge controller. Our testbed uses an MPPT charge controller simulated on a Typhoon HIL602+ real-time simulator with a real DNP3 communication connection over TCP/IP, allowing for safe and efficient monitoring and manipulation of data traffic between the simulated hardware and supervisory control and data acquisition (SCADA) systems.

14 SOLAR ENERGY↗

Tale of Two Domains: Cyber - Physical

As devices and systems continue to modernize and adopt integrated circuits, the use of cyber technology to deploy an application is the expectation. This deployment through cyber assets brings new cyber risk and cybersecurity is the practice of managing this risk. Cyber-risk is constantly changing due to the speed of technology advancement and the changing quality of the adversary. Cyber-Informed Engineering (CIE) mitigates cyber-risk through engineering controls where as the traditional practice of cybersecurity mitigates cyber-risk through cybersecurity controls. By clearly defining the cyber-physical boundary, engineering controls and cybersecurity controls can clearly demonstrate their complementary nature to provide layered defenses and successfully mitigate cyber-risk through independent controls. In this paper, a layered model of device decomposition of the the cyber-physical boundary is presented to provide clarity where engineering controls are used to reduce cyber-risk within the physics, functional materials, electronic, or integrated circuit layers and where cybersecurity controls are used to reduce cyber-risk within the machine code and application layers. By implementing both traditional cybersecurity controls and engineering controls, a more holistic approach to cybersecurity is achieved in protecting modern devices and systems, as well as a clear awareness in identifying, documenting, and authorizing the system’s cybersecurity protection scheme is achieved.

42 - ENGINEERING↗

Caribbean Energy Sector Cybersecurity Forum: Modernizing and Securing the Grid

This presentation on Modernizing and Securing the Grid brought together regional and NREL cybersecurity expertise for USAID's Caribbean Energy Sector Cybersecurity Forum. The presentation's overall purpose was to provide a deep dive into the changes underway in the electric grid, including the greater integration of renewables and distributed energy resources. The presentation also reviewed best practices for building cybersecurity into modern energy systems, including in the areas of vendor assessment and supply chain cybersecurity.

Caribbean↗

ARIES Annual Report FY25

Advanced Research on Integrated Energy Systems (ARIES) at the National Laboratory of the Rockies (NLR) is the U.S. Department of Energy's (DOE's) test bed for energy system demonstration and de-risking. ARIES comprises the largest collection of physical and digital assets in the DOE laboratory complex, supporting flexible configuration across a broad range of energy scenarios. In Fiscal Year 2025, ARIES provided a platform for system-level research to anticipate and address future energy needs in energy security, system reliability, and technology deployment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cybersecurity Standards for Distributed Energy Resources: Gaps and Harmonization Strategy

This report examines cybersecurity standards for Distributed Energy Resources (DERs) in light of their rapid growth and increasing integration into energy systems. It identifies critical gaps in existing frameworks, including inadequate coverage of DER-specific challenges, complexities in implementing comprehensive standards, integration issues with legacy systems, adoption hurdles for newer standards, and a lack of harmonization across regulatory landscapes. The analysis highlights vulnerabilities such as data integrity risks, unauthorized device control, and denial-of-service attacks across various DER technologies like solar PV, wind turbines, energy storage systems, and hydrogen fuel cells. The report proposes a harmonization strategy to address these deficiencies by developing unified cybersecurity requirements, certification programs, and training resources while fostering collaboration among stakeholders such as government agencies, industry groups, DER operators, manufacturers, and research institutions. A phased roadmap is outlined to refine and implement these measures through pilot testing and widespread adoption. Ultimately, the report underscores the urgent need for coordinated efforts to enhance DER cybersecurity and ensure the reliable operation of future energy systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Application of HFE to the design and V and V of a computerized procedure system: benefits and challenges - 234

The application of Human Factors Engineering (HFE) practices to the Human Machine Interface design and subsequent Verification and Validation (V and V) is a widely applied practice when talking about the design of complete control rooms or important control room modernizations, but not so often applied to the design of computerized operator support systems. In order to overcome the challenges faced on designing a Computerized Operation Support System (COSS) that meets the process efficiency requirements and integrates seemingly with hybrid plant operation concept, the involvement of a HFE team early in the COSS design and implementation process along with operation, Instrumentation and Control (I and C) and cybersecurity experts will guarantee the project success. This paper documents the HFE process applied during the design and evaluation of a Computerized Procedure System (CPS) and how final product was shaped to ensure that the transition from paper to computerized procedures will help in meeting Delivering the Nuclear Promise (DNP) goals, improving plant efficiency. The HFE program included the following activities: 1. A review of existing operating experience 2. An analysis of functions and tasks associated to the use and maintenance of CPS 3. A design verification of the system to meet guidelines prescribed in the NUREG-0700 (Rev.2), requirements of the ISG-05 and cybersecurity criteria (NEI 08-09, IEC-62646, EPRI 1015313, these among others). 4. An integrated system validation in a full scope simulator The application of HFE practices in the design and implementation of COSS helps not only to ensure that efficiency and safety improvement requirements are met, but also to evaluate the potential return of the investment, that such tools should bring. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Cybersecurity for distributed energy resources and smart inverters

The increased penetration of distributed energy resources (DER) will significantly increase the number of devices that are owned and controlled by consumers and third parties. These devices have a significant dependency on digital communication and control, which presents a growing risk from cyber attacks. This paper proposes a holistic attack-resilient framework to protect the the integrated DER and the critical power grid infrastructure from malicious cyber attacks, helping ensure the secure integration of DER without harming the grid reliability and stability. Specifically, we discuss the architecture of the cyber-physical power system with a high penetration of DER and analyze the unique cybersecurity challenges introduced by DER integration. Next, we summarize important attack scenarios against DER, propose a systematic DER resilience analysis methodology, and develop effective and quantifiable resilience metrics and design principles. Lastly, we introduce attack prevention, detection, and response measures specifically designed for DER integration across cyber, physical device, and utility layers of the future smart grid.

97 MATHEMATICS AND COMPUTING↗

A full-scope, high-fidelity simulator-based hardware-in-the-loop testbed for comprehensive nuclear power plant cybersecurity research

Nuclear power plant (NPP) cybersecurity research often relies on hardware-in-the-loop (HIL) testbeds that integrate real hardware components into simulated environments. These testbeds allow researchers to identify vulnerabilities, evaluate attack impacts, and test security measures in a controlled setting. Furthermore, previous HIL testbeds lacked fidelity to accurately represent real nuclear systems, limiting the scope of cybersecurity analysis. This study presents the creation of a HIL testbed, devised upon a full-scope, high-fidelity NPP simulator, to facilitate realistic and comprehensive cybersecurity research. To demonstrate its capabilities, the control logic for the steam generator water level was migrated from the simulator to an external programmable logic controller. As a practical application of the developed testbed, supply chain attack scenarios were simulated by injecting malicious code into the controller logic, and the effects of manipulating sensor inputs and control commands were observed. While this HIL testbed provides more detailed simulations, enhanced realism, and wider applicability compared to other options utilizing a less complex simulator, it is also more intricate and costly. For this reason, we include a detailed comparison with some alternative architectures to aid fellow researchers and practitioners in the selection of a suitable HIL architecture based on specific research objectives.

47 OTHER INSTRUMENTATION↗

Bayesian Attack Model (BAM) User Story

This document presents a user story for the Bayesian Attack Model (BAM) tool designed to aggregate and analyze cyber-attack observables for operational technology (OT) systems. BAM aims to empower cybersecurity analysts by providing a streamlined interface for collecting observable data from various sources, enabling real-time analysis of potential adversary activity. By enhancing the response capabilities of security teams, BAM facilitates risk-informed decision-making and improves organizational security posture. This user story outlines the key functionalities, user interactions, and requirements necessary to successfully integrate BAM with other security information and event management (SIEM) technology and cybersecurity operations centers (CSOCs).

97 MATHEMATICS AND COMPUTING↗

Security Evaluation of Smart Cards and Secure Tokens: Benefits and Drawbacks for Reducing Supply Chain Risks of Nuclear Power Plants

The supply chain attack pathway is being increasingly used by adversaries to bypass security controls and gain unauthorized access to sensitive networks and equipment (e.g., Critical Digital Assets). Cyber-attacks targeting supply chain generally aim to compromise the environments, products, or services of vendors and suppliers to inject, add, or substitute authentic software and hardware with malicious elements. These malicious elements are deemed to be authentic as they arise from the vendor or supplier (i.e., the supply chain). This research aims to leverage findings and assumptions made from the previous report to determine the security benefits and drawbacks of a smart card- based hardware root of trust. Smart cards can provide devices inside Nuclear Power Plants (NPP) with a secure environment to store keys in and perform sensitive operations such as digital signature generation. These abilities can be leveraged to increase supply chain cybersecurity by autonomously providing NPP Licensees with reports on device integrity, authenticity and measurements of executable and non-executable data.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

A Real-Time Testbed for Smart Inverter Cyber Security Studies

Distributed energy resources (DER) have become a popular solution to modern-day issues surrounding the efficiency and reliability of power generation, as well as climate change concerns. Energy centers are shifting towards incorporating smart inverters with embedded functionalities such as high voltage ride through (HVRT), low voltage ride through (LVRT), active and reactive power compensation. However, the integration of smart inverters leave DER systems highly vulnerable to cybersecurity threats. The distributed network protocol 3 (DNP3) is a common method of communication between grid-tied hardware. Despite its popularity, the level of security leaves all hardware connected to the grid at risk of severe cyber-attacks. Thus, it is important to study any potential cybersecurity threats towards grid-tied smart inverters to mitigate cybersecurity vulnerabilities and refine existing cyber-security protections. This report describes the proposed testbed design to study cybersecurity threats to smart inverters. The testbed utilizes a real-time simulation case in RSCAD that includes a grid-tied wind turbine (WT) topology featuring two back-to-back two-level voltage source converters (BTB,2L-VSCs) and a permanent magnet synchronous machine (PMSM). The simulated case runs within the NovaCor real time digital simulator (RTDS). This report focuses on the design and implementation of a single module of the GTNETx2 card as a distributed network protocol and the configuration of an IEEE 1518 DNP database file that includes input and output variables mapped to different connection points in the grid that transmit and receive discrete, analog, and binary signals on command. This allows realistic emulation of the communication between the smart inverter and the grid for cybersecurity studies.

97 MATHEMATICS AND COMPUTING↗

Technical Learning and Integration of Interns in Advanced Protection Lab Space: Enhancements to Testbed and Experiments to Improve Workflows for Producing Datasets

This report presents a successful technical learning integration of student interns in the Advanced Protection Laboratory space, located in the Grid Research Integration and Deployment Center (GRID-C) at the Department of Energy’s (DOE’s) Oak Ridge National Laboratory (ORNL). The Advanced Protection Laboratory was created for the primary goal of supporting DOE’s research projects and technical staff at ORNL. As a secondary goal, the space was used for collaborating with ORNL’s intern programs, providing support to the lab’s mentors and student interns. In 2024, three student interns spent a summer in the Advanced Protection lab space and were involved in the DarkNet Distributed Ledger Technology (DLT) project. The students had a great opportunity to gain hands-on experience with communication and protective relay equipment focused on information technology, data analytics, and cybersecurity. Experiences in the lab space with real equipment and software integration offer education and professional development for students, which is especially important because of a need in the energy industry to recruit highly skilled power and communication engineers.

42 ENGINEERING↗

Module-OT: A Turnkey Solution for Securing Energy Systems

The Modular Security Apparatus for Managing Distributed Cryptography for Command-and-Control Messages on Operational Technology Networks (Module-OT) is a flexible and lightweight solution for grid-edge devices focusing on end-to-end security. It is a bump- in- the-wire solution acting as a secure conduit for data between devices or systems across a network. It improves the cybersecurity posture of DER systems by providing authentication, authorization, and data integrity to secure DER communications. Additionally, it performs key management, provides data security through whitelisting Internet Protocol addresses and ports, blocks unauthorized connections, controls user access, and allows serial or Ethernet connections for added flexibility. The core software is portable to various Linux-based operating systems and is developed to be customized by the developer and researcher communities. Module-OT has been validated in the lab, has been demonstrated at a 500-KW PV-plus-storage site, and has been proven ready to secure operational technology devices. Its core functionality meets current standards, including validation procedures of the NIST Cryptographic Algorithm Validation Program (CAVP) and the Federal Information Processing Standard (FIPS 140-2). Because of its capability to provide an accessible and affordable option for stepping up security across modern energy systems, Module-OT can serve as an effective technological option to standardize cybersecurity moving forward.

cryptography↗

Universal Utility Data Exchange (UUDEX) – Security and Administration: Cybersecurity of Energy Delivery Systems (CEDS) Research and Development

A critical component of the Universal Utility Data Exchange (UUDEX) approach is the integrated security contained within its processing. This document describes how that security is designed and expected to be implemented by UUDEX Implementations (U-Implementations), including the UUDEX Server (U-Server) and UUDEX Clients (U-Clients). The UUDEX security hierarchy consists of three levels: 1. The UUDEX Instance (U-Instance) itself, which sits at the top of the hierarchy and contains the U-Server, the UUDEX Identity Authority (U-Identity Authority), and the UUDEX Administrator (U-Administrator) functions; 2. A group of one or more UUDEX Participants (U-Participants) that present “organizations” that participate in the U-Instance and contains the UUDEX Administrator Participant (U-U-Administrator Participant) function; 3. A group of one or more UUDEX Endpoints (U-Endpoints) that represent the individual UUDEX Publish Clients (U-Publish Client) responsible for supplying data to the U-Instance that is consumed by UUDEX Subscriber Clients (U-Subscriber Clients). U-Endpoints can be either autonomous devices that publish and subscribe data such as data exchange servers found in supervisory control and data acquisition and energy management systems, or they can be tied to users of applications that, for example, submit DOE OE-417 disturbance reports. U-Participants and U-Endpoints can be organized into UUDEX Groups (U-Groups). Any number of U-Participants or U-Endpoints can be members of a U-Group. A given U-Participant or U-Endpoint can be a member of multiple U-Groups, but a U-Group cannot contain other U-Groups. For example, a U-Group could be created to contain all U-Participant Transmission Operators within the purview of a Reliability Coordinator, and another U-Group could be created to contain all U-Participant Generator Operators within the purview of a Reliability Coordinator. U-Participants that are both Transmission Operators and Generator Operators would be members of both U-Groups. U-Participants, U-Endpoints, and U-Groups are used in the access control structures to provide access to individual UUDEX Subjects (U-Subjects). U-Groups are created by the U-Administrator and are managed by the U-Administrator or the designated U-Group Managers. U-Endpoints can be assigned UUDEX Roles (U-Roles) that can be used to further restrict access. U-Roles are assigned to individual U-Endpoints. For example, a U-Role of “Security Analyst” could be used to restrict which U-Endpoints can publish or subscribe security incident reports and vulnerability notifications, while a U-Role of “Transmission Planner” can be used to restrict which U-Endpoints can publish power system model updates. U-Role definitions are created by the U-Administrator, but the U-Roles are assigned to U-Endpoints by their respective UUDEX Participant Administrators (U-Participant Administrator). Because all information required to make security decisions is either included within the U-Endpoint’s X.509 digital certificate or stored in a datastore on the U-Server, all security decisions are performed and enforced within the U-Server. This reduces the complexity of the U-Client code and minimizes the chance for compromise of the integrity of the UUDEX security features.

97 MATHEMATICS AND COMPUTING↗

Cybersecurity for Grid Connected eXtreme Fast Charging (XFC) Station (CyberX) (Final Scientific/Technical Report)

This report summarizes the activities conducted under the DOE VTO funded project DE- EE0008451, where ABB Inc. (ABB), in collaboration with Idaho National Laboratory (INL), APS Global (APS), and XOS Trucks (XOS) pursued the development of a cyber-resilient extreme fast charging (XFC) management system. This project entitled Cybersecurity for Grid Connected eXtreme Fast Charging (XFC) Station (CyberX) focuses on a resilient architecture for smart charging EV Supply Equipment (EVSE) device control and Coordinated Anomaly Detection System (CADS) features that can be added at the charging site depot level to increase cybersecurity. The project was split into two budget periods focused first on developing the threat model and resilient control concepts and second on testing, improving, and validating those developed resilient control algorithms and features with a focus on key vulnerabilities identified during the threat assessment portion of the project. During the first budget period of the CyberX project, the ABB led team focused on activities to identify, model, and quantitatively prioritize high-impact attack scenarios with potential cyber-physical effects while also modeling and developing concepts for a resilient control system that could securely address integration of DERs and other resources with EV charging. Development of the security focused XFC management system (XMS) was accomplished first by offline simulation using a developed XFC station or depot with 480V input level and simulating measurement inputs to monitoring and control systems in concept development. A representative distribution grid model was developed supporting an EV charging site model with BESS and 6 general EV charging models. These EV charging models allowed multiple configurations of charging level, multiple connected protection and measurement devices, and simulation function to show general compromise of EV, BESS, and protection features based on parallel threat analysis. During the second budget period, the EV site and supporting systems model was developed in more detail and converted from offline model to real-time to real-time with EV charging hardware in the loop (HIL). The resilient control architecture developed as concept in the first part of the project was further tested and validated for integration of local energy resources and XFC charging station site equipment while maintaining cybersecure operating principles. The proposed resilient architecture for smart charging and cybersecurity features consists of two main concepts developed and tested within the project. The first concept is an XFC management system (XMS) consisting of a hardware gateway, software platform, and Supervisory Control and Data Acquisition (SCADA) or Distribution Management System integration components. The second concept is a Coordinated Anomaly Detection System (CADS) which forms a primarily software-related subsystem of the total CyberX solution focused on monitoring system measurements, estimation of measurement states, and predicting current at the utility point of interaction based on machine learning for anomaly detection.

33 ADVANCED PROPULSION SYSTEMS↗