Search NASA⌕ Search

SEARCH · Search NASA

Results for “Interface tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Dynamic tumor tracking using the Elekta Agility MLC

Purpose: To evaluate the performance of the Elekta Agility multileaf collimator (MLC) for dynamic real-time tumor tracking. Methods: The authors have developed a new control software which interfaces to the Agility MLC to dynamically program the movement of individual leaves, the dynamic leaf guides (DLGs), and the Y collimators (“jaws”) based on the actual target trajectory. A motion platform was used to perform dynamic tracking experiments with sinusoidal trajectories. The actual target positions reported by the motion platform at 20, 30, or 40 Hz were used as shift vectors for the MLC in beams-eye-view. The system latency of the MLC (i.e., the average latency comprising target device reporting latencies and MLC adjustment latency) and the geometric tracking accuracy were extracted from a sequence of MV portal images acquired during irradiation for the following treatment scenarios: leaf-only motion, jaw + leaf motion, and DLG + leaf motion. Results: The portal imager measurements indicated a clear dependence of the system latency on the target position reporting frequency. Deducting the effect of the target frequency, the leaf adjustment latency was measured to be 38 ± 3 ms for a maximum target speed v of 13 mm/s. The jaw + leaf adjustment latency was 53 ± 3 at a similar speed. The system latency at a target position frequency of 30 Hz was in the range of 56–61 ms for the leaves (v ≤ 31 mm/s), 71–78 ms for the jaw + leaf motion (v ≤ 25 mm/s), and 58–72 ms for the DLG + leaf motion (v ≤ 59 mm/s). The tracking accuracy showed a similar dependency on the target position frequency and the maximum target speed. For the leaves, the root-mean-squared error (RMSE) was between 0.6–1.5 mm depending on the maximum target speed. For the jaw + leaf (DLG + leaf) motion, the RMSE was between 0.7–1.5 mm (1.9–3.4 mm). Conclusions: The authors have measured the latency and geometric accuracy of the Agility MLC, facilitating its future use for clinical tracking applications.

60 APPLIED LIFE SCIENCES↗

Density variance dynamics in disparate shock tubes

This report discusses two experiments which investigate thin layer, heavy curtain fragmentation from the perspective of a Reynolds-Averaged mix model, in drastically disparate experimental regimes. The first, the centimeter/millisecond-scale “Horizontal Shock Tube” (HST) is a compressed-gas piston-driven shock tube experiment. The second, the “Multishock thin layer” (Mshock) experiment performed at the National Ignition Facility, is a micrometer/nanosecond-scale laser-driven shock tube experiment. Both are situations in which a heavy plane layer (a ‘curtain’) is initially suspended in a lighter medium. After being shocked from at least one side, the layer translates while its interfaces evolve due to the excitation of the Richtmyer-Meshkov instability at its surfaces. The evolution of density variance, which initially exists only on the surface of the layer, as it comes to encompass the whole layer interior is used as a description of layer fragmentation and dissolution. These experiments have each been simulated in the Los Alamos National Laboratory multi-physics code xRAGE, which includes fundamental hydrodynamics, extended plasma physics and radiation effects which are important to drive the high-energy density experiment, and the Besnard-Harlow-Rauenzahn (BHR) turbulence model. In each, the principal diagnostic for comparison is an experimental metric for the density (co)variance, b, which tracks the moments of the density field at the curtain interfaces and body. Due to experimental constraints in different regimes (i.e. optical diagnostics can be deployed on conventional shock tubes, while the plasma shock tubes must be imaged by x-rays; interfaces can be imposed to specification on laser-driven experiments, which are stored in the solid phase, while conventional experiments have imperfect control of the flow fields which separate the layer, etc.) the experiments are not designed to be perfect scaled cognates of one another. However, despite the separation of six orders of magnitude of scaling in time, and four in space, we are able to demonstrate that the same turbulence model, operating in the same fashion in the same computer code, is able to reproduce results in each experiment, by tracking evolution due to common relevant physics. Additionally, we will present preliminary work toward density variance comparisons in a single-interface Richtmyer-Meshkov configuration, the conventional fluid “Vertical Shock Tube” (VST) experiment, and the Modal Initial Conditions (ModCons) campaign fielded at the OMEGA-EP laser facility.

42 ENGINEERING↗

Robotics virtual rail system and method

A virtual track or rail system and method is described for execution by a robot. A user, through a user interface, generates a desired path comprised of at least one segment representative of the virtual track for the robot. Start and end points are assigned to the desired path and velocities are also associated with each of the at least one segment of the desired path. A waypoint file is generated including positions along the virtual track representing the desired path with the positions beginning from the start point to the end point including the velocities of each of the at least one segment. The waypoint file is sent to the robot for traversing along the virtual track.

42 ENGINEERING↗

Handheld portable real-time tracking and communications device

Portable handheld real-time tracking and communications devices include; a controller module, communications module including global positioning and mesh network radio module, data transfer and storage module, and a user interface module enclosed in a water-resistant enclosure. Real-time tracking and communications devices can be used by protective force, security and first responder personnel to provide situational awareness allowing for enhance coordination and effectiveness in rapid response situations. Such devices communicate to other authorized devices via mobile ad-hoc wireless networks, and do not require fixed infrastructure for their operation.

47 OTHER INSTRUMENTATION↗

Dynamics of Electric Polarization and Relaxation of Ions at Humid Calcite Surfaces

Mobile ions at mineral surfaces can respond to an applied electric field, adopting a new distribution that effectively represents polarization of the electrical double layer. When the field is released, the ions relax to their equilibrium distribution. In both cases, the dynamics are characteristic of the interface. However, current models of electrokinetic phenomena are not sufficiently robust to accurately predict collective ion dynamics at structurally and chemically specific mineral–water interfaces. Here, in this study, we use electrostatic force microscopy (EFM) to investigate the dynamics of ion relaxation at hydrated calcite (104) surfaces at controlled relative humidity (RH). Electrically biased probes are used to polarize the distributions of calcium and carbonate ions that are intrinsic to this interface across a range of RH values. Polarization kinetics are tracked by monitoring the tip–sample force gradient during charging, and EFM imaging is used to characterize the spatial relaxation dynamics after the applied field is released. Electrostatic finite element modeling of the sample/probe system across length-scales from nanometers to millimeters reproduces the observed stretched exponential charging response. Together, these results allow us to estimate the ion diffusivities at the interface across a wide range of RH values. These diffusivities increase by roughly 5 orders of magnitude as the RH is increased from 5 to 90%, highlighting the critical role of adsorbed water for surface ion solvation that enables ion mobility.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spatiotemporal Visualization and Chemical Identification of the Metal Diffusion Layer at the Electrochemical Interface

The diffusion layer created by transition metal dissolution is ubiquitous at the electrochemical solid-liquid interface and plays a key role in determining electrochemical performance. Tracking the spatiotemporal dynamics of the diffusion layer has remained an unresolved challenge. With spatially resolved synchrotron X-ray fluorescence microscopy and micro-X-ray absorption spectroscopy, we demonstrate the in situ visualization and chemical identification of the dynamic diffusion layer near the electrode surface under electrochemical operating conditions. Finally, our method allows for direct mapping of the reactive electrochemical interface and provides insights into engineering the diffusion layer for improving electrochemical performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Advancing the Authenticatable Container Tracking System (ACTS)

The Authenticatable Container Tracking System (ACTS) is an extensible secure container tag that can be used to optimize chain-of-custody monitoring for packaged nuclear materials as they are being stored, processed, and transported. Based on the ultra–low power TI MSP430 mixed-signal microcontroller, ACTS is an active device that uses an almost-universal core platform that can be appropriately configured with expansion modules to provide the application-specific data acquisition, data logging, container sealing, and communications functions needed for 21st century material accountancy, monitoring, and tracking applications. This core architecture enables appropriately designed modules to be easily interfaced to the basic system, providing an integration path for current and new technologies. ACTS contains a built-in set of sensors and supports an expansion bus for up to six additional communications, tracking, authentication, encryption, sealing, location, or sensing modules that may enhance the monitoring and tracking of designated containers for specific applications. To date, testing has used an IEEE 802.15.4-2011 ultra-wideband–compliant wireless transceiver module that has additional capabilities for indoor positioning and proximity location. Proximity-based location (i.e., where an ACTS tag knows where it is relative to other ACTS tags) will be explored as a continuity-of-knowledge mechanism to determine unauthorized movement of containers in storage arrays of many items. Partners for this system are Oak Ridge National Laboratory, Argonne National Laboratory, Savannah River National Laboratory, Pacific Northwest National Laboratory and commercialization partner the Aquila Group.

Younkin, Jim↗

Advancing the Authenticatable Container Tracking System (ACTS)

The Authenticatable Container Tracking System (ACTS) is an extensible secure container tag that can be used to optimize chain-of-custody monitoring for packaged nuclear materials as they are being stored, processed, and transported. Based on the ultra–low power TI MSP430 mixed-signal microcontroller, ACTS is an active device that uses an almost-universal core platform that can be appropriately configured with expansion modules to provide the application-specific data acquisition, data logging, container sealing, and communications functions needed for 21st century material accountancy, monitoring, and tracking applications. This core architecture enables appropriately designed modules to be easily interfaced to the basic system, providing an integration path for current and new technologies. ACTS contains a built-in set of sensors and supports an expansion bus for up to six additional communications, tracking, authentication, encryption, sealing, location, or sensing modules that may enhance the monitoring and tracking of designated containers for specific applications. To date, testing has used an IEEE 802.15.4-2011 ultra-wideband–compliant wireless transceiver module that has additional capabilities for indoor positioning and proximity location. Proximity-based location (i.e., where an ACTS tag knows where it is relative to other ACTS tags) will be explored as a continuity-of-knowledge mechanism to determine unauthorized movement of containers in storage arrays of many items. Partners for this system are Oak Ridge National Laboratory, Argonne National Laboratory, Savannah River National Laboratory, Pacific Northwest National Laboratory, and commercialization partner the Aquila Group.

Younkin, James↗

Modeling multidimensional and multispecies biofilms in porous media

ABSTRACT Modeling multidimensional and multispecies biofilm in porous media at the pore scale is challenging due to the need to simultaneously track the microbial community in the biofilms and the interfaces between the biofilms and the fluid. Therefore, researchers usually assume that the model has only one dimension in space or has only one microbial species. This work uses bioremediation of U(VI)‐contaminated groundwater as the context to develop a two‐dimensional and multispecies biofilm model. The model simulates the transverse mixing zone in which U(VI) is mixed with propionate, a nutrient externally supplied to stimulate the growth of microorganisms. The model considers multiple interactions among fluid flow, transport and reaction of chemical species, and growth of biofilm. The biofilm consists of two types of active biomass (syntrophs and dissimilatory metal reducing bacteria [DMBR]) and inert biomass. The two types of active biomass collaboratively remove U(VI). The model outputs biomass distribution, chemical species concentrations, and fluid flow at the pore scale to fundamentally study the multiple interactions. The model also outputs the contaminant removal rate that can be potentially used for up‐scaling studies. The simulated results are generally consistent with experimental observations from other studies in trend. The trend can be explained by the multiple interactions based on thermodynamics and microbial kinetics. Biotechnol. Bioeng. 2017;114: 1679–1687. © 2017 Wiley Periodicals, Inc.

Tang, Youneng↗

Improved experimental and diagnostic techniques for dynamic tensile stress–strain measurement with a Kolsky tension bar

Kolsky tension bar experiments were improved for dynamic tensile stress–strain measurements with higher fidelity and minimal uncertainties. The difficulties associated with specimen gripping, relatively short gage section, and geometric discontinuity at the bar ends all compromise the accuracy of the traditional strain measurement method in a Kolsky tension bar experiment. Here in this study, an improved three-channel splitting-beam laser extensometer technique was developed to directly and independently track the displacement of the incident and transmission bar interfaces. By adopting a dual-channel configuration on the incident bar side, the resolution and measurement range of this laser extensometer were coordinated between the two channels to provide highly precise measurement at both small and large strains under high strain-rate loading condition. On the transmission bar side an amplified channel, similar to that used on the incident bar side, was adopted to measure the transmission bar displacement with high resolution. With this novel design, a maximum resolution of approximately 500 nm can be obtained for the bar displacement measurement, which corresponds to a strain of 0.0079% for a specimen with 6.35 mm gage length. To further improve the accuracy, a pair of lock nuts were used to tighten the tensile specimen to the bars in an effort not only to prevent the specimen from potential pre-torsional deformation and damage during installation, but also to provide better thread engagement between the specimen and the bar ends. As a demonstration of this technique, dynamic tensile stress–strain response of a 304L stainless steel was characterized with high resolution in both elastic and plastic deformations.

42 ENGINEERING↗

Electro–Oxidation of Nitroxide Radicals: Adsorption–Mediated Charge Transfer Probed Using SERS and Potentiometry

Organic compounds containing nitroxide radicals such as 4–hydroxy–2,2,6,6–tetramethylpiperidine–1–oxyl (4–hydroxy–TEMPO) are redox–active and are of interest for potential applications in redox flow batteries. The mechanisms governing charge–transfer reactions of such compounds are not well understood. Specifically, the anodic charge transfer coefficient (αa) corresponding to the electro–oxidation of 4–hydroxy–TEMPO in an aqueous medium is ~0.9, i.e., αa deviates considerably from the expected value (0.5) for a symmetric single–step one–electron transfer redox reaction. In a previous publication (J. Electrochem. Soc., 2020, 167, 143505), we have proposed a reaction mechanism to explain such asymmetric behavior by invoking adsorption–desorption processes. In the proposed mechanism, reversible oxidation of 4–hydroxy–TEMPO leads to the adsorption of the oxidation product, which then undergoes slow rate–limiting desorption from the electrode surface. In the present contribution, supporting evidence is provided for this mechanism. In situ surface–enhanced Raman spectroscopy combined with density functional theory simulations are employed to confirm the presence of surface–adsorbed species at a Au electrode during electro–oxidation of 4–hydroxy–TEMPO. Furthermore, we employ chronopotentiometry to track the gradual re–equilibration of the electrode–electrolyte interface following the electro–oxidation of 4–hydroxy–TEMPO. Analysis of the chronopotentiometry data further suggests the presence of adsorbed species, which were previously proposed and are now confirmed by direct spectroscopic evidence.

25 ENERGY STORAGE↗

On the Preconditioning of a Newton-Krylov Solver for a High-Order reconstructed Discontinuous Galerkin Discretization of All-Speed Compressible Flow with Phase Change for Application in Laser-Based Additive Manufacturing

This dissertation focuses on the development of a fully-implicit, high-order compressible ow solver with phase change. The work is motivated by laser-induced phase change applications, particularly by the need to develop large-scale multi-physics simulations of the selective laser melting (SLM) process in metal additive manufacturing (3D printing). Simulations of the SLM process require precise tracking of multi-material solid-liquid-gas interfaces, due to laser-induced melting/ solidi cation and evaporation/condensation of metal powder in an ambient gas. These rapid density variations and phase change processes tightly couple the governing equations, requiring a fully compressible framework to robustly capture the rapid density variations of the ambient gas and the melting/evaporation of the metal powder. For non-isothermal phase change, the velocity is gradually suppressed through the mushy region by a variable viscosity and Darcy source term model. The governing equations are discretized up to 4th-order accuracy with our reconstructed Discontinuous Galerkin spatial discretization scheme and up to 5th-order accuracy with L-stable fully implicit time discretization schemes (BDF2 and ESDIRK3-5). The resulting set of non-linear equations is solved using a robust Newton-Krylov method, with the Jacobian-free version of the GMRES solver for linear iterations. Due to the sti nes associated with the acoustic waves and thermal and viscous/material strength e ects, preconditioning the GMRES solver is essential. A robust and scalable approximate block factorization preconditioner was developed, which utilizes the velocity-pressure (vP) and velocity-temperature (vT) Schur complement systems. This multigrid block reduction preconditioning technique converges for high CFL/Fourier numbers and exhibits excellent parallel and algorithmic scalability on classic benchmark problems in uid dynamics (lid-driven cavity ow and natural convection heat transfer) as well as for laser-induced phase change problems in 2D and 3D.

42 ENGINEERING↗

Evaluation of Linear Accelerator Gating With Real-Time Electromagnetic Tracking

Purpose: Intrafraction organ motion can produce dosimetric errors in radiotherapy. Commonly, the linear accelerator is gated using real-time breathing phase obtained by way of external sensors. However, the external anatomy does not always correlate well with the internal position. We examined a beam gating technique using signals from implanted wireless transponders that provided real-time feedback on the tumor location without an imaging dose to the patient. Methods and Materials: An interface was developed between Calypso Medical's four-dimensional electromagnetic tracking system and a Varian Trilogy linear accelerator. A film phantom was mounted on a motion platform programmed with lung motion trajectories. Deliveries were performed when the beam was gated according to the signal from the wireless transponders. The dosimetric advantages of beam gating and the system latencies were quantified. Results: Beam gating using on internal position monitoring provided up to a twofold increase in the dose gradients. The percentage of points failing to be within {+-}10 cGy of the planned dose (maximal dose, {approx}200 cGy) was 3.4% for gating and 32.1% for no intervention in the presence of motion. The mean latencies between the transponder position and linear accelerator modulation were 75.0 {+-}12.7 ms for beam on and 65.1 {+-} 12.9 ms for beam off. Conclusion: We have presented the results from a novel method for gating the linear accelerator using trackable wireless internal fiducial markers without the use of ionizing radiation for imaging. The latencies observed were suitable for gating using electromagnetic fiducial markers, which results in dosimetric improvements for irradiation in the presence of motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Markerless tracking of small lung tumors for stereotactic radiotherapy

Purpose: (1) To validate retrospective markerless tracking software for small lung tumors by comparing tracked motion in 4-dimensional planning computed tomography (4DCT) derived kV projection images and known tumor motion in the same 4DCT. (2) To evaluate variability of tumor motion using kV projection images from cone-beam computed tomography (CBCT) scans acquired on different days. Methods: Nonclinical tumor tracking software (TTS) used a normalized cross correlation algorithm to track the tumor on enhanced kV projection images (e.g., from a CBCT scan). The reference dataset consisted of digitally reconstructed radiographs (DRRs) from one phase of a planning 4DCT. TTS matches two in-plane coordinates and obtains the out-of-plane coordinate by triangulating with match results from other projections. (1) To validate TTS, tracking results were compared with known 4DCT tumor motion for two patients (A and B). Projection images (1 image/1°) were digitally reconstructed for each 4DCT phase. From these, kV projection series were composed simulating full breathing cycles every 20° of gantry rotation [breathing period = 20°/(6°/s) = 3.33 s]. Reference templates were 360 “tumor enhanced” DRRs from the 4DCT expiration phase. TTS-derived tumor motion was compared to known tumor motion on 4DCT. (2) For five patients, TTS-assessed motion during clinical CBCT acquisition was compared with motion on the planning 4DCT, and the motion component in the Y (cranio–caudal)-direction was compared with the motion of an external marker box (RPM, real-time position management). Results: (1) Validation results: TTS for case A (tumor 6.2 cm{sup 3}, 32 mm axial diameter) over 360° showed mean motion X (medial–lateral) = 3.4, Y = 11.5, and Z (ventral–dorsal) = 4.9 mm (1 SD < 1.0 mm). Corresponding 4DCT motion was X = 3.1, Y = 11.3, and Z = 5.1 mm. Correlation coefficients between TTS tumor motion and displacement of the tumor’s center of mass (CoM) on 4DCT were 0.64, 0.96, and 0.82 (X, Y, and Z, respectively). For case B (4.1 cm{sup 3}, 20 mm diameter), due to temporarily decreased tumor visibility preventing TTS from resolving the tumor, robust tracking data were only available between angles 300°–40° and 120°–220°. Mean motion according to TTS was X = 2.0, Y = 7.7, and Z = 8.2 mm (1 SD < 0.9 mm). Tumor motion on 4DCT was X = 1.8, Y = 7.6, and Z = 9.5 mm and correlation coefficients between TTS motion and CoM displacement were 0.59, 0.95, and 0.93 (X, Y, and Z, respectively). (2) Clinical results: TTS revealed a mean intrafraction variation in tumor motion in Y-direction of >2.0 mm (1 SD) in four of five patients. In addition, clinical tumor motion amplitude differed from that seen on planning 4DCT. Internal and external structures that create abrupt density change (e.g., table-top edge, interface between lung/mediastinum and lung/heart) were observed to prevent 360° tracking of the tumor. Correlation coefficients between TTS motion in the Y-direction and the RPM signal (22 observations) ranged from 0.78 to 0.96. In 2D, 241 TTS matches at end-inspiration and end-expiration were visually validated: mean difference was 0.8 mm (SD = 0.7) for both. Conclusions: TTS can track small lung tumors if these are visible in kV projections. A 4DCT dataset can be used to validate kV tracking of moving targets. TTS and 4DCT displacement agreed to within 2 mm. TTS and RPM motion were closely associated but tumor motion during CBCT can vary from the planning 4DCT.

60 APPLIED LIFE SCIENCES↗

Simulation of Impedance Changes with Aging in Lithium Titanate-based Cells Using Physics-Based Dimensionless Modeling

Quantifying aging effects in lithium-ion cells with chemistries that have a flat open circuit potential is challenging. We implement a physics-based electrochemical model to track changes in the electrochemical impedance response of lithium titanate-based cells. Frequency domain equations of a pseudo two-dimensional model are made dimensionless, and the corresponding non-dimensional parameters are estimated using a Levenberg-Marquardt routine. The model weighs the relative contributions of changes in diffusion, ionic conduction within the electrolyte phase against solid phase electronic conduction towards cell aging. Solid-phase diffusion, charge transfer resistance and double layer capacitance at the solid-liquid interface are accounted for in the particle impedance. The estimation routine tracks dimensionless parameters using accelerated cycling data from full cells over 1000 cycles. The model can be deployed within a short time for state estimation using physics-based models without requiring prior knowledge of the battery chemistry, format, or capacity.

25 ENERGY STORAGE↗

Optofluidic solar concentrators using electrowetting tracking: Concept, design, and characterization

We introduce a novel optofluidic solar concentration system based on electrowetting tracking. With two immiscible fluids in a transparent cell, we can actively control the orientation of fluid fluid interface via electrowetting. The naturally-formed meniscus between the two liquids can function as a dynamic optical prism for solar tracking and sunlight steering. An integrated optofluidic solar concentrator can be constructed from the liquid prism tracker in combination with a fixed and static optical condenser (Fresnel lens). Therefore, the liquid prisms can adaptively focus sunlight on a concentrating photovoltaic (CPV) cell sitting on the focus of the Fresnel lens as the sun moves. Because of the unique design, electrowetting tracking allows the concentrator to adaptively track both the daily and seasonal changes of the sun's orbit (dual-axis tracking) without bulky, expensive and inefficient mechanical moving parts. This approach can potentially reduce capital costs for CPV and increases operational efficiency by eliminating the power consumption of mechanical tracking. Importantly, the elimination of bulky tracking hardware and quiet operation will allow extensive residential deployment of concentrated solar power. In comparison with traditional silicon-based photovoltaic (PV) solar cells, the electrowetting-based self-tracking technology will generate,similar to 70% more green energy with a 50% cost reduction. (C) 2013 Elsevier Ltd. All rights reserved.

Cheng, JT↗

Structure of mycobacterial 3'-to-5' RNA:DNA helicase Lhr bound to a ssDNA tracking strand highlights distinctive features of a novel family of bacterial helicases

Mycobacterial Lhr is a DNA damage-inducible superfamily 2 helicase that uses adenosine triphosphate (ATP) hydrolysis to drive unidirectional 3'-to-5' translocation along single-stranded DNA (ssDNA) and to unwind RNA:DNA duplexes en route. ATPase, translocase and helicase activities are encompassed within the N-terminal 856-amino acid segment. The crystal structure of Lhr-(1–856) in complex with AMPPNP•Mg 2+ and ssDNA defines a new helicase family. The enzyme comprises two N-terminal RecA-like modules, a winged helix (WH) domain and a unique C-terminal domain. The 3' ssDNA end binds in a crescent-shaped groove at the interface between the first RecA domain and the WH domain and tracks 5' into a groove between the second RecA and C domains. A kissing interaction between the second RecA and C domains forms an aperture that demarcates a putative junction between the loading strand tail and the duplex, with the first duplex nucleoside bookended by stacking on Trp597. Intercalation of Ile528 between nucleosides of the loading strand creates another bookend. Coupling of ATP hydrolysis to RNA:DNA unwinding is dependent on Trp597 and Ile528, and on Thr145 and Arg279 that contact phosphates of the loading strand. The structural and functional data suggest a ratchet mechanism of translocation and unwinding coupled to ATP-driven domain movements.

59 BASIC BIOLOGICAL SCIENCES↗

What Is a Polyolefin? A Critical Overview of Ethylene Copolymers Used as Solar Photovoltaic Module Encapsulants

In recent years, photovoltaic (PV) encapsulant films marketed as polyolefins (POs), more specifically as PO elastomers (POEs) and thermoplastic POs (TPOs), have gained significant market share and are projected to become the dominant encapsulation films by 2030. Relative to other industries, there are significant misconceptions about the term PO in the PV industry. Both in the scientific literature as well as in sales and advertising, the terms PO, POE, and TPO are often misused to describe the same type of material with comparable properties, while in reality these may each consist of separate material classes. This paper provides a comprehensive literature and market review, to showcase a broad range of PO and other ethylene copolymer encapsulants from recent studies, and discusses the materials' properties to clarify what constitutes a “polyolefin.” In addition, to promote a clearer comparison of encapsulant properties, we propose a two‐dimensional taxonomy to categorize polymers used in module manufacturing, including POs. In terms of improving the reliability of solar PV modules, PO‐based encapsulants have several advantages (including lower water uptake and ion diffusion), but might come with disadvantages too, such as a more complex processing and a higher sensitivity to the storage conditions and shelf life. All this might prospectively impact adhesion properties of the encapsulant to other materials' interfaces (glass, cells etc.) and end‐product quality. Because the track record of field‐deployed PV modules containing PO encapsulants is also limited, we hope to contribute to better material understanding and precision in communication in PV to secure quality.

14 SOLAR ENERGY↗