At least 217 records · Page 12

A chevron beam-splitter interferometer

Fully tilt compensated double-pass chevron beam splitter, that removes channelling effects and permits optical phase tuning, is wavelength independent and allows small errors in alignment that are not tolerated in Michelson, Machzender, or Sagnac interferometers. Device is very useful in experiments where background vibration affects conventional interferometers.

Breckinridge, J. B.↗

Exposure time for space-borne IR spatial interferometer

A mathematical analysis is performed to determine the relationship between the signal-to-noise ratio and the exposure time for an orbiting IR heterodyne spatial interferometer. The analysis includes consideration of the transformation of the interferogram to obtain the source angular intensity distribution so that the signal-to-noise ratio pertains to the angular distribution rather than to the interferogram. The analysis is applied to a number of known IR sources. The results presented show that an interferometer with a 30-m baseline using half-meter telescopes should be able to image a source such as IRC + 30219 with a signal-to-noise ratio of 10 in a total exposure time of less than an hour.

Wolfe, R. H., Jr.↗

A two-dimensional white-light amplitude interferometer

A review of the applications of a point-symmetric, 180-degree, rotational shearing interferometer is given. Material includes, photographs of the Michelson stellar interferometer fringes from Alpha-Lyr, measures of amplitude of phase excursions in the atmosphere, and a measure of the order of interference of speckle patterns. New material includes unpublished double star speckle patterns to illustrate the isoplanatic patch, a measure of the time fluctuations in the earth's atmosphere, and measurements of the properties of a 256 channel linear reticon.

Breckinridge, J. B.↗

The Tidbinbilla interferometer

A proposal to operate a two element interferometer using the 64 m and 26 m antennas of the Tidbinbilla Deep Space Station is discussed. The instrument is to be operated as a correlation interferometer, the sine and cosine products being sampled once per second and recorded for later analysis. The receiver systems are currently under development. Preliminary measurements of the delay line and local oscillator systems and the site cables suggest that a phase stability to within about 1 deg should be achievable with temperature control of the receiver packages.

Batty, M. J.↗

Accurate radio positions with the Tidbinbilla interferometer

The Tidbinbilla interferometer (Batty et al., 1977) is designed specifically to provide accurate radio position measurements of compact radio sources in the Southern Hemisphere with high sensitivity. The interferometer uses the 26-m and 64-m antennas of the Deep Space Network at Tidbinbilla, near Canberra. The two antennas are separated by 200 m on a north-south baseline. By utilizing the existing antennas and the low-noise traveling-wave masers at 2.29 GHz, it has been possible to produce a high-sensitivity instrument with a minimum of capital expenditure. The north-south baseline ensures that a good range of UV coverage is obtained, so that sources lying in the declination range between about -80 and +30 deg may be observed with nearly orthogonal projected baselines of no less than about 1000 lambda. The instrument also provides high-accuracy flux density measurements for compact radio sources.

Batty, M. J.↗

Interferometer

An interferometer of relatively simple design which is tilt compensated, and which facilitates adjustment of the path lengths of split light beams is described. The interferometer includes a pair of plate-like elements with a dielectric coating and an oil film between them, that forms a beamsplitter interface, and with a pair of reflector surfaces at the ends of the plates. A pair of retroreflectors are positioned so that each split beam component is directed by a retroreflector onto one of the reflector surfaces and is then returned to the beamsplitter interface, so that the reflector surfaces tilt in a direction and amount that compensates for tilting of the beamsplitter interface.

Breckinridge, J. B.↗

Near-infrared spectral imaging Michelson interferometer for astronomical applications

The design and operation of an imaging Michelson interferometer-spectrometer used for near-infrared (0.8 micron to 2.5 microns) spectral imaging are reported. The system employs a rapid scan interferometer modified for stable low resolution (250/cm) performance and a 42 element PbS linear detector array. A microcomputer system is described which provides data acquisition, coadding, and Fourier transformation for near real-time presentation of the spectra of all 42 scene elements. The electronic and mechanical designs are discussed and telescope performance data presented.

Wells, C. W.↗

DC calibration of the strain sensitivity of a single mode optical fiber interferometer

The strain sensitivity of an optical fiber interferometer developed for the detection of pulsed ultrasonic waves in solids has been calibrated. The optical paths in both signal and reference arms of the interferometer are through similar 2 m lengths of ITT-110 single mode fibers mode stripped by index matching at both ends and attached to opposite sides of a 30 cm plexiglas bar 0.3 cm thick. Light from the output ends of both fibers was superimposed to form an interference fringe pattern that was interrogated in the far field to give a signal proportional to the differential optical fiber path length. Strain sensitivity was determined by comparing data obtained by clamping and bending the bar at different lengths to simple cantilever beam theory. Calibration indicates a minimum theoretical detectable strain of less than 10 to the -10.

Claus, R. O.↗

Detection of ultrasonic waves in solids by an optical fiber interferometer

An optical fiber interferometer was developed for the detection of ultrasonic waves in solids. The optical paths in both the signal and reference arms of the Mach-Zehnder interferometer are through the cores of similar lengths of single mode fiber mode stripped at both input and output. Instantaneous translation of the pattern is proportional to the localized strain produced by ultrasonic bulk waves generated in the disc and integrated along the fiber path. By spatially filtering the moving fringe pattern and synchronously demodulating the filtered optical intensity distirbution, a signal proportional to the integrated strain is obtained.

Claus, R. O.↗

Dual differential interferometer for measurements of broadband surface acoustic waves

A simple duel interferometer which uses two pairs of orthogonally polarized optical beams to measure both the amplitude and direction of propagation of broadband ultrasonic surface waves is described. Each pair of focused laser probe beams is used in a separate wideband differential interferometer to independently detect the component of surface wave motion along one direction on the surface. By combining the two output signals corresponding to both components, the two dimensional surface profile and its variation as a function of time is determined.

Turner, T. M.↗

Sky input horn for a far-infrared interferometer

A unique design has been developed whereby a compound parabolic concentrator (CPC) and a compound elliptical concentrator (CEC) are joined at their throats. The CPC serves as the field-defining optics, in that it accepts up to a certain maximum acceptance angle and then concentrates this accepted energy at its throat. Energy incident from angles greater than the acceptance angle is rejected. The CEC takes the energy concentrated at the CPC throat and then redirects this energy into a finite-sized pupil a given distance away. The considered design will be used as the sky input horn for a cryogenic far-infrared polarizing interferometer to be flown on NASA's Cosmic Background Explorer satellite. The interferometer will operate at 2 K and measure the 3-K cosmic background radiation of the universe in the 100-micrometer-1-cm spectral range.

Miller, M. S.↗

Holographic Twyman-Green Interferometer

Off-axis Fresnel zone plate used to obtain fringe visibility close to unity. Holographic Twyman-Green Interferometer (HTG) employs off-axis Fresnel zone plate (OFZP) as beam splitter and beam diverger in place of two separate elements that perform those functions in conventional TwymanGreen interferometer.

Chen, C. W.↗

Dual-beam skin friction interferometer

A portable dual-laser beam interferometer is described that nonintrusively measures skin friction by monitoring the thickness change of an oil film at two locations while said oil film is subjected to shear stress. An interferometer flat is utilized to develop the two beams. Light detectors sense the beam reflections from the oil film and the surface thereunder. The signals from the detectors are recorded so that the number of interference fringes produced over a given time span may be counted.

Monson, D. J.↗

Application of a laser interferometer skin-friction meter in complex flows

The application of a nonintrusive laser-interferometer skin-friction meter, which measures skin friction with a remotely located laser interferometer that monitors the thickness change of a thin oil film, is extended both experimentally and theoretically to several complex wind-tunnel flows. These include two-dimensional seperated and reattached subsonic flows with large pressure and shear gradients, and two and three-dimensional supersonic flows at high Reynolds number, which include variable wall temperatures and cross-flows. In addition, it is found that the instrument can provide an accurate location of the mean reattachment length for separated flows. Results show that levels up to 120 N/sq m, or 40 times higher than previous tests, can be obtained, despite encountering some limits to the method for very high skin-friction levels. It is concluded that these results establish the utility of this instrument for measuring skin friction in a wide variety of flows of interest in aerodynamic testing.

Monson, D. J.↗

A laser interferometer for measuring skin friction in three-dimensional flows

A new, nonintrusive method is described for measuring skin friction in three-dimensional flows with unknown direction. The method uses a laser interferometer to measure the changing slope of a thin oil film applied to a surface experiencing shear stress. The details of the method are described, and skin friction measurements taken in a swirling three-dimensional boundary-layer flow are presented. Comparisons between analytical results and experimental values from the laser interferometer method and from a bidirectional surface-fence gauge are made.

Monson, D. J.↗

Effects of spacecraft reflections on RF interferometer position location accuracy

This report describes one of three study tasks related to the application of an RF interferometer aboard a low-orbiting spacecraft to determine the location of ground-based transmitters. Computer modeling was used to estimate the error in the measured signal angle-of-arrival caused by reflection and diffraction off the spacecraft. Existing computer codes (NEC-BSC) were modified and used to determine the perturbation, due to the spacecraft, in the phase difference between two interferometer antennas, suspended on either side of the spacecraft. This phase perturbation was found as a function of the angle-of-arrival of the signal from a far-field source. The spacecraft antennas were assumed to be circularly polarized with a cardioid pattern. It was found that the perturbation was as much 12.4 deg within the + or - 60 deg field-of-view. This suggests that phase calibration and correction of phase measurements are essential for precision position location using this technique.

Wallace, R. G.↗

Nd:YAG holographic interferometer for aerodynamic research

A holographic interferometer system has been installed in the NASA Ames 2- by 2-Foot Transonic Wind Tunnel. The system incorporates a modern 10 pps, Nd:YAG pulsed laser which provides reliable operation and is easy to align. The spatial filtering requirements of the unstable resonator beam are described, as well as the integration of the system into the existing schlieren system. A two-plate holographic interferometer is used to reconstruct flow field data. For static wind tunnel models, the single exposure holograms are recorded in the usual manner; however, for dynamic models such as oscillating airfoils, synchronous laser hologram recording is used.

Craig, J. E.↗